Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Batur Ercan is active.

Publication


Featured researches published by Batur Ercan.


Nanotechnology | 2011

Diameter of titanium nanotubes influences anti-bacterial efficacy

Batur Ercan; Erik N. Taylor; Ece Alpaslan; Thomas J. Webster

Bacterial infection of in-dwelling medical devices is a growing problem that cannot be treated by traditional antibiotics due to the increasing prevalence of antimicrobial resistance and biofilm formation. Here, due to changes in surface parameters, it is proposed that bacterial adhesion can be prevented through nanosurface modifications of the medical device alone. Toward this goal, titanium was created to possess nanotubular surface topographies of highly controlled diameters of 20, 40, 60, or 80 nm, sometimes followed by heat treatment to control chemistry and crystallinity, through a novel anodization process. For the first time it was found that through the control of Ti surface parameters including chemistry, crystallinity, nanotube size, and hydrophilicity, significantly changed responses of both Staphylococcus epidermidis and Staphylococcus aureus (pathogens relevant for orthopaedic and other medical device related infections) were measured. Specifically, heat treatment of 80 nm diameter titanium tubes produced the most robust antimicrobial effect of all surface treatment parameters tested. This study provides the first step toward understanding the surface properties of nano-structured titanium that improve tissue growth (as has been previously observed with nanotubular titanium), while simultaneously reducing infection without the use of pharmaceutical drugs.


Acta Biomaterialia | 2011

Decreased Staphylococcus aureus biofilm growth on anodized nanotubular titanium and the effect of electrical stimulation.

Batur Ercan; Kim M. Kummer; Keiko M. Tarquinio; Thomas J. Webster

Infection is a major problem in orthopedics leading to implant failure. It is a challenging task to treat orthopedic implant infection, which may lead to implant replacement and, in severe cases, may result in amputation and mortality. Infection poses an even further risk as bacteria are beginning to develop resistance against commonly used antibiotics. Therefore, in this research a combination of various approaches was used to fight implant infection without resorting to the use of antibiotics. Specifically, conventional titanium was altered through a process of anodization and electrical stimulation to reduce Staphylococcus aureus growth. It was shown that when a 15-30 V electrical stimulation was coupled with anodized nanotubular titanium a significant decrease in S. aureus biofilm formation was observed, compared with non-anodized and non-electrically stimulated titanium after 2 days culture. The decrease in biofilm formation observed here was explained by the presence of fluorine on the surfaces of anodized nanotubular titanium. Thus, coupling the positive influences of anodization and electrical stimulation could be a promising way to fight titanium-based orthopedic device-related infections.


International Journal of Nanomedicine | 2012

Decreased Bacteria Activity on Si3N4 Surfaces Compared with PEEK Or Titanium

Deborah J Gorth; Sabrina Puckett; Batur Ercan; Thomas J. Webster; Mohamed N. Rahaman; B. Sonny Bal

A significant need exists for orthopedic implants that can intrinsically resist bacterial colonization. In this study, three biomaterials that are used in spinal implants – titanium (Ti), polyether-ether-ketone (PEEK), and silicon nitride (Si3N4) – were tested to understand their respective susceptibility to bacterial infection with Staphylococcus epidermidis, Staphlococcus aureus, Pseudomonas aeruginosa, Escherichia coli and Enterococcus. Specifically, the surface chemistry, wettability, and nanostructured topography of respective biomaterials, and the effects on bacterial biofilm formation, colonization, and growth were investigated. Ti and PEEK were received with as-machined surfaces; both materials are hydrophobic, with net negative surface charges. Two surface finishes of Si3N4 were examined: as-fired and polished. In contrast to Ti and PEEK, the surface of Si3N4 is hydrophilic, with a net positive charge. A decreased biofilm formation was found, as well as fewer live bacteria on both the as-fired and polished Si3N4. These differences may reflect differential surface chemistry and surface nanostructure properties between the biomaterials tested. Because protein adsorption on material surfaces affects bacterial adhesion, the adsorption of fibronectin, vitronectin, and laminin on Ti, PEEK, and Si3N4 were also examined. Significantly greater amounts of these proteins adhered to Si3N4 than to Ti or PEEK. The findings of this study suggest that surface properties of biomaterials lead to differential adsorption of physiologic proteins, and that this phenomenon could explain the observed in-vitro differences in bacterial affinity for the respective biomaterials. Intrinsic biomaterial properties as they relate to resistance to bacterial colonization may reflect a novel strategy toward designing future orthopedic implants.


Biomaterials | 2010

The effect of biphasic electrical stimulation on osteoblast function at anodized nanotubular titanium surfaces.

Batur Ercan; Thomas J. Webster

Over the past decade, nanotechnology (or the use of materials with dimensions less than 100 nm in at least one direction) has been proposed to improve the lifespan of many biomedical devices, including orthopedic implants. Specifically, to improve the cytocompatibility properties of currently used orthopedic implants, nanotechnology has been used to create nanometer surface features (through anodization) on titanium. In addition to this approach, another therapeutic method widely investigated to heal bone fractures is through electrical stimulation. Here, the coupling of such nanotechnology approaches and electrical stimulation were studied to maximize bone cell functions on titanium. Results showed that compared to unstimulated conventional titanium, bone forming cell (osteoblast) proliferation and long-term functions (alkaline phosphatase synthesis, collagen type I synthesis and calcium deposition) were improved upon both the creation of an anodized nanotubular titanium surface and biphasic electrical stimulation. Most importantly, when electrical stimulation was combined with anodized nanotubular titanium features, osteoblast long-term functions were improved the most. Therefore, coupling the positive effects of anodized nanotubular titanium topographies with currently used therapeutic electrical stimulation should be further studied to improve orthopedic implants.


International Journal of Nanomedicine | 2009

Nanofunctionalized zirconia and barium sulfate particles as bone cement additives

Riaz Gillani; Batur Ercan; Alex Qiao; Thomas J. Webster

Zirconia (ZrO2) and barium sulfate (BaSO4) particles were introduced into a methyl methacrylate monomer (MMA) solution with polymethyl methacrylate (PMMA) beads during polymerization to develop the following novel bone cements: bone cements with unfunctionalized ZrO2 micron particles, bone cements with unfunctionalized ZrO2 nanoparticles, bone cements with ZrO2 nanoparticles functionalized with 3-(trimethoxysilyl)propyl methacrylate (TMS), bone cements with unfunctionalized BaSO4 micron particles, bone cements with unfunctionalized BaSO4 nanoparticles, and bone cements with BaSO4 nanoparticles functionalized with TMS. Results demonstrated that in vitro osteoblast (bone-forming cell) densities were greater on bone cements containing BaSO4 ceramic particles after four hours compared to control unmodified bone cements. Osteoblast densities were also greater on bone cements containing all of the ceramic particles after 24 hours compared to unmodified bone cements, particularly those bone cements containing nanofunctionalized ceramic particles. Bone cements containing ceramic particles demonstrated significantly altered mechanical properties; specifically, under tensile loading, plain bone cements and bone cements containing unfunctionalized ceramic particles exhibited brittle failure modes whereas bone cements containing nanofunctionalized ceramic particles exhibited plastic failure modes. Finally, all bone cements containing ceramic particles possessed greater radio-opacity than unmodified bone cements. In summary, the results of this study demonstrated a positive impact on the properties of traditional bone cements for orthopedic applications with the addition of unfunctionalized and TMS functionalized ceramic nanoparticles.


International Journal of Nanomedicine | 2011

Reduced adhesion of macrophages on anodized titanium with select nanotube surface features

Amancherla Rajyalakshmi; Batur Ercan; K Balasubramanian; Thomas J. Webster

One of the important prerequisites for a successful orthopedic implant apart from being osteoconductive is the elicitation of a favorable immune response that does not lead to the rejection of the implant by the host tissue. Anodization is one of the simplest surface modification processes used to create nanotextured and nanotubular features on metal oxides which has been shown to improve bone formation. Anodization of titanium (Ti) leads to the formation of TiO2 nanotubes on the surface, and the presence of these nanotubes mimics the natural nanoscale features of bone, which in turn contributes to improved bone cell attachment, migration, and proliferation. However, inflammatory cell responses on anodized Ti remains to be tested. It is hypothesized that surface roughness and surface feature size on anodized Ti can be carefully manipulated to control immune cell (specifically, macrophages) responses. Here, when Ti samples were anodized at 10 V in the presence of 1% hydrofluoric acid (HF) for 1 minute, nanotextured (nonnanotube) surfaces were created. When anodization of Ti samples was carried out with 1% HF for 10 minutes at 15 V, nanotubes with 40–50 nm diameters were formed, whereas at 20 V with 1% HF for 10 minutes, nanotubes with 60–70 nm diameters were formed. In this study, a reduced density of macrophages was observed after 24 hours of culture on nanotextured and nanotubular Ti samples which were anodized at 10, 15, and 20 V, compared with conventional unmodified Ti samples. This in vitro study thus demonstrated a reduced density of macrophages on anodized Ti, thereby providing further evidence of the greater efficacy of anodized Ti for orthopedic applications.


International Journal of Nanomedicine | 2008

Greater osteoblast proliferation on anodized nanotubular titanium upon electrical stimulation

Batur Ercan; Thomas J. Webster

Currently used orthopedic implants composed of titanium have a limited functional lifetime of only 10–15 years. One of the reasons for this persistent problem is the poor prolonged ability of titanium to remain bonded to juxtaposed bone. It has been proposed to modify titanium through anodization to create a novel nanotubular topography in order to improve cytocompatibility properties necessary for the prolonged attachment of orthopedic implants to surrounding bone. Additionally, electrical stimulation has been used in orthopedics to heal bone non-unions and fractures in anatomically difficult to operate sites (such as the spine). In this study, these two approaches were combined as the efficacy of electrical stimulation to promote osteoblast (bone forming cell) density on anodized titanium was investigated. To do this, osteoblast proliferation experiments lasting up to 5 days were conducted as cells were stimulated with constant bipolar pulses at a frequency of 20 Hz and a pulse duration of 0.4 ms each day for 1 hour. The stimulation voltages were 1 V, 5 V, 10 V, and 15 V. Results showed for the first time that under electrical stimulation, osteoblast proliferation on anodized titanium was enhanced at lower voltages compared to what was observed on conventional (nonanodized) titanium. In addition, compared to nonstimulated conventional titanium, osteoblast proliferation was enhanced 72% after 5 days of culture on anodized nanotubular titanium at 15 V of electrical stimulation. Thus, results of this study suggest that coupling the positive influences of electrical stimulation and nanotubular features on anodized titanium may improve osteoblast responses necessary for enhanced orthopedic implant efficacy.


Acta Biomaterialia | 2015

Adding MgO nanoparticles to hydroxyapatite–PLLA nanocomposites for improved bone tissue engineering applications

Daniel J. Hickey; Batur Ercan; Linlin Sun; Thomas J. Webster

Magnesium plays an important role in the body, mediating cell-extracellular matrix interactions and bone apatite structure and density. This study investigated, for the first time, the effects of adding magnesium oxide (MgO) nanoparticles to poly (l-lactic acid) (PLLA) and to hydroxyapatite (HA) nanoparticle-PLLA composites for orthopedic tissue engineering applications. Results showed that MgO nanoparticles significantly enhanced osteoblast adhesion and proliferation on HA-PLLA nanocomposites while maintaining mechanical properties (Youngs modulus ∼1,000 MPa) suitable for cancellous bone applications. Additionally, osteoblasts (or bone-forming cells) cultured in the supernatant of degrading nanocomposites showed improved proliferation in the presence of magnesium, indicating that the increased alkalinity of solutions containing MgO nanocomposites had no toxic effects towards cells. These results together indicated the promise of further studying MgO nanoparticles as additive materials to polymers to enhance the integration of implanted biomaterials with bone.


Journal of Biomedical Materials Research Part B | 2013

Effects of different sterilization techniques and varying anodized TiO2 nanotube dimensions on bacteria growth

Kim M. Kummer; Erik N. Taylor; Naside G. Durmas; Keiko M. Tarquinio; Batur Ercan; Thomas J. Webster

Infection of titanium (Ti)-based orthopedic implants is a growing problem due to the ability of bacteria to develop a resistance to todays antibiotics. As an attempt to develop a new strategy to combat bacteria functions, Ti was anodized in the present study to possess different diameters of nanotubes. It is reported here for the first time that Ti anodized to possess 20 nm tubes then followed by heat treatment to remove fluorine deposited from the HF anodization electrolyte solution significantly reduced both S. aureus and S. epidermidis growth compared to unanodized Ti controls. It was further found that the sterilization method used for both anodized nanotubular Ti and conventional Ti played an important role in the degree of bacteria growth on these substrates. Overall, UV light and ethanol sterilized samples decreased bacteria growth, while autoclaving resulted in the highest amount of bacteria growth. In summary, this study indicated that through a simple and inexpensive process, Ti can be anodized to possess 20 nm tubes that no matter how sterilized (UV light, ethanol soaking, or autoclaving) reduces bacteria growth and, thus, shows great promise as an antibacterial implant material.


International Journal of Nanomedicine | 2014

Decreased Staphylococcus aureus and increased osteoblast density on nanostructured electrophoretic-deposited hydroxyapatite on titanium without the use of pharmaceuticals.

Dennis Mathew; Garima Bhardwaj; Qi Wang; Linlin Sun; Batur Ercan; Manisavagam Geetha; Thomas J. Webster

Background Plasma-spray deposition of hydroxyapatite on titanium (Ti) has proven to be a suboptimal solution to improve orthopedic-implant success rates, as demonstrated by the increasing number of orthopedic revision surgeries due to infection, implant loosening, and a myriad of other reasons. This could be in part due to the high heat involved during plasma-spray deposition, which significantly increases hydroxyapatite crystal growth into the nonbiologically inspired micron regime. There has been a push to create nanotopographies on implant surfaces to mimic the physiological nanostructure of native bone and, thus, improve osteoblast (bone-forming cell) functions and inhibit bacteria functions. Among the several techniques that have been adopted to develop nanocoatings, electrophoretic deposition (EPD) is an attractive, versatile, and effective material-processing technique. Objective The in vitro study reported here aimed to determine for the first time bacteria responses to hydroxyapatite coated on Ti via EPD. Results There were six and three times more osteoblasts on the electrophoretic-deposited hydroxyapatite on Ti compared with Ti (control) and plasma-spray-deposited hydroxyapatite on Ti after 5 days of culture, respectively. Impressively, there were 2.9 and 31.7 times less Staphylococcus aureus on electrophoretic-deposited hydroxyapatite on Ti compared with Ti (control) and plasma-spray-deposited hydroxyapatite on Ti after 18 hours of culture, respectively. Conclusion Compared with uncoated Ti and plasma-sprayed hydroxyapatite coated on Ti, the results provided significant promise for the use of EPD to improve bone-cell density and be used as an antibacterial coating without resorting to the use of antibiotics.

Collaboration


Dive into the Batur Ercan's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Linlin Sun

Northeastern University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Luting Liu

Northeastern University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge