Barry J. Doyle
University of Western Australia
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Barry J. Doyle.
Journal of Vascular Surgery | 2009
Barry J. Doyle; Anthony Callanan; Paul E. Burke; Pierce A. Grace; Michael T. Walsh; David A. Vorp; Timothy M. McGloughlin
OBJECTIVE Abdominal aortic aneurysm (AAA) rupture is believed to occur when the local mechanical stress exceeds the local mechanical strength of the wall tissue. On the basis of this hypothesis, the knowledge of the stress acting on the wall of an unruptured aneurysm could be useful in determining the risk of rupture. The role of asymmetry has previously been identified in idealized AAA models and is now studied using realistic AAAs in the current work. METHODS Fifteen patient-specific AAAs were studied to estimate the relationship between wall stress and geometrical parameters. Three-dimensional AAA models were reconstructed from computed tomography scan data. The stress distribution on the AAA wall was evaluated by the finite element method, and peak wall stress was compared with both diameter and centerline asymmetry. A simple method of determining asymmetry was adapted and developed. Statistical analyses were performed to determine potential significance of results. RESULTS Mean von Mises peak wall stress +/- standard deviation was 0.4505 +/- 0.14 MPa (range, 0.3157-0.9048 MPa). Posterior wall stress increases with anterior centerline asymmetry. Peak stress increased by 48% and posterior wall stress by 38% when asymmetry was introduced into a realistic AAA model. CONCLUSION The relationship between posterior wall stress and AAA asymmetry showed that excessive bulging of one surface results in elevated wall stress on the opposite surface. Assessing the degree of bulging and asymmetry that is experienced in an individual AAA may be of benefit to surgeons in the decision-making process and may provide a useful adjunct to diameter as a surgical intervention guide.
Journal of Biomechanical Engineering-transactions of The Asme | 2008
Barry J. Doyle; Liam Morris; Anthony Callanan; P. Kelly; David A. Vorp; Timothy M. McGloughlin
Abdominal aortic aneurysm (AAA) can be defined as a permanent and irreversible dilation of the infrarenal aorta. AAAs are often considered to be an aorta with a diameter 1.5 times the normal infrarenal aorta diameter. This paper describes a technique to manufacture realistic silicone AAA models for use with experimental studies. This paper is concerned with the reconstruction and manufacturing process of patient-specific AAAs. 3D reconstruction from computed tomography scan data allows the AAA to be created. Mould sets are then designed for these AAA models utilizing computer aided designcomputer aided manufacture techniques and combined with the injection-moulding method. Silicone rubber forms the basis of the resulting AAA model. Assessment of wall thickness and overall percentage difference from the final silicone model to that of the computer-generated model was performed. In these realistic AAA models, wall thickness was found to vary by an average of 9.21%. The percentage difference in wall thickness recorded can be attributed to the contraction of the casting wax and the expansion of the silicone during model manufacture. This method may be used in conjunction with wall stress studies using the photoelastic method or in fluid dynamic studies using a laser-Doppler anemometry. In conclusion, these patient-specific rubber AAA models can be used in experimental investigations, but should be assessed for wall thickness variability once manufactured.
Journal of Biomechanics | 2010
Barry J. Doyle; Aidan J. Cloonan; Michael T. Walsh; David A. Vorp; Timothy M. McGloughlin
In the event of abdominal aortic aneurysm (AAA) rupture, the outcome is often death. This paper aims to experimentally identify the rupture locations of in vitro AAA models and validate these rupture sites using finite element analysis (FEA). Silicone rubber AAA models were manufactured using two different materials (Sylgard 160 and Sylgard 170, Dow Corning) and imaged using computed tomography (CT). Experimental models were inflated until rupture with high speed photography used to capture the site of rupture. 3D reconstructions from CT scans and subsequent FEA of these models enabled the wall stress and wall thickness to be determined for each of the geometries. Experimental models ruptured at regions of inflection, not at regions of maximum diameter. Rupture pressures (mean+/-SD) for the Sylgard 160 and Sylgard 170 models were 650.6+/-195.1mmHg and 410.7+/-159.9mmHg, respectively. Computational models accurately predicted the locations of rupture. Peak wall stress for the Sylgard 160 and Sylgard 170 models was 2.15+/-0.26MPa at an internal pressure of 650mmHg and 1.69+/-0.38MPa at an internal pressure of 410mmHg, respectively. Mean wall thickness of all models was 2.19+/-0.40mm, with a mean wall thickness at the location of rupture of 1.85+/-0.33 and 1.71+/-0.29mm for the Sylgard 160 and Sylgard 170 materials, respectively. Rupture occurred at the location of peak stress in 80% (16/20) of cases and at high stress regions but not peak stress in 10% (2/20) of cases. 10% (2/20) of models had defects in the AAA wall which moved the rupture location away from regions of elevated stress. The results presented may further contribute to the understanding of AAA biomechanics and ultimately AAA rupture prediction.
Journal of Biomechanics | 2014
Siobhan A. O’Leary; Eamon G. Kavanagh; Pierce A. Grace; Tim McGloughlin; Barry J. Doyle
Intraluminal thrombus (ILT) is present in 75% of clinically-relevant abdominal aortic aneurysms (AAAs) yet, despite much research effort, its role in AAA biomechanics remains unclear. The aim of this work is to further evaluate the biomechanics of ILT and determine if different ILT morphologies have varying mechanical properties. Biaxial mechanical tests were performed on ILT samples harvested from 19 patients undergoing open surgical repair. ILT were separated into luminal, medial and medial/abluminal layers. A total of 356 tests were performed and the Cauchy stress (σ) and tangential modulus (TM) at a stretch ratio (λ) of 1.14 were recorded for each test in both the circumferential (θ) and longitudinal (L) directions. Our data revealed three distinct types of ILT morphologies, each with a unique set of mechanical properties. All ILT layers were found to be isotropic and inhomogeneous. Type 1 (n=10) was a multi-layered ILT (thick medial/abluminal layer) whose strength and stiffness decreased gradually from the luminal to the medial/abluminal layer. Type 2 (n=6) was a multi-layered ILT (thin/highly degraded medial/abluminal layer) whose strength and stiffness decreased abruptly between the luminal and medial/abluminal layer and Type 3 (n=3) is a single layered ILT with a lower strength and stiffness than Types 1 and 2. In a sub-study, we found the luminal layer to be stronger and stiffer in the posterior than the anterior region. This work provides further insights to the biomechanical behaviour of ILT and the use of our ILT classification may be useful in future studies.
Vascular Disease Prevention | 2009
Barry J. Doyle; Anthony Callanan; Michael T. Walsh; Pierce A. Grace; Timothy M. McGloughlin
Currently, abdominal aortic aneurysms (AAAs), which are a permanent dilation of the aorta, are treated surgi- cally when the maximum transverse diameter surpasses 5.5cm. AAA rupture occurs when the locally acting wall stress exceeds the locally acting wall strength. There is a need to review the current diameter-based criterion, and so it may be clinically useful to develop an additional tool to aid the surgical decision-making process. A Finite Element Analysis Rup- ture Index (FEARI) was developed. Ten patient-specific AAAs were reconstructed, and the corresponding wall stress computed. Previous experimental work on determination of ultimate tensile strengths (UTS) from AAA tissue samples was implemented in this study. By com- bining peak wall stress along with average regional UTS, a new approach to the estimation of patient-specific rupture risk has been developed. Ten cases were studied, all of which were awaiting or had previously undergone surgical AAA repair. A detailed exami- nation of these ten cases utilising the FEARI analysis suggested that there was a possibility that some of the AAAs may have been less prone to rupture than previously considered. It is proposed that FEARI, used alongside other rupture risk factors, may improve the current surgical decision-making process. The use of FEARI as an additional tool for rupture prediction may provide a useful adjunct to the diameter-based approach in surgical decision-making.
Journal of Endovascular Therapy | 2008
David S. Molony; Anthony Callanan; Liam Morris; Barry J. Doyle; Michael T. Walsh; Timothy M. McGloughlin
Purpose: To compare the function of 2 stent-graft designs for endovascular abdominal aortic aneurysm repair. Methods: Computational fluid dynamics was used to investigate the performance of a conventional stent-graft versus one with a novel tapered configuration (equal area ratios at the inlet and bifurcation). Idealized geometries (uniplanar) were formed first for both devices. To mimic the clinical setting with pulsatile blood flow, a realistic model (multiplanar) was created for the conventional stent-graft based on computed tomography scans from 3 patients with different aortic geometries. A similar model was created for the tapered stent-graft by mimicking the deployment of the conventional stent-graft through its centerline. Results: The tapered stent-graft model demonstrated reduced secondary flow vortices and wall shear stresses in the iliac limbs compared to the conventional graft in the idealized scenario. The drag forces in the idealized models were similar for both designs, though the tapered stent-graft showed a 4% reduction. Flow was split more evenly between the tapered stent-graft limbs in the realistic scenario. Conclusion: The novel tapered design reduced flow velocities and secondary flows due to its smooth trunk-to-limb transition, while also splitting the flow between the iliac limbs more evenly. In multiplanar models, the out-of-plane curvature was the greatest cause of skewed flow, which reduced the benefits of the tapered stent-graft.
Journal of Endovascular Therapy | 2008
Timothy J. Corbett; Anthony Callanan; Liam G. Morris; Barry J. Doyle; Pierce A. Grace; Eamon G. Kavanagh; Timothy M. McGloughlin
Endovascular repair of abdominal aortic aneurysms has generated widespread interest since the procedure was first introduced two decades ago. It is frequently performed in patients who suffer from substantial comorbidities that may render them unsuitable for traditional open surgical repair. Although this minimally invasive technique substantially reduces operative risk, recovery time, and anesthesia usage in these patients, the endovascular method has been prone to a number of failure mechanisms not encountered with the open surgical method. Based on long-term results of second- and third-generation devices that are currently becoming available, this study sought to identify the most serious failure mechanisms, which may have a starting point in the morphological changes in the aneurysm and stent-graft. To investigate the “behavior” of the aneurysm after stent-graft repair, i.e., how its length, angulation, and diameter change, we utilized state-of-the-art ex vivo methods, which researchers worldwide are now using to recreate these failure modes.
Journal of Biomechanical Engineering-transactions of The Asme | 2010
Timothy J. Corbett; Barry J. Doyle; Anthony Callanan; Michael T. Walsh; Timothy M. McGloughlin
In vitro studies of abdominal aortic aneurysm (AAA) have been widely reported. Frequently mock artery models with intraluminal thrombus (ILT) analogs are used to mimic the in vivo AAA. While the models used may be physiological, their properties are frequently either not reported or investigated. This study is concerned with the testing and characterization of previously used vessel analog materials and the development of new materials for the manufacture of AAA models. These materials were used in conjunction with a previously validated injection molding technique to manufacture AAA models of ideal geometry. To determine the model properties (stiffness (beta) and compliance), the diameter change of each AAA model was investigated under incrementally increasing internal pressures and compared with published in vivo studies to determine if the models behaved physiologically. A FEA study was implemented to determine if the pressure-diameter change behavior of the models could be predicted numerically. ILT analogs were also manufactured and characterized. Ideal models were manufactured with ILT analog internal to the aneurysm region, and the effect of the ILT analog on the model compliance and stiffness was investigated. The wall materials had similar properties (E(init) 2.22 MPa and 1.57 MPa) to aortic tissue at physiological pressures (1.8 MPa (from literature)). ILT analogs had a similar Youngs modulus (0.24 MPa and 0.33 MPa) to the medial layer of ILT (0.28 MPa (from literature)). All models had aneurysm sac compliance (2.62-8.01 x 10(-4)/mm Hg) in the physiological range (1.8-9.4 x 10(-4)/mm Hg (from literature)). The necks of the AAA models had similar stiffness (20.44-29.83) to healthy aortas (17.5+/-5.5 (from literature)). Good agreement was seen between the diameter changes due to pressurization in the experimental and FEA wall models with a maximum difference of 7.3% at 120 mm Hg. It was also determined that the inclusion of ILT analog in the sac of the models could have an effect on the compliance of the model neck. Ideal AAA models with physiological properties were manufactured. The behavior of these models due to pressurization was predicted using finite element analysis, validating this technique for the future design of realistic physiological AAA models. Addition of ILT analogs in the aneurysm sac was shown to affect neck behavior. This could have implications for endovascular AAA repair due to the importance of the neck for stent-graft fixation.
Journal of The Mechanical Behavior of Biomedical Materials | 2016
Grand Roman Joldes; Karol Miller; Adam Wittek; Barry J. Doyle
Abdominal aortic aneurysm (AAA) is a permanent and irreversible dilation of the lower region of the aorta. It is a symptomless condition that if left untreated can expand to the point of rupture. Mechanically-speaking, rupture of an artery occurs when the local wall stress exceeds the local wall strength. It is therefore desirable to be able to non-invasively estimate the AAA wall stress for a given patient, quickly and reliably. In this paper we present an entirely new approach to computing the wall tension (i.e. the stress resultant equal to the integral of the stresses tangent to the wall over the wall thickness) within an AAA that relies on trivial linear elastic finite element computations, which can be performed instantaneously in the clinical environment on the simplest computing hardware. As an input to our calculations we only use information readily available in the clinic: the shape of the aneurysm in-vivo, as seen on a computed tomography (CT) scan, and blood pressure. We demonstrate that tension fields computed with the proposed approach agree well with those obtained using very sophisticated, state-of-the-art non-linear inverse procedures. Using magnetic resonance (MR) images of the same patient, we can approximately measure the local wall thickness and calculate the local wall stress. What is truly exciting about this simple approach is that one does not need any information on material parameters; this supports the development and use of patient-specific modelling (PSM), where uncertainty in material data is recognised as a key limitation. The methods demonstrated in this paper are applicable to other areas of biomechanics where the loads and loaded geometry of the system are known.
Medical Engineering & Physics | 2009
Barry J. Doyle; Timothy J. Corbett; Aidan J. Cloonan; Michael R. O’Donnell; Michael T. Walsh; David A. Vorp; Timothy M. McGloughlin
A range of silicone rubbers were created based on existing commercially available materials. These silicones were designed to be visually different from one another and have distinct material properties, in particular, ultimate tensile strengths and tear strengths. In total, eleven silicone rubbers were manufactured, with the materials designed to have a range of increasing tensile strengths from approximately 2 to 4 MPa, and increasing tear strengths from approximately 0.45 to 0.7 N/mm. The variations in silicones were detected using a standard colour analysis technique. Calibration curves were then created relating colour intensity to individual material properties. All eleven materials were characterised and a 1st order Ogden strain energy function applied. Material coefficients were determined and examined for effectiveness. Six idealised abdominal aortic aneurysm models were also created using the two base materials of the study, with a further model created using a new mixing technique to create a rubber model with randomly assigned material properties. These models were then examined using videoextensometry and compared to numerical results. Colour analysis revealed a statistically significant linear relationship (p<0.0009) with both tensile strength and tear strength, allowing material strength to be determined using a non-destructive experimental technique. The effectiveness of this technique was assessed by comparing predicted material properties to experimentally measured methods, with good agreement in the results. Videoextensometry and numerical modelling revealed minor percentage differences, with all results achieving significance (p<0.0009). This study has successfully designed and developed a range of silicone rubbers that have unique colour intensities and material strengths. Strengths can be readily determined using a non-destructive analysis technique with proven effectiveness. These silicones may further aid towards an improved understanding of the biomechanical behaviour of aneurysms using experimental techniques.