Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Benjamin Craiovan is active.

Publication


Featured researches published by Benjamin Craiovan.


International Orthopaedics | 2014

Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate

Benjamin Craiovan; Tobias Renkawitz; Markus Weber; Joachim Grifka; Lutz-Peter Nolte; Guoyan Zheng

PurposeMalposition of the acetabular component in total hip arthroplasty (THA) is a common surgical problem that can lead to hip dislocation, reduced range of motion and may result in early loosening. The aim of this study is to validate the accuracy and reproducibility of a single x-ray image based 2D/3D reconstruction technique in determining cup inclination and anteversion against two different computer tomography (CT)-based measurement techniques.MethodsCup anteversion and inclination of 20 patients after cementless primary THA was measured on standard antero-posterior (AP) radiographs with the help of the single x-ray 2D/3D reconstruction program and compared with two different 3D CT-based analyses [Ground Truth (GT) and MeVis (MV) reconstruction model].ResultsThe measurements from the single x-ray 2D/3D reconstruction technique were strongly correlated with both types of CT image-processing protocols for both cup inclination [R²=0.69 (GT); R²=0.59 (MV)] and anteversion [R²=0.89 (GT); R²=0.80 (MV)].ConclusionsThe single x-ray image based 2D/3D reconstruction technique is a feasible method to assess cup position on postoperative x-rays. CT scans remain the golden standard for a more complex biomechanical evaluation when a lower tolerance limit (+/-2 degrees) is required.


Acta Orthopaedica | 2016

Visual intraoperative estimation of cup and stem position is not reliable in minimally invasive hip arthroplasty

Michael Woerner; Ernst Sendtner; Robert Springorum; Benjamin Craiovan; Michael Worlicek; Tobias Renkawitz; Joachim Grifka; Markus Weber

Background and purpose — In hip arthroplasty, acetabular inclination and anteversion—and also femoral stem torsion—are generally assessed by eye intraoperatively. We assessed whether visual estimation of cup and stem position is reliable. Patients and methods — In the course of a subgroup analysis of a prospective clinical trial, 65 patients underwent cementless hip arthroplasty using a minimally invasive anterolateral approach in lateral decubitus position. Altogether, 4 experienced surgeons assessed cup position intraoperatively according to the operative definition by Murray in the anterior pelvic plane and stem torsion in relation to the femoral condylar plane. Inclination, anteversion, and stem torsion were measured blind postoperatively on 3D-CT and compared to intraoperative results. Results — The mean difference between the 3D-CT results and intraoperative estimations by eye was −4.9° (−18 to 8.7) for inclination, 9.7° (−16 to 41) for anteversion, and −7.3° (−34 to 15) for stem torsion. We found an overestimation of > 5° for cup inclination in 32 hips, an overestimation of > 5° for stem torsion in 40 hips, and an underestimation < 5° for cup anteversion in 42 hips. The level of professional experience and patient characteristics had no clinically relevant effect on the accuracy of estimation by eye. Altogether, 46 stems were located outside the native norm of 10–20° as defined by Tönnis, measured on 3D-CT. Interpretation — Even an experienced surgeon’s intraoperative estimation of cup and stem position by eye is not reliable compared to 3D-CT in minimally invasive THA. The use of mechanical insertion jigs, intraoperative fluoroscopy, or imageless navigation is recommended for correct implant insertion.


Journal of Orthopaedic Trauma | 2014

Fracture prevention by prophylactic femoroplasty of the proximal femur--metallic compared with cemented augmentation.

Hans-Robert Springorum; Matthias Gebauer; Alexander Mehrl; Olaf Stark; Benjamin Craiovan; Klaus Püschel; Michael Amling; Joachim Grifka; Johannes Beckmann

OBJECTIVES To compare 2 different femoral neck augmentation techniques at improving the mechanical strength of the femoral neck. METHODS Twenty pairs of human cadaveric femora were randomly divided into 2 groups. In 1 group, the femora were augmented with a steel spiral; the other group with the cemented technique. The untreated contralateral side served as an intraindividual control. Fracture strength was evaluated using an established biomechanical testing scenario mimicking a fall on the greater trochanter (Hayes fall). RESULTS The peak load to failure was significantly higher in the steel spiral group (P = 0.0024) and in the cemented group (P = 0.001) compared with the intraindividual controls. The peak load to failure showed a median of 3167 N (1825-5230 N) in the spiral group and 2485 N (1066-4395 N) in the spiral control group. The peak load to failure in the cemented group was 3698 N (SD ± 1249 N) compared with 2763 N (SD ± 1335 N) in the cement control group. Furthermore, fracture displacement was clearly reduced in the steel spiral group. CONCLUSIONS Femoral augmentations using steel spirals or cement-based femoroplasty are technically feasible procedures. Our results demonstrate that a prophylactic reinforced proximal femur has higher strength when compared with the untreated contralateral limb. Prophylactic augmentation has potential to become an auxiliary treatment option to protect the osteoporotic proximal femur against fracture.Objectives: To compare 2 different femoral neck augmentation techniques at improving the mechanical strength of the femoral neck. Methods: Twenty pairs of human cadaveric femora were randomly divided into 2 groups. In 1 group, the femora were augmented with a steel spiral; the other group with the cemented technique. The untreated contralateral side served as an intraindividual control. Fracture strength was evaluated using an established biomechanical testing scenario mimicking a fall on the greater trochanter (Hayes fall). Results: The peak load to failure was significantly higher in the steel spiral group (P = 0.0024) and in the cemented group (P = 0.001) compared with the intraindividual controls. The peak load to failure showed a median of 3167 N (1825–5230 N) in the spiral group and 2485 N (1066–4395 N) in the spiral control group. The peak load to failure in the cemented group was 3698 N (SD ± 1249 N) compared with 2763 N (SD ± 1335 N) in the cement control group. Furthermore, fracture displacement was clearly reduced in the steel spiral group. Conclusions: Femoral augmentations using steel spirals or cement-based femoroplasty are technically feasible procedures. Our results demonstrate that a prophylactic reinforced proximal femur has higher strength when compared with the untreated contralateral limb. Prophylactic augmentation has potential to become an auxiliary treatment option to protect the osteoporotic proximal femur against fracture.


International Orthopaedics | 2015

The impact of standard combined anteversion definitions on gait and clinical outcome within one year after total hip arthroplasty

Markus Weber; Tim Weber; Michael Woerner; Benjamin Craiovan; Michael Worlicek; Sebastian Winkler; Joachim Grifka; Tobias Renkawitz

PurposeDifferent target areas within the concept of combined cup and stem anteversion have been published for total hip arthroplasty (THA). We asked whether component positioning according to eight standard combined anteversion rules is associated with (1) more physiological gait patterns, (2) higher improvement of gait variables and (3) better clinical outcome after THA.MethodsIn a prospective clinical study, 60 patients received cementless THA through an anterolateral MIS approach in a lateral decubitus position. Six weeks postoperatively, implant position was analysed using 3D-CT by an independent external institute. Preoperatively, six and 12 months postoperatively range of motion, normalized walking speed and hip flexion symmetry index were measured using 3D motion-capture gait analysis. Patient-related outcome measures (HHS, HOOS, EQ-5D) were obtained by an observer blinded to 3D-CT results. Eight combined anteversion definitions and Lewinnek’s “safe zone” were evaluated regarding their impact on gait patterns and clinical outcome.ResultsCombined cup and stem anteversion according to standard combined anteversion definitions as well as cup placement within Lewinnek’s “safe zone” did not influence range of motion, normalized walking speed and/or hip flexion symmetry index six and 12 months after THA. Similarly, increase of gait parameters within the first year after THA was comparable between all eight combined anteversion rules. Clinical outcome measures like HHS, HOOS and EQ-5D did not show any benefit for either of the combined anteversion definitions.ConclusionsStandard combined cup and stem anteversion rules do not improve postoperative outcome as measured by gait analysis and clinical scores within one year after THA.


International Orthopaedics | 2017

Accuracy of measuring acetabular cup position after total hip arthroplasty: comparison between a radiographic planning software and three-dimensional computed tomography

Vahdettin Bayraktar; Markus Weber; Frederik von Kunow; Florian Zeman; Benjamin Craiovan; Tobias Renkawitz; Joachim Grifka; Michael Woerner

PurposeVarious methods are available for measuring acetabular cup position after total hip arthroplasty (THA) on standard anterior-posterior (AP) radiographs. We compared the accuracy of a commercial radiographic planning software program with that of three-dimensional computed tomography (3D-CT) scans.MethodsWe obtained plain AP radiographs and 3D-CTs from 65 patients after THA. In addition to calculating cup anteversion and inclination with 3D-CT, we determined the cup position using the radiographic planning software program mediCAD® 2.5 (Hectec, Niederviehbach, Germany). Furthermore, we compared the measurements using the inter-teardrop and bi-ischial lines as pelvic landmarks.ResultsThe mean difference in anteversion between 3D-CT and mediCAD® software was 0.1° using the inter-teardrop line (standard deviation [SD], 8.8°; range, −21° to 23°; p = 0.97) and 0.4° using the bi-ischial line (SD, 8.8°; range, −23° to 21°; p = 0.72). Inclination showed a mean difference of 0.6° using the inter-teardrop line (SD, 4.4°; range, −9° to 21°; p = 0.24) and 0.5° using bi-ischial line (SD, 4.6°; range, −9° to 22°; p = 0.35). The means for absolute differences were 7.2° for anteversion and 3.1° for inclination. With regard to using the bi-ischial or inter-teardrop line, no significant difference was found between the two pelvic landmarks. The intra-class correlation coefficient (ICC) was analysed for anteversion and inclination using either the inter-teardrop line or the bi-ischial line as radiographic baseline.ConclusionsA radiographic planning software program (mediCAD®) is a helpful tool for measuring cup inclination on AP radiographs. With respect to anteversion, measurements are rather susceptible to mistakes with mean inaccuracies of over 7°. Thus, 3D-CT remains the “gold standard” if a lower tolerance limit (±3°) is required for more complex biomechanical evaluations. As a pelvic landmark, the interteardrop line is preferential to the bi-ischial line because of its lower impact on the position of the pelvis.


International Orthopaedics | 2017

Soft tissue restricts impingement-free mobility in total hip arthroplasty

Michael Woerner; Markus Weber; Ernst Sendtner; Robert Springorum; Michael Worlicek; Benjamin Craiovan; Joachim Grifka; Tobias Renkawitz

PurposeImpingement is a major source for decreased range of motion (ROM) and dislocation in total hip arthroplasty (THA). In the current study we analyzed the impact of soft tissue impingement on ROM compared to bony and/or prosthetic impingement.MethodsIn the course of a prospective clinical trial 54 patients underwent cementless total hip arthroplasty in the lateral decubitus position using imageless navigation. The navigation device enabled intra-operative ROM measurements indicating soft tissue impingement. Post-operatively, all patients received postoperative 3D-CT. Absolute ROM without bony and/or prosthetic impingement was calculated with the help of a collision-detection-algorithm.ResultsDue to soft tissue impingement we found a reduced ROM of over 20° (p < 0.001) compared to bony and/or prosthetic impingement regarding flexion, extension, abduction and adduction and of over 10° regarding external rotation (p < 0.001). In contrast, soft tissue impingement showed less impact on internal rotation in 90° of flexion (p = 0.76). Multivariate analysis showed an association between BMI and flexion, whereas all other ROM directions were independent of BMI.ConclusionsSoft tissue has a major impact on impingement-free ROM after THA. For the majority of movements, soft tissue restrictions are more important than bony and prosthetic impingement. Future models of patient individual joint replacement including pre-operative (CT) planning and intra-operative navigation should include algorithms additionally accounting for soft tissue impingement.


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 2016

Measuring Acetabular Cup Orientation on Antero-Posterior Radiographs of the Hip after Total Hip Arthroplasty with a Vector Arithmetic Radiological Method. Is It Valid and Verified for Daily Clinical Practice?

Benjamin Craiovan; Markus Weber; Michael Worlicek; M. Schneider; H. R. Springorum; Florian Zeman; Joachim Grifka; Tobias Renkawitz

PURPOSE The aim of this prospective study is to validate a vector arithmetic method for measuring acetabular cup orientation after total hip arthroplasty (THA) and to verify the clinical practice. MATERIALS AND METHODS We measured cup anteversion and inclination of 123 patients after cementless primary THA twice by two examiners on AP pelvic radiographs with a vector arithmetic method and compared with a 3D-CT based reconstruction model within the same radiographic coronal plane. RESULTS The mean difference between the radiographic and the 3D-CT measurements was - 1.4° ± 3.9° for inclination and 0.8°± 7.9° for anteversion with excellent correlation for inclination (r = 0.81, p < 0.001) and moderate correlation for anteversion (r = 0.65, p < 0.001). The intraclass correlation coefficient for measurements on radiographs ranged from 0.98 (95 %-CI: 0.98; 0.99) for the first observer to 0.94 (95 %-CI: 0.92; 0.96) for the second observer. The interrater reliability was 0.96 (95 %-CI: 0.93; 0.98) for inclination and 0.93 (95 %-CI: 0.85; 0.96) for anteversion. CONCLUSION The largest errors in measurements were associated with an extraordinary pelvic tilt. In order to get a valuable measurement for measuring cup position after THA on pelvic radiographs by this vector arithmetic method, there is a need for a correct postoperative ap view, with special regards to the pelvic tilt for the future. KEY POINTS • Measuring acetabular cup orientation on anteroposterior radiographs of the hip after THA is a helpful procedure in everyday clinical practice as a first-line imaging modality• CT remains the golden standard to accurately determine acetabular cup position.• Future measuring on radiographs for cup orientation after THA should account for integration of the pelvic tilt in order to maximize the measurement accuracy. Citation Format: • Craiovan B, Weber M, Worlicek M et al. Measuring Acetabular Cup Orientation on Antero-Posterior Radiographs of the Hip after Total Hip Arthroplasty with a Vector Arithmetic Radiological Method. Is It Valid and Verified for Daily Clinical Practice?. Fortschr Röntgenstr 2016; 188: 574 - 581.


Orthopaedics & Traumatology-surgery & Research | 2015

Difference in periprosthetic acetabular bone mineral density: Prior total hip arthroplasty: Osteonecrosis of the femoral head versus primary osteoarthritis.

Benjamin Craiovan; Michael Wörner; Günther Maderbacher; Joachim Grifka; Tobias Renkawitz; Armin Keshmiri

BACKGROUND Total hip arthroplasty (THA) could be associated with a higher failure rate in patients after osteonecrosis of the femoral head (ONFH) compared to a patient population with primary osteoarthritis prior THA, especially regarding the acetabular component. One major reason could be the compromised acetabular bone quality. Therefore, we performed a retrospective case matched study to assess: 1) Is there a difference in periprosthetic bone mineral density between patients with an ONFH prior THA and controls? 2) Do patients with an ONFH prior THA have a lower bone mineral density compared to controls? 3) Which region in the periprosthetic bone stock is more likely to present differences in periprosthetic bone mineral density between both groups? HYPOTHESIS We hypothesized that there is a poorer bone mineral density (BMD) in the periacetabular bone stock in patients with an ONFH prior THA compared to controls receiving a THA due to primary osteoarthritis. PATIENTS AND METHODS We compared the BMD of 50 patients with ONFH to 50 controls with primary osteoarthritis prior THA using the same implant in mean 5 years after surgery by means of dual energy X-ray absorptiometry (DXA). We analysed 3 acetabular ROIs according to DeLee and Charnley in a modified measurement technique. RESULTS In ROI 3, representing acetabulums upper aspect, statistically significant lower BMD values for the ONFH group could be found (P < 0.05). No difference was found for the modified ROIs 1 and 2 (respectively medial and lower acetabulum). DISCUSSION The results indicate a poorer periacetabular BMD in patients with ONFH prior THA, which might be responsible for premature loosening of the acetabular cup in THA. Due to a lack of literature, further clinical investigations are required to confirm our results. LEVEL OF EVIDENCE III: retrospective case-control study.


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 2017

Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA – An Experimental Study

Timo Schwarz; Markus Weber; Christian Dornia; Michael Worlicek; Tobias Renkawitz; Joachim Grifka; Benjamin Craiovan

Purpose Accurate assessment of cup orientation on postoperative pelvic radiographs is essential for evaluating outcome after THA. Here, we present a novel method for correcting measurement inaccuracies due to pelvic tilt and rotation. Method In an experimental setting, a cup was implanted into a dummy pelvis, and its final position was verified via CT. To show the effect of pelvic tilt and rotation on cup position, the dummy was fixed to a rack to achieve a tilt between + 15° anterior and -15° posterior and 0° to 20° rotation to the contralateral side. According to Murrays definitions of anteversion and inclination, we created a novel corrective procedure to measure cup position in the pelvic reference frame (anterior pelvic plane) to compensate measurement errors due to pelvic tilt and rotation. Results The cup anteversion measured on CT was 23.3°; on AP pelvic radiographs, however, variations in pelvic tilt (± 15°) resulted in anteversion angles between 11.0° and 36.2° (mean error 8.3°± 3.9°). The cup inclination was 34.1° on CT and ranged between 31.0° and 38.7° (m. e. 2.3°± 1.5°) on radiographs. Pelvic rotation between 0° and 20° showed high variation in radiographic anteversion (21.2°-31.2°, m. e. 6.0°± 3.1°) and inclination (34.1°-27.2°, m. e. 3.4°± 2.5°). Our novel correction algorithm for pelvic tilt reduced the mean error in anteversion measurements to 0.6°± 0.2° and in inclination measurements to 0.7° (SD± 0.2). Similarly, the mean error due to pelvic rotation was reduced to 0.4°± 0.4° for anteversion and to 1.3°± 0.8 for inclination. Conclusion Pelvic tilt and pelvic rotation may lead to misinterpretation of cup position on anteroposterior pelvic radiographs. Mathematical correction concepts have the potential to significantly reduce these errors, and could be implemented in future radiological software tools. Key Points  · Pelvic tilt and rotation influence cup orientation after THA. · Cup anteversion and inclination should be referenced to the pelvis. · Radiological measurement errors of cup position may be reduced by mathematical concepts. Citation Format · Schwarz TJ, Weber M, Dornia C et al. Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA - An Experimental Study. Fortschr Röntgenstr 2017; 189: 864 - 873.


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 2016

Digital Planning Software Fails to Reflect Stem Torsion on Plain Radiographs after Total Hip Arthroplasty.

Michael Worlicek; Markus Weber; Florian Zeman; Michael Wörner; M. Schneider; Joachim Grifka; Tobias Renkawitz; Benjamin Craiovan

PURPOSE The purpose of this study was to evaluate the validity of commercially available planning software on plain radiographs after THA compared to CT scans as the gold standard. PATIENTS AND METHODS In a prospective clinical study, anteroposterior (AP) radiographs and three-dimensional CT scans (3D-CT) were obtained for 121 patients, who underwent minimally invasive, cementless THA with a straight tapered stem, in a lateral decubitus position. For measuring SV, we used digital planning software (TraumaCad 2.0, BrainLAB Feldkirchen, Germany). Two independent raters repeated the analysis after a six-week interval. Radiological measurements were compared with 3D-CT measurements by an independent, blinded external institute. This investigation was approved by the local ethics commission (no. 10 -121- 0263) and is a secondary analysis of a larger project (DRKS00 000 739, German Clinical Trials Register May-02 - 2011). RESULTS The radiograph measurements showed very high intra- and interrater agreement. The intra-class correlation (ICC) of the intrarater agreement was 0.97 for rater 1 and 0.98 for rater 2. The intrarater reliability was 0.99 using the mean values of both rater measurements. The mean difference between the average radiograph measurement and the 3D-CT-based measurement was 0.41° (SD 11.24°) (range: -33.85°-22.50°; 95 % limits of agreement: -21.63 - 22.45), but there was no correlation found between both methods. CONCLUSION Measuring stem version with the help of commercially available digital planning software on plain radiographs after THA has high intra- and interrater reliability but clinically inacceptable validity and reliability when compared to 3D-CT scans. KEY POINTS • Measuring stem torsion after THA on plain radiographs with digital planning software is not valid. Citation Format: • Worlicek M, Weber M, Zeman F et al. Digital Planning Software Fails to Reflect Stem Torsion on Plain Radiographs after Total Hip Arthroplasty. Fortschr Röntgenstr 2016; 188: 763 - 767.

Collaboration


Dive into the Benjamin Craiovan's collaboration.

Top Co-Authors

Avatar

Joachim Grifka

University of Regensburg

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Markus Weber

Kantonsspital St. Gallen

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Armin Keshmiri

University of Regensburg

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Florian Zeman

University of Regensburg

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge