Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Benjamin Schäffer is active.

Publication


Featured researches published by Benjamin Schäffer.


Journal of the American College of Cardiology | 2015

Pulmonary Vein Isolation Versus Defragmentation: The CHASE-AF Clinical Trial.

Julia Vogler; Stephan Willems; Arian Sultan; Doreen Schreiber; Jakob Lüker; Helge Servatius; Benjamin Schäffer; Julia Moser; Boris A. Hoffmann; Daniel Steven

BACKGROUND Long-term success rates using ablation for persistent atrial fibrillation (AF) are disappointing and usually do not exceed 60%. OBJECTIVES This study sought to compare arrhythmia-free survival between pulmonary vein isolation (PVI) and a stepwise approach (full defrag) consisting of PVI, ablation of complex fractionated electrograms, and additional linear ablation lines in the setting of atrial tachycardias (AT) in patients with persistent AF after PVI. METHODS From November 2010 to February 2013, 205 patients (151 men; 61.7 ± 10.2 years of age) underwent de novo ablation for persistent AF. Subsequently, patients were prospectively randomized to either PVI alone (n = 78) or full defrag (n = 75), with 52 patients not randomized due to AF termination with the original PVI. The primary endpoint was recurrence of any AT after a blanking period of 3 months. RESULTS During the entire study, 241 ablations were performed (mean: 1.59 in the PVI-alone group, 1.55 in the full-defrag group). With the stepwise approach, termination of AF occurred in 45 (60%) patients. However, arrhythmia-free survival did not differ whether patients underwent single or multiple procedures (p = 0.468). Procedure duration, fluoroscopy time, and radiofrequency duration were significantly longer in the full-defrag group (all p < 0.001). CONCLUSIONS A stepwise approach aimed at AF termination does not seem to provide additional benefit over PVI alone in patients with persistent AF, but it is associated with significantly longer procedural and fluoroscopic duration as well as radiofrequency application time. (The Randomized Catheter Ablation of Persist End Atrial Fibrillation Study [CHASE-AF]; NCT01580124).


Circulation-arrhythmia and Electrophysiology | 2015

Five-Year Follow-Up After Catheter Ablation of Persistent Atrial Fibrillation Using the Stepwise Approach and Prognostic Factors for Success

Doreen Schreiber; Thomas Rostock; Max Fröhlich; Arian Sultan; Helge Servatius; Boris A. Hoffmann; Jakob Lüker; Imke Berner; Benjamin Schäffer; Karl Wegscheider; Susanne Lezius; Stephan Willems; Daniel Steven

Background—In the meantime, catheter ablation is widely used for the treatment of persistent atrial fibrillation (AF). There is a paucity of data about long-term outcomes. This study evaluates (1) 5-year single and multiple procedure success and (2) prognostic factors for arrhythmia recurrences after catheter ablation of persistent AF using the stepwise approach aiming at AF termination. Methods and Results—A total of 549 patients with persistent AF underwent de novo catheter ablation using the stepwise approach (2007–2009). A total of 493 patients were included (Holter ECGs ≥every 6 months). Mean follow-up was 59±16 months with 2.1±1.1 procedures per patient. Single and multiple procedure success rates were 20.1% and 55.9%, respectively (80% off antiarrhythmic drug). Antiarrhythmic drug–free multiple procedure success was 46%. Long-term recurrences (n=171) were paroxysmal AF in 48 patients (28%) and persistent AF/atrial tachycardia in 123 patients (72%). Multivariable recurrent event analysis revealed the following factors favoring arrhythmia recurrence: failure to terminate AF during index procedure (hazard ratio [HR], 1.279; 95% confidence interval [CI], 1.093–1.497; P=0.002), number of procedures (HR, 1.154; 95% CI, 1.051–1.267; P=0.003), female sex (HR, 1.263; 95% CI, 1.027–1.553; P=0.027), and the presence of structural heart disease (HR, 1.236; 95% CI, 1.003–1.524; P=0.047). AF termination was correlated with a higher rate of consecutive procedures because of atrial tachycardia recurrences (P=0.003; HR, 1.71; 95% CI, 1.20–2.43). Conclusions—Catheter ablation of persistent AF using the stepwise approach provides limited long-term freedom of arrhythmias often requiring multiple procedures. AF termination, the number of procedures, sex, and the presence of structural heart disease correlate with outcome success. AF termination is associated with consecutive atrial tachycardia procedures.


Journal of Cardiovascular Electrophysiology | 2017

Substrate characterization and catheter ablation in patients with scar-related ventricular tachycardia using ultra high-density 3-D mapping

Jana Mareike Nührich; Lukas Kaiser; Ruken Özge Akbulak; Benjamin Schäffer; Christian Eickholt; Michael Schwarzl Md; Pawel Kuklik; Julia Moser; Mario Jularic; Stephan Willems; Christian G. Meyer

Ablation of scar‐related ventricular tachycardia (VT), especially in noninducible VT or hemodynamically unstable patients, can be challenging. Thus, we evaluated feasibility of an ultra high‐density 3‐D mapping approach to characterize the ventricular substrate and, if possible, to map VT.


Journal of Cardiovascular Electrophysiology | 2015

Reduction of Radiation Exposure in Atrial Fibrillation Ablation Using a New Image Integration Module: A Prospective Randomized Trial in Patients Undergoing Pulmonary Vein Isolation

Ruken Özge Akbulak; Benjamin Schäffer; Mario Jularic; Julia Moser; Doreen Schreiber; Tim Salzbrunn; Christian G. Meyer; Christian Eickholt; Pawel Kuklik; Boris A. Hoffmann; Stephan Willems

Recently, a new image integration module (IIM, CartoUnivu™ Module) has been introduced to combine and merge fluoroscopy images with 3‐dimensional‐(3D)‐electroanatomical maps (Carto® 3 System) into an accurate 3D view. The aim of the study was to investigate the influence of IIM on the fluoroscopy exposure during pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) in a prospective randomized trial.


International Journal of Cardiology | 2015

Necessity of epicardial ablation for ventricular tachycardia after sequential endocardial approach

Arian Sultan; Jakob Lüker; Boris A. Hoffmann; Helge Servatius; Ali Aydin; Jana Mareike Nührich; Özge Akbulak; Doreen Schreiber; Benjamin Schäffer; Thomas Rostock; Stephan Willems; Daniel Steven

BACKGROUND Catheter ablation (CA) of ventricular tachycardia (VT) is an important treatment option in patients with structural heart disease (SHD) and implantable cardioverter defibrillator (ICD). A subset of patients requires epicardial CA for VT. OBJECTIVE The purpose of the study was to assess the significance of epicardial CA in these patients after a systematic sequential endocardial approach. METHODS Between January 2009 and October 2012 CA for VT was analyzed. A sequential CA approach guided by earliest ventricular activation, pacemap, entrainment and stimulus to QRS-interval analysis was used. Acute CA success was assessed by programmed ventricular stimulation. ICD interrogation and 24h-Holter ECG were used to evaluate long-term success. RESULTS One hundred sixty VT ablation procedures in 126 consecutive patients (114 men; age 65±12years) were performed. Endocardial CA succeeded in 250 (94%) out of 265 treated VT. For 15 (6%) VT an additional epicardial CA was performed and succeeded in 9 of these 15 VT. Long-term FU (25±18.2month) showed freedom of VT in 104 pts (82%) after 1.2±0.5 procedures, 11 (9%) suffered from repeated ICD shocks and 11 (9%) died due to worsening of heart failure. CONCLUSIONS Despite a heterogenic substrate for VT in SHD, endocardial CA alone results in high acute success rates. In this study additional epicardial CA following a sequential endocardial mapping and CA approach was performed in 6% of VT. Thus, due to possible complications epicardial CA should only be considered if endocardial CA fails.


Europace | 2016

Interventional management of recurrent paroxysmal atrial fibrillation despite isolated pulmonary veins: impact of an ablation strategy targeting inducible atrial tachyarrhythmias

Arian Sultan; Jakob Lüker; Boris A. Hoffmann; Helge Servatius; Benjamin Schäffer; Daniel Steven; Stephan Willems

AIMS Pulmonary vein isolation (PVI) is an effective treatment option for paroxysmal atrial fibrillation (PAF). Reconnection of pulmonary veins (PVs) is the predominant cause for recurrence of PAF. However, treatment of patients with recurrence of PAF despite isolated PV in the absence of extra-PV foci remains challenging. METHODS AND RESULTS Of 265 patients undergoing repeat catheter ablation (CA) for recurrence of PAF 21 (8%) patients (14 men, age 58 ± 14 years) showed no reconnection of PV. Therefore, inducibility of sustained atrial arrhythmias was tested. If sustained atrial fibrillation (AF) or sustained atrial tachycardia (AT) was induced, patients underwent CA. During follow-up (FU), Holter- and Tele-electrocardiogram were performed. In 19 (91%) of 21 patients, sustained atrial arrhythmias [16 (84%) AF; 3 (15%) patients AT] were induced. One patient showed PAF. Eighteen patients underwent CA aiming for termination of induced arrhythmia. In 14 (77%) patients, termination into sinus rhythm was achieved. Despite extensive CA, three (16%) patients were externally cardioverted. No periprocedural complications occurred. During 21.2 ± 6.8-month FU, 10 (53%) patients were free of any arrhythmia. Paroxysmal atrial fibrillation recurred in 4 (21%) and AT in 5 (26%) patients. One patient showed persistent AF. Repeat CA was scheduled and successfully performed for these patients. CONCLUSION In patients with recurrence of PAF despite isolated PV, termination of induced atrial arrhythmias can be achieved in most patients by defragmentation and AT ablation. Moreover, this ablation strategy results in favourable mid-term outcome results.


Europace | 2016

Propofol sedation administered by cardiologists for patients undergoing catheter ablation for ventricular tachycardia

Helge Servatius; Thormen Höfeler; Boris A. Hoffmann; Arian Sultan; Jakob Lüker; Benjamin Schäffer; Stephan Willems; Daniel Steven

AIMS Propofol sedation has been shown to be safe for atrial fibrillation ablation and internal cardioverter-defibrillator implantation but its use for catheter ablation (CA) of ventricular tachycardia (VT) has yet to be evaluated. Here, we tested the hypothesis that VT ablation can be performed using propofol sedation administered by trained nurses under a cardiologists supervision. METHODS AND RESULTS Data of 205 procedures (157 patients, 1.3 procedures/patient) undergoing CA for sustained VT under propofol sedation were analysed. The primary endpoint was change of sedation and/or discontinuation of propofol sedation due to side effects and/or haemodynamic instability. Propofol cessation was necessary in 24 of 205 procedures. These procedures (Group A; n = 24, 11.7%) were compared with those with continued propofol sedation (Group B; n = 181, 88.3%). Propofol sedation was discontinued due to hypotension (n = 22; 10.7%), insufficient oxygenation (n = 1, 0.5%), or hypersalivation (n = 1, 0.5%). Procedures in Group A were significantly longer (210 [180-260] vs. 180 [125-220] min, P = 0.005), had a lower per hour propofol rate (3.0 ± 1.2 vs. 3.8 ± 1.2 mg/kg of body weight/h, P = 0.004), and higher cumulative dose of fentanyl administered (0.15 [0.13-0.25] vs. 0.1 [0.05-0.13] mg, P < 0.001), compared with patients in Group B. Five (2.4%) adverse events occurred. CONCLUSION Sedation using propofol can be safely performed for VT ablation under the supervision of cardiologists. Close haemodynamic monitoring is required, especially in elderly patients and during lengthy procedures, which carrying a higher risk for systolic blood pressure decline.


PLOS ONE | 2016

Local Electrical Dyssynchrony during Atrial Fibrillation: Theoretical Considerations and Initial Catheter Ablation Results

Pawel Kuklik; Benjamin Schäffer; Boris A. Hoffmann; Anand N. Ganesan; Doreen Schreiber; Julia Moser; Ruken Özge Akbulak; Arian Sultan; Daniel Steven; Bart Maesen; Ulrich Schotten; Christian G. Meyer; Stephan Willems

Background Electrogram-based identification of the regions maintaining persistent Atrial Fibrillation (AF) is a subject of ongoing debate. Here, we explore the concept of local electrical dyssynchrony to identify AF drivers. Methods and Results Local electrical dyssynchrony was calculated using mean phase coherence. High-density epicardial mapping along with mathematical model were used to explore the link between local dyssynchrony and properties of wave conduction. High-density mapping showed a positive correlation between the dyssynchrony and number of fibrillatory waves (R2 = 0.68, p<0.001). In the mathematical model, virtual ablation at high dyssynchrony regions resulted in conduction regularization. The clinical study consisted of eighteen patients undergoing catheter ablation of persistent AF. High-density maps of left atrial (LA) were constructed using a circular mapping catheter. After pulmonary vein isolation, regions with the top 10% of the highest dyssynchrony in LA were targeted during ablation and followed with ablation of complex atrial electrograms. Catheter ablation resulted in termination during ablation at high dyssynchrony regions in 7 (41%) patients. In another 4 (24%) patients, transient organization was observed. In 6 (35%) there was no clear effect. Long-term follow-up showed 65% AF freedom at 1 year and 22% at 2 years. Conclusions Local electrical dyssynchrony provides a reasonable estimator of regional AF complexity defined as the number of fibrillatory waves. Additionally, it points to regions of dynamical instability related with action potential alternans. However, despite those characteristics, its utility in guiding catheter ablation of AF is limited suggesting other factors are responsible for AF persistence.


Europace | 2018

Image integration into 3-dimensional-electro-anatomical mapping system facilitates safe ablation of ventricular arrhythmias originating from the aortic root and its vicinity

Mario Jularic; Ruken Özge Akbulak; Benjamin Schäffer; Julia Moser; Jana Nuehrich; Christian G. Meyer; Christian Eickholt; Stephan Willems; Boris A. Hoffmann

Aims During ablation in the vicinity of the coronary arteries establishing a safe distance from the catheter tip to the relevant vessels is mandatory and usually assessed by fluoroscopy alone. The aim of the study was to investigate the feasibility of an image integration module (IIM) for continuous monitoring of the distance of the ablation catheter tip to the main coronary arteries during ablation of ventricular arrhythmias (VA) originating in the sinus of valsalva (SOV) and the left ventricular summit part of which can be reached via the great cardiac vein (GCV). Methods and results Of 129 patients undergoing mapping for outflow tract arrhythmias from June 2014 till October 2015, a total of 39 patients (52.4 ± 18.1 years, 17 female) had a source of origin in the SOV or the left ventricular summit. Radiofrequency (RF) ablation was performed when a distance of at least 5 mm could be demonstrated with IIM. A safe distance in at least one angiographic plane could be demonstrated in all patients with a source of origin in the SOV, whereas this was not possible in 50% of patients with earliest activation in the summit area. However, using the IIM a safe position at an adjacent site within the GCV could be obtained in three of these cases and successful RF ablation performed safely without any complications. Ablation was successful in 100% of patients with an origin in the SOV, whereas VAs originating from the left ventricular summit could be abolished completely in only 60% of cases. Conclusion Image integration combining electroanatomical mapping and fluoroscopy allows assessment of the safety of a potential ablation site by continuous real-time monitoring of the spatial relations of the catheter tip to the coronary vessels prior to RF application. It aids ablation in anatomically complex regions like the SOV or the ventricular summit providing biplane angiograms merged into the three-dimensional electroanatomical map.


Pacing and Clinical Electrophysiology | 2017

Active Atrial Function and Atrial Scar Burden After Multiple Catheter Ablations of Persistent Atrial Fibrillation: ATRIAL FUNCTION AFTER MULTIPLE ABLATIONS

Jana Mareike Nührich; Anne Geisler; Daniel Steven; Boris A. Hoffmann; Benjamin Schäffer; Gunnar Lund; Christian Stehning; Ulf K Radunski; Arian Sultan; Michael Schwarzl Md; Gerhard Adam; Stephan Willems; Kai Muellerleile

Extensive and repeated substrate modification (SM) is frequently performed as an ablation strategy in persistent atrial fibrillation (persAF). The effect of these extended ablation strategies on atrial function has not been investigated sufficiently so far. The purpose was to assess atrial function by cardiac magnetic resonance (CMR) and its association with left atrial (LA) scar burden by electroanatomical voltage‐mapping after multiple persAF ablation procedures.

Collaboration


Dive into the Benjamin Schäffer's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Daniel Steven

Brigham and Women's Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jakob Lüker

Massachusetts Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Christian G. Meyer

Bernhard Nocht Institute for Tropical Medicine

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge