Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Beat Schmutz is active.

Publication


Featured researches published by Beat Schmutz.


Medical Engineering & Physics | 2011

Effects of CT image segmentation methods on the accuracy of long bone 3D reconstructions

Kanchana Rathnayaka; Tony Sahama; Michael Schuetz; Beat Schmutz

An accurate and accessible image segmentation method is in high demand for generating 3D bone models from CT scan data, as such models are required in many areas of medical research. Even though numerous sophisticated segmentation methods have been published over the years, most of them are not readily available to the general research community. Therefore, this study aimed to quantify the accuracy of three popular image segmentation methods, two implementations of intensity thresholding and Canny edge detection, for generating 3D models of long bones. In order to reduce user dependent errors associated with visually selecting a threshold value, we present a new approach of selecting an appropriate threshold value based on the Canny filter. A mechanical contact scanner in conjunction with a microCT scanner was utilised to generate the reference models for validating the 3D bone models generated from CT data of five intact ovine hind limbs. When the overall accuracy of the bone model is considered, the three investigated segmentation methods generated comparable results with mean errors in the range of 0.18-0.24 mm. However, for the bone diaphysis, Canny edge detection and Canny filter based thresholding generated 3D models with a significantly higher accuracy compared to those generated through visually selected thresholds. This study demonstrates that 3D models with sub-voxel accuracy can be generated utilising relatively simple segmentation methods that are available to the general research community.


Journal of Orthopaedic Trauma | 2008

Fit assessment of anatomic plates for the distal medial tibia.

Beat Schmutz; Martin E. Wullschleger; Henry Kim; Hansrudi Noser; Michael Schütz

Objectives: With the development and popularization of minimally invasive surgical methods and implants for fracture fixation, it is increasingly important that the available implants are precontoured to the specific anatomic location for which they are designed. The objective of this study was to develop a noninvasive method and criteria for quantifying the fit of a distal periarticular medial tibia plate and to test the method on a small set of tibia models. Methods: The undersurface of the plate was extracted from a digital model of the plate. The surface of the plate was fitted to 21 computer tomography (CT)-based 3-dimensional (3-D) models of human tibiae. Four criteria were defined that constitute an anatomic plate fit and subsequently were applied for the quantitative fit assessment. The fitting of the plate undersurface to the bone was entirely conducted in a virtual environment. Results: An anatomic fit of the plate was achieved for 4 of the models (19%). The individual categories generated fits of 62% (n = 13) for the proximal end; 43% (n = 9) for the proximal angle; 57% (n = 12) for the middle distance; and 57% (n = 12) for a distal fit. Conclusions: Although for the 4 individual criteria plate fits of 43%-62% were achieved, a global/anatomic fit only occurred for 19% of the bone models. This outcome is likely a result of bone morphology variations, which exist in a random population sample combined with the effects of a nonoptimized plate shape. Recommendations for optimizing the fit of the plate are discussed.


Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine | 2010

Computational investigations of mechanical failures of internal plate fixation.

Gongfa Chen; Beat Schmutz; Martin E. Wullschleger; Mark J. Pearcy; Michael Schuetz

Abstract This paper investigated the biomechanics of two clinical cases of bone fracture treatments. Both fractures were treated with the same locking compression plate but with different numbers of screws as well as different plate materials. The fracture treated with 12 screws (rigid fixation) failed at 7 weeks with the plate breaking; the fracture with six screws (flexible fixation) endured the entire healing process. It was hypothesized that the plate failure in the unsuccessful case was due to the material fatigue induced by stress concentration in the plate. As the two clinical cases had different fracture locations and different plate materials, finite element simulations were undertaken for each fractured bone fixed by both a rigid and a flexible method. This enabled comparisons to be made between the rigid and flexible fixation methods. The fatigue life was assessed for each fixation method. The results showed that the stress in the rigid fixation methods could be significantly higher than that in flexible fixation methods. The fatigue analyses showed that, with the stress level in flexible fixation (i.e. with fewer screws), the plate was able to endure 2000 days, and that the plate in rigid fixation could fail by fatigue fracture in 20 days. The paper concludes that the rigid fixation method resulted in serious stress concentrations in the plate, which induced fatigue failure. The flexible fixation gave sufficient stability and was better for fracture healing.


Computer Methods in Biomechanics and Biomedical Engineering | 2011

Fit optimisation of a distal medial tibia plate

Beat Schmutz; Martin E. Wullschleger; Hansrudi Noser; Mark D. Barry; John Meek; Michael Schütz

An iterative method for the fit optimisation of a pre-contoured fracture fixation plate for a given bone data set is presented. Both plate shape optimisation and plate fit quantification are conducted in a virtual environment utilising computer graphical methods and 3D bone and plate models. Two optimised shapes of the undersurface of an existing distal medial tibia plate were generated based on a dataset of 45 3D bone models reconstructed from computed tomography image data of Japanese tibiae. The existing plate shape achieved an anatomical fit on 13% of tibiae from the dataset. Modified plate 1 achieved an anatomical fit for 42% and modified plate 2 a fit for 67% of the bones. If either modified plate 1 or plate 2 is used, then the anatomical fit can be increased to 82% for the same dataset. Issues pertaining to any further improvement in plate fit/shape are discussed.


Computer Methods in Biomechanics and Biomedical Engineering | 2006

Development and validation of a generic 3D model of the distal femur

Beat Schmutz; Karen J. Reynolds; John P. Slavotinek

The development and validation of a virtual generic 3D model of the distal femur using computer graphical methods is presented. The synthesis of the generic model requires the following steps: acquisition of bony 3D morphology using standard computed tomography (CT) imaging; alignment of 3D models reconstructed from CT images with a common coordinate system; computer graphical sectioning of the models; extraction of bone contours from the image sections; combining and averaging of extracted contours; and 3D reconstruction of the averaged contours. The generic models reconstructed from the averaged contours of six cadaver femora were validated by comparing their surface geometry on a point to point basis with that of the CT reconstructed reference models. The mean errors ranged from 0.99 to 2.5 mm and were in agreement with the qualitative assessment of the models.


Quantitative imaging in medicine and surgery | 2014

Metal artifacts from titanium and steel screws in CT, 1.5T and 3T MR images of the tibial Pilon: a quantitative assessment in 3D.

Shairah Radzi; Gary Cowin; Mark Robinson; Jit Pratap; Andrew Volp; Michael Schuetz; Beat Schmutz

Radiographs are commonly used to assess articular reduction of the distal tibia (pilon) fractures postoperatively, but may reveal malreductions inaccurately. While magnetic resonance imaging (MRI) and computed tomography (CT) are potential three-dimensional (3D) alternatives they generate metal-related artifacts. This study aims to quantify the artifact size from orthopaedic screws using CT, 1.5T and 3T MRI data. Three screws were inserted into one intact human cadaver ankle specimen proximal to and along the distal articular surface, then CT, 1.5T and 3T MRI scanned. Four types of screws were investigated: titanium alloy (TA), stainless steel (SS) (Ø =3.5 mm), cannulated TA (CTA) and cannulated SS (CSS) (Ø =4.0 mm, Ø empty core =2.6 mm). 3D artifact models were reconstructed using adaptive thresholding. The artifact size was measured by calculating the perpendicular distance from the central screw axis to the boundary of the artifact in four anatomical directions with respect to the distal tibia. The artifact sizes (in the order of TA, SS, CTA and CSS) from CT were 2.0, 2.6, 1.6 and 2.0 mm; from 1.5T MRI they were 3.7, 10.9, 2.9, and 9 mm; and 3T MRI they were 4.4, 15.3, 3.8, and 11.6 mm respectively. Therefore, CT can be used as long as the screws are at a safe distance of about 2 mm from the articular surface. MRI can be used if the screws are at least 3 mm away from the articular surface except for SS and CSS. Artifacts from steel screws were too large thus obstructed the pilon from being visualised in MRI. Significant differences (P<0.05) were found in the size of artifacts between all imaging modalities, screw types and material types, except 1.5T versus 3T MRI for the SS screws (P=0.063). CTA screws near the joint surface can improve postoperative assessment in CT and MRI. MRI presents a favourable non-ionising alternative when using titanium hardware. Since these factors may influence the quality of postoperative assessment, potential improvements in operative techniques should be considered.


Journal of Medical Engineering & Technology | 2008

Customization of a generic 3D model of the distal femur using diagnostic radiographs

Beat Schmutz; Karen J. Reynolds; John P. Slavotinek

A method for the customization of a generic 3D model of the distal femur is presented. The customization method involves two steps: acquisition of calibrated orthogonal planar radiographs; and linear scaling of the generic model based on the width of a subjects femoral condyles as measured on the planar radiographs. Planar radiographs of seven intact lower cadaver limbs were obtained. The customized generic models were validated by comparing their surface geometry with that of CT-reconstructed reference models. The overall mean error was 1.2 mm. The results demonstrate that uniform scaling as a first step in the customization process produced a base model of accuracy comparable to other models reported in the literature.


Journal of Biomechanics | 2008

USING MRI FOR THE IMAGING OF LONG BONES: FIRST EXPERIENCES

Beat Schmutz; Andrew Volp; Konstantin I. Momot; Mark J. Pearcy; Michael Schuetz

Many applications in medical research and development require virtual three dimensional (3D) models of bones. The current gold standard for the acquisition of such data is Computer Tomography (CT) scanning. Due to the amount of radiation involved, CT scanning is generally limited to the imaging of clinical cases and cadaver specimens [Messmer, 2007]. Magnetic Resonance Imaging (MRI) is not routinely used for the imaging of bones because of difficulties in precise segmentation between bone and certain soft tissue types as well as higher costs compared to CT. As MRI does not involve ionising radiation it is ideally suited for the imaging of volunteers, who can be recruited according to study specific requirements. This study aimed to develop a MRI scanning protocol suitable to image the legs of volunteers and to provide an initial validation of the geometrical accuracy of the reconstructed 3D models.


Medical Engineering & Physics | 2014

Assessing the bilateral geometrical differences of the tibia--are they the same?

Shairah Radzi; M. Uesugi; A. Baird; S. Mishra; Michael Schuetz; Beat Schmutz

Contralateral bones are often used in many medical applications but it is assumed that their bilateral differences are insignificant. Previous studies used a limited number of distance measurements in quantifying the corresponding differences; therefore, little is known about their bilateral 3D surface asymmetries. The aim of the study is to develop a comprehensive method to quantify geometrical asymmetries between the left and right tibia in order to provide first results on whether the contralateral tibia can be used as an equivalent reference. In this study, 3D bone models were reconstructed from CT scans of seven tibiae pairs, and 34 variables consisting of 2D and 3D measurements were measured from various anatomical regions. All 2D measurements, and lateral plateau and distal subchondral bone surface measurements showed insignificant differences (p>0.05), but the rest of the surfaces showed significant differences (p<0.05). Our results suggest that the contralateral tibia can be used as a reference especially in surgical applications such as articular reconstructions since the bilateral differences in the subchondral bone surfaces were less than 0.3mm. The method can also be potentially transferable to other relevant studies that require the accurate quantification of bone bilateral asymmetries.


GSTF Journal of Engineering Technology | 2012

Orthopedic bone plates: Evolution in Structure, Implementation technique and biomaterial

Javad Malekani; Beat Schmutz; YuanTong Gu; Michael Schuetz; Prasad K. Yarlagadda

With many important developments over the last century, nowadays orthopedic bone plate now excels over other types of internal fixators in bone fracture fixation. The developments involve the design, material and implementation techniques of the plates. This paper aims to review the evolution in implementation technique and biomaterial of the orthopedic bone plates. Plates were initially used to fix the underlying bones firmly. Accordingly, Compression plate (CP), Dynamic compression plate (DCP), Limited contact dynamic compression plate (LC-DCP) and Point contact fixator (PC-Fix) were developed. Later, the implementation approach was changed to locking, and the Less Invasive Stabilization System (LISS) plate was introduced as a result. Finally, a combination of both of these approaches has been used by introducing the Locking Compression Plate (LCP). Currently, precontoured LCPs are mainly used for bone fracture fixation. In parallel with structure and implementation techniques, numerous advances have occurred in biomaterials of the plates. Titanium and stainless steel alloys are now the most common biomaterials in production of orthopedic bone plates. However, regarding the biocompatibility, bioactivity and biodegradability characteristics of Mg alloys, Ta alloys, SMAs, carbon fiber composites and bioceramics, these materials are considered as potentially suitable for plates. However, due to poor mechanical properties, they have very limited applications. Therefore, further studies are required in future to solve these problems and make them feasible for heavy-duty bone plates.

Collaboration


Dive into the Beat Schmutz's collaboration.

Top Co-Authors

Avatar

Michael Schuetz

Queensland University of Technology

View shared research outputs
Top Co-Authors

Avatar

Prasad K. Yarlagadda

Queensland University of Technology

View shared research outputs
Top Co-Authors

Avatar

Martin E. Wullschleger

Queensland University of Technology

View shared research outputs
Top Co-Authors

Avatar

Javad Malekani

Queensland University of Technology

View shared research outputs
Top Co-Authors

Avatar

Gongfa Chen

Queensland University of Technology

View shared research outputs
Top Co-Authors

Avatar

Kanchana Rathnayaka

Queensland University of Technology

View shared research outputs
Top Co-Authors

Avatar

Mark J. Pearcy

Queensland University of Technology

View shared research outputs
Top Co-Authors

Avatar

YuanTong Gu

Queensland University of Technology

View shared research outputs
Top Co-Authors

Avatar

Andrew Volp

Princess Alexandra Hospital

View shared research outputs
Top Co-Authors

Avatar

Hazreen Harith

Queensland University of Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge