Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Barry K. Rayburn is active.

Publication


Featured researches published by Barry K. Rayburn.


JAMA | 2005

Evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness

James A. Hill; Daniel F. Pauly; Debra R. Olitsky; Stuart D. Russell; Christopher M. O'Connor; Beth Patterson; Uri Elkayam; Salman Khan; Lynne W. Stevenson; Kimberly Brooks; Lynne E. Wagoner; Ginger Conway; Todd M. Koelling; Carol Van Huysen; Joshua M. Hare; Elayne Breton; Kirkwood F. Adams; Jana M. Glotzer; Gregg C. Fonarow; Michele A. Hamilton; Julie M. Sorg; Mark H. Drazner; Shannon Hoffman; Leslie W. Miller; Judith A. Graziano; Mary Ellen Berman; Robert P. Frantz; Karen A. Hartman; Carl V. Leier; William T. Abraham

CONTEXT Pulmonary artery catheters (PACs) have been used to guide therapy in multiple settings, but recent studies have raised concerns that PACs may lead to increased mortality in hospitalized patients. OBJECTIVE To determine whether PAC use is safe and improves clinical outcomes in patients hospitalized with severe symptomatic and recurrent heart failure. DESIGN, SETTING, AND PARTICIPANTS The Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness (ESCAPE) was a randomized controlled trial of 433 patients at 26 sites conducted from January 18, 2000, to November 17, 2003. Patients were assigned to receive therapy guided by clinical assessment and a PAC or clinical assessment alone. The target in both groups was resolution of clinical congestion, with additional PAC targets of a pulmonary capillary wedge pressure of 15 mm Hg and a right atrial pressure of 8 mm Hg. Medications were not specified, but inotrope use was explicitly discouraged. MAIN OUTCOME MEASURES The primary end point was days alive out of the hospital during the first 6 months, with secondary end points of exercise, quality of life, biochemical, and echocardiographic changes. RESULTS Severity of illness was reflected by the following values: average left ventricular ejection fraction, 19%; systolic blood pressure, 106 mm Hg; sodium level, 137 mEq/L; urea nitrogen, 35 mg/dL (12.40 mmol/L); and creatinine, 1.5 mg/dL (132.6 micromol/L). Therapy in both groups led to substantial reduction in symptoms, jugular venous pressure, and edema. Use of the PAC did not significantly affect the primary end point of days alive and out of the hospital during the first 6 months (133 days vs 135 days; hazard ratio [HR], 1.00 [95% confidence interval {CI}, 0.82-1.21]; P = .99), mortality (43 patients [10%] vs 38 patients [9%]; odds ratio [OR], 1.26 [95% CI, 0.78-2.03]; P = .35), or the number of days hospitalized (8.7 vs 8.3; HR, 1.04 [95% CI, 0.86-1.27]; P = .67). In-hospital adverse events were more common among patients in the PAC group (47 [21.9%] vs 25 [11.5%]; P = .04). There were no deaths related to PAC use, and no difference for in-hospital plus 30-day mortality (10 [4.7%] vs 11 [5.0%]; OR, 0.97 [95% CI, 0.38-2.22]; P = .97). Exercise and quality of life end points improved in both groups with a trend toward greater improvement with the PAC, which reached significance for the time trade-off at all time points after randomization. CONCLUSIONS Therapy to reduce volume overload during hospitalization for heart failure led to marked improvement in signs and symptoms of elevated filling pressures with or without the PAC. Addition of the PAC to careful clinical assessment increased anticipated adverse events, but did not affect overall mortality and hospitalization. Future trials should test noninvasive assessments with specific treatment strategies that could be used to better tailor therapy for both survival time and survival quality as valued by patients.


Journal of the American College of Cardiology | 2003

Beraprost Therapy for Pulmonary Arterial Hypertension

Robyn J. Barst; Michael D. McGoon; Vallerie V. McLaughlin; Victor F. Tapson; Ronald J. Oudiz; Shelley Shapiro; Ivan M. Robbins; Richard N. Channick; David B. Badesch; Barry K. Rayburn; Robin Flinchbaugh; Jeff Sigman; Rogers Jeffs

OBJECTIVES The purpose of this study was to assess the safety and efficacy of the oral prostacyclin analogue beraprost sodium during a 12-month double-blind, randomized, placebo-controlled trial in patients with pulmonary arterial hypertension (PAH). BACKGROUND Pulmonary arterial hypertension is a progressive disease that ultimately causes right heart failure and death. Despite the risks from its delivery system, continuous intravenous epoprostenol remains the most efficacious treatment currently available. METHODS A total of 116 patients with World Health Organization (WHO) functional class II or III primary pulmonary hypertension or PAH related to either collagen vascular diseases or congenital systemic to pulmonary shunts were enrolled. Patients were randomized to receive the maximal tolerated dose of beraprost sodium (median dose 120 microg four times a day) or placebo for 12 months. The primary end point was disease progression; i.e., death, transplantation, epoprostenol rescue, or >25% decrease in peak oxygen consumption (VO(2)). Secondary end points included exercise capacity assessed by 6-min walk test and peak VO(2), Borg dyspnea score, hemodynamics, symptoms of PAH, and quality of life. RESULTS Patients treated with beraprost exhibited less evidence of disease progression at six months (p = 0.002), but this effect was not evident at either shorter or longer follow-up intervals. Similarly, beraprost-treated patients had improved 6-min walk distance at 3 months by 22 m from baseline and at 6 months by 31 m (p = 0.010 and 0.016, respectively) compared with placebo, but not at either 9 or 12 months. Drug-related adverse events were common and were related to the disease and/or expected prostacyclin adverse events. CONCLUSIONS These data suggest that beneficial effects may occur during early phases of treatment with beraprost in WHO functional class II or III patients but that this effect attenuates with time.


Journal of Heart and Lung Transplantation | 1999

Are preoperative obesity and cachexia risk factors for post heart transplant morbidity and mortality: a multi-institutional study of preoperative weight-height indices

Kathleen L. Grady; Connie White-Williams; D. C. Naftel; Maria Rosa Costanzo; Douglas Pitts; Barry K. Rayburn; Adrian VanBakel; Brian E. Jaski; Robert C. Bourge; Kirklin Jk

BACKGROUND The relationship between pre-transplant body weight and post-transplant outcome has only recently been identified using a single, indirect measure of weight (percent ideal body weight [PIBW]). The literature is equivocal regarding which index is the better indicator of body weight. The purpose of this study was to determine (1) if pre-heart transplant body weight, measured by body mass index (BMI) and PIBW, is associated with post-heart transplant morbidity and mortality and (2) if patient gender, age, and etiology of heart disease affect this association. METHODS The sample included 4,515 patients who received a heart transplant from January 1, 1990-December 31, 1995 at 38 institutions participating in the Cardiac Transplant Research Database (CTRD). Patients were divided into groups according to their BMI and PIBW. Data were described using frequencies, measures of central tendency, Pearson correlation coefficients, stratified actuarial analyses and log rank tests for comparisons, and a multivariable risk factor analysis in the hazard domain. RESULTS For all patients (n = 4,515), being <80% or >140% of IBW before heart transplant was a risk factor for increased mortality after heart transplant. The association between pre-heart transplant PIBW and post-heart transplant survival was affected by gender, age, and etiology of heart disease. In males, a higher PIBW was a significant risk factor for death early after transplant (p = .0003). Although not significant, there was a trend for a higher PIBW being a risk factor for death in females throughout the post transplant period (p = .07). No differences in cause of death were found for PIBW and BMI. In male and female recipients <55 years, being overweight pre-heart transplant was a risk factor for infection. In patients with pre-transplant ischemic heart disease, the greatest risk for infection was found in patients who were >140% of IBW. Pre-heart transplant BMI and PIBW were not associated with acute rejection or cardiac allograft arteriopathy after transplant. CONCLUSIONS In conclusion, being cachectic or obese preoperatively is associated with decreased survival in all patients after heart transplantation. Being obese preoperatively is associated with increased infection after heart transplant in males and females <55 years and in patients with ischemic heart disease. Of the 2 indices of body weight used in this study, percent ideal body weight appears to be the better predictor of future morbidity and mortality following heart transplantation.


The Annals of Thoracic Surgery | 2003

Infection in ventricular assist devices: prevention and treatment

William L. Holman; Barry K. Rayburn; David C. McGiffin; Brian A. Foley; Raymond L. Benza; Robert C. Bourge; Laura J. Pinderski; James K. Kirklin

Infection is one of the most important challenges to the use of implanted mechanical circulatory support systems (MCSS), particularly as we enter the era of permanent device use in patients who are not candidates for cardiac transplantation. This paper describes the pathogenesis of MCSS infection, with particular attention to the role of biofilm-forming bacteria. Suggestions are presented for the prevention and treatment of infections in implanted MCSS.


Transplantation | 1999

Safety, tolerability, and efficacy of cyclosporine microemulsion in heart transplant recipients: A randomized, multicenter, double-blind comparison with the oil-based formulation of cyclosporine: Results at 24 months after transplantation

Howard J. Eisen; R E Hobbs; S. Davis; M Carrier; Donna Mancini; Andrew L. Smith; Hannah A. Valantine; H.O. Ventura; Mandeep R. Mehra; Jean-Luc Vachiery; Barry K. Rayburn; C C Canver; G Laufer; Maria Rosa Costanzo; J Copeland; Georges Dureau; O H Frazier; Richard Dorent; Paul J. Hauptman; R Masters; J L Michaud; I Paradis; Dale G. Renlund; J Vanhaecke; B. Mellein; E A Mueller

BACKGROUND The widespread use of cyclosporine has improved the survival of cardiac transplant patients as a result of reduced morbidity and mortality from rejection and infection. The original oil-based form of cyclosporine demonstrated unpredictable absorption resulting in an increased frequency of acute and chronic rejection in patients with poor bioavailability. The primary end. points of the present, prospective, randomized multicenter, double-blind trial were to compare the efficacy of the micro-emulsion form of cycolsporine (CsA-NL) with the oil-based formulation as determined by cardiac allograft and recipient survival and the incidence and severity of the acute rejection episodes and to determine the safety and tolerability of CsA-NL compared with Sandimmune CsA-(SM) in the study population. The 6-month analysis of the study showed reduced number of CsA-NL patients requiring antilymphocyte antibody therapy for rejection, fewer International Society of Heart and Lung Transplantation grade > or =3A rejections in female patients and fewer infections. Our report represents the final analysis of the results 24 months after transplantation. METHODS A total of 380 patients undergoing de novo cardiac transplants at 24 centers in the United States, Canada, and Europe were enrolled in this double-blind, randomized trial evaluating the efficacy and safety of CsA-NL versus CsA-SM. Acute allograft rejection was diagnosed by endomyocardial biopsy and graded according to the International Society of Heart and Lung Transplantation nomenclature. Kaplan-Meier analysis and Fishers exact test were used for comparisons between groups. RESULTS After 24 months, allograft and recipient survival were identical in both groups. There were fewer CsA-NL patients (6.9%) requiring antilymphocyte antibody therapy for rejection than in the CsA-SM-treated patient group (17.7%, P=0.002). There were fewer discontinuations of study drug for treatment failures in the CsA-NL groups (7; 3.7%) compared with the CsA-SM group (18; 9.4%, P=0.037). The average corticosteroid dose was lower in the CsA-NL group (0.37 mg/kg/day) compared with the CsA-SM group (0.48 mg/kg/day, P=0.034) over the 24-month study period. Overall, there was no difference in blood pressure or creatinine between the two study groups. CONCLUSIONS The final results of this multi-center, randomized study of two forms of cyclosporine confirmed that there were fewer episodes of rejection requiring antilymphocyte antibodies and fewer study discontinuations for treatment failures in CsA-NL-treated patients compared to those treated with CsA-SM. The use of CsA-NL did not predispose these patients to a higher risk of adverse events.


The Journal of Thoracic and Cardiovascular Surgery | 2008

Worldwide surgical experience with the Paracor HeartNet cardiac restraint device

Charles T. Klodell; Juan M. Aranda; David C. McGiffin; Barry K. Rayburn; Benjamin Sun; William T. Abraham; Walter E. Pae; John Boehmer; Helmut U. Klein; Christof Huth

OBJECTIVE An elastic ventricular restraint device has been developed for patients with heart failure who remain symptomatic despite treatment with standard therapies. The safety and efficacy of this device are under clinical investigation. Six-month data for the first 51 patients treated worldwide are reported. We hypothesize that the Paracor HeartNet device (Paracor Medical, Sunnyvale, Calif), placed through a minithoracotomy in patients with severe dilated cardiomyopathy, improves clinical and functional status. METHODS Fifty-one patients with an ejection fraction of 35% or less, with a New York Heart Association class II or III, and receiving optimal medical therapy for at least 3 months, were selected at 15 sites (3 in Europe, 12 in the United States) to undergo implantation of the HeartNet device through a minithoracotomy. Patients were evaluated at baseline and at 6-month follow-up by echocardiography, the 6-minute walk test, cardiopulmonary exercise testing (partial oxygen pressure in mixed venous blood), New York Heart Association class, and (in the United States) the Minnesota Living with Heart Failure questionnaire. RESULTS The average age was 52 years (30-73 years), with a preponderance of men and nonischemic cause of heart failure. Implantation was accomplished in 50 of 51 patients (98%). Adverse events included 2 in-hospital deaths secondary to pulmonary complications (4%), additional pulmonary complications in 7 patients (14%), arrhythmia in 14 patients (27%), epicardial laceration in 2 patients (4%), and empyema in 1 patient (2%). Six-month data demonstrated significant improvement in the 6-minute walk test (+65.7, P = .002) and Minnesota Living with Heart Failure scores (-15.7, P = .002) and improvement in echocardiographic findings. CONCLUSION The Paracor HeartNet device can be reliably implanted in patients with heart failure and marked reduction of left ventricular function. These data suggest a functional and clinical benefit, with a trend toward reverse remodeling, and support the conduct of a randomized controlled pivotal trial.


Chest | 2008

Treprostinil-Based Therapy in the Treatment of Moderate-to-Severe Pulmonary Arterial Hypertension: Long-term Efficacy and Combination With Bosentan

Raymond L. Benza; Barry K. Rayburn; Jose A. Tallaj; Salpy V. Pamboukian; Robert C. Bourge

BACKGROUND Treprostinil, a long-acting prostacyclin analog, diminished the symptoms of pulmonary arterial hypertension (PAH) in controlled 12-week clinical efficacy studies. This retrospective, single-center, open-label study was designed to assess the efficacy of long-term, subcutaneously administered, treprostinil-based therapy alone or in combination with bosentan for the treatment of moderate-to-severe PAH. METHODS Thirty-eight patients with pulmonary hypertension treated with subcutaneous treprostinil were followed up for a mean (+/-SD) duration of 984+/-468 days (range, 165 to 1,847 days). Oral bosentan was added to the treprostinil regimen if patients remained in New York Heart Association (NYHA) functional class III or II with intolerable prostacyclin side effects that limited therapy. Hemodynamic studies, Borg dyspnea score evaluations, 6-min walk (6MW) tests, and NYHA functional class determinations were performed at approximately 6-month intervals. RESULTS Mean pulmonary artery pressure decreased from 59.7 to 50.5 mm Hg (p<0.001). Significant and sustained improvement in 6MW distance (p=0.022) and Borg dyspnea score (p=0.023) were observed. At the final observation, the mean dose of treprostinil was 37.8 ng/kg/min (range, 7.5 to 115 ng/kg/min). At baseline, 5% of patients were in NYHA functional class 2 or lower vs 58% at the last follow-up. Bosentan was added to the regimens of 19 patients. In those patients, significant additional improvement occurred in the pulmonary arterial pressure (p<0.001), 6MW distance (p=0.001), and Borg dyspnea scale (p=0.020) compared to baseline. CONCLUSIONS Long-term treatment with subcutaneous treprostinil-based therapy improved functional parameters and hemodynamics in patients with moderate-to-severe PAH. In patients requiring combination therapy, the addition of oral bosentan to treprostinil-based therapy was safe, well-tolerated, and associated with further clinical improvements.


Journal of Cardiac Failure | 1998

The relationship between cardiac function and neuropsychological status among heart transplant candidates

John D. Putzke; Mark A. Williams; Barry K. Rayburn; James K. Kirklin; Thomas J. Boll

BACKGROUND Cognitive deficits among heart transplant candidates have been well documented. This study was designed to examine the hypothesis that impaired cognitive test performance among heart transplant candidates may be attributed, in part, to decreased cerebral perfusion secondary to poor cardiac function. METHODS AND RESULTS Sixty-two patients participated in the study who underwent heart catheterization within 1 day of completing a battery of cognitive tests. Multiple demographic and patient characteristics were examined for their potential moderating role in the relationship between measures of cardiac function and cognitive performance including age, education, race, gender, psychiatric history, medication usage, cardiac surgical history, and self-reported symptoms of depression and anxiety. Only age and education were significantly related to cognitive performance (P < .01). Thus, partial correlation analyses controlling for age and education were used to examine the relationship between cardiac function and cognitive performance. In general, increasing hemodynamic pressure variables (ie, pulmonary artery pressure and right atrial pressure), and to a lesser extent cardiac output and cardiac index, were related (r = - .32 to - .43; P < .01) to decreased performance on cognitive tasks that assessed simple attention, speed of mental processing, and mental flexibility (Digit Span-Forward, Trail Making Test-Part B, Symbol Digits Modalities Test, and Stroop Neuropsychological Screening Test). Left ventricular ejection fraction, systemic and pulmonary vascular resistance, and mean arterial pressure were largely unrelated to cognitive performance in this sample of patients with end stage cardiac disease. CONCLUSIONS Hemodynamic pressure variables seem to be most consistently related (ie, inversely) to cognitive functioning among heart transplant candidates.


The Annals of Thoracic Surgery | 2002

Treatment of end-stage heart disease with outpatient ventricular assist devices

William L. Holman; James E. Davies; Barry K. Rayburn; David C. McGiffin; Brian A. Foley; Raymond L. Benza; Robert C. Bourge; Peggy Blood; James K. Kirklin

BACKGROUND Initiating outpatient therapy with ventricular assist devices (VAD) was important in the progress of mechanical circulatory support. This article reviews our experience with VAD therapy from the start of our outpatient program until the present. METHODS Medical records of patients who received a Thoratec para-corporeal VAD, HeartMate vented electrical VAD, or HeartMate pneumatic VAD between 12/1/97 and 9/1/01 were reviewed. Variables included age, type of devices, total duration of VAD support, discharge status, duration of outpatient support, outcome (transplanted, died on support, ongoing), in-hospital length of stay after transplantation, and complications during VAD support. RESULTS There were 53 device implants in 46 patients. The cumulative patient-days of VAD support was 7,468 (mean duration of support, 138 +/- 195 days; median, 95 days; range, 2 to 948 days). Twenty of the 46 patients were discharged with a VAD. The cumulative outpatient days was 3,600 (mean outpatient duration, 157 +/- 164 days; median, 83 days; maximum, 560 days). Of the 20 outpatients, 11 received cardiac transplantation, 5 died, and 4 are ongoing as of 9/1/01. Major complications that occurred in the outpatient setting included 5 deaths after hospital readmission (1 sepsis, 1 conduit tear, 3 neurologic events); 4 device infections (3 sepsis, 1 pouch infection); and 3 device malfunctions that required reoperation for pump replacement (1 HeartMate pneumatic and 2 HeartMate vented electrical). No deaths occurred in an outpatient setting. CONCLUSIONS Ventricular assist devices effectively support outpatients for months to years. The anticipated time for postoperative recovery and VAD training before discharge is approximately 14 to 21 days, although shorter times may be possible in the future. Establishing a successful outpatient VAD program is a crucial step toward VAD as definitive therapy for end-stage heart disease.


The Annals of Thoracic Surgery | 1999

Management of wound and left ventricular assist device pocket infection

William L. Holman; R.Jobe Fix; Brian A. Foley; David C. McGiffin; Barry K. Rayburn; James K. Kirklin

Our patient developed a wound infection that involved an implanted left ventricular assist device. At surgery, the pump was washed with a detergent-containing bacteriocidal solution, then antibiotic-impregnated polymethylmethacrylate beads were placed around the pump. The wound was revised using rectus muscle to cover the pump. The incisions have healed and the patient is now at home. She is on no systemic antibiotics and has no evidence of infection 11 months postoperatively.

Collaboration


Dive into the Barry K. Rayburn's collaboration.

Top Co-Authors

Avatar

Robert C. Bourge

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar

Raymond L. Benza

Allegheny General Hospital

View shared research outputs
Top Co-Authors

Avatar

Jose A. Tallaj

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar

James K. Kirklin

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Brian A. Foley

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar

Laura J. Pinderski

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar

Salpy V. Pamboukian

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar

Robert N. Brown

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge