Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Benjamin Snyder is active.

Publication


Featured researches published by Benjamin Snyder.


Journal of Bone and Joint Surgery, American Volume | 2015

Radiostereometric Analysis Study of Tantalum Compared with Titanium Acetabular Cups and Highly Cross-Linked Compared with Conventional Liners in Young Patients Undergoing Total Hip Replacement

David C. Ayers; Meridith E. Greene; Benjamin Snyder; Michelle E. Aubin; Jacob M. Drew; Charles R. Bragdon

BACKGROUND Radiostereometric analysis provides highly precise measurements of component micromotion relative to the bone that is otherwise undetectable by routine radiographs. This study compared, at a minimum of five years following surgery, the micromotion of tantalum and titanium acetabular cups and femoral head penetration in highly cross-linked polyethylene liners and conventional (ultra-high molecular weight polyethylene) liners in active patients who had undergone total hip replacement. METHODS This institutional review board-approved prospective, randomized, blinded study involved forty-six patients. Patients were randomized into one of four cohorts according to both acetabular cup and polyethylene liner. Patients received either a cementless cup with a titanium mesh surface or a tantalum trabecular surface and either a highly cross-linked polyethylene liner or an ultra-high molecular weight polyethylene liner. Radiostereometric analysis examinations and Short Form-36 Physical Component Summary, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), University of California Los Angeles (UCLA) activity, and Harris hip scores were obtained preoperatively, postoperatively, at six months, and annually thereafter. RESULTS All patients had significant improvement (p < 0.05) in Short Form-36 Physical Component Summary, WOMAC, UCLA activity, and Harris hip scores postoperatively. On radiostereometric analysis examination, highly cross-linked polyethylene liners showed significantly less median femoral head penetration at five years (p < 0.05). Steady-state wear rates from one year to five years were 0.04 mm per year for ultra-high molecular weight polyethylene liners and 0.004 mm per year for highly cross-linked polyethylene liners. At the five-year follow-up, the median migration (and standard error) was 0.05 ± 0.20 mm proximally for titanium cups and 0.21 ± 0.05 mm for tantalum cups. CONCLUSIONS In this young population who had undergone total hip replacement, radiostereometric analysis showed significantly less femoral head penetration in the highly cross-linked polyethylene liners compared with that in the conventional ultra-high molecular weight polyethylene liners. Penetration rates were one order of magnitude less in highly cross-linked polyethylene liners compared with ultra-high molecular weight polyethylene liners. There was no significant difference in proximal migration between the tantalum and titanium acetabular cups through the five-year follow-up (p > 0.19).


Journal of Bone and Joint Surgery-british Volume | 2014

A PROSPECTIVE RANDOMISED COMPARISON OF PATIENT SPECIFIC INSTRUMENTS WITH STANDARD TKA INSTRUMENTATION

A. Porter; Benjamin Snyder; Patricia D. Franklin; David C. Ayers


Archive | 2014

Poor Pre-Operative Emotional Health Limits Gain in Function after Total Hip Replacement

Benjamin Snyder; Leslie R. Harrold; Timothy Boardman; Wenjun Li; Courtland Lewis; David C. Ayers; Patricia D. Franklin


Archive | 2014

Radiostereometric Analysis of Femoral Head Penetration in Cross-Linked Polyethylene in THR Patients

Christina Kane; Anthony Porter; Benjamin Snyder; Marie Walcott; Michelle E. Aubin; Jacob M. Drew; Meridith E. Greene; Henrik Malchau; Charles Bragdon; David C. Ayers


Archive | 2014

Stability of a Tapered Femoral Stem in Total Hip Arthroplasty using Radiostereometric Analysis

Christina Kane; Audrey Nebergall; Meridith E. Greene; Anthony Porter; Benjamin Snyder; Marie Walcott; Michelle E. Aubin; Jacob M. Drew; Peyton L. Hays; Mark S. Eskander; Henrik Malchau; Charles Bragdon; David C. Ayers


Archive | 2014

Radiostereometric Analysis of Tantalum vs. Titanium Acetabular Shells in Young THR Patients

Christina Kane; Anthony Porter; Benjamin Snyder; Marie Walcott; Michelle E. Aubin; Jacob M. Drew; Meridith E. Greene; Henrik Malchau; Charles Bragdon; David C. Ayers


Journal of Bone and Joint Surgery-british Volume | 2014

RSA EVALUATION OF A CEMENTLESS TAPERED FEMORAL STEM WITH CROSSLINKED VS. CONVENTIONAL LINERS AND TANTALUM VS. TITANIUM ACETABULAR SHELLS IN YOUNG, ACTIVE THR PATIENTS

David C. Ayers; Benjamin Snyder; A. Porter; Marie Walcott; Michelle E. Aubin; Jacob M. Drew; M. Greene; C. Bragdon


Archive | 2013

Clinical Profile and Disability Levels of Younger vs. Older TKR and THR Patients in a National Research Consortium

David C. Ayers; Leslie R. Harrold; Benjamin Snyder; Sharina D. Person; Patricia D. Franklin


Archive | 2013

Differences Between Women and Men Undergoing TKR and THR in a National Research Consortium

Leslie R. Harrold; Patricia D. Franklin; Wenjun Li; Courtland Lewis; Benjamin Snyder; Milagros C. Rosal; David C. Ayers


Archive | 2013

Pre-operative Emotional Health Affects Post-operative Patient Function but not Patient Satisfaction Following Primary Total Hip Arthroplasty

Benjamin Snyder; Wenyun Yang; Anthony Porter; Patricia D. Franklin; David C. Ayers

Collaboration


Dive into the Benjamin Snyder's collaboration.

Top Co-Authors

Avatar

David C. Ayers

University of Massachusetts Medical School

View shared research outputs
Top Co-Authors

Avatar

Patricia D. Franklin

University of Massachusetts Medical School

View shared research outputs
Top Co-Authors

Avatar

Jacob M. Drew

University of Massachusetts Medical School

View shared research outputs
Top Co-Authors

Avatar

Michelle E. Aubin

University of Massachusetts Medical School

View shared research outputs
Top Co-Authors

Avatar

Leslie R. Harrold

UMass Memorial Health Care

View shared research outputs
Top Co-Authors

Avatar

Marie Walcott

University of Massachusetts Medical School

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Wenjun Li

UMass Memorial Health Care

View shared research outputs
Top Co-Authors

Avatar

Charles Bragdon

Hospital for Special Surgery

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge