Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Brian S. Crow is active.

Publication


Featured researches published by Brian S. Crow.


Analytical Chemistry | 2014

Simultaneous measurement of tabun, sarin, soman, cyclosarin, VR, VX, and VM adducts to tyrosine in blood products by isotope dilution UHPLC-MS/MS.

Brian S. Crow; Brooke G. Pantazides; Jennifer Quiñones-González; Joshua W. Garton; Melissa D. Carter; Jonas W. Perez; Caroline Watson; Dennis J. Tomcik; Michael D. Crenshaw; Bobby N. Brewer; James R. Riches; Sarah J. Stubbs; Robert W. Read; Ronald A. Evans; Jerry D. Thomas; Thomas A. Blake; Rudolph C. Johnson

This work describes a new specific, sensitive, and rapid stable isotope dilution method for the simultaneous detection of the organophosphorus nerve agents (OPNAs) tabun (GA), sarin (GB), soman (GD), cyclosarin (GF), VR, VX, and VM adducts to tyrosine (Tyr). Serum, plasma, and lysed whole blood samples (50 μL) were prepared by protein precipitation followed by digestion with Pronase. Specific Tyr adducts were isolated from the digest by a single solid phase extraction (SPE) step, and the analytes were separated by reversed-phase ultra high performance liquid chromatography (UHPLC) gradient elution in less than 2 min. Detection was performed on a triple quadrupole tandem mass spectrometer using time-triggered selected reaction monitoring (SRM) in positive electrospray ionization (ESI) mode. The calibration range was characterized from 0.100-50.0 ng/mL for GB- and VR-Tyr and 0.250-50.0 ng/mL for GA-, GD-, GF-, and VX/VM-Tyr (R(2) ≥ 0.995). Inter- and intra-assay precision had coefficients of variation of ≤17 and ≤10%, respectively, and the measured concentration accuracies of spiked samples were within 15% of the targeted value for multiple spiking levels. The limit of detection was calculated to be 0.097, 0.027, 0.018, 0.074, 0.023, and 0.083 ng/mL for GA-, GB-, GD-, GF-, VR-, and VX/VM-Tyr, respectively. A convenience set of 96 serum samples with no known nerve agent exposure was screened and revealed no baseline values or potential interferences. This method provides a simple and highly specific diagnostic tool that may extend the time postevent that a confirmation of nerve agent exposure can be made with confidence.


Journal of Analytical Toxicology | 2014

An Enhanced Throughput Method for Quantification of Sulfur Mustard Adducts to Human Serum Albumin Via Isotope Dilution Tandem Mass Spectrometry

Tracy M. Andacht; Brooke G. Pantazides; Brian S. Crow; Alex Fidder; Daan Noort; Jerry D. Thomas; Thomas A. Blake; Rudolph C. Johnson

Here, we report an enhanced throughput method for the diagnosis of human exposure to sulfur mustard. A hydroxyethylthioethyl (HETE) ester-adducted tripeptide, produced by pronase digestion of human serum albumin, was selected as the quantitative exposure biomarker. Cibacron Blue enrichment was developed from an established cartridge method into a 96-well plate format, increasing throughput and ruggedness. This new method decreased sample volume 2.5-fold. Addition of a precipitation and solid-phase extraction concentration step increased the sensitivity of the method. With the conversion to a 96-well plate and optimization of chromatography, the method resulted in a 3-fold decrease in analysis time. Inclusion of a confirmation ion has increased specificity. The method was found to be linear between 0.050 and 50 µM sulfur mustard exposure with a precision for both quality control samples of ≤6.5% relative standard deviation and an accuracy of >96%. The limit of detection (3So) was calculated to be ∼0.0048 µM, an exposure value similar to that of the HETE-albumin adduct method first described by Noort and co-workers (Noort et al., 1999; Noort el al., 2004) which used protein precipitation to isolate albumin. A convenience set of 124 plasma samples from healthy unexposed individuals was analyzed using this method to assess background levels of exposure to sulfur mustard; no positive results were detected.


Journal of Mass Spectrometry | 2015

Quantitation of ortho-cresyl phosphate adducts to butyrylcholinesterase in human serum by immunomagnetic-UHPLC-MS/MS

Darryl Johnson; Melissa D. Carter; Brian S. Crow; Samantha L. Isenberg; Leigh Ann Graham; H. Akin Erol; Caroline M. Watson; Brooke G. Pantazides; Marcel J. van der Schans; J.P. Langenberg; Daan Noort; Thomas A. Blake; Jerry D. Thomas; Rudolph C. Johnson

Tri-ortho-cresyl phosphate (ToCP) is an anti-wear, flame retardant additive used in industrial lubricants, hydraulic fluids and gasoline. The neurotoxic effects of ToCP arise from the liver-activated metabolite 2-(o-cresyl)-4H-1,3,2-benzodioxaphosphoran-2-one (cresyl saligenin phosphate or CBDP), which inhibits esterase enzymes including butyrylcholinesterase (BChE). Following BChE adduction, CBDP undergoes hydrolysis to form the aged adduct ortho-cresyl phosphoserine (oCP-BChE), thus providing a biomarker of CBDP exposure. Previous studies have identified ToCP in aircraft cabin and cockpit air, but assessing human exposure has been hampered by the lack of a laboratory assay to confirm exposure. This work presents the development of an immunomagnetic-UHPLC-MS/MS method for the quantitation of unadducted BChE and the long-term CBDP biomarker, oCP-BChE, in human serum. The method has a reportable range from 2.0 ng/ml to 150 ng/ml, which is consistent with the sensitivity of methods used to detect organophosphorus nerve agent protein adducts. The assay demonstrated high intraday and interday accuracy (≥85%) and precision (RSD ≤ 15%) across the calibration range. The method was developed for future analyses of potential human exposure to CBDP. Analysis of human serum inhibited in vitro with CBDP demonstrated that the oCP-BChE adduct was stable for at least 72 h at 4, 22 and 37 °C. Compared to a previously reported assay, this method requires 75% less sample volume, reduces analysis time by a factor of 20 and demonstrates a threefold improvement in sensitivity. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.


Journal of Analytical Toxicology | 2016

Simultaneous Measurement of 3-Chlorotyrosine and 3,5-Dichlorotyrosine in Whole Blood, Serum and Plasma by Isotope Dilution HPLC–MS-MS

Brian S. Crow; Jennifer Quiñones-González; Brooke G. Pantazides; Jonas W. Perez; W. Rucks Winkeljohn; Joshua W. Garton; Jerry D. Thomas; Thomas A. Blake; Rudolph C. Johnson

Chlorine is a public health concern and potential threat due to its high reactivity, ease and scale of production, widespread industrial use, bulk transportation, massive stockpiles and history as a chemical weapon. This work describes a new, sensitive and rapid stable isotope dilution method for the retrospective detection and quantitation of two chlorine adducts. The biomarkers 3-chlorotyrosine (Cl-Tyr) and 3,5-dichlorotyrosine (Cl2-Tyr) were isolated from the pronase digest of chlorine exposed whole blood, serum or plasma by solid-phase extraction (SPE), separated by reversed-phase HPLC and detected by tandem mass spectrometry (MS-MS). The calibration range is 2.50-1,000 ng/mL (R2 ≥ 0.998) with a lowest reportable limit (LRL) of 2.50 ng/mL for both analytes, an accuracy of ≥93% and an LOD of 0.443 ng/mL for Cl-Tyr and 0.396 ng/mL for Cl2-Tyr. Inter- and intra-day precision of quality control samples had coefficients of variation of ≤10% and ≤7.0%, respectively. Blood and serum samples from 200 healthy individuals and 175 individuals with chronic inflammatory disease were analyzed using this method to assess background levels of chlorinated tyrosine adducts. Results from patients with no known inflammatory disease history (healthy) showed baseline levels of <LRL-4.26 ng/mL Cl-Tyr and <LRL Cl2-Tyr. Patients with inflammatory disease had baseline levels of <LRL-15.4 ng/mL Cl-Tyr and <LRL-5.22 ng/mL Cl2-Tyr. Blood exposed to 2.02 ppm chlorine gas for 15 min produced 941 ng/mL Cl-Tyr and 223 ng/mL Cl2-Tyr. This high-throughput method has been developed and analytically validated for the diagnosis of human exposure to chlorine.


Journal of Biomolecular Screening | 2014

Profiling Cholinesterase Adduction A High-Throughput Prioritization Method for Organophosphate Exposure Samples

Melissa D. Carter; Brian S. Crow; Brooke G. Pantazides; Caroline M. Watson; B. Rey deCastro; Jerry D. Thomas; Thomas A. Blake; Rudolph C. Johnson

A high-throughput prioritization method was developed for use with a validated confirmatory method detecting organophosphorus nerve agent exposure by immunomagnetic separation high-performance liquid chromatography tandem mass spectrometry. A ballistic gradient was incorporated into this analytical method to profile unadducted butyrylcholinesterase (BChE) in clinical samples. With Zhang et al.’s Z′ factor of 0.88 ± 0.01 (SD) of control analytes and Z factor of 0.25 ± 0.06 (SD) of serum samples, the assay is rated an “excellent assay” for the synthetic peptide controls used and a “double assay” when used to prioritize clinical samples. Hits, defined as samples containing BChE Ser-198 adducts or no BChE present, were analyzed in a confirmatory method for identification and quantitation of the BChE adduct, if present. The ability to prioritize samples by highest exposure for confirmatory analysis is of particular importance in an exposure to cholinesterase inhibitors such as organophosphorus nerve agents, in which a large number of clinical samples may be collected. In an initial blind screen, 67 of 70 samples were accurately identified, giving an assay accuracy of 96%, and it yielded no false-negatives. The method is the first to provide a high-throughput prioritization assay for profiling adduction of Ser-198 BChE in clinical samples.


Proceedings of SPIE--the International Society for Optical Engineering | 2016

Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

Elizabeth I. Hamelin; Thomas A. Blake; Jonas W. Perez; Brian S. Crow; Rebecca L. Shaner; Rebecca M. Coleman; Rudolph C. Johnson

Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.


Journal of Analytical Toxicology | 2016

Quantification of Hydrazine in Human Urine by HPLC–MS-MS

Samantha L. Isenberg; Melissa D. Carter; Brian S. Crow; Leigh Ann Graham; Darryl Johnson; Nick Beninato; Kandace Steele; Jerry D. Thomas; Rudolph C. Johnson

Currently used on F-16 fighter jets and some space shuttles, hydrazine could be released at toxic levels to humans as a result of an accidental leakage or spill. Lower-level exposures occur in industrial workers or as a result of the use of some pharmaceuticals. A method was developed for the quantitation of hydrazine in human urine and can be extended by dilution with water to cover at least six orders of magnitude, allowing measurement at all clinically significant levels of potential exposure. Urine samples were processed by isotope dilution, filtered, derivatized and then quantified by HPLC-MS-MS. The analytical response ratio was linearly proportional to the urine concentration of hydrazine from 0.0493 to 12.3 ng/mL, with an average correlation coefficientRof 0.9985. Inter-run accuracy for 21 runs, expressed as percent relative error (% RE), was ≤14%, and the corresponding precision, expressed as percent relative standard deviation (% RSD), was ≤15%. Because this method can provide a quantitative measurement of clinical samples over six orders of magnitude, it can be used to monitor trace amounts of hydrazine exposure as well as industrial and environmental exposure levels.


Journal of Chemical Education | 2017

Supplemental Learning in the Laboratory: An Innovative Approach for Evaluating Knowledge and Method Transfer

Melissa D. Carter; Sarah S. Pierce; Albert D. Dukes; Rebecca Brown; Brian S. Crow; Rebecca L. Shaner; Leila Heidari; Samantha L. Isenberg; Jonas W. Perez; Leigh Ann Graham; Jerry D. Thomas; Rudolph C. Johnson; Aren E. Gerdon

The Multi-Rule Quality Control System (MRQCS) is a tool currently employed by the Centers for Disease Control and Prevention (CDC) to evaluate and compare laboratory performance. We have applied the MRQCS to a comparison of instructor and computer-led pre-laboratory lectures for a supplemental learning experiment. Students in general chemistry and analytical chemistry from both two- and four-year institutions performed two laboratory experiments as part of their normal laboratory curriculum. The first laboratory experiment was a foundational learning experiment in which all the students were introduced to Beer-Lamberts Law and spectrophotometric light absorbance measurements. The foundational learning experiment was instructor-led only, and participant performance was evaluated against a mean characterized value. The second laboratory experiment was a supplemental learning experiment in which students were asked to build upon the methodology they learned in the foundational learning experiment and apply it to a different analyte. The instruction type was varied randomly into two delivery modes, participants receiving either instructor-led or computer-led pre-laboratory instruction. The MRQCS was applied and determined that no statistical difference was found to exist in the QC (quality control) passing rates between the participants in the instructor-led instruction and the participants in the computer-led instruction. These findings demonstrate the successful application of the MRQCS to evaluate knowledge and technology transfer.


Analytical Chemistry | 2013

Direct quantitation of methyl phosphonate adducts to human serum butyrylcholinesterase by immunomagnetic-UHPLC-MS/MS.

Melissa D. Carter; Brian S. Crow; Brooke G. Pantazides; Caroline Watson; Jerry D. Thomas; Thomas A. Blake; Rudolph C. Johnson


Analytical and Bioanalytical Chemistry | 2014

An Enhanced Butyrylcholinesterase Method to Measure Organophosphorus Nerve Agent Exposure in Humans

Brooke G. Pantazides; Caroline M. Watson; Melissa D. Carter; Brian S. Crow; Jonas W. Perez; Thomas A. Blake; Jerry D. Thomas; Rudolph C. Johnson

Collaboration


Dive into the Brian S. Crow's collaboration.

Top Co-Authors

Avatar

Rudolph C. Johnson

Centers for Disease Control and Prevention

View shared research outputs
Top Co-Authors

Avatar

Jerry D. Thomas

Centers for Disease Control and Prevention

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Brooke G. Pantazides

Centers for Disease Control and Prevention

View shared research outputs
Top Co-Authors

Avatar

Melissa D. Carter

Centers for Disease Control and Prevention

View shared research outputs
Top Co-Authors

Avatar

Jonas W. Perez

Battelle Memorial Institute

View shared research outputs
Top Co-Authors

Avatar

Caroline M. Watson

Oak Ridge Institute for Science and Education

View shared research outputs
Top Co-Authors

Avatar

Jennifer Quiñones-González

Centers for Disease Control and Prevention

View shared research outputs
Top Co-Authors

Avatar

Joshua W. Garton

Oak Ridge Institute for Science and Education

View shared research outputs
Top Co-Authors

Avatar

Leigh Ann Graham

Centers for Disease Control and Prevention

View shared research outputs
Researchain Logo
Decentralizing Knowledge