Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Bettina Petersen is active.

Publication


Featured researches published by Bettina Petersen.


Diabetes Care | 2011

Structured Self-Monitoring of Blood Glucose Significantly Reduces A1C Levels in Poorly Controlled, Noninsulin-Treated Type 2 Diabetes: Results from the Structured Testing Program study

William H. Polonsky; Lawrence Fisher; Charles H. Schikman; Deborah Hinnen; Christopher G. Parkin; Zhihong Jelsovsky; Bettina Petersen; Matthias Schweitzer; Robin Wagner

OBJECTIVE To assess the effectiveness of structured blood glucose testing in poorly controlled, noninsulin-treated type 2 diabetes. RESEARCH DESIGN AND METHODS This 12-month, prospective, cluster-randomized, multicenter study recruited 483 poorly controlled (A1C ≥7.5%), insulin-naïve type 2 diabetic subjects from 34 primary care practices in the U.S. Practices were randomized to an active control group (ACG) with enhanced usual care or a structured testing group (STG) with enhanced usual care and at least quarterly use of structured self-monitoring of blood glucose (SMBG). STG patients and physicians were trained to use a paper tool to collect/interpret 7-point glucose profiles over 3 consecutive days. The primary end point was A1C level measured at 12 months. RESULTS The 12-month intent-to-treat analysis (ACG, n = 227; STG, n = 256) showed significantly greater reductions in mean (SE) A1C in the STG compared with the ACG: −1.2% (0.09) vs. −0.9% (0.10); Δ = −0.3%; P = 0.04. Per protocol analysis (ACG, n = 161; STG, n = 130) showed even greater mean (SE) A1C reductions in the STG compared with the ACG: −1.3% (0.11) vs. −0.8% (0.11); Δ = −0.5%; P < 0.003. Significantly more STG patients received a treatment change recommendation at the month 1 visit compared with ACG patients, regardless of the patient’s initial baseline A1C level: 179 (75.5%) vs. 61 (28.0%); <0.0001. Both STG and ACG patients displayed significant (P < 0.0001) improvements in general well-being (GWB). CONCLUSIONS Appropriate use of structured SMBG significantly improves glycemic control and facilitates more timely/aggressive treatment changes in noninsulin-treated type 2 diabetes without decreasing GWB.


Diabetes Care | 2013

Use of an Insulin Bolus Advisor Improves Glycemic Control in Multiple Daily Insulin Injection (MDI) Therapy Patients With Suboptimal Glycemic Control: First results from the ABACUS trial

Ralph Ziegler; D. A. Cavan; Iain Cranston; Katharine Barnard; Jacqueline Ryder; Claudia Vogel; Christopher G. Parkin; Walter Koehler; Iris Vesper; Bettina Petersen; Matthias Schweitzer; Robin Wagner

OBJECTIVE Use of automated bolus advisors is associated with improved glycemic control in patients treated with insulin pump therapy. We conducted a study to assess the impact of using an insulin bolus advisor embedded in a blood glucose (BG) meter on glycemic control and treatment satisfaction in patients treated with multiple daily insulin injection (MDI) therapy. The study goal was to achieve >0.5% A1C reduction in most patients. RESEARCH DESIGN AND METHODS This was a 26-week, prospective, randomized, controlled, multinational study that enrolled 218 MDI-treated patients with poorly controlled diabetes (202 with type 1 diabetes, 16 with type 2 diabetes) who were 18 years of age or older. Participants had mean baseline A1C of 8.9% (SD, 1.2 [74 mmol/mol]), mean age of 42.4 years (SD, 14.0), mean BMI of 26.5 kg/m2 (SD, 4.2), and mean diabetes duration of 17.7 years (SD, 11.1). Control group (CNL) patients used a standard BG meter and manual bolus calculation; intervention group (EXP) patients used the Accu-Chek Aviva Expert meter with an integrated bolus advisor to calculate insulin dosages. Glucose data were downloaded and used for therapy parameter adjustments in both groups. RESULTS A total of 193 patients (CNL, n = 93; EXP, n = 100) completed the study. Significantly more EXP than CNL patients achieved >0.5% A1C reduction (56.0% vs. 34.4%; P < 0.01). Improvement in treatment satisfaction (Diabetes Treatment Satisfaction Questionnaire scale) was significantly greater in EXP patients (11.4 [SD, 6.0] vs. 9.0 [SD, 6.3]; P < 0.01). Percentage of BG values <50 mg/dL was <2% in both groups during the study. CONCLUSIONS Use of an automated bolus advisor resulted in improved glycemic control and treatment satisfaction without increasing severe hypoglycemia.


Diabetes Research and Clinical Practice | 2012

The impact of structured blood glucose testing on attitudes toward self-management among poorly controlled, insulin-naïve patients with type 2 diabetes

Lawrence Fisher; William H. Polonsky; Christopher G. Parkin; Zhihong Jelsovsky; Bettina Petersen; Robin Wagner

INTRODUCTION Patients with T2DM often view self-monitoring of blood glucose (SMBG) as burdensome and pointless, which may affect their broader attitudes toward diabetes management. We examined how a structured SMBG protocol influenced diabetes self-efficacy and autonomous motivation over time, and linked these to changes in glycemic control. MATERIALS AND METHODS The Structured Testing Program (STeP) is a 12-month, two-arm, cluster-randomized trial that assessed the efficacy of structured SMBG in 483 insulin-naïve T2DM patients. Measures included: Confidence in Diabetes Self-Care for Type 2 patients (CIDS-T2), Diabetes-related Autonomous Motivation (DRAM), self-management behaviors and HbA1c. RESULTS Intent-to-treat (ITT) and per-protocol (PP) analyses showed significant increases in CIDS-T2 scores over time (main effects p<0.0001). PP analysis showed significant between-group differences (p<0.05), with adherent STG patients displaying greater CIDS-T2 improvement than ACG patients. PP analyses showed main and between-group effects in DRAM with similar findings. Changes in CIDS-T2 were related to HbA1c changes over time; no self-management variable mediated this relationship. CIDS-T2 and HbA1c displayed a significant time-concordant relationship. DISCUSSION Structured SMBG leads to significant increases in self-confidence and autonomous motivation associated with diabetes self-management. Changes in self-confidence are linked to changes in glycemic control and share a time-concordant relationship.


BMC Family Practice | 2012

Automated bolus advisor control and usability study (ABACUS): does use of an insulin bolus advisor improve glycaemic control in patients failing multiple daily insulin injection (MDI) therapy? [NCT01460446]

D. A. Cavan; Ralph Ziegler; Iain Cranston; Katharine Barnard; Jacqueline Ryder; Claudia Vogel; Christopher G. Parkin; Walter Koehler; Iris Vesper; Bettina Petersen; Robin Wagner

BackgroundPeople with T1DM and insulin-treated T2DM often do not follow and/or adjust their insulin regimens as needed. Key contributors to treatment non-adherence are fear of hypoglycaemia, difficulty and lack of self-efficacy associated with insulin dose determination. Because manual calculation of insulin boluses is both complex and time consuming, people may rely on empirical estimates, which can result in persistent hypoglycaemia and/or hyperglycaemia. Use of automated bolus advisors (BA) has been shown to help insulin pump users to more accurately meet prandial insulin dosage requirements, improve postprandial glycaemic excursions, and achieve optimal glycaemic control with an increased time within optimal range. Use of a BA containing an early algorithm based on sliding scales for insulin dosing has also been shown to improve HbA1c levels in people treated with multiple daily insulin injections (MDI). We designed a study to determine if use of an automated BA can improve clinical and psychosocial outcomes in people treated with MDI.Methods/designThe Automated Bolus Advisor Control and Usability Study (ABACUS) is a 6-month, prospective, randomised, multi-centre, multi-national trial to determine if automated BA use improves glycaemic control as measured by a change in HbA1c in people using MDI with elevated HbA1c levels (#62;7.5%). A total of 226 T1DM and T2DM participants will be recruited. Anticipated attrition of 20% will yield a sample size of 90 participants, which will provide #62;80% power to detect a mean difference of 0.5%, with SD of 0.9%, using a one-sided 5% t-test, with 5% significance level. Other measures of glycaemic control, self-care behaviours and psychosocial issues will also be assessed.DiscussionIt is critical that healthcare providers utilise available technologies that both facilitate effective glucose management and address concerns about safety and lifestyle. Automated BAs may help people using MDI to manage their diabetes more effectively and minimise the risk of long-term diabetes related complications. Findings from a recent study suggest that BA use positively addresses both safety and lifestyle concerns; however, randomised trials are needed to confirm these perceptions and determine whether bolus advisor use improves clinical outcomes. Our study is designed to make these assessments.Trial registrationNCT01460446


Pediatric Diabetes | 2016

Frequent use of an automated bolus advisor improves glycemic control in pediatric patients treated with insulin pump therapy: results of the Bolus Advisor Benefit Evaluation (BABE) study

Ralph Ziegler; Christen Rees; Nehle Jacobs; Christopher G. Parkin; Maureen Lyden; Bettina Petersen; Robin Wagner

The relationship between frequency and sustained bolus advisor (BA) use and glycemic improvement has not been well characterized in pediatric populations.


Journal of diabetes science and technology | 2010

Multicenter user evaluation of ACCU-CHEK® Combo, an integrated system for continuous subcutaneous insulin infusion.

David Kerr; Roel P.L.M Hoogma; Andreas Buhr; Bettina Petersen; Fred E.M.G Storms

Background: The aim of this study was to evaluate a newly developed system for insulin delivery incorporating a multifunctional blood glucose meter and a remotely controlled insulin pump (ACCU-CHEK® Combo system) in established pump users with type 1 diabetes. The technology was assessed both from device performance and subject usability perspectives. Method: A multicenter, prospective, single group study was carried out in five centers in the Netherlands and four centers in the United Kingdom for more than 6 months. The study was divided into two phases: Phase 1 (4 weeks) for device validation purposes and phase 2 (22 weeks) to observe the impact of the system on metabolic control, patient satisfaction [using the Diabetes Treatment Satisfaction Questionnaire (DTSQ)] and device safety. Results: Eighty subjects completed the planned study period. There were no unexpected device errors. Treatment satisfaction was high at baseline and further increased to study end (DTSQ change version: Sum score, 10.6 ± 7.2; scale score range, −18 to +18, p < 0.0001). Hemoglobin A1c improved continuously over time, from 7.9% (±0.9%) to 7.7% (±0.8%) at month 3 (p < 0.001) and 7.6% (±0.8%) at month 6 (p < 0.0001). The frequency of severe hypoglycemia was 0.08 per patient years. There was no case of ketoacidosis. Conclusions: The new system was evaluated by experienced continuous subcutaneous insulin infusion users as safe in daily practice and associated with favorable treatment satisfaction and a modest improvement in glycemic control.


Journal of diabetes science and technology | 2017

Randomized Cross-Over Study Comparing Two Infusion Sets for CSII in Daily Life

Guido Freckmann; Stephan Arndt; Albrecht Fießelmann; Gerhard Klausmann; Kristina Pralle; Thomas Künsting; Bettina Petersen

Background: Continuous subcutaneous insulin infusion (CSII) therapy is a valuable option especially for people with type 1 diabetes. Although insulin infusion sets (IIS) are essential components of most insulin pump systems, only few studies have been conducted on their performance and safety. In this study 2 IIS with soft cannulas were compared. Methods: In an open-label, randomized, crossover, multicenter 8-week study 80 type 1 diabetic subjects on CSII (20-74 years, mean 46.5 ± 12.9 years, 58.8% male) were enrolled to evaluate the use of 2 IIS. The Accu-Chek® FlexLink Plus (FL Plus) and the Accu-Chek® FlexLink infusion set (FL) were used 4 weeks each under real-life conditions at home. All patients had to record details about every IIS change in a diary. Insertion-related pain was assessed by means of a visual analogue scale (VAS). Results: The mean pain noted during insertion was similar for both IIS (VAS 6.1 ± 6.4 mm for the FL Plus and 5.8 ± 6.3 mm for the FL, P = .92). 20.0% of the 895 IIS changes with FL Plus and 16.0% of the 854 with FL were unplanned. During the 4243 patient days of the study, 13 patients had adverse events. Among these, 2 serious adverse events occurred. Both serious events and 1 nonserious adverse event were considered as related to the IIS. Of the patients, 18.7% had kinked cannulas. Most patients were satisfied with both IIS. Conclusion: Both IIS are safe and effective. The 2 IIS did not differ from each other with respect to pain observed during insertion.


Journal of diabetes science and technology | 2018

Open Source Closed-Loop Insulin Delivery Systems: A Clash of Cultures or Merging of Diverse Approaches?:

Katharine Barnard; Ralph Ziegler; David C. Klonoff; Katarina Braune; Bettina Petersen; Til Rendschmidt; Daniel Finan; Aaron J. Kowalski; Lutz Heinemann

Biomedical outcomes for people with diabetes remain suboptimal for many. Psychosocial care in diabetes does not fare any better. “Artificial pancreas” (also known as “closed-loop” and “automated insulin delivery”) systems present a promising therapeutic option for people with diabetes (PWD)—simultaneously improving glycemic outcomes, reducing the burden of self-management, and improving health-related quality of life. In recent years there has emerged a growing movement of PWD innovators rallying behind the mantra #WeAreNotWaiting, developing “do-it-yourself artificial pancreas systems (DIY APS).” Self-reported results by DIY APS users show improved metabolic outcomes such as impressive stability of glucose profiles, significant reduction of A1c, and more time within their glycemic target range. However, the benefits remain unclear for the broader population of PWD beyond these highly engaged, highly tech-savvy users willing and able to engage in the demands of building and maintaining their DIY APS. We discuss the challenges faced by key stakeholder groups in terms of potential collaboration and open debate of these challenges.


Diabetes Technology & Therapeutics | 2011

A structured self-monitoring of blood glucose approach in type 2 diabetes encourages more frequent, intensive, and effective physician interventions: results from the STeP study.

William H. Polonsky; Lawrence Fisher; Charles H. Schikman; Deborah Hinnen; Christopher G. Parkin; Zhihong Jelsovsky; Matthias Axel-Schweitzer; Bettina Petersen; Robin Wagner


Diabetes Technology & Therapeutics | 2007

Comparison of Continuous Blood Glucose Measurement with Conventional Documentation of Hypoglycemia in Patients with Type 2 Diabetes on Multiple Daily Insulin Injection Therapy

Reinhard Zick; Bettina Petersen; Mario Richter; Cornelia Haug

Collaboration


Dive into the Bettina Petersen's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Charles H. Schikman

NorthShore University HealthSystem

View shared research outputs
Top Co-Authors

Avatar

Deborah Hinnen

University of Colorado Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

D. A. Cavan

Royal Bournemouth Hospital

View shared research outputs
Top Co-Authors

Avatar

Iain Cranston

Queen Alexandra Hospital

View shared research outputs
Researchain Logo
Decentralizing Knowledge