The Journal of Nuclear Medicine | 2009
F van der Have; Brendan Vastenhouw; Ruud M. Ramakers; Woutjan Branderhorst; J.O. Krah; Changguo Ji; S.G. Staelens; Freek J. Beekman
We present a new rodent SPECT system (U-SPECT-II) that enables molecular imaging of murine organs down to resolutions of less than half a millimeter and high-resolution total-body imaging. Methods: The U-SPECT-II is based on a triangular stationary detector set-up, an XYZ stage that moves the animal during scanning, and interchangeable cylindric collimators (each containing 75 pinhole apertures) for both mouse and rat imaging. A novel graphical user interface incorporating preselection of the field of view with the aid of optical images of the animal focuses the pinholes to the area of interest, thereby maximizing sensitivity for the task at hand. Images are obtained from list-mode data using statistical reconstruction that takes system blurring into account to increase resolution. Results: For 99mTc, resolutions determined with capillary phantoms were smaller than 0.35 and 0.45 mm using the mouse collimator with 0.35- and 0.6-mm pinholes, respectively, and less than 0.8 mm using the rat collimator with 1.0-mm pinholes. Peak geometric sensitivity is 0.07% and 0.18% for the mouse collimator with 0.35- and 0.6-mm pinholes, respectively, and 0.09% for the rat collimator. Resolution with 111In, compared with that with 99mTc, was barely degraded, and resolution with 125I was degraded by about 10%, with some additional distortion. In vivo, kidney, tumor, and bone images illustrated that U-SPECT-II could be used for novel applications in the study of dynamic biologic systems and radiopharmaceuticals at the suborgan level. Conclusion: Images and movies obtained with U-SPECT-II provide high-resolution radiomolecule visualization in rodents. Discrimination of molecule concentrations between adjacent volumes of about 0.04 μL in mice and 0.5 μL in rats with U-SPECT-II is readily possible.
Physics in Medicine and Biology | 2004
Freek J. Beekman; Brendan Vastenhouw
Exciting new SPECT systems can be created by combining pinhole imaging with compact high-resolution gamma cameras. These new systems are able to solve the problem of the limited sensitivity-resolution trade-off that hampers contemporary small animal SPECT. The design presented here (U-SPECT-III) uses a set of detectors placed in a polygonal configuration and a cylindrical collimator that contains 135 pinholes arranged in nine rings. Each ring contains 15 gold pinhole apertures that focus on the centre of the cylinder. A non-overlapping projection is acquired via each pinhole. Consequently, when a mouse brain is placed in the central field-of-view, each voxel in the cerebrum can be observed via 130 to 135 different pinholes simultaneously. A method for high-resolution scintillation detection is described that eliminates the depth-of-interaction problem encountered with pinhole cameras, and is expected to provide intrinsic detector resolutions better than 150 microm. By means of simulations U-SPECT-III is compared to a simulated dual pinhole SPECT (DP-SPECT) system with a pixelated array consisting of 2.0 x 2.0 mm NaI crystals. Analytic calculations indicate that the proposed U-SPECT-III system yields an almost four times higher linear and about sixty times higher volumetric system resolution than DP-SPECT, when the systems are compared at matching system sensitivity. In addition, it should be possible to achieve a 15 up to 30 times higher sensitivity with U-SPECT-III when the systems are compared at equal resolution. Simulated images of a digital mouse-brain phantom show much more detail with U-SPECT-III than with DP-SPECT. In a resolution phantom, 0.3 mm diameter cold rods are clearly visible with U-SPECT-III, whereas with DP-SPECT the smallest visible rods are about 0.6-0.8 mm. Furthermore, with U-SPECT-III, the image deformations outside the central plane of reconstruction that hamper conventional pinhole SPECT are strongly suppressed. Simulation results indicate that future pinhole SPECT systems are likely to bring about significant improvements in radio-molecular imaging of small animals.
Siam Review | 2005
Brendan Vastenhouw; Rob H. Bisseling
A new method is presented for distributing data in sparse matrix-vector multiplication. The method is two-dimensional, tries to minimize the true communication volume, and also tries to spread the computation and communication work evenly over the processors. The method starts with a recursive bipartitioning of the sparse matrix, each time splitting a rectangular matrix into two parts with a nearly equal number of nonzeros. The communication volume caused by the split is minimized. After the matrix partitioning, the input and output vectors are partitioned with the objective of minimizing the maximum communication volume per processor. Experimental results of our implementation, Mondriaan, for a set of sparse test matrices show a reduction in communication volume compared to one-dimensional methods, and in general a good balance in the communication work. Experimental timings of an actual parallel sparse matrix-vector multiplication on an SGI Origin 3800 computer show that a sufficiently large reduction in communication volume leads to savings in execution time.
Physics in Medicine and Biology | 2010
Woutjan Branderhorst; Brendan Vastenhouw; Freek J. Beekman
Block-iterative image reconstruction methods, such as ordered subset expectation maximization (OSEM), are commonly used to accelerate image reconstruction. In OSEM, the speed-up factor over maximum likelihood expectation maximization (MLEM) is approximately equal to the number of subsets in which the projection data are divided. Traditionally, each subset consists of a couple of projection views, and the more subsets are used, the more the solution deviates from MLEM solutions. We found for multi-pinhole single photon emission computed tomography (SPECT) that even moderate acceleration factors in OSEM lead to inaccurate reconstructions. Therefore, we introduce pixel-based ordered subset expectation maximization (POSEM), which is based on an alternative subset choice. Pixels in each subset are spread out regularly over projections and are spatially separated as much as possible. We validated POSEM for data acquired with a focusing multi-pinhole SPECT system. Performance was compared with traditional OSEM and MLEM for a rat total body bone scan, a gated mouse myocardial perfusion scan and a Defrise phantom scan. We found that POSEM can be operated at acceleration factors that are often an order of magnitude higher than in traditional OSEM.
The Journal of Nuclear Medicine | 2013
Marlies C Goorden; Frans van der Have; Rob Kreuger; Ruud M. Ramakers; Brendan Vastenhouw; J. Peter H. Burbach; Jan Booij; Carla F. M. Molthoff; Freek J. Beekman
Today, PET and SPECT tracers cannot be imaged simultaneously at high resolutions but require 2 separate imaging systems. This paper introduces a Versatile Emission Computed Tomography system (VECTor) for radionuclides that enables simultaneous submillimeter imaging of single-photon and positron-emitting radiolabeled molecules. Methods: γ-photons produced both by electron–positron annihilation and by single-photon emitters are projected onto the same detectors by means of a novel cylindric high-energy collimator containing 162 narrow pinholes that are grouped in clusters. This collimator is placed in an existing SPECT system (U-SPECT-II) with 3 large-field-of-view γ-detectors. From the acquired projections, PET and SPECT images are obtained using statistical image reconstruction that corrects for energy-dependent system blurring. Results: For PET tracers, the tomographic resolution obtained with a Jaszczak hot rod phantom was less than 0.8 mm, and 0.5-mm resolution images of SPECT tracers were acquired simultaneously. SPECT images were barely degraded by the simultaneous presence of a PET tracer, even when the activity concentration of the PET tracer exceeded that of the SPECT tracer by up to a factor of 2.5. Furthermore, we simultaneously acquired fully registered 3- and 4-dimensional multiple functional images from living mice that, in the past, could be obtained only sequentially. Conclusion: High-resolution complementary information about tissue function contained in SPECT and PET tracer distributions can now be obtained simultaneously using a fully integrated imaging device. These combined unique capabilities pave the way for new perspectives in imaging the biologic systems of rodents.
European Journal of Nuclear Medicine and Molecular Imaging | 2011
Woutjan Branderhorst; Brendan Vastenhouw; Frans van der Have; Erwin L. A. Blezer; Wim K. Bleeker; Freek J. Beekman
PurposeSmall-animal single photon emission computed tomography (SPECT) with focused multi-pinhole collimation geometries allows scanning modes in which large amounts of photons can be collected from specific volumes of interest. Here we present new tools that improve targeted imaging of specific organs and tumours, and validate the effects of improved targeting of the pinhole focus.MethodsA SPECT system with 75 pinholes and stationary detectors was used (U-SPECT-II). An XYZ stage automatically translates the animal bed with a specific sequence in order to scan a selected volume of interest. Prior to stepping the animal through the collimator, integrated webcams acquire images of the animal. Using sliders, the user designates the desired volume to be scanned (e.g. a xenograft or specific organ) on these optical images. Optionally projections of an atlas are overlaid semiautomatically to locate specific organs. In order to assess the effects of more targeted imaging, scans of a resolution phantom and a mouse myocardial phantom, as well as in vivo mouse cardiac and tumour scans, were acquired with increased levels of targeting. Differences were evaluated in terms of count yield, hot rod visibility and contrast-to-noise ratio.ResultsBy restricting focused SPECT scans to a 1.13-ml resolution phantom, count yield was increased by a factor 3.6, and visibility of small structures was significantly enhanced. At equal noise levels, the small-lesion contrast measured in the myocardial phantom was increased by 42%. Noise in in vivo images of a tumour and the mouse heart was significantly reduced.ConclusionTargeted pinhole SPECT improves images and can be used to shorten scan times. Scan planning with optical cameras provides an effective tool to exploit this principle without the necessity for additional X-ray CT imaging.
European Journal of Nuclear Medicine and Molecular Imaging | 2010
Chao Wu; Frans van der Have; Brendan Vastenhouw; Rudi Dierckx; Anne M. J. Paans; Freek J. Beekman
PurposeIn pinhole SPECT, attenuation of the photon flux on trajectories between source and pinholes affects quantitative accuracy of reconstructed images. Previously we introduced iterative methods that compensate for image degrading effects of detector and pinhole blurring, pinhole sensitivity and scatter for multi-pinhole SPECT. The aim of this paper is (1) to investigate the accuracy of the Chang algorithm in rodents and (2) to present a practical Chang-based method using body outline contours obtained with optical cameras.MethodsHere we develop and experimentally validate a practical method for attenuation correction based on a Chang first-order method. This approach has the advantage that it is employed after, and therefore independently from, iterative reconstruction. Therefore, no new system matrix has to be calculated for each specific animal. Experiments with phantoms and animals were performed with a high-resolution focusing multi-pinhole SPECT system (U-SPECT-II, MILabs, The Netherlands). This SPECT system provides three additional optical camera images of the animal for each SPECT scan from which the animal contour can be estimated.ResultsPhantom experiments demonstrated that an average quantification error of –18.7% was reduced to –1.7% when both window-based scatter correction and Chang correction based on the body outline from optical images were applied. Without scatter and attenuation correction, quantification errors in a sacrificed rat containing sources with known activity ranged from –23.6 to –9.3%. These errors were reduced to values between –6.3 and +4.3% (with an average magnitude of 2.1%) after applying scatter and Chang attenuation correction.ConclusionWe conclude that the modified Chang correction based on body contour combined with window-based scatter correction is a practical method for obtaining small-animal SPECT images with high quantitative accuracy.
Molecular Psychiatry | 2007
Brendan Vastenhouw; F. van der Have; A.J.A. van der Linden; L von Oerthel; Jan Booij; J.P.H. Burbach; Marten P. Smidt; Freek J. Beekman
A pivotal question in neuropharmacology is how the function of neurotransmitter systems relates to psychiatric diseases. In experimental neuropharmacology, we have dreamt about a looking glass that would allow us to see neurotransmitter systems in action, and about animals that would faithfully serve us as models for human psychiatric disease. Analysis of animal models has been limited by the availability of methods to study in vivo neurotransmitter dynamics. Now, a single photon emission computed tomography system called U-SPECT can localize dopamine transporters in sub-compartments of the mouse brain during a range of points in time. Applied to the midbrain dopamine system of different models of disease, this will aid the understanding of dynamic processes of this neurotransmitter that underlie brain functions and human brain pathology.
The Journal of Nuclear Medicine | 2012
Pieter Vaissier; Marlies C Goorden; Brendan Vastenhouw; Frans van der Have; Ruud M. Ramakers; Freek J. Beekman
Small-animal SPECT systems with stationary detectors and focusing multiple pinholes can achieve excellent resolution–sensitivity trade-offs. These systems are able to perform fast total-body scans by shifting the animal bed through the collimator using an automated xyz stage. However, so far, a large number of highly overlapping central fields of view have been used, at the cost of overhead time needed for animal repositioning and long image reconstruction times due to high numbers of projection views. Methods: To improve temporal resolution and reduce image reconstruction time for such scans, we have developed and tested spiral trajectories (STs) of the animal bed requiring fewer steps. In addition, we tested multiplane trajectories (MPTs) of the animal bed, which is the standard acquisition method of the U-SPECT-II system that is used in this study. Neither MPTs nor STs require rotation of the animal. Computer simulations and physical phantom experiments were performed for a wide range of numbers of bed positions. Furthermore, we tested STs in vivo for fast dynamic mouse scans. Results: We found that STs require less than half the number of bed positions of MPTs to achieve sufficient sampling. The reduced number of bed positions made it possible to perform a dynamic total-body bone scan and a dynamic hepatobiliary scan with time resolutions of 60 s and 15 s, respectively. Conclusion: STs open up new possibilities for high throughput and fast dynamic radio-molecular imaging.
Physics in Medicine and Biology | 2011
Chao Wu; J. R. de Jong; H A Gratama van Andel; F van der Have; Brendan Vastenhouw; Peter Laverman; Otto C. Boerman; Rudi Dierckx; Freek J. Beekman
Attenuation of photon flux on trajectories between the source and pinhole apertures affects the quantitative accuracy of reconstructed single-photon emission computed tomography (SPECT) images. We propose a Chang-based non-uniform attenuation correction (NUA-CT) for small-animal SPECT/CT with focusing pinhole collimation, and compare the quantitative accuracy with uniform Chang correction based on (i) body outlines extracted from x-ray CT (UA-CT) and (ii) on hand drawn body contours on the images obtained with three integrated optical cameras (UA-BC). Measurements in phantoms and rats containing known activities of isotopes were conducted for evaluation. In (125)I, (201)Tl, (99m)Tc and (111)In phantom experiments, average relative errors comparing to the gold standards measured in a dose calibrator were reduced to 5.5%, 6.8%, 4.9% and 2.8%, respectively, with NUA-CT. In animal studies, these errors were 2.1%, 3.3%, 2.0% and 2.0%, respectively. Differences in accuracy on average between results of NUA-CT, UA-CT and UA-BC were less than 2.3% in phantom studies and 3.1% in animal studies except for (125)I (3.6% and 5.1%, respectively). All methods tested provide reasonable attenuation correction and result in high quantitative accuracy. NUA-CT shows superior accuracy except for (125)I, where other factors may have more impact on the quantitative accuracy than the selected attenuation correction.