Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Brian Hoang is active.

Publication


Featured researches published by Brian Hoang.


Optical Microlithography XVI | 2003

New concerns with the design of filters for the protection of lithography optics

Andrew J. Dallas; William Lefei Ding; Brian Hoang; Jon Dennis Joriman; Jonathan G. Parsons; Kevin Seguin

The optimal medium in which DUV resists are exposed is becoming increasingly under investigation by lithography tool manufacturers. These medium requirements have created even more design restrictions for effective filtration methods. Traditional airborne molecular contamination control in tracks and exposure tools has focused on the removal of weak bases that poison the resist. Newer concerns, including; the degradation of optics, changes in resist sensitivity, the index of refraction and the demands of tighter geometries, all contribute to the need for quantification and control of gas-phase contamination within exposure tools. As a result, filter manufacturers are required not only to remove a broader spectrum of contaminants (e.g. organic and acid gases), but to supply removal efficiency data, under a variety of conditions including; variable challenge concentrations, mixed stream contamination, humidity (dew points), flow rates, and temperatures. The paper will address these new concerns focusing on the efficiency effects of relative humidity for various contaminant streams using a variety of filter media. In addition, the removal of hydrophilic compounds such as ammonia and sulfur dioxide when drying an air stream will also be considered. This ongoing study has contributed to the design of a point-of-use air-shower filter used to protect lithography lenses. Preliminary field tests by a major manufacturer indicate that the removal of the specified bases, acids and total organics is below detection limits of <0.1 ppb.


Metrology, inspection, and process control for microlithography. Conference | 2006

An investigation of the removal of 1-methyl-2-pyrrolidinone (NMP)

Andrew J. Dallas; Lefei Ding; Jon Dennis Joriman; Brian Hoang; Kevin Seguin; Dustin Zastera

Molecular bases have long been known to be a problem in photolithographic applications using chemically amplified photoresists. Of these molecular bases, ammonia and 1-methyl-2-pyrrolidinone (NMP) have been studied in the most detail since chemical filtration of these contaminants is critical to the success of the photolithographic process. It has been well documented that ammonia is best removed through chemisorptive reactions using acid impregnated adsorbents or strong acid ion exchange resins. However, the mechanism(s) for the removal of NMP has not been investigated to any significant extent. There are several chemical filtration systems available that employ activated carbon, impregnated activated carbon, or ion exchange resins for the removal of NMP. This work investigates the removal of NMP using several different types of adsorbents and rationalizes the adsorption mechanism which is operative in each situation.


Metrology, Inspection, and Process Control for Microlithography XVIII | 2004

Are ambient SO2 levels a valid indicator of projected acid gas filter life

Andrew J. Dallas; Lefei Ding; Jon Dennis Joriman; Brian Hoang; Jonathan G. Parsons; Kevin Seguin

The requirement to extend existing lithography equipment working levels and life has required manufacturers and end users to extend their filtration requirements beyond airborne base gases. Due to the effect acid gases can have on optics, masks, reticles, steppers, wafers, and metrology tools, they have become a more important molecular airborne contaminate to remove from inside a fab. SO2 is known to be especially problematic within the cleanroom and exposure tool environment. However, a host of other molecular acids can also be found, some of which are present at considerably higher concentrations; the most prevalent of which are oxides of nitrogen, NOx. Although the removal of NOx contaminants is currently not considered to be as critical as SO2, its presence can have a significant impact on acid gas sensitive applications. Several of these applications are addressed in this work in order to point out that NOx contaminants do pose a problem, especially when considering the performance of acid gas chemical filters. More importantly, this preliminary work puts forth the recommendation that in addition to SO2, the concentration of other acid gases should be taken into account when acid gas chemical filter efficiency and life estimates are being made.


Advances in Patterning Materials and Processes XXXV | 2018

Improved airborne molecular contaminant filter performance for photolithography

Brian Hoang; Gerald Weineck; Joshua Lais

Airborne molecular contaminants continue to pose cost of ownership challenges in photolithography. Recent advances in understanding siloxane removal have led to the development of an innovative filtration configuration utilizing new media that works in concert to increase overall filter life for acids, bases and silicon containing organic contaminants. This paper examines accelerated testing results, for these state-of-the-art filtration assemblies versus legacy products, to demonstrate improved system performance. The state-of-the-art filtration assemblies have been evaluated in production semiconductor fabs and have shown favorable performance.


Metrology, inspection, and process control for microlithography. Conference | 2005

Removal of Low Concentrations of Acid Gases: Issues and Solutions

Andrew J. Dallas; Lefei Ding; Jeremy Exley; Jon Dennis Joriman; Brian Hoang; Jonathan G. Parsons; Kevin Seguin; Dustin Zastera

Part per billion concentrations of acid gases such as SOx and NOx have been detected in both high purity gases and CDA lines. These contaminants can have deleterious effects on a number of high purity applications such as the optics found in lithography equipment steppers, scanners, and inspection tools. In addition, acidic gases have also been shown to reduce the life of masks and reticles, decrease fuel cell output due to catalyst poisoning, and cause hard disk drive crashes due to surface contamination and corrosion. Consequently, acid gas control in these applications has become a critical part of the required filtration system. SOx concentrations are typically used as the baseline for acid gas filter exposure guidelines and performance testing. However, this approach has been shown to provide poor filter life predictions, which has been attributed to the presence of other acidic and organic contaminants that compete with SOx for the available adsorption sites. Equally important, the type of sorbents and methods used to control acid gases can significantly affect the ability to remove SOx. In this work we will compare the performance of various sorbents, structures, and methods for the removal of SOx and NOx.


Archive | 2002

Adsorption element and methods

Kevin Seguin; Steven Alan Carter; Andrew J. Dallas; Lefei Ding; Brian Hoang; Jon Dennis Joriman


Archive | 2004

Adsorptive filter element and methods

Lefei Ding; Daniel E. Adamek; Andrew J. Dallas; Brian Hoang; Jon Dennis Joriman; Kevin Seguin


Archive | 2013

Materials, methods, and devices for siloxane contaminant removal

Brian Hoang; Gerald Weineck; Karthik Viswanathan; Andrew J. Dallas


Archive | 2007

Method of Using Adsorptive Filter Element

Lefei Ding; Daniel E. Adamek; Andrew J. Dallas; Brian Hoang; Jon Dennis Joriman; Kevin Seguin


Archive | 2002

Element d'adsorption et procede associe

Kevin Seguin; Steven Alan Carter; Andrew J. Dallas; Lefei Ding; Brian Hoang; Jon Dennis Joriman

Collaboration


Dive into the Brian Hoang's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge