Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Bei-Jian Huang is active.

Publication


Featured researches published by Bei-Jian Huang.


Journal of Ultrasound in Medicine | 2005

Imaging of Focal Liver Lesions Low-Mechanical-Index Real-time Ultrasonography With SonoVue

Hong Ding; Wen-Ping Wang; Bei-Jian Huang; Rui-Xue Wei; N.A. He; Qing Qi; Chaolun Li

The purpose of this study was to evaluate the usefulness of a contrast‐enhanced contrast‐specific ultrasonographic technique with a low mechanical index for characterization of focal liver lesions.


Antimicrobial Agents and Chemotherapy | 2011

Enhancement of Vancomycin Activity against Biofilms by Using Ultrasound-Targeted Microbubble Destruction

N.A. He; Jian Hu; Huayong Liu; Tao Zhu; Bei-Jian Huang; Xueqin Wang; Yang Wu; Wen-Ping Wang; Di Qu

ABSTRACT Treating biofilm infections on implanted medical devices is formidable, even with extensive antibiotic therapy. The aim of this study was to investigate whether ultrasound (US)-targeted microbubble (MB) destruction (UTMD) could enhance vancomycin activity against Staphylococcus epidermidis RP62A biofilms. Twelve-hour biofilms were treated with vancomycin combined with UTMD. The vancomycin and MB (SonoVue) were used at concentrations of 100 μg/ml and 30% (vol/vol), respectively, in studies in vitro. After US exposure (0.08 MHz, 1.0 W/cm2, 50% duty cycle, and 10-min duration), the biofilms were cultured at 37°C for another 12 h. The results showed that many micropores were found in biofilms treated with vancomycin combined with UTMD. Biofilm densities (A570 values) and the viable counts of S. epidermidis recovered from the biofilm were significantly decreased compared with those of any other groups. Furthermore, the highest percentage of dead cells was found, using confocal laser scanning microscopy, in the biofilm treated with vancomycin combined with UTMD. The viable counts of bacteria in biofilms in an in vivo rabbit model also confirmed the enhanced effect of vancomycin combined with UTMD. UTMD may have great potential for improving antibiotic activity against biofilm infections.


Academic Radiology | 2010

Microwave Ablation: An Experimental Comparative Study on Internally Cooled Antenna versus Non-internally Cooled Antenna in Liver Models

N.A. He; Wen-Ping Wang; Zhengbiao Ji; Chaolun Li; Bei-Jian Huang

RATIONAL AND OBJECTIVES Microwave ablation is an alternative therapy with high cost-effectiveness for liver malignancy. The authors designed this experiment to compare the effect of microwave ablation using a non-internally cooled (NIC) antenna with that using an internally cooled (IC) antenna in both an ex vivo and an in vivo liver models. MATERIALS AND METHODS Sixty-two microwave ablations were performed in ex vivo porcine and in vivo canine liver models (NIC antenna, 28 coagulations; IC antenna, 34 coagulations). Pair comparisons were executed in terms of the coagulation parameters, including short-axis diameter (SD), long-axis diameter (LD), and spherical ratio (SR, SD/LD). The distributions of tissue temperatures were compared in ex vivo ablation. During in vivo ablation, the temperatures of antenna shaft were measured and unintended tissue coagulation were observed and compared. RESULTS In both ex vivo and in vivo ablations, less charring areas were found around the IC antenna shaft. With a longer SD (P < .01) and a shorter LD (P < .01), the coagulations of IC antenna appeared to be more spherical than those of NIC antenna (P < .01). During ablations in vivo, the temperatures of NIC antennas shaft were up to 90 degrees C or even higher, which resulted in some unintended tissue coagulation, whereas the temperatures of IC antennas shaft were lower than 20 degrees C in all ablation processes without any unintended tissue coagulation (P < .01). CONCLUSION The IC antenna performed better than NIC antenna in microwave ablation for liver models and might be more suitable for therapy for liver malignancy in clinical practice.


Journal of Gastroenterology and Hepatology | 2014

Value of wash‐in and wash‐out time in the diagnosis between hepatocellular carcinoma and other hepatic nodules with similar vascular pattern on contrast‐enhanced ultrasound

Wen-Tao Kong; Wen-Ping Wang; Bei-Jian Huang; Hong Ding; Feng Mao

The study aims to demonstrate whether the wash‐in and wash‐out time can be reliable as a criterion in the differential diagnosis between hepatocellular carcinoma (HCC) and other hepatic nodules with vascular pattern similar to HCC on contrast‐enhanced ultrasound (CEUS).


Ultrasound in Medicine and Biology | 2014

Quantification of Carotid Plaque Neovascularization Using Contrast-Enhanced Ultrasound With Histopathologic Validation

Chaolun Li; Wanyuan He; Daqiao Guo; Lingli Chen; Xuejuan Jin; Weiping Wang; Bei-Jian Huang; Wen-Ping Wang

We sought to evaluate contrast-enhanced ultrasound (CEUS) imaging for the quantification of carotid plaque neovascularization. Seventeen patients underwent carotid endarterectomy after standard ultrasound and CEUS. Semiquantitative and quantitative analyses of contrast enhancement within the plaque were performed using a visual interpretation scale and quantitative analysis software, respectively. Enhancement intensity (dB) was measured at the plaque (EI(plaque)). Each specimen was stained with CD34 and CD68 to assess for microvessels and macrophages, respectively. Semiquantitative CEUS analyses were correlated with neovascularization at histology (r = 0.70, p = 0.002). Quantitative analysis was also correlated with neovascularization at histology (EI(plaque)r = 0.81, p < 0.001). EI(plaque) (r = 0.64, p = 0.01) was correlated with the degree of enhancement as assessed visually. Semiquantitative and quantitative analyses were not correlated with macrophage infiltration at the plaque. Contrast enhancement in the carotid plaque was correlated with neovascularity at the histopathologic exam. Furthermore, semiquantitative and quantitative measurements were highly correlated with each other, suggesting that either can be used to detect intraplaque neovascularization.


Abdominal Imaging | 2014

Contrast-enhanced ultrasonography for evaluation of cystic renal mass: in comparison to contrast-enhanced CT and conventional ultrasound

Li-Yun Xue; Qing Lu; Bei-Jian Huang; Jiao-jiao Ma; Li-Xia Yan; Jie-Xian Wen; Wen-Ping Wang

AbsractPurposeTo assess the value of contrast-enhanced ultrasonography (CEUS) in evaluating cystic renal lesions compared with conventional ultrasound (US) and contrast-enhanced computed tomography (CECT).MethodsOne hundred and three patients with complex cystic renal masses underwent preoperative US and CEUS, among which 70 conducted CECT at our institution. The images were analyzed with the number of septa, septa and wall thickness and the presence of solid component, and final diagnosis was made.ResultsIn malignancies, CEUS demonstrated more septa, thicker wall or septa, and more solid components than US and CECT. CEUS permitted categorization of 51.7% (30/58) and 28.6% (10/35) of malignant tumors in higher grade than by US and CECT, respectively. In benign lesions, CEUS detected more septa than CECT and correctly diagnosed benign cysts which appeared as solid lesions in US. CEUS permitted downgrading of 71.1% (32/45) and 17.1% (6/35) of benign lesions compared to US and CECT. The diagnostic performance of CEUS was better than US for benign cystic lesions. The phenomenon that solid-like component by US did not enhance by CEUS was a strong predictor of benign disease, with a positive predictive value (PPV) of 100%. Enhancement of solid, soft tissue by CEUS was highly predictive of malignancy, with a PPV of 100%.ConclusionsCEUS was superior to US and CECT in visualizing the number of septa septa and wall thickness, and the presence of solid component of cystic renal lesions. CEUS may play a similar role to CECT in the diagnosis of renal cystic lesions, and better than US.


European Journal of Radiology | 2013

Evaluation of renal urothelial carcinoma by contrast-enhanced ultrasonography.

Li-Yun Xue; Qing Lu; Bei-Jian Huang; Chaolun Li; Cui-Ju Yan; Jie-Xian Wen; Wen-Ping Wang

PURPOSE To observe ultrasonographic features of urothelial carcinoma in renal pelvis and evaluate contrast-enhanced ultrasound (CEUS) in diagnosis. MATERIALS AND METHODS Fifty-two patients with urothelial carcinoma underwent preoperative conventional US, colour Doppler flow imaging (CDFI) and CEUS. RESULTS Of 52 total lesions, 41 (78.8%) could be clearly identified by US, and 49 (94.2%) were enhanced by CEUS. Among US-imaged lesions, 39 (95.1%) were solid tumours, and two (4.9%) were mixed solid-cystic; 25 (61.0%) were isoechoic, 11 (26.8%) hypoechoic, and five (12.2%) hyperechoic. Analysis of tumour blood flow by CDFI characterised 17 avascular lesions (41.5% of total), 16 hypovascular (39.0%), and 8 hypervascular (19.5%). The resistance index ranged from 0.65 to 0.88 (mean of 0.71). Enhancement was seen in 49 lesions after injection of SonoVue. A slow enhancement pattern was observed in 36 lesions (73.5%) relative to renal cortex, and 13/49 (26.5%) showed simultaneous enhancement. At peak enhancement, 38 lesions (77.6%) were hypo-enhanced, six (12.2%) iso-enhanced, and five (10.2%) hyper-enhanced. There were 12 lesions with intertumoural necrosis or haemorrhage (24.5%) that were heterogeneously enhanced, and 37 (75.5%) were homogeneously enhanced. A fast washout pattern was observed in 46 lesions (93.9%), synchronous washout in two (4.08%), and slow washout in one (2.04%). CONCLUSIONS Slow-in, fast-out, and hypo-enhancement properties are associated with renal urothelial carcinoma and may thus have diagnostic value. We found that CEUS is able to identify tumours that are ambiguous by conventional US, and it thus significantly improves the confidence of diagnosis.


European Journal of Radiology | 2015

Comparison of retraction phenomenon and BI-RADS-US descriptors in differentiating benign and malignant breast masses using an automated breast volume scanner.

Feng-Yang Zheng; Li-Xia Yan; Bei-Jian Huang; Han-Sheng Xia; Xi Wang; Qing Lu; Cui-xian Li; Wen-Ping Wang

OBJECTIVE To compare the diagnostic values of retraction phenomenon in the coronal planes and descriptors in the Breast Imaging Reporting and Data System-Ultrasound (BI-RADS-US) lexicon in differentiating benign and malignant breast masses using an automated breast volume scanner (ABVS). MATERIALS AND METHODS Two hundred and eight female patients with 237 pathologically proven breast masses (120 benign and 117 malignant) were included in this study. ABVS was performed for each mass after preoperative localization by conventional ultrasonography (US). Multivariate logistic regression analysis was performed to assess independent variables for malignancy prediction. Diagnostic performance was evaluated through the receiver operating characteristic (ROC) curve analysis. RESULTS Retraction phenomenon (odds ratio [OR]: 76.70; 95% confidence interval [CI]: 12.55, 468.70; P<0.001) was the strongest independent predictor for malignant masses, followed by microlobulated margins (OR: 55.87; 95% CI: 12.56, 248.44; P<0.001), angular margins (OR: 36.44; 95% CI: 4.55, 292.06; P=0.001), calcifications (OR: 5.53; 95% CI: 1.34, 22.88; P=0.018,) and patient age (OR: 1.10; 95% CI: 1.03, 1.17; P=0.004). Mass shape, orientation, echo pattern, indistinct margins, spiculated margins, and mass size were not significantly associated with breast malignancy. Area under the ROC curve (Az) for microlobulated margins and retraction phenomenon was higher than that for other significant independent predictors. Az, sensitivity, and specificity were 0.877 (95% CI: 0.829, 0.926) and 0.838 (95% CI: 0.783, 0.892), 82.9% and 70.1%, and 92.5% and 98.3%, respectively, for microlobulated margins and retraction phenomenon. CONCLUSIONS Retraction phenomenon and microlobulated margins have high diagnostic values in the differentiation of benign and malignant breast masses using an ABVS.


Journal of Clinical Ultrasound | 2011

Value of contrast-enhanced sonography in the diagnosis of peripheral intrahepatic cholangiocarcinoma.

Chaolun Li; Wen-Ping Wang; Hong Ding; Bei-Jian Huang; Jiaying Cao; Feng Mao; Zhengbiao Ji

To illustrate contrast‐enhanced harmonic ultrasonography (CEUS) findings of peripheral intrahepatic cholangiocarcinoma (PICC) and to assess the usefulness of CEUS in the diagnosis of this disease.


Clinical Radiology | 2014

Radiofrequency ablation guided by contrast-enhanced ultrasound for hepatic malignancies: Preliminary results

Yi Dong; Wen-Ping Wang; Y.-H. Gan; Bei-Jian Huang; Hong Ding

AIM To evaluate whether contrast-enhanced ultrasound (CEUS)-guided radiofrequency ablation (RFA) can be performed effectively in small hepatic malignancies that are invisible or poorly visualized at traditional grey-scale ultrasonography (US). MATERIALS AND METHODS The institutional ethics committee approved the study, and all patients provided written informed consent before their enrolment. The study focused on 55 patients (43 men, 12 women, age 57.4 ± 10.9 years) with 60 hepatic lesions from May 2010 to March 2011. All lesions were treated with multipolar radiofrequency ablation (RFA). During the RFA procedure, with the injection of ultrasound contrast agent (sulphur hexafluoride; SonoVue, Bracco Imaging Spa, Milan, Italy), RFA was conducted under CEUS guidance when the optimal depiction of a lesion was obtained. Artificial pleural effusions were used in those cases obstructed by the lungs. Twenty-four hours after RFA, contrast-enhanced MRI was used as the reference standard to evaluate the primary effectiveness rate and complete tumour necrosis. The follow-up time was 12-24 months (median 15 months). RESULTS Among 60 hepatic malignancies, CEUS detected 57 lesions (95%), which was higher than that at US (26.6%). Artificial pleural effusions were performed in three cases, resulting in the detection of three additional lesions. The insertion of RFA electrodes was monitored by CEUS in all lesions. Immediately after RFA, complete tumour necrosis were achieved in all 60 lesions as apparent at MRI, for a primary effectiveness rate of 100%. CONCLUSION CEUS-guided RFA is a promising technique for targeting and improving the efficiency of treatment of hepatic malignancies.

Collaboration


Dive into the Bei-Jian Huang's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge