Ben van Ravenzwaay
Bosch
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Ben van Ravenzwaay.
Toxicology Letters | 2009
Ben van Ravenzwaay; Robert Landsiedel; Eric Fabian; Silke Burkhardt; Volker Strauss; Lan Ma-Hock
The fate of nano-TiO(2) particles in the body was investigated after inhalation exposure or intravenous (i.v.) injection, and compared with pigmentary TiO(2) and quartz. For this purpose, a 5-day inhalation study (6h/day, head/nose exposure) was carried out in male Wistar rats using nano-TiO(2) (100mg/m(3)), pigmentary TiO(2) (250mg/m(3)) and quartz dust DQ 12 (100mg/m(3)). Deposition in the lung and tissue distribution was evaluated, and histological examination of the respiratory tract was performed upon termination of exposure, and 2 weeks after the last exposure. Broncho-alveolar lavage (BAL) was carried out 3 and 14 days after the last exposure. Rats were also injected with a single intravenous dose of a suspension of TiO(2) in serum (5mg/kg body weight), and tissue content of TiO(2) was determined 1, 14 and 28 days later. The majority of the inhaled nano-TiO(2) was deposited in the lung. Translocation to the mediastinal lymph nodes was also noted, although to smaller amounts than following inhalation of pigmentary TiO(2), but much higher amounts than after exposure to quartz. Systemically available nano-TiO(2), as simulated by the i.v. injection, was trapped mainly in the liver and spleen. The (agglomerate) particle size of lung deposited nano-TiO(2) was virtually the same as in the test atmosphere. Changes in BAL fluid composition and histological examination indicated mild neutrophilic inflammation and activation of macrophages in the lung. The effects were reversible for nano- and pigmentary TiO(2), but progressive for quartz. The effects observed after 5-day inhalation exposure to nano-TiO(2) were qualitatively similar to those reported in sub-chronic studies.
Archives of Toxicology | 2012
Christoph L. Klein; Karin Wiench; Martin Wiemann; Lan Ma-Hock; Ben van Ravenzwaay; Robert Landsiedel
A major health concern for nanomaterials is their potential toxic effect after inhalation of dusts. Correspondingly, the core element of tier 1 in the currently proposed integrated testing strategy (ITS) is a short-term rat inhalation study (STIS) for this route of exposure. STIS comprises a comprehensive scheme of biological effects and marker determination in order to generate appropriate information on early key elements of pathogenesis, such as inflammatory reactions in the lung and indications of effects in other organs. Within the STIS information on the persistence, progression and/or regression of effects is obtained. The STIS also addresses organ burden in the lung and potential translocation to other tissues. Up to now, STIS was performed in research projects and routine testing of nanomaterials. Meanwhile, rat STIS results for more than 20 nanomaterials are available including the representative nanomaterials listed by the Organization for Economic Cooperation and Development (OECD) working party on manufactured nanomaterials (WPMN), which has endorsed a list of representative manufactured nanomaterials (MN) as well as a set of relevant endpoints to be addressed. Here, results of STIS carried out with different nanomaterials are discussed as case studies. The ranking of different nanomaterials potential to induce adverse effects and the ranking of the respective NOAEC are the same among the STIS and the corresponding subchronic and chronic studies. In another case study, a translocation of a coated silica nanomaterial was judged critical for its safety assessment. Thus, STIS enables application of the proposed ITS, as long as reliable and relevant in vitro methods for the tier 1 testing are still missing. Compared to traditional subacute and subchronic inhalation testing (according to OECD test guidelines 412 and 413), STIS uses less animals and resources and offers additional information on organ burden and progression or regression of potential effects.
Toxicology in Vitro | 2014
Tzutzuy Ramirez; Annette Mehling; Susanne N. Kolle; Christoph Jan Wruck; Wera Teubner; Tobias Eltze; Alexandra Aumann; Daniel Urbisch; Ben van Ravenzwaay; Robert Landsiedel
Allergic contact dermatitis can develop following repeated exposure to allergenic substances. To date, hazard identification is still based on animal studies as non-animal alternatives have not yet gained global regulatory acceptance. Several non-animal methods addressing key-steps of the adverse outcome pathway (OECD, 2012) will most likely be needed to fully address this effect. Among the initial cellular events is the activation of keratinocytes and currently only one method, the KeratinoSens™, has been formally validated to address this event. In this study, a further method, the LuSens assay, that uses a human keratinocyte cell line harbouring a reporter gene construct composed of the antioxidant response element (ARE) of the rat NADPH:quinone oxidoreductase 1 gene and the luciferase gene. The assay was validated in house using a selection of 74 substances which included the LLNA performance standards. The predictivity of the LuSens assay for skin sensitization hazard identification was comparable to other non-animal methods, in particular to the KeratinoSens™. When used as part of a testing battery based on the OECD adverse outcome pathway for skin sensitization, a combination of the LuSens assay, the DPRA and a dendritic cell line activation test attained predictivities similar to that of the LLNA.
Frontiers in Neuroengineering | 2011
Enrico Defranchi; Antonio Novellino; Maurice Whelan; Sandra Vogel; Tzutzuy Ramirez; Ben van Ravenzwaay; Robert Landsiedel
Detection and characterization of chemically induced toxic effects in the nervous system represent a challenge for the hazard assessment of chemicals. In vivo, neurotoxicological assessments exploit the fact that the activity of neurons in the central and peripheral nervous system has functional consequences. And so far, no in vitro method for evaluating the neurotoxic hazard has yet been validated and accepted for regulatory purpose. The micro-electrode array (MEA) assay consists of a culture chamber into which an integrated array of micro-electrodes is capable of measuring extracellular electrophysiology (spikes and bursts) from electro-active tissues. A wide variety of electrically excitable biological tissues may be placed onto the chips including primary cultures of nervous system tissue. Recordings from this type of in vitro cultured system are non-invasive, give label free evaluations and provide a higher throughput than conventional electrophysiological techniques. In this paper, 20 substances were tested in a blinded study for their toxicity and dose–response curves were obtained from fetal rat cortical neuronal networks coupled to MEAs. The experimental procedure consisted of evaluating the firing activity (spiking rate) and modification/reduction in response to chemical administration. Native/reference activity, 30 min of activity recording per dilution, plus the recovery points (after 24 h) were recorded. The preliminary data, using a set of chemicals with different mode-of-actions (13 known to be neurotoxic, 2 non-neuroactive and not toxic, and 5 non-neuroactive but toxic) show good predictivity (sensitivity: 0.77; specificity: 0.86; accuracy: 0.85). Thus, the MEA with a neuronal network has the potency to become an effective tool to evaluate the neurotoxicity of substances in vitro.
Toxicology in Vitro | 2011
Christine Jäckh; V. Blatz; Eric Fabian; Katharina Guth; Ben van Ravenzwaay; Kerstin Reisinger; Robert Landsiedel
With the perspective to use human reconstructed skin models for genotoxicity testing which require metabolic activation of xenobiotics, this study aimed to characterize activities of biotransforming enzymes within two human reconstructed skin models, the epidermis model EpiDerm™ (MatTek) and the Phenion® Full-Thickness skin model Phenion®FT (Henkel). According to existing gene expression profiles, Cytochrome P450 (CYP) enzymes, Flavin-dependent monooxygenases (FMO), N-acetyltransferases (NAT) and UDP-glucuronyltransferases (UDP-GT) were investigated in S9 or microsomal fractions. CYP-catalyzed monooxygenation was assayed using 7-ethoxyresorufin, pentoxyresorufin and benzyloxyresorufin as substrates. FMO activity was tested using benzydamine. Conjugating activities of NAT and UDP-GT were determined by acetylation of p-aminobenzoic acid or glucuronation of 4-methylumbelliferone, respectively. Although CYPs were detected by expression profiling, no CYP activity was detected in either the epidermal nor the full-thickness reconstructed skin model while expression and activity of FMO, UDP-GT and NAT were demonstrated in both.
Toxicology in Vitro | 2015
Katharina Guth; Monika Schäfer-Korting; Eric Fabian; Robert Landsiedel; Ben van Ravenzwaay
Skin absorption testing in vitro is a regulatory accepted alternative method (OECD Guideline 428). Different tests can be applied to evaluate the integrity of the skin samples. Here, we compared the pre- or post-run integrity tests (transepidermal electrical resistance, TEER; transepidermal water loss, TEWL; absorption of the reference compounds water, TWF, or methylene blue, BLUE) and additionally focused on co-absorption of a (3)H-labeled internal reference standard (ISTD) as integrity parameter. The results were correlated to absorption profiles of various test compounds. Limit values of 2kΩ, 10 gm(-2)h(-1) and 4.5∗10(-3)cmh(-1) for the standard methods TEER, TEWL and TWF, respectively, allowed distinguishing between impaired and intact human skin samples in general. Single skin samples did, however, not, poorly and even inversely correlate with the test-compound absorption. In contrast, results with ISTD (e.g. (3)H-testosterone) were highly correlated to the absorption of (14)C-labeled test compounds. Importantly, ISTD did not influence analytics or absorption of test compounds. Therefore, ISTD, especially when adjusted to the physico-chemical properties of test compounds, is a promising concept to assess the integrity of skin samples during the whole course of absorption experiments. However, a historical control dataset is yet necessary for a potential routine application.
Archives of Toxicology | 2017
Marcel Leist; Ahmed Ghallab; Rabea Graepel; Rosemarie Marchan; Reham Hassan; Susanne Hougaard Bennekou; Alice Limonciel; Mathieu Vinken; Stefan Schildknecht; Tanja Waldmann; Erik H. J. Danen; Ben van Ravenzwaay; Hennicke Kamp; Iain Gardner; Patricio Godoy; Frédéric Y. Bois; Albert Braeuning; Raymond Reif; Franz Oesch; Dirk Drasdo; Stefan Höhme; Michael Schwarz; Thomas Hartung; Thomas Braunbeck; Joost B. Beltman; Harry Vrieling; Ferran Sanz; Anna Forsby; Domenico Gadaleta; Ciarán Fisher
Adverse outcome pathways (AOPs) are a recent toxicological construct that connects, in a formalized, transparent and quality-controlled way, mechanistic information to apical endpoints for regulatory purposes. AOP links a molecular initiating event (MIE) to the adverse outcome (AO) via key events (KE), in a way specified by key event relationships (KER). Although this approach to formalize mechanistic toxicological information only started in 2010, over 200 AOPs have already been established. At this stage, new requirements arise, such as the need for harmonization and re-assessment, for continuous updating, as well as for alerting about pitfalls, misuses and limits of applicability. In this review, the history of the AOP concept and its most prominent strengths are discussed, including the advantages of a formalized approach, the systematic collection of weight of evidence, the linkage of mechanisms to apical end points, the examination of the plausibility of epidemiological data, the identification of critical knowledge gaps and the design of mechanistic test methods. To prepare the ground for a broadened and appropriate use of AOPs, some widespread misconceptions are explained. Moreover, potential weaknesses and shortcomings of the current AOP rule set are addressed (1) to facilitate the discussion on its further evolution and (2) to better define appropriate vs. less suitable application areas. Exemplary toxicological studies are presented to discuss the linearity assumptions of AOP, the management of event modifiers and compensatory mechanisms, and whether a separation of toxicodynamics from toxicokinetics including metabolism is possible in the framework of pathway plasticity. Suggestions on how to compromise between different needs of AOP stakeholders have been added. A clear definition of open questions and limitations is provided to encourage further progress in the field.
Wiley Interdisciplinary Reviews-nanomedicine and Nanobiotechnology | 2012
Robert Landsiedel; Lan Ma-Hock; Hans-Juergen Haussmann; Ben van Ravenzwaay; Martin Kayser; Karin Wiench
While technical and medical potential offered by nanotechnologies increase, the safety assessment of engineered nanomaterials (NMs) needs to follow this pace. Inhalation is a major route of occupational and environmental exposure, and is most relevant for most of the respective safety assessment studies. Control and generation of aerosol from the test materials for this route of administration are technically demanding, and not surprisingly, there are relatively few NMs tested in toxicokinetic, short-term, and subchronic inhalation studies. These studies were in part adapted to the peculiarities of inhaled NMs, but few were also conducted according to organization for economic co-operation and development (OECD) test guidelines. Inhalation studies on the potential to develop chronic diseases, or studies to check the potential analogy to cardiovascular diseases associated with adverse health effects from ambient air pollution, are largely missing. On the way forward, appropriate inhalation studies need to be performed on a number of NMs to assess their hazards and to provide a sound database for correlation and validation of alternative in vitro methods. Moreover, these studies can potentially aid in the grouping of different NMs based on their biokinetics or biological effects. For carcinogenic and cardiovascular effects, research studies are needed to verify-or disprove-the relevance and the mechanisms by which NMs contribute to these effects.
Journal of Physics: Conference Series | 2011
Wendel Wohlleben; Susanne N. Kolle; Laura-Carolin Hasenkamp; Alexander Böser; Sandra Vogel; Bernhard von Vacano; Ben van Ravenzwaay; Robert Landsiedel
We used precision cut lung slices (PCLS) to study the cytotoxicity of cobalt ferrite nanomaterials with and without bovine serum albumin (BSA) stabilization. Using mitochondrial activity as an indicator of cytotoxicity (WST-1 assay) increasing concentrations of cobalt ferrite nanomaterial caused increasing levels of cytotoxicity in PCLS irrespective of BSA stabilization. However, there was no increase in released lactate dehydrogenase (LDH) levels caused by BSA stabilized nanomaterial indicating concentration depended cytotoxictiy. Moreover, non-stabilized nanomaterial caused a decrease of background LDH levels in the PCLS culture supernatant confirmed by complementary methods. Direct characterization of the protein corona of extracted nanomaterial shows that the LDH decrease is due to adsorption of LDH onto the surface of the non-stabilized nanomaterial, correlated with strong agglomeration. Preincubation with serum protein blocks the adsorption of LDH and stabilizes the nanomaterial at low agglomeration. We have thus demonstrated the cytotoxicity of nanomaterials in PCLS does not correlate with disrupted membrane integrity followed by LDH release. Furthermore, we found that intracellular enzymes such as the marker enzyme LDH are able to bind onto surfaces of nanomaterial and thereby adulterate the detection of toxic effects. A replacement of BSA by LDH or a secondary LDH-on-BSA-corona were not observed, confirming earlier indications that the protein corona exchange rate are slow or vanishing on inorganic nanomaterial. Thus, the method(s) to assess nanomaterial-mediated effects have to be carefully chosen based on the cellular effect and possible nano-specific artifacts.
Alternatives to Animal Experimentation : ALTEX | 2014
Grace Patlewicz; Nicholas Ball; Richard A. Becker; Ewan D. Booth; Mark T. D. Cronin; Dinant Kroese; David Steup; Ben van Ravenzwaay; Thomas Hartung
Read-across is a data gap filling technique used within category and analogue approaches. It has been utilized as an alternative approach to address information requirements under various past and present regulatory programs such as the OECD High Production Volume Programme as well as the EUs Registration, Evaluation, Authorisation and restriction of CHemicals (REACH) regulation. Although read-across raises a number of expectations, many misconceptions still remain around what it truly represents; how to address its associated justification in a robust and scientifically credible manner; what challenges/issues exist in terms of its application and acceptance; and what future efforts are needed to resolve them. In terms of future enhancements, read-across is likely to embrace more biologically-orientated approaches consistent with the Toxicity in the 21st Century vision (Tox-21c). This Food for Thought article, which is notably not a consensus report, aims to discuss a number of these aspects and, in doing so, to raise awareness of the ongoing efforts and activities to enhance read-across. It also intends to set the agenda for a CAAT read-across initiative in 2014-2015 to facilitate the proper use of this technique.