Bernd Koos
University of Tübingen
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Bernd Koos.
Journal of Orofacial Orthopedics-fortschritte Der Kieferorthopadie | 2010
Bernd Koos; Arnim Godt; Christine Schille; Gernot Göz
AbstractBackground and Objective:In practice, analysis of occlusionnis reduced to depicting it with color-marking foils. Precisenanalysis that incorporates time resolution and plots the distributionnof forces within the occlusion is not possible in theneveryday clinical situation with the usual methods. T-Scan®nIII is a computer-assisted dental occlusion analyzer that depictsnocclusion by means of pressure-sensitive foils. The aimnof our study was to test the accuracy and reliability of thisnmethod.Subjects and Methods:The study population comprised 42nsubjects (23 male and 19 female, aged 20–30, median age 26nyears). The measurements were performed using the TScan® III from Tekscan Inc., South Boston, MA, USA. Sixnrecordings with two foils were made for each subject and antotal of 30 masticatory cycles were registered. Statisticalnanalysis referred to the method’s measurement accuracynand reliability, as well as the influence of changing the foilnand repositioning the T-Scan® III during the repeated measurements.Results:The percentage distribution of forces per toothnranged from 0 to 41%. The mean measurement per toothnwas 6.9% of the maximum total force exerted. The measurementnerror was 1%, the 1.96-fold measurement error calculatednaccording to Bland & Altman (accuracy) was 2% andnthe 2.77-fold measurement error (reliability) was 2.8%. Neithernchanging the foil nor the repeated measuring had anynstatistically significant influences on the measured value.Conclusion:The measuring technique studied is superior tonthe usual methods, particularly with regard to force analysisnper tooth. The level of accuracy is acceptable and no interferencenarising from change of foil or repeated measuringnwas detected. The method presented in this study thereforenenhances routine diagnostics with marking foils. A combinationnof this method with marking foils would be ideal becausenthe pressure-sensitive foils in this system do not producenany contact markings intraorally. This combinationnenables the contacts depicted on the computer to be assignednintraorally with even greater precision.ZusammenfassungHintergrund und Ziel:Die Analyse der Okklusion ist in dernPraxis auf die Abbildung mit farbig markierenden Foliennreduziert. Eine präzise zeitlich auflösende und die aufbauendenKraftverteilung darstellende Analyse ist mit den üblichennMethoden im klinischen Alltag nicht möglich. EinnMessverfahren, das computerunterstützt mit drucksensitivennFolien die Okklusion abbildet, ist das T-Scan®-III.nZiel unserer Untersuchung war es, Messgenauigkeit undnReliabilität dieser Methode zu prüfen.Probanden und Methodik:Die Studienpopulation bildetenn42 Probanden (23 männlich und 19 weiblich, 20–30 Jahrenalt, Median 26 Jahre). Die Messungen wurden mit dem TScan® III der Firma Tekscan Inc., South Boston, MA, USA,ndurchgeführt. Bei jedem Probanden wurden insgesamtnsechs Messaufzeichnungen mit zwei Folien und insgesamtn30 Kauzyklen aufgezeichnet. Die statistische Auswertungnanalysierte die Messgenauigkeit und Reliabilität der Methodensowie den Einfluss des Folienwechsels und der Repositionierungndes T-Scan®-III während der Wiederholungsmessungen.Ergebnisse:Die prozentuale Kraftverteilung pro Zahn variiertenvon 0 bis 41%. Der mittlere Messwert pro Zahn betrugn6,9% der maximal entwickelten Gesamtkraft. DernMessfehler betrug 1%, der nach Bland & Altman berechneten1,96fache Messfehler (Messgenauigkeit) betrug 2%nund der 2,77fache Messfehler (Reliabilität) betrug 2,8%. Esnwurden keine statistisch signifikanten Einflüsse am Messwertndurch den Folienwechsel oder die WiederholungsmessungnfestgestelltSchlussfolgerung:Das überprüfte Messverfahren ist, insbesonderenaufgrund der Kraftanalyse pro Zahn, den üblichennMethoden überlegen. Die Messgenauigkeit ist akzeptabelnund störende Einflüsse durch Folienwechsel oder wiederholtenMessungen konnten nicht nachgewiesen werden. Dasnvorgestellte Verfahren stellt daher eine Ergänzung zur Routinediagnostiknmit markierenden Folien dar. Ideal ist einenKombination dieses Verfahrens mit markierenden Folien,nda die drucksensitiven Folien des Messsystems keine Markierungennder Kontaktpunkte intraoral erzeugen. Durchneine Kombination sind die im Computer dargestellten Kontaktennoch präziser intraoral zuzuordnen.
Journal of Orofacial Orthopedics-fortschritte Der Kieferorthopadie | 2013
Bernd Koos; N. Tzaribachev; S. Bott; R. Ciesielski; Arnim Godt
IntroductionJuvenile idiopathic arthritis is the most common disease in pediatric rheumatology. It is characterized by chronically progressive joint destruction. The temporomandibular joints (TMJs) are involved in up to 87% of patients and may take an asymptomatic course in 69% of cases. Other than contrast-enhanced magnetic resonance imaging (MRI), there are no reliable screening symptoms or non-invasive procedures available to diagnose the inflammation in its acute form. The goal of this study was to establish an imaging-based classification system for TMJ erosion via MRI and cone-beam computed tomography (CBCT) in an effort to improve indication-specific treatment approaches and to facilitate the comparison of findings.Materials and methodsA total of 46xa0patients were included. Contrast-enhanced MRI and CBCT images obtained during treatment by pediatric rheumatologists and orthodontists were available from 23xa0patients with juvenile idiopathic arthritis. We devised a classification system combining the findings of both imaging techniques based on this patient sample in comparison with CBCT findings from an age- and gender-matched group of 23xa0non-arthritis patients, taking into consideration the available literature and administration of contrast medium.ResultsOur cohort of 46xa0patients comprised 60% female and 40% male patients with a mean age of 14xa0years, providing a total of 92xa0TMJs for evaluation. We were able to apply the findings efficiently and conveniently to this classification system with no relevant interobserver differences. Mild structural abnormalities were noted in 21% of TMJs in the control group, whereas 83% of TMJs in the arthritis group exhibited severe anomalies, including cases of extreme destruction. Age and gender did not affect the degree of destruction significantly.ConclusionThis is the first classification system to link CBCT and MRI with the use of contrast medium. Contrast-enhanced MRI is an internationally recognized technique that permits acute inflammation to be unequivocally diagnosed. Although structural erosion of the TMJs in our arthritis group was generally severe and significant, we were surprised to observe some cases that were clinically asymptomatic.ZusammenfassungEinleitungDie juvenile idiopathische Arthritis (JIA) ist die häufigste Erkrankung in der Kinderrheumatologie. Im Krankheitsverlauf imponiert die chronisch progrediente Gelenkdestruktion mit Kiefergelenkbeteiligung bei bis zu 87% aller Patienten, die in 69% der Fälle asymptomatisch verlaufen kann. Es gibt weder zuverlässige Screeningsymptome noch nichtinvasive Verfahren zur Diagnose der akuten Entzündung. Diese ist mittels kontrastmittelgestützter Magnetresonanztomographie (KM-MRT) möglich. Ziel dieser Untersuchung ist die Klassifikation und Darstellung der Kiefergelenkerosion in MRT und digitaler Volumentomographie (DVT). Die Klassifikation soll Therapieindikation und Befundvergleich verbessern.Material und MethodeBei den eingeschlossenen 46 Patienten lagen von 23 kinderrheumatologisch und kieferorthopädisch behandelten JIA-Patienten behandlungsbedingt KM-MRT- und DVT-Aufnahmen vor. Unter Berücksichtigung der zur Verfügung stehenden Literatur und der Kontrastmittelgabe wurde eine beide Verfahren verknüpfende Klassifikation erstellt und anhand der vorliegenden Patienten, verglichen mit einer Kontrollgruppe von 23 Patienten ohne JIA, am DVT mit angepasster Alters- und Geschlechtsstruktur überprüft.ErgebnisseInsgesamt wurden 92 Gelenke von 46 Patienten untersucht, (w:m=40:60%; Altersdurchschnitt14 Jahre). Die Befunde waren eindeutig, praktikabel und effizient in die Klassifikation einzuordnen, relevante Unterschiede zwischen den Untersuchern traten nicht auf. In der Kontrollgruppe waren 21% der Gelenke strukturell leicht auffällig, in der Rheumagruppe imponierten 83% strukturell stark veränderte Gelenke (mit zum Teil hochgradiger Zerstörung). Alter und Geschlecht übten keinen statistischen Einfluss auf den Zerstörungsgrad aus.SchlussfolgerungenBislang veröffentlichte Klassifikationen haben DVT und KM-MRT nicht miteinander verknüpft. Die KM-gestützte-MRT-Aufnahme ermöglicht die eindeutige Diagnose „akute Entzündung“ und ist international anerkannt. Signifikant war die generelle, starke strukturelle Erosion der Kiefergelenke in der Rheumagruppe, auffälligerweise zum Teil ohne klinische Symptomatik.
Angle Orthodontist | 2011
Arnim Godt; Bernd Koos; Hanno Hagen; Gernot Göz
OBJECTIVEnTo investigate the upper airways for anteroposterior width against different growth patterns and for alterations during various Class II treatments.nnnMATERIALS AND METHODSnCephalograms from three treatment groups (headgear, activator, and bite-jumping appliance) were evaluated by a single investigator at baseline and at the end of orthodontic treatment. Cephalograms were used to determine upper airway width at different levels in the anteroposterior plane. Patients in the headgear group were additionally divided into six subsets on the basis of y-axis values to assess the influence of different growth patterns.nnnRESULTSnSmall increases in pharyngeal width were noted at all vertical level segments, both at baseline and during orthodontic treatments. No significant differences in these small increases were noted across various treatment modalities and growth patterns.nnnCONCLUSIONnUpper airway changes did not significantly vary with the different treatment modalities investigated in the present study. Nevertheless, reductions in pharyngeal width potentially triggering or exacerbating obstructive sleep apnea syndrome (OSAS) are always possible in the headgear phase.
Journal of Orofacial Orthopedics-fortschritte Der Kieferorthopadie | 2013
Angela Schmidt; Robert Ciesielski; Wolfgang Orthuber; Bernd Koos
ObjectivesThe goal of this work was to conduct a survey of oral health-related quality of life (OHRQoL) among skeletal malocclusion patients who had undergone orthodontic treatment combined with orthognathic surgery.Patients and methodsThe study included 28xa0patients who had undergone orthodontic therapy combined with orthognathic surgery (surgical repositioning osteotomy) to treat skeletal malocclusion. OHRQoL was assessed based on a 14-item German version of the Oral Health Impact Profile (OHIP-G14) and an additional questionnaire developed by the authors to evaluate aspects of quality of life specific to skeletal malocclusion patients.ResultsThe mean OHIP-G14 score demonstrates that the malocclusion patients have a lower OHRQoL than the general population. The information collected via our skeletal malocclusion questionnaire correlates with the patients’ perceived esthetic and functional outcomes of treatment as well as their psychological state and social interactions. Satisfaction with treatment outcomes and improved social interactions correlated with high OHRQoL scores. High OHRQoL scores significantly correlated with enhanced well-being and the intensification of social contacts.ConclusionOur skeletal malocclusion questionnaire provides useful additional information on specific aspects of skeletal malocclusion patients, mapping in a detailed fashion aspects of function, esthetics, psychological condition, and social interactions. OHIP-G14 scores correlated negatively with OHRQoL.ZusammenfassungZielZiel der Untersuchung war die Erhebung der mundgesundheitsbezogenen Lebensqualität (MLQ) aus Patientensicht bei kombiniert kieferorthopädisch-kieferchirurgisch therapierten Dysgnathiepatienten.Patienten und MethodikIn die Studie eingeschlossen wurden 28 Patienten nach abgeschlossener kombinierter kieferorthopädischer-kieferchirurgischer Dysgnathiebehandlung mittels operativer Umstellungsosteotomie. Die MLQ wurde anhand des OHIP-G14-Fragebogen erhoben, zusätzlich wurde ein von den Autoren entwickelter Evaluationsbogen zur Lebensqualität von Dysgnathiepatienten eingesetzt.ErgebnisseDer OHIP-G14-Mittelwert aller Patienten belegte eine schlechtere MLQ der Dysgnathiepatienten gegenüber der Allgemeinbevölkerung. Der Dysgnathie-Zusatzbogen korrelierte mit subjektiver Bewertung der ästhetischen und funktionellen Ergebnisse der Therapie, psychischer Verfassung der Patienten und ihren sozialen Interaktionen. Zufriedenheit mit dem Behandlungsergebnis und Verbesserung der sozialen Interaktionen korrelierte mit einer hohen MLQ. Eine hohe MLQ korrelierte signifikant mit einer Steigerung des subjektiven Wohlbefindens und einer Intensivierung der sozialen Kontakte.SchlussfolgerungenDer Dysgnathie-Zusatzbogen als sinnvolle Ergänzung bei der Evaluation spezifischer Besonderheiten von Dysgnathiepatienten bildete differenziert die Bereiche Funktion, Ästhetik, Psyche und soziale Interaktionen ab. Die Ergebnisse des OHIP-G14 korrelierten negativ mit der MLQ.
Journal of Orofacial Orthopedics-fortschritte Der Kieferorthopadie | 2012
Bernd Koos; Johanna Britta-Marie Höller; Christine Schille; Armin Godt
ObjectiveUntil now, the exact timing of force buildup and the distribution of contact points during occlusion have not been analyzed in sufficient detail. Investigations published so far have tended to focus on force curve measurements on single teeth or on a static point in time in the entire dental arch. The objective of this study was to describe precisely and analyze force relations in the dental arch over the course of time and in correlation with their antagonistic dental contact points via instrumental occlusal analysis (T-Scanxa0III; Cumdente, Tübingen, Germany).Materials and methodsWe assessed 190 masticatory cycles of 38 subjects with 5 repetitions each, analyzing the first 0.15xa0s after the first recorded antagonistic tooth contact. Recording took place in 0.01-s increments. This measurement method’s precision was positively evaluated in previous studies.ResultsAt t1, 44% of the subjects occluded first in the molar area; surprisingly, while another 40% occluded first on the anterior teeth. Simultaneous initial antagonistic tooth contact occurred in the lateral and anterior teeth in only 16%. At t10 (after 0.1xa0s), the predominant contact was in the molar and premolar region. The relative masticatory force distribution also changed over time, starting with a relatively large initial force on the central incisors toward the posterior at the recording conclusion. In the lateral comparison (right/left), the force relationships likewise changed over time (t2 on the left 42.6% of the relative masticatory force, 57.4% on the right). By t10, this lateral difference was significantly reduced (47.4% on the left, 52.6% on the right). The lateral difference, thus, decreased by 9.6% from t2 to t10.ConclusionOur data contradict the theory of a simultaneous or even increase in occlusion as the norm. Our detailed analysis of occlusion over time demonstrates that it is the central incisors that usually tend to come into initial contact, perhaps as the result of a guiding function. Over time, the force distribution shifts to the posterior.ZusammenfassungZielDer genaue zeitliche Ablauf des Kraftaufbaus und der Kontaktpunktverteilung in der Okklusion wurden bislang noch nicht ausreichend detailliert analysiert. Vorliegende Untersuchungen beziehen sich primär auf Kraftverlaufsmessungen an einzelnen Zähnen oder auf einen statischen Zeitpunkt im gesamten Zahnbogen. Ziel dieser Untersuchung ist die genaue Darstellung und Analyse der Kraftverhältnisse im Zahnbogen in zeitlicher Verlaufsbetrachtung und in Korrelation zu ihren antagonistischen Kontaktpunkten mittels Instrumenteller Okklusionsanalyse (T-Scanxa0III, Cumdente, Tübingen).Material und MethodikAusgewertet wurden 190 Kauzyklen von 38 Probanden mit je 5 Wiederholungen. Ausgewertet wurden die ersten 0,15 Sekunden nach dem ersten registrierten Antagonistenkontakt. Die Aufzeichnung erfolgte in 0,01-s-Schritten. Die Präzision des Messverfahrens wurde in vorangegangenen Untersuchungen bereits positiv evaluiert.ErgebnisseZum Zeitpunkt t1 okkludierten 44% der Probanden zuerst im Molarenbereich, überraschend belasteten weitere 40% zuerst im Frontzahnbereich. Nur bei 16% fand initial im Seiten- und Frontzahngebiet ein gleichzeitiger Antagonistenkontakt statt. Bei t10 (nach 0,1xa0s) lag der überwiegende Kontakt im Molaren- und Prämolarenbereich. Auch die relative Kaukraftverteilung veränderte sich im Zeitverlauf von initial relativ großer Kraft auf den mittleren Inzisiven zum Verlaufsende hin nach posterior. Ebenso im Seitenvergleich (rechts/links) veränderten sich die Kraftverhältnisse mit dem zeitlichen Verlauf (t2 links 42,6% der relativen Kaukraft, rechts 57,4%). Zum Zeitpunkt t10 war diese Seitendifferenz signifikant vermindert (links 47,4%, rechts 52,6%). Die Seitendifferenz verringerte sich somit von t2 zu t10 um 9,6%.SchlussfolgerungDie Auswertung unserer gemessenen Daten widerspricht der Theorie einer sich gleichzeitig und gleichmäßig aufbauenden Okklusion als Norm. Die detaillierte zeitliche Verlaufsbetrachtung der Okklusion zeigt die Tendenz, dass initial am häufigsten die mittleren Inzisiven, möglicherweise im Sinne einer Führungsfunktion, in Kontakt treten. Im späteren Verlauf findet eine Verlagerung der Kraftverteilung nach posterior statt.
Journal of Orofacial Orthopedics-fortschritte Der Kieferorthopadie | 2012
Till Edward Bechtold; T.G. Göz; Edgar Schaupp; Bernd Koos; Arnim Godt; S. Reinert; Mirjam Berneburg
AimsThree-dimensional (3D) integration of a maxillary model into a facial model has only been possible by a complex procedure using face bow transfer after taking impressions of certain maxillary and facial parts. In this study, we aimed to develop a method for integrating a scanned maxillary model into a scan-realized facial model.Material and methodsA total of 19 patients with the medical indication for cone-beam computed tomography (CBCT) and orthodontic treatment were included in this study. Facial and maxillary scans were also taken. The construction of the integrated surface model required 10xa0steps. This integration procedure was evaluated by taking ten 3D dentofacial linear segment measurements in the integrated scan and the CBCT. These results were analyzed using descriptive statistics.ResultsAll measurements demonstrated good intra-individual reliability. We observed almost perfect congruence between integrated scan and CBCT in vertical distances, while the sagittal measurements revealed more, yet clinically acceptable, deviations possibly caused by different error sources in either of the two methods.ConclusionThis new method is suitable for generating 3D integrated surface-scan models which can be used for growth and therapy control studies in orthodontics and other disciplines in the dentofacial fields. Since this method does not require ionizing radiation, it is highly recommendable as an application for children and adolescent patients.ZusammenfassungZieleDie dreidimensionale Integration eines Kiefermodells in ein Gesichtsmodell war bislang nur aufwendig durch Gesichtsbogenübertragung nach Abdrucknahme von Kiefer- und Gesichtsanteilen möglich. Aufgabe der vorliegenden Studie war, eine Methode zu entwickeln, welche die Übertragung der mit dem Scanner erfassten Kiefermodelle in das Scan-registrierte Gesichtsmodell ermöglicht.Material und MethodikVon 19 Patienten wurden aus medizinischer Indikation ein DVT, kieferorthopädische Anfangsunterlagen sowie Gesichts- und Kieferscans angefertigt. Die Erstellung des integrierten Oberflächenmodells erfolgte in zehn Teilschritten. Zur Evaluation der Integration wurden zehn dreidimensionale dentofaziale Messungen am integrierten Oberflächenmodell und am DVT durchgeführt und mittels deskriptiver Statistik miteinander verglichen.ErgebnisseBei guter intraindividueller Reliabilität aller Messungen wiesen die vertikalen Distanzmessungen eine nahezu perfekte Übereinstimmung von integriertem Oberflächenmodell und DVT auf; die sagittalen Distanzmessungen zeigten mehr, jedoch klinisch akzeptable Abweichungen zwischen den beiden bildgebenden Verfahren, die allerdings von unterschiedlichen Fehlerquellen beider Methoden stammen können.SchlussfolgerungDie vorgestellte Methode ist geeignet, ein integriertes Oberflächenmodell herzustellen, das ohne ionisierende Strahlen für Wachstums- und Therapiestudien in der Zahn-, Mund- und Kieferheilkunde eingesetzt werden kann. Daher ist sie besonders für den Einsatz bei Kindern und jugendlichen Patienten geeignet.
European Journal of Orthodontics | 2013
Bernd Koos; Hansjörg Horn; Edgar Schaupp; Detlef Axmann; Mirjam Berneburg
Precise knowledge of lip and tongue movements is limited. Conventional investigative methods do not allow for their precise representation and analysis. In the present study, electromagnetic articulography (EMA) was used to define normal values for lip movements based on consonant-vowel-consonant (CVC) sequences and for tongue movements based on vowel-consonant-vowel (VCV) sequences. The study population included 25 volunteers (11 males and 14 females) with a median age of 26 (23 to 29) years. An EMA unit was used to conduct the measurements. For this purpose, the volunteers repeated a number of VCV and CVC text sequences 10 times each during two different body positions (upright and relaxed). Statistical analysis (including Bland and Altmans measurement error, non-parametric Wilcoxon rank score testing, and analysis of variance) of distance and time variables resulted in a small measurement error. There was no effect of different body positions on measurement error. Gender was found to have a significant effect on the values measured (67 versus 17 per cent of variables related to distances in CVC versus VCV sequences and 38 versus 75 per cent of variables related to intervals in CVC versus VCV sequences). This finding did not, however, hold true for any of the other parameters investigated as potential influencing factors. EMA is capable of providing valuable information about lip and tongue movements and any pathological dysfunctions involved.
Angle Orthodontist | 2013
Arnim Godt; Till Edward Bechtold; Edgar Schaupp; Claudia Zeyher; Bernd Koos; Eva Baas; Mirjam Berneburg
OBJECTIVEnTo clarify, by three-dimensional (3D) facial scans, if 4- to 6-year-old children with intraoral sagittal discrepancies and open-bite occlusion show differences in facial morphology when compared to children without anomalies.nnnMATERIALS AND METHODSnScans of 290 children presenting with occlusal abnormalities were compared to 1772 face scans of age-matched individuals photographed with a faceSCAN II® 3D data acquisition system. From these, three study groups were formed comprising 188 children with distal occlusion/increased overjet (Class II), 37 with mesial occlusion/inverse overjet (Class III), and 65 with open-bite occlusion. These groups were evaluated by age and gender for each group compared to the control individuals.nnnRESULTSnThe Class II group showed statistically significant reduced dimensions of head width, upper face width, and midface length. In addition, the mean values for mouth width and lip thickness were higher, and their upper lips were located more anteriorly than in the control group. The Class III group exhibited more markedly retruded upper lips. The facial profile of female 5-year-old Class III patients was significantly more concave. Patients in the open-bite group showed reduced upper lip length, with differences only being statistically significant in male 4-year-olds.nnnCONCLUSIONnDental Class II with increased overjet and dental Class III with decreased overjet influence soft tissue morphology and are represented on 3D facial scans.
European Journal of Radiology | 2018
Emilio J. Inarejos Clemente; Mirkamal Tolend; Thitiporn Junhasavasdikul; Jennifer Stimec; Nikolay Tzaribachev; Bernd Koos; Lynn Spiegel; Rahim Moineddin; Andrea S. Doria
OBJECTIVEnTemporomandibular joints (TMJs) frequently develop silent inflammatory and osteochondral changes in children with juvenile idiopathic arthritis. Data-driven recommendations for TMJ imaging protocol are needed to reduce measurement error and scanning time. This study compares the impact of different protocols, imaging coils, and magnet strength on the reliability of image assessment and the subjective quality of images.nnnMATERIALS AND METHODSnThree groups of bilateral TMJ MR studies were retrospectively collected from two institutions, including 24 1.5T and 19 3.0T studies using dedicated TMJ surface coils, and 23 1.5T studies with head coil. Post-contrast sequences were re-compiled from the full protocol to create minimum protocol studies for the three groups. Two radiologists and two non-radiologists first scored the three minimum protocol images according to pre-specified definitions, then scored the full protocol images. Minimum-to-full protocol agreement, inter-reader agreement, and subjective item visibility scores were assessed.nnnRESULTSnWith dedicated TMJ dual surface coils, minimum-vs-full protocol agreement was moderate to good (0.5-0.8 intraclass correlation coefficients or kappa) for most items, and was not influenced by the magnet strength. Inter-reader reliability was more significantly influenced by the imaging coil and readers training background than by protocol length or magnet strength differences. Sagittal and coronal planes weighted on PD, T2 Fat Suppressed and T1 Fat Suppressed -postcontrast adequately visualized all the different features, whereas the axial plane was more limited to visualizing synovium.nnnCONCLUSIONnInter-reader reliability and qualitative measure of image quality improved more consistently with the coil offering the higher resolution, rather than increased magnet strength.
Journal of Orofacial Orthopedics-fortschritte Der Kieferorthopadie | 2018
Hannah Finke; Bernd Koos; Helge Fischer-Brandies; Martha Es-Souni
PurposeMiniscrews are an important choice for orthodontic anchorage. Yet reports on failures do exist, and attempts have been made to elucidate the causes. Clinical outcomes may be compromised not only by the mechanical implications of miniscrew design and the location of anchorage but also by poor biocompatibility. Hence, this study deals with the surface roughness and elemental composition of miniscrews and how these properties may affect the in vitro biocompatibility of four commercially available miniscrews.MethodsMost of the currently available miniscrews are made of TiAl6V4, an alloy widely considered to be biocompatible. The samples tested in this study included four similarly dimensioned TiAl6V4 products from different manufacturers: tomas® by Dentaurum, OrthoEasy® by Forestadent®, Dual Top™ by Jeil Medical/Promedia, and LOMAS by Mondeal®. The surface properties of these products were characterized by scanning electron microscopy (SEM) and energy-dispersive X‑ray spectroscopy (EDX). Cytotoxicity was assessed by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) and agar overlay assays according to ISOxa010993-5.ResultsThe miniscrew products were found to show variations in surface-finish quality pertaining to topography and chemical composition, with the latter departing slightly from the manufacturers’ specifications. MTT assays yielded rates of cell culture viability in excess of 90%, and agar overlay assays did not reveal decoloration beyond the specimen outlines in any of the experimental groups tested.ConclusionsThe four miniscrew products exhibited some minor, but statistically significant, differences in microtopography, alloy composition, and biological inertness. Cytotoxicity testing revealed that all four products should be considered non-cytotoxic, thus, ruling out poor biocompatibility as axa0cause of miniscrew failure.ZusammenfassungZielMinischrauben stellen eine wichtige Verankerungsmethode in der Kieferorthopädie dar. Trotz intensiver Forschung konnten die Gründe für Lockerung und Verluste nicht abschließend geklärt werden. Als wesentliche klinische Parameter gelten mechanische Faktoren, wie Implantatdesign, aber auch der Insertionsort und mögliche Unterschiede in der Biokompatibilität. Ziel der vorliegenden Studie war der Vergleich von 4xa0kommerziell erhältlichen Miniimplantatprodukten in Bezug auf Oberflächenbeschaffenheit und deren mögliche Auswirkungen auf die In-vitro-Biokompatibilität.Material und MethodenDie meisten derzeit verwendeten kieferorthopädischen Miniimplantate sind aus der allgemein als biokompatibel eingeschätzten Legierung TiAl6V4 hergestellt. In der vorliegenden Studie wurden 4xa0Produkte ähnlicher Größe getestet: tomas® (Dentaurum), OrthoEasy® (Forestadent®), Dual Top™ (Jeil Medical/Promedia), und LOMAS (Mondeal®). Die Oberflächenbeschaffenheit wurde mittels Rasterelektronenmikroskopie (SEM) und energiedispersiver Röntgenspektroskopie (EDX) beurteilt. Zur Zytotoxizitätsmessung wurden MTT(3‑(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazoliumbromid)- und Agar-Overlay-Tests in Anlehnung an die ISO-Normxa010933-5 durchgeführt.ErgebnisseDie Miniimplantate zeigten deutliche Unterschiede in der Oberflächenbeschaffenheit, sowohl in Bezug auf die Rauheit als auch auf die Legierungszusammensetzung mit leichten Abweichungen zu den Herstellerangaben. Die Ergebnisse der Zytotoxizitätstests mit einer Zellviabilität von >90% im MTT-Test und einer Entfärbungszone im Agar-Overlay-Test, die den Umriss der Probekörper nicht überschritt, zeigten keine Hinweise auf zytotoxische Effekte der untersuchten Produkte.SchlussfolgerungAlle 4xa0Miniimplantate zeigten leichte, aber statistisch signifikante Unterschiede in der Oberflächenbeschaffenheit und -zusammensetzung sowie in den biologischen Auswirkungen im Zytotoxizitätstest. Aufgrund der minimalen Abweichungen sind dennoch alle 4xa0Produkte als biokompatibel einzustufen, und es zeigten sich keine Hinweise auf mögliche biologische Ursachen von klinischen Verlusten.