Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Behzad Aliahmad is active.

Publication


Featured researches published by Behzad Aliahmad.


Investigative Ophthalmology & Visual Science | 2012

Does Retinal Vascular Geometry Vary with Cardiac Cycle

Hao Hao; Muhammad Bayu Sasongko; Tien Yin Wong; Mohd Zulfaezal Che Azemin; Behzad Aliahmad; Lauren Hodgson; Ryo Kawasaki; Carol Y. Cheung; Jie Jin Wang; Dinesh Kumar

PURPOSE Changes in retinal vascular parameters have been shown to be associated with systemic vascular diseases. In this study, we assessed the physiologic variations in retinal vascular measurements during the cardiac cycle. METHODS Fundus images were taken using electrocardiogram-synchronized retinal camera at nine distinct cardiac points from 15 healthy volunteers (135 images). Analyses of retinal vessel geometric measures, including retinal vessel caliber (individual and summary), tortuosity, branching angle, length-diameter ratio (LDR), and optimality deviation, were performed using semiautomated computer software. Repeated-measures ANOVAs were used to obtain the means and to estimate the variation of each cardiac point compared with cardiac point 1. RESULTS There was a significant variation of the caliber of the individual arteriolar and venular vessels. However, there was no significant variation found for vessel caliber summary, represented by the central retinal arteriolar equivalent (CRAE) and the central retinal venular equivalent (CRVE). There was also no significant variation found for tortuosity and branching angle, and LDR showed none or very little variations at different cardiac points: variations in caliber ranges between 0 and 4.1%, tortuosity 0 and 1.5%, branching angle 0 and 3.5%, and LDR 0 and 2%; all values for variations, P > 0.1; linear trend, P > 0.5; and nonlinear trend, P > 0.8. CONCLUSIONS This study showed that there were minimal variations in the CRAE, CRVE, tortuosity, and branching angle that are clinically used for two-dimensional measures of retinal vascular geometry during cardiac cycles. However, there was significant variation in the caliber of the individual vessels over the cardiac cycle.


The Scientific World Journal | 2014

Zone Specific Fractal Dimension of Retinal Images as Predictor of Stroke Incidence

Behzad Aliahmad; Dinesh Kumar; Hao Hao; Premith Unnikrishnan; Mohd Zulfaezal Che Azemin; Ryo Kawasaki; Paul Mitchell

Fractal dimensions (FDs) are frequently used for summarizing the complexity of retinal vascular. However, previous techniques on this topic were not zone specific. A new methodology to measure FD of a specific zone in retinal images has been developed and tested as a marker for stroke prediction. Higuchis fractal dimension was measured in circumferential direction (FDC) with respect to optic disk (OD), in three concentric regions between OD boundary and 1.5 OD diameter from its margin. The significance of its association with future episode of stroke event was tested using the Blue Mountain Eye Study (BMES) database and compared against spectrum fractal dimension (SFD) and box-counting (BC) dimension. Kruskal-Wallis analysis revealed FDC as a better predictor of stroke (H = 5.80, P = 0.016, α = 0.05) compared with SFD (H = 0.51, P = 0.475, α = 0.05) and BC (H = 0.41, P = 0.520, α = 0.05) with overall lower median value for the cases compared to the control group. This work has shown that there is a significant association between zone specific FDC of eye fundus images with future episode of stroke while this difference is not significant when other FD methods are employed.


International Scholarly Research Notices | 2013

A method for visualization of fine retinal vascular pulsation using nonmydriatic fundus camera synchronized with electrocardiogram.

Dinesh Kumar; Behzad Aliahmad; Hao Hao; Mohd Zulfaezal Che Azemin; Ryo Kawasaki

Pulsatile changes in retinal vascular geometry over the cardiac cycle have clinical implication for diagnosis of ocular and systemic vascular diseases. In this study, we report a Vesselness Mapping of Retinal Image Sequence (VMRS) methodology to visualize the vessel pulsation and quantify the pulsatile motions in the cardiac cycle. Retinal images were recorded in an image sequence corresponding to 8 segments of the cardiac cycle using a nonmydriatic fundus camera (Canon CR45, Canon Inc., Japan) modified with ECG-synchronization. Individual cross-sectional vessel diameters were measured separately and the significance of the variations was tested statistically by repeated measures analysis of variance (ANOVA). The graders observed an improved quality of vessel pulsation on a wide region around the optic disk using the VMRS. Individual cross- sectional vessel diameter measurement after visualization of pulsatile motions resulted in the detection of more significant diameter change for both arterioles (3.3 μm, P = 0.001) and venules (6.6 μm, P < 0.001) compared to individual measurement without visualization of the pulsatile motions (all P values > 0.05), showing an increase of 2.1 μm and 4.7 μm for arterioles and venules, respectively.


International Scholarly Research Notices | 2012

Retinal Vessel Diameter Measurement Using Unsupervised Linear Discriminant Analysis

Dinesh Kumar; Behzad Aliahmad; Hao Hao

An automatic vessel diameter measurement technique based on linear discriminant analysis (LDA) has been proposed. After estimating the vessel wall, the vessel cross-section profile is divided into three regions: two corresponding to the background and one to the vessel. The algorithm was tested on more than 5000 cross-sections of retinal vessels from the REVIEW dataset through comparative study with the state-of-the-art techniques. Cross-correlation analyses were performed to determine the degree to which the proposed technique was close to the ground truth. The results indicate that proposed algorithm consistently performed better than most of other techniques and was highly correlated with the manual measurement as the reference diameter. The proposed method does not require any supervision and is suitable for automatic analysis.


issnip biosignals and biorobotics conference biosignals and robotics for better and safer living | 2012

Retinal vessel diameter measurement using multi-step regression method

Behzad Aliahmad; Dinesh Kumar; Samira Janghorban; Mohd Zulfaezal Che Azemin; Hao Hao; Ryo Kawasaki

Study of retinal blood vessel features, especially the caliber, has been widely used for risk level assessment of certain disease conditions. In this work a vessel diameter measurement technique based on Gaussian modeling has been proposed. This method adaptively combines a series of second and higher order Gaussians to model the vessel profile and uses the sigma parameter of the best fitted Generalized Gaussians to the boundaries, to measure the vessel caliber. One advantage of this technique is that, unlike other methods, it does not assume the vessel profile as a symmetrical Gaussian-like shape with similar blurriness levels at the edges. The technique has been tested on 580 cross-sections from normal and pathological public datasets with mixed quality fundus images. Comparison was made against two gold standard techniques and a ground truth obtained manually by three experts to sub-pixel accuracy.


international conference of the ieee engineering in medicine and biology society | 2011

Automatic retinal vessel profiling using multi-step regression method

Behzad Aliahmad; Dinesh Kumar; Samira Janghorban; Mohd Zulfaezal Che Azemin; Hao Hao; Ryo Kawasaki

Caliber of the retinal blood vessel is widely used for risk assessment of cardiovascular diseases. Accurate and automatic caliber measurement requires a precise model to be made for the vessel profile. In this paper, we present a new approach for retinal vessel profiling in which the background noise, uneven illuminations and specular reflections have all been considered. In this method, regression analysis is performed with a series of second-order Gaussians to filter and up-sample the original vessel profile. This is then segmented to identify and represent the vessel edges by two Generalized Gaussian functions. The technique has been applied to retinal images and the results have been verified and compared with the state of the art automatic techniques.


ieee international conference on computer applications and industrial electronics | 2011

Improved retinal photography method and visualization of multiple retinal images

Hao Hao; Dinesh Kumar; Behzad Aliahmad; Mohd Zulfaezal Che Azemin

The current instantaneous retinal photography method has large variations in the retinal vessel diameter measurement due to retinal vessel pulsation which has been reported associated to the cardiac cycle. The previous limited studies show limitation on their methodologies. To better understand and analyze the variation in the cardiac cycle, we developed an Electrocardiogram (ECG) synchronized retinal photography method which overcomes the previous limitations. Our method is able to detect ECG signal and calculate R-R interval in real time. The retinal camera can be triggered electronically and automatically at the designated time delays based on the real-time calculated R-R interval. Our results demonstrate this method is able to provide the visualization of the retinal vessel pulsations. It will be helpful for studying the relation of ophthalmology and cardiology. It also provides a possible solution to eliminate the cardiac cycle related photography variation in the retinal images analysis.


issnip biosignals and biorobotics conference biosignals and robotics for better and safer living | 2013

Using color histogram as the trait of retina biometric

Hao Hao; Dinesh Kumar; Behzad Aliahmad; Mohd Zulfaezal Che Azemin; Ryo Kawasaki

Retina biometric has applications on high security access control systems. The interference of lighting and deformation of viewpoint in the retina image acquisition have impact on the process of retina feature extraction and matching. In this paper, we propose a method using color histogram as the trait of retina biometric. The color histogram has shown the feature of deformation invariant. The enhancement using discrete wavelet transform decomposition minimizes the difference within the individuals and increases the correlation between the retinal images of the same person. This method provides a solution against the variation within the individuals and lower false rejection rate in the retina biometric.


ieee-embs conference on biomedical engineering and sciences | 2012

Loss of calibre information during vessel segmentation

Mohd Zulfaezal Che Azemin; Dinesh Kumar; Behzad Aliahmad; Hao Hao

To obtain precise calibre measurements, there are two general approaches: segment the vessels and measure the diameter, and to measure the diameter from the greyscale images. While there is a claim that vessel segmentation does not solve diameter measurement problems it has not been proven experimentally. The aim of this work is two-fold: first, to prove that the resulting edges from good vessel segmentation may not be suitable for precise diameter measurement, and, second, to propose a method for compensating for the imprecision in the calibre measurement from the segmentation.


The International Journal of Lower Extremity Wounds | 2018

High-Resolution Spectral Analysis Accurately Identifies the Bacterial Signature in Infected Chronic Foot Ulcers in People With Diabetes.

Sridhar Poosapadi Arjunan; Aye Nyein Tint; Behzad Aliahmad; Dinesh Kumar; Ravi Shukla; Julie Miller; Jeffrey D. Zajac; Gayathiri Wang; Rekha Viswanathan; Elif I. Ekinci

Diabetic foot infections are a major cause of hospitalization, and delayed treatment can lead to numerous complications. The aim of this research was to investigate high-resolution spectroscopy of the wound center and periwound area for real-time estimation of multispectral signature of bacteria at the base of diabetic foot ulcers. We investigated the spectrum of the reflected visual light from diabetic foot ulcers and developed a method that identifies the presence of bacteria in the wound infections. We undertook a prospective pilot study on 18 patients with type 1 and type 2 diabetes and chronic diabetic foot ulcers. The spectral coefficients were directly compared with the results from the wound swab. The results of the multispectral analysis demonstrated 100% sensitivity, with 100% negative predictive values of identifying the presence of the bacteria, which was the cause of the infection in the wound. The results of our study suggest that the changes in the multispectral properties of the wound can be used to identify the presence of bacteria in the infected area using a noninvasive device without any contact with the wound. This technique holds great promise for real-time objective evaluation of the wound infection status beyond the standard visual assessment of diabetic foot ulcers.

Collaboration


Dive into the Behzad Aliahmad's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Mohd Zulfaezal Che Azemin

International Islamic University Malaysia

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Marc Sarossy

University of Melbourne

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Kaarin J. Anstey

Australian National University

View shared research outputs
Top Co-Authors

Avatar

Kim M. Kiely

Australian National University

View shared research outputs
Researchain Logo
Decentralizing Knowledge