Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Benoit Wattellier is active.

Publication


Featured researches published by Benoit Wattellier.


Optics Express | 2009

Quadriwave lateral shearing interferometry for quantitative phase microscopy of living cells

Pierre Bon; Guillaume Maucort; Benoit Wattellier; Serge Monneret

Phase imaging with a high-resolution wavefront sensor is considered. This is based on a quadriwave lateral shearing interferometer mounted on a non-modified transmission white-light microscope. The measurement technology is explained both in the scope of wave optics and geometrical optics in order to discuss its implementation on a conventional microscope. In particular we consider the effect of a non spatially coherent source on the phase-image signal-to-noise ratio. Precise measurements of the phase-shift introduced by microscopic beads or giant unilamellar vesicles validate the principle and show the accuracy of the methods. Diffraction limited images of living COS-7 cells are then presented, with a particular focus on the membrane and organelle dynamics.


Optics Letters | 2005

Wave-front reconstruction from multidirectional phase derivatives generated by multilateral shearing interferometers.

Sabrina Velghe; Jérôme Primot; Nicolas Guérineau; Mathieu Cohen; Benoit Wattellier

To increase the accuracy of wave-front evaluation, we propose to exploit the natural capability of multiple lateral shearing interferometers to measure simultaneously more than two orthogonal phase derivatives. We also describe a method, based on Fourier-transform analysis, that uses this multiple information to reconstruct the wave-front under study.


Nuclear Fusion | 2004

An overview of LLNL high-energy short-pulse technology for advanced radiography of laser fusion experiments

C. P. J. Barty; M.H. Key; J.A. Britten; R. Beach; G. Beer; C. Brown; S. Bryan; John A. Caird; T. Carlson; John K. Crane; Jay W. Dawson; Alvin C. Erlandson; D. N. Fittinghoff; Mark Hermann; C. Hoaglan; A. Iyer; L. Jones; Igor Jovanovic; Aleksey M. Komashko; O. L. Landen; Zhi M. Liao; William A. Molander; S. Mitchell; E. I. Moses; Norman D. Nielsen; H.-H. Nguyen; J. Nissen; Stephen A. Payne; Deanna M. Pennington; L. Risinger

The technical challenges and motivations for high-energy, short-pulse generation with the National Ignition Facility (NIF) and possibly other large-scale Nd : glass lasers are reviewed. High-energy short-pulse generation (multi-kilojoule, picosecond pulses) will be possible via the adaptation of chirped pulse amplification laser techniques on NIF. Development of metre-scale, high-efficiency, high-damage-threshold final optics is a key technical challenge. In addition, deployment of high energy petawatt (HEPW) pulses on NIF is constrained by existing laser infrastructure and requires new, compact compressor designs and short-pulse, fibre-based, seed-laser systems. The key motivations for HEPW pulses on NIF is briefly outlined and includes high-energy, x-ray radiography, proton beam radiography, proton isochoric heating and tests of the fast ignitor concept for inertial confinement fusion.


Proceedings of SPIE | 2004

Large flattened-mode optical fiber for reduction of nonlinear effects in optical fiber lasers

Jay W. Dawson; Raymond J. Beach; Igor Jovanovic; Benoit Wattellier; Zhi M. Liao; Stephen A. Payne; C. P. J. Barty

We have developed and demonstrated a large flattened mode (LFM) optical fiber, which raises the threshold for non-linear interactions in the fiber core by a factor of 2.5 over conventional large mode area fiber amplifiers. The LFM fiber works by incorporating a raised index ring around the outer edge of the fiber core, which serves to flatten the fundamental fiber mode from a Bessel function to a top hat function. This increases the effective area of the core intersected by the mode by a factor of 2.5 without increasing the physical size of the core. This is because the core is uniformly illuminated by the LFM mode rather than having most of the light confined to the center of the core. We present experimental and theoretical results relating to this fiber and its design.


Applied Optics | 2012

Noniterative boundary-artifact-free wavefront reconstruction from its derivatives

Pierre Bon; Serge Monneret; Benoit Wattellier

Wavefront sensors are usually based on measuring the wavefront derivatives. The most commonly used approach to quantitatively reconstruct the wavefront uses discrete Fourier transform, which leads to artifacts when phase objects are located at the image borders. We propose here a simple approach to avoid these artifacts based on the duplication and antisymmetrization of the derivatives data, in the derivative direction, before integration. This approach completely erases the border effects by creating continuity and differentiability at the edge of the image. We finally compare this corrected approach to the literature on model images and quantitative phase images of biological microscopic samples, and discuss the effects of the artifacts on the particular application of dry mass measurements.


Review of Scientific Instruments | 2004

Precision short-pulse damage test station utilizing optical parametric chirped-pulse amplification

Igor Jovanovic; Curtis G. Brown; Benoit Wattellier; Norman D. Nielsen; William A. Molander; Brent C. Stuart; Deanna M. Pennington; C. P. J. Barty

The next generation of high-energy petawatt (HEPW)-class lasers will utilize multilayer dielectric diffraction gratings for pulse compression, due to their high efficiency and high damage threshold for picosecond pulses. The peak power of HEPW lasers will be determined by the aperture and damage threshold of the final dielectric grating in the pulse compressor and final focusing optics. We have developed a short-pulse damage test station for accurate determination of the damage threshold of the optics used on future HEPW lasers. Our damage test station is based on a highly stable, high-beam-quality optical parametric chirped-pulse amplifier (OPCPA) operating at 1053 nm at a repetition rate of 10 Hz. We present the design of our OPCPA system pumped by a commercial Q-switched pump laser and the results of the full system characterization. Initial short-pulse damage experiments in the far field using our system have been performed.


Optics Letters | 2006

Piston measurement by quadriwave lateral shearing interferometry

Soazic Mousset; Claude Rouyer; Gabrielle Marre; Nathalie Blanchot; S. Montant; Benoit Wattellier

We present what is to our knowledge a new method for measuring the relative piston between two independent beams separated by a physical gap, typical of petawatt facilities. The feasibility of this measurement, based on quadriwave lateral shearing interferometry, has been demonstrated experimentally: piston has been measured with accuracy and sensitivity better than 50 nm.


Journal of Biomedical Optics | 2012

Optical detection and measurement of living cell morphometric features with single-shot quantitative phase microscopy

Pierre Bon; Julien Savatier; Marine Merlin; Benoit Wattellier; Serge Monneret

We present a quadriwave lateral shearing interferometer used as a wavefront sensor and mounted on a commercial non-modified transmission white-light microscope as a quantitative phase imaging technique. The setup is designed to simultaneously make measurements with both quantitative transmission phase and fluorescence modes: phase enables enhanced contrasted visualization of the cell structure including intracellular organelles, while fluorescence allows a complete and precise identification of each component. After the characterization of the phase measurement reliability and sensitivity on calibrated samples, we use these two imaging modes to measure the characteristic optical path difference between subcellular elements (mitochondria, actin fibers, and vesicles) and cell medium, and demonstrate that phase-only information should be sufficient to identify some organelles without any labeling, like lysosomes. Proof of principle results show that the technique could be used either as a qualitative tool for the control of cells before an experiment, or for quantitative studies on morphology, behavior, and dynamics of cells or cellular components.


Optics Express | 2015

Quantitative retardance imaging of biological samples using quadriwave lateral shearing interferometry

Sherazade Aknoun; Pierre Bon; Julien Savatier; Benoit Wattellier; Serge Monneret

We describe a new technique based on the use of a high-resolution quadri-wave lateral shearing interferometer to perform quantitative linear retardance and birefringence measurements on biological samples. The system combines quantitative phase images with varying polarization excitation to create retardance images. This technique is compatible with living samples and gives information about the local retardance and structure of their anisotropic components. We applied our approach to collagen fibers leading to a birefringence value of (3.4 ± 0.3) · 10(-3) and to living cells, showing that cytoskeleton can be imaged label-free.


Optics Express | 2014

Enhanced 3D spatial resolution in quantitative phase microscopy using spatially incoherent illumination

Pierre Bon; Sherazade Aknoun; Serge Monneret; Benoit Wattellier

We describe the use of spatially incoherent illumination to make quantitative phase imaging of a semi-transparent sample, even out of the paraxial approximation. The image volume electromagnetic field is collected by scanning the image planes with a quadriwave lateral shearing interferometer, while the sample is spatially incoherently illuminated. In comparison to coherent quantitative phase measurements, incoherent illumination enriches the 3D collected spatial frequencies leading to 3D resolution increase (up to a factor 2). The image contrast loss introduced by the incoherent illumination is simulated and used to compensate the measurements. This restores the quantitative value of phase and intensity. Experimental contrast loss compensation and 3D resolution increase is presented using polystyrene and TiO(2) micro-beads. Our approach will be useful to make diffraction tomography reconstruction with a simplified setup.

Collaboration


Dive into the Benoit Wattellier's collaboration.

Top Co-Authors

Avatar

Serge Monneret

Aix-Marseille University

View shared research outputs
Top Co-Authors

Avatar

Pierre Bon

Centre national de la recherche scientifique

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Sabrina Velghe

Office National d'Études et de Recherches Aérospatiales

View shared research outputs
Top Co-Authors

Avatar

C. P. J. Barty

Lawrence Livermore National Laboratory

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jérôme Primot

Office National d'Études et de Recherches Aérospatiales

View shared research outputs
Top Co-Authors

Avatar

Nicolas Guérineau

Office National d'Études et de Recherches Aérospatiales

View shared research outputs
Researchain Logo
Decentralizing Knowledge