Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Brian Whisenant is active.

Publication


Featured researches published by Brian Whisenant.


The New England Journal of Medicine | 2012

Two-year outcomes after transcatheter or surgical aortic-valve replacement.

Susheel Kodali; Mathew R. Williams; Craig R. Smith; Lars G. Svensson; John G. Webb; Raj Makkar; Gregory P. Fontana; Todd M. Dewey; Vinod H. Thourani; Augusto D. Pichard; Michael P. Fischbein; Wilson Y. Szeto; Scott Lim; Kevin L. Greason; Paul S. Teirstein; S. Chris Malaisrie; Pamela S. Douglas; Rebecca T. Hahn; Brian Whisenant; Alan Zajarias; Duolao Wang; Jodi J. Akin; William N. Anderson; Martin B. Leon; Trial Investigators

BACKGROUND The Placement of Aortic Transcatheter Valves (PARTNER) trial showed that among high-risk patients with aortic stenosis, the 1-year survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical replacement. However, longer-term follow-up is necessary to determine whether TAVR has prolonged benefits. METHODS At 25 centers, we randomly assigned 699 high-risk patients with severe aortic stenosis to undergo either surgical aortic-valve replacement or TAVR. All patients were followed for at least 2 years, with assessment of clinical outcomes and echocardiographic evaluation. RESULTS The rates of death from any cause were similar in the TAVR and surgery groups (hazard ratio with TAVR, 0.90; 95% confidence interval [CI], 0.71 to 1.15; P=0.41) and at 2 years (Kaplan-Meier analysis) were 33.9% in the TAVR group and 35.0% in the surgery group (P=0.78). The frequency of all strokes during follow-up did not differ significantly between the two groups (hazard ratio, 1.22; 95% CI, 0.67 to 2.23; P=0.52). At 30 days, strokes were more frequent with TAVR than with surgical replacement (4.6% vs. 2.4%, P=0.12); subsequently, there were 8 additional strokes in the TAVR group and 12 in the surgery group. Improvement in valve areas was similar with TAVR and surgical replacement and was maintained for 2 years. Paravalvular regurgitation was more frequent after TAVR (P<0.001), and even mild paravalvular regurgitation was associated with increased late mortality (P<0.001). CONCLUSIONS A 2-year follow-up of patients in the PARTNER trial supports TAVR as an alternative to surgery in high-risk patients. The two treatments were similar with respect to mortality, reduction in symptoms, and improved valve hemodynamics, but paravalvular regurgitation was more frequent after TAVR and was associated with increased late mortality. (Funded by Edwards Lifesciences; ClinicalTrials.gov number, NCT00530894.).


The New England Journal of Medicine | 2016

Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients

Martin B. Leon; Craig R. Smith; Michael J. Mack; Raj Makkar; Lars G. Svensson; Susheel Kodali; Vinod H. Thourani; E. Murat Tuzcu; D. Craig Miller; Howard C. Herrmann; Darshan Doshi; David J. Cohen; Augusto D. Pichard; Samir Kapadia; Todd M. Dewey; Vasilis Babaliaros; Wilson Y. Szeto; Mathew R. Williams; Alan Zajarias; Kevin L. Greason; Brian Whisenant; Robert W. Hodson; Jeffrey W. Moses; Alfredo Trento; David L. Brown; William F. Fearon; Philippe Pibarot; Rebecca T. Hahn; Wael A. Jaber; William N. Anderson

BACKGROUND Previous trials have shown that among high-risk patients with aortic stenosis, survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical aortic-valve replacement. We evaluated the two procedures in a randomized trial involving intermediate-risk patients. METHODS We randomly assigned 2032 intermediate-risk patients with severe aortic stenosis, at 57 centers, to undergo either TAVR or surgical replacement. The primary end point was death from any cause or disabling stroke at 2 years. The primary hypothesis was that TAVR would not be inferior to surgical replacement. Before randomization, patients were entered into one of two cohorts on the basis of clinical and imaging findings; 76.3% of the patients were included in the transfemoral-access cohort and 23.7% in the transthoracic-access cohort. RESULTS The rate of death from any cause or disabling stroke was similar in the TAVR group and the surgery group (P=0.001 for noninferiority). At 2 years, the Kaplan-Meier event rates were 19.3% in the TAVR group and 21.1% in the surgery group (hazard ratio in the TAVR group, 0.89; 95% confidence interval [CI], 0.73 to 1.09; P=0.25). In the transfemoral-access cohort, TAVR resulted in a lower rate of death or disabling stroke than surgery (hazard ratio, 0.79; 95% CI, 0.62 to 1.00; P=0.05), whereas in the transthoracic-access cohort, outcomes were similar in the two groups. TAVR resulted in larger aortic-valve areas than did surgery and also resulted in lower rates of acute kidney injury, severe bleeding, and new-onset atrial fibrillation; surgery resulted in fewer major vascular complications and less paravalvular aortic regurgitation. CONCLUSIONS In intermediate-risk patients, TAVR was similar to surgical aortic-valve replacement with respect to the primary end point of death or disabling stroke. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313.).


The Lancet | 2016

Transcatheter aortic valve replacement versus surgical valve replacement in intermediate-risk patients: a propensity score analysis

Vinod H. Thourani; Susheel Kodali; Raj Makkar; Howard C. Herrmann; Mathew R. Williams; Vasilis Babaliaros; Richard W. Smalling; Scott Lim; S. Chris Malaisrie; Samir Kapadia; Wilson Y. Szeto; Kevin L. Greason; Gorav Ailawadi; Brian Whisenant; Chandan Devireddy; Jonathon Leipsic; Rebecca T. Hahn; Philippe Pibarot; Neil J. Weissman; Wael A. Jaber; David Cohen; Rakesh M. Suri; E. Murat Tuzcu; Lars G. Svensson; John G. Webb; Jeffrey W. Moses; Michael J. Mack; D. Craig Miller; Craig R. Smith; Maria Alu

BACKGROUND Transcatheter aortic valve replacement (TAVR) with the SAPIEN 3 valve demonstrates good 30 day clinical outcomes in patients with severe aortic stenosis who are at intermediate risk of surgical mortality. Here we report longer-term data in intermediate-risk patients given SAPIEN 3 TAVR and compare outcomes to those of intermediate-risk patients given surgical aortic valve replacement. METHODS In the SAPIEN 3 observational study, 1077 intermediate-risk patients at 51 sites in the USA and Canada were assigned to receive TAVR with the SAPIEN 3 valve [952 [88%] via transfemoral access) between Feb 17, 2014, and Sept 3, 2014. In this population we assessed all-cause mortality and incidence of strokes, re-intervention, and aortic valve regurgitation at 1 year after implantation. Then we compared 1 year outcomes in this population with those for intermediate-risk patients treated with surgical valve replacement in the PARTNER 2A trial between Dec 23, 2011, and Nov 6, 2013, using a prespecified propensity score analysis to account for between-trial differences in baseline characteristics. The clinical events committee and echocardiographic core laboratory methods were the same for both studies. The primary endpoint was the composite of death from any cause, all strokes, and incidence of moderate or severe aortic regurgitation. We did non-inferiority (margin 7·5%) and superiority analyses in propensity score quintiles to calculate pooled weighted proportion differences for outcomes. FINDINGS At 1 year follow-up of the SAPIEN 3 observational study, 79 of 1077 patients who initiated the TAVR procedure had died (all-cause mortality 7·4%; 6·5% in the transfemoral access subgroup), and disabling strokes had occurred in 24 (2%), aortic valve re-intervention in six (1%), and moderate or severe paravalvular regurgitation in 13 (2%). In the propensity-score analysis we included 963 patients treated with SAPIEN 3 TAVR and 747 with surgical valve replacement. For the primary composite endpoint of mortality, strokes, and moderate or severe aortic regurgitation, TAVR was both non-inferior (pooled weighted proportion difference of -9·2%; 90% CI -12·4 to -6; p<0·0001) and superior (-9·2%, 95% CI -13·0 to -5·4; p<0·0001) to surgical valve replacement. INTERPRETATION TAVR with SAPIEN 3 in intermediate-risk patients with severe aortic stenosis is associated with low mortality, strokes, and regurgitation at 1 year. The propensity score analysis indicates a significant superiority for our composite outcome with TAVR compared with surgery, suggesting that TAVR might be the preferred treatment alternative in intermediate-risk patients. FUNDING None.


JAMA | 2014

Percutaneous Left Atrial Appendage Closure vs Warfarin for Atrial Fibrillation A Randomized Clinical Trial

Vivek Y. Reddy; Horst Sievert; Jonathan L. Halperin; Shephal K. Doshi; Maurice Buchbinder; Petr Neuzil; Kenneth C. Huber; Brian Whisenant; Saibal Kar; Vijay Swarup; Nicole Gordon; David R. Holmes

IMPORTANCE While effective in preventing stroke in patients with atrial fibrillation (AF), warfarin is limited by a narrow therapeutic profile, a need for lifelong coagulation monitoring, and multiple drug and diet interactions. OBJECTIVE To determine whether a local strategy of mechanical left atrial appendage (LAA) closure was noninferior to warfarin. DESIGN, SETTING, AND PARTICIPANTS PROTECT AF was a multicenter, randomized (2:1), unblinded, Bayesian-designed study conducted at 59 hospitals of 707 patients with nonvalvular AF and at least 1 additional stroke risk factor (CHADS2 score ≥1). Enrollment occurred between February 2005 and June 2008 and included 4-year follow-up through October 2012. Noninferiority required a posterior probability greater than 97.5% and superiority a probability of 95% or greater; the noninferiority margin was a rate ratio of 2.0 comparing event rates between treatment groups. INTERVENTIONS Left atrial appendage closure with the device (n = 463) or warfarin (n = 244; target international normalized ratio, 2-3). MAIN OUTCOMES AND MEASURES A composite efficacy end point including stroke, systemic embolism, and cardiovascular/unexplained death, analyzed by intention-to-treat. RESULTS At a mean (SD) follow-up of 3.8 (1.7) years (2621 patient-years), there were 39 events among 463 patients (8.4%) in the device group for a primary event rate of 2.3 events per 100 patient-years, compared with 34 events among 244 patients (13.9%) for a primary event rate of 3.8 events per 100 patient-years with warfarin (rate ratio, 0.60; 95% credible interval, 0.41-1.05), meeting prespecified criteria for both noninferiority (posterior probability, >99.9%) and superiority (posterior probability, 96.0%). Patients in the device group demonstrated lower rates of both cardiovascular mortality (1.0 events per 100 patient-years for the device group [17/463 patients, 3.7%] vs 2.4 events per 100 patient-years with warfarin [22/244 patients, 9.0%]; hazard ratio [HR], 0.40; 95% CI, 0.21-0.75; P = .005) and all-cause mortality (3.2 events per 100 patient-years for the device group [57/466 patients, 12.3%] vs 4.8 events per 100 patient-years with warfarin [44/244 patients, 18.0%]; HR, 0.66; 95% CI, 0.45-0.98; P = .04). CONCLUSIONS AND RELEVANCE After 3.8 years of follow-up among patients with nonvalvular AF at elevated risk for stroke, percutaneous LAA closure met criteria for both noninferiority and superiority, compared with warfarin, for preventing the combined outcome of stroke, systemic embolism, and cardiovascular death, as well as superiority for cardiovascular and all-cause mortality. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00129545.


European Heart Journal | 2016

Early clinical and echocardiographic outcomes after SAPIEN 3 transcatheter aortic valve replacement in inoperable, high-risk and intermediate-risk patients with aortic stenosis

Susheel Kodali; Vinod H. Thourani; Jonathon White; S. Chris Malaisrie; Scott Lim; Kevin L. Greason; Mathew R. Williams; Mayra Guerrero; Andrew C. Eisenhauer; Samir Kapadia; Howard C. Herrmann; Vasilis Babaliaros; Wilson Y. Szeto; Rebecca T. Hahn; Philippe Pibarot; Neil J. Weissman; Jonathon Leipsic; Philipp Blanke; Brian Whisenant; Rakesh M. Suri; Rajendra Makkar; Girma Minalu Ayele; Lars G. Svensson; John G. Webb; Michael J. Mack; Craig R. Smith; Martin B. Leon

AIMS Based on randomized trials using first-generation devices, transcatheter aortic valve replacement (TAVR) is well established in the treatment of high-risk (HR) patients with severe aortic stenosis (AS). To date, there is a paucity of adjudicated, prospective data evaluating outcomes with newer generation devices and in lower risk patients. We report early outcomes of a large, multicentre registry of inoperable, HR, and intermediate-risk (IR) patients undergoing treatment with the next-generation SAPIEN 3 transcatheter heart valve (THV). METHODS AND RESULTS Patients with severe, symptomatic AS (583 high surgical risk or inoperable and 1078 IR) were enrolled in a multicentre, non-randomized registry at 57 sites in the USA and Canada. All patients received TAVR with the SAPIEN 3 system via transfemoral (n = 1443, 86.9%) and transapical or transaortic (n = 218, 13.1%) access routes. The rate of 30-day all-cause mortality was 2.2% in HR/inoperable patients [mean Society of Thoracic Surgeons (STS) score 8.7%] and 1.1% in IR patients (mean STS score 5.3%); cardiovascular mortality was 1.4 and 0.9%, respectively. In HR/inoperable patients, the 30-day rate of major/disabling stroke was 0.9%, major bleeding 14.0%, major vascular complications 5.1%, and requirement for permanent pacemaker 13.3%. In IR patients, the 30-day rate of major/disabling stroke was 1.0%, major bleeding 10.6%, major vascular complications 6.1%, and requirement for permanent pacemaker 10.1%. Mean overall Kansas City Cardiomyopathy Questionnaire score increased from 47.8 to 67.8 (HR/inoperable, P < 0.0001) and 54.7 to 74.0 (IR, P < 0.0001). Overall, paravalvular regurgitation at 30 days was none/trace in 55.9% of patients, mild in 40.7%, moderate in 3.4%, and severe in 0.0%. Mean gradients among patients with paired baseline and 30-day or discharge echocardiograms decreased from 45.8 mmHg at baseline to 11.4 mmHg at 30 days, while aortic valve area increased from 0.69 to 1.67 cm(2). CONCLUSIONS The SAPIEN 3 THV system was associated with low rates of 30-day mortality and major/disabling stroke as well as low rates of moderate or severe paravalvular regurgitation. TRIAL REGISTRATION ClinicalTrials.gov #NCT01314313.


Journal of the American College of Cardiology | 2013

Determinants and Outcomes of Acute Transcatheter Valve-in-Valve Therapy or Embolization: A Study of Multiple Valve Implants in the U.S. PARTNER Trial (Placement of AoRTic TraNscathetER Valve Trial Edwards SAPIEN Transcatheter Heart Valve)

Raj Makkar; Hasan Jilaihawi; Tarun Chakravarty; Gregory P. Fontana; Samir Kapadia; Vasilis Babaliaros; Wen Cheng; Vinod H. Thourani; Joseph E. Bavaria; Lars G. Svensson; Susheel Kodali; Takahiro Shiota; Robert J. Siegel; E. Murat Tuzcu; Ke Xu; Rebecca T. Hahn; Howard C. Herrmann; Mark Reisman; Brian Whisenant; Scott Lim; Nirat Beohar; Michael J. Mack; Paul S. Teirstein; Charanjit S. Rihal; Pamela S. Douglas; Eugene H. Blackstone; Augusto D. Pichard; John G. Webb; Martin B. Leon

OBJECTIVES This study investigated the determinants and outcomes of acute insertion of a second transcatheter prosthetic valve (TV) within the first (TV-in-TV) or transcatheter valve embolization (TVE) after transcatheter aortic valve replacement (TAVR). BACKGROUND TAVR failure can occur with both TV-in-TV and TVE as a consequence of TAVR malpositioning. Only case reports and limited series pertaining to these complications have been reported to date. METHODS Patients undergoing TAVR in the PARTNER (Placement of AoRTic TraNscathetER Valve Trial Edwards SAPIEN Transcatheter Heart Valve) randomized trial (cohorts A and B) and accompanying registries were studied. Data were dichotomized for those with and without TV-in-TV or TVE, respectively. RESULTS From a total of 2,554 consecutive patients, 63 (2.47%) underwent TV-in-TV and 26 (1.01%) TVE. The indication for TV-in-TV was significant aortic regurgitation in most patients, often due not only to malpositioning but also to leaflet dysfunction. Despite similar aortic valve function on follow-up echoes, TV-in-TV was an independent predictor of 1-year cardiovascular mortality (hazard ratio [HR]: 1.86, 95% confidence interval [CI]: 1.03 to 3.38, p = 0.041), with a nonsignificant trend toward greater all-cause mortality (HR: 1.43, 95% CI: 0.88 to 2.33, p = 0.15). Technical and anatomical reasons accounted for most cases of TVE. A multivariable analysis found TVE to be an independent predictor of 1-year mortality (HR: 2.68, 95% CI: 1.34 to 5.36, p = 0.0055) but not cardiovascular mortality (HR: 1.30, 95% CI: 0.48 to 3.52, p = 0.60). CONCLUSIONS Acute TV-in-TV and TVE are serious sequelae of TAVR, often resulting in multiple valve implants. They carry an excess of mortality and are caused by anatomic and technical factors, which may be avoidable with judicious procedural planning.


Circulation | 2016

One-year clinical outcomes with SAPIEN 3 transcatheter aortic valve replacement in high-risk and inoperable patients with severe aortic stenosis

Howard C. Herrmann; Vinod H. Thourani; Susheel Kodali; Rajendra Makkar; Wilson Y. Szeto; Saif Anwaruddin; Nimesh D. Desai; Scott Lim; S. Chris Malaisrie; S. R. Ramee; Kevin L. Greason; Samir Kapadia; Vasilis Babaliaros; Rebecca T. Hahn; Philippe Pibarot; Neil J. Weissman; Jonathon Leipsic; Brian Whisenant; John G. Webb; Michael J. Mack; Martin B. Leon

Background: In the initial PARTNER trial (Placement of Aortic Transcatheter Valves) of transcatheter aortic valve replacement for high-risk (HR) and inoperable patients, mortality at 1 year was 24% in HR and 31% in inoperable patients. A recent report of the 30-day outcomes with the low-profile SAPIEN 3 transcatheter aortic valve replacement system demonstrated very low rates of adverse events, but little is known about the longer-term outcomes with this device. Methods: Between October 2013 and September 2014, 583 HR (65%) or inoperable (35%) patients were treated via the transfemoral (84%) or transapical/transaortic (16%) access route at 29 US sites. Major clinical events at 1 year were adjudicated by an independent clinical events committee, and echocardiographic results were analyzed by a core laboratory. Results: Baseline characteristics included age of 83 years, 42% female, and median Society of Thoracic Surgeons score of 8.4%. At the 1-year follow-up, survival (all-cause) was 85.6% for all patients, 87.3% in the HR subgroup, and 82.3% in the inoperable subgroup. Survival free of all-cause and cardiovascular mortality in the transfemoral patients from the HR cohort was 87.7% and 93.3%, respectively. There was no severe paravalvular leak. Moderate paravalvular leak (2.7%) was associated with an increase in mortality at 1 year, whereas mild paravalvular leak had no significant association with mortality. Symptomatic improvement as assessed by the percentage of patients in New York Heart Association class III and IV (90.1% to 7.7% at 1 year; P<0.0001) and by Kansas City Cardiomyopathy Questionnaire overall summary score (improved from 46.9 to 72.4; P<0.0001) was marked. Multivariable predictors of 1-year mortality included alternative access, Society of Thoracic Surgeons score, and disabling stroke. Conclusions: In this large, adjudicated registry of SAPIEN 3 HR and inoperable patients, the very low rates of important complications resulted in a strikingly low mortality rate at 1 year. Between 30 and 365 days, the incidence of moderate paravalvular aortic regurgitation did not increase, and no association between mild paravalvular leak and 1-year mortality was observed, although a small increase in disabling stroke occurred. These results, which likely reflect device iteration and procedural evolution, support the use of transcatheter aortic valve replacement as the preferred therapy in HR and inoperable patients with aortic stenosis. Clinical Trial Registration : URL: http://www.clinicaltrials.gov. Unique identifier: NCT01314313.


Journal of the American College of Cardiology | 2013

Quality of Life Assessment in the Randomized PROTECT AF (Percutaneous Closure of the Left Atrial Appendage Versus Warfarin Therapy for Prevention of Stroke in Patients With Atrial Fibrillation) Trial of Patients at Risk for Stroke With Nonvalvular Atrial Fibrillation

Oluseun Alli; Shepal Doshi; Saibal Kar; Vivek Y. Reddy; Horst Sievert; Christopher M. Mullin; Vijay Swarup; Brian Whisenant; David R. Holmes

OBJECTIVES This study sought to assess quality of life parameters in a subset of patients enrolled in the PROTECT AF (Percutaneous Closure of the Left Atrial Appendage Versus Warfarin Therapy for Prevention of Stroke in Patients With Atrial Fibrillation) trial. BACKGROUND The PROTECT AF (Percutaneous Closure of the Left Atrial Appendage Versus Warfarin Therapy for Prevention of Stroke in Patients With Atrial Fibrillation) trial demonstrated that in patients with nonvalvular atrial fibrillation (AF) and CHADS2 (congestive heart failure, hypertension, age, diabetes mellitus, and prior stroke, transient ischemic attack, or thromboembolism) score ≥1, a left atrial appendage closure device is noninferior to long-term warfarin for stroke prevention. Given this equivalency, quality of life (QOL) indicators are an important metric for evaluating these 2 different strategies. METHODS QOL using the Short-Form 12 Health Survey, version 2, measurement tool was obtained at baseline and 12 months in a subset of 547 patients in the PROTECT AF trial (361 device and 186 warfarin patients). The analysis cohort consisted of patients for whom either paired quality of life data were available after 12 months of follow-up or for patients who died. RESULTS With the device, the total physical score improved in 34.9% and was unchanged in 29.9% versus warfarin in whom 24.7% were improved and 31.7% were unchanged (p = 0.01). Mental health improvement occurred in 33.0% of the device group versus 22.6% in the warfarin group (p = 0.06). There was a significant improvement in QOL in patients randomized to device for total physical score, physical function, and in physical role limitation compared to control. There were significant differences in the change in total physical score among warfarin naive and not-warfarin naive subgroups in the device group compared to control, but larger gains were seen with the warfarin naive subgroup with a 12-month change of 1.3 ± 8.8 versus -3.6 ± 6.7 (p = 0.0004) device compared to warfarin. CONCLUSIONS Patients with nonvalvular AF at risk for stroke treated with left atrial appendage closure have favorable QOL changes at 12 months versus patients treated with warfarin. (WATCHMAN Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation [WATCHMAN PROTECT]; NCT00129545).


Circulation-cardiovascular Interventions | 2015

Effect of Tricuspid Regurgitation and the Right Heart on Survival After Transcatheter Aortic Valve Replacement Insights From the Placement of Aortic Transcatheter Valves II Inoperable Cohort

Brian R. Lindman; Hersh S. Maniar; Wael A. Jaber; Stamatios Lerakis; Michael J. Mack; Rakesh M. Suri; Vinod H. Thourani; Vasilis Babaliaros; Brian Whisenant; D. Craig Miller; E. Murat Tuzcu; Lars G. Svensson; Ke Xu; Darshan Doshi; Martin B. Leon; Alan Zajarias

Background—Tricuspid regurgitation (TR) and right ventricular (RV) dysfunction adversely affect outcomes in patients with heart failure or mitral valve disease, but their impact on outcomes in patients with aortic stenosis treated with transcatheter aortic valve replacement has not been well characterized. Methods and Results—Among 542 patients with symptomatic aortic stenosis treated in the Placement of Aortic Transcatheter Valves (PARTNER) II trial (inoperable cohort) with a Sapien or Sapien XT valve via a transfemoral approach, baseline TR severity, right atrial and RV size and RV function were evaluated by echocardiography according to established guidelines. One-year mortality was 16.9%, 17.2%, 32.6%, and 61.1% for patients with no/trace (n=167), mild (n=205), moderate (n=117), and severe (n=18) TR, respectively (P<0.001). Increasing severity of RV dysfunction as well as right atrial and RV enlargement were also associated with increased mortality (P<0.001). After multivariable adjustment, severe TR (hazard ratio, 3.20; 95% confidence interval, 1.50–6.82; P=0.003) and moderate TR (hazard ratio, 1.60; 95% confidence interval, 1.02–2.52; P=0.042) remained associated with increased mortality as did right atrial and RV enlargement, but not RV dysfunction. There was an interaction between TR and mitral regurgitation severity (P=0.04); the increased hazard of death associated with moderate/severe TR only occurred in those with no/trace/mild mitral regurgitation. Conclusions—In inoperable patients treated with transcatheter aortic valve replacement, moderate or severe TR and right heart enlargement are independently associated with increased 1-year mortality; however, the association between moderate or severe TR and an increased hazard of death was only found in those with minimal mitral regurgitation at baseline. These findings may improve our assessment of anticipated benefit from transcatheter aortic valve replacement and support the need for future studies on TR and the right heart, including whether concomitant treatment of TR in operable but high-risk patients with aortic stenosis is warranted. Clinical Trial Registration—URL: http://www.clinicaltrials.gov. Unique identifier: NCT01314313.


Jacc-cardiovascular Interventions | 2015

A Randomized Evaluation of the SAPIEN XT Transcatheter Heart Valve System in Patients With Aortic Stenosis Who Are Not Candidates for Surgery

John G. Webb; Darshan Doshi; Michael J. Mack; Raj Makkar; Craig R. Smith; Augusto D. Pichard; Susheel Kodali; Samir Kapadia; D. Craig Miller; Vasilis Babaliaros; Vinod H. Thourani; Howard C. Herrmann; Mark Bodenhamer; Brian Whisenant; Hersh S. Maniar; Ke Xu; Wael A. Jaber; Venu Menon; E. Murat Tuzcu; David A. Wood; Lars G. Svensson; Martin B. Leon

OBJECTIVES The purpose of this study was to determine the safety and effectiveness of the SAPIEN XT versus SAPIEN systems (Edwards Lifesciences, Irvine, California) in patients with symptomatic, severe aortic stenosis (AS) who were not candidates for surgery. BACKGROUND Transcatheter aortic valve replacement (TAVR) has become the standard of care for inoperable patients with severe, symptomatic AS. In the PARTNER (Placement of Aortic Transcatheter Valves) IB trial, a reduction in all-cause mortality was observed in patients undergoing TAVR with the balloon-expandable SAPIEN transcatheter heart valve compared with standard therapy, but the SAPIEN valve was associated with adverse periprocedural complications, including vascular complications, major bleeding, and paravalvular regurgitation. The newer, low-profile SAPIEN XT system was developed to reduce these adverse events. METHODS A total of 560 patients were enrolled at 28 sites in the United States from April 2011 to February 2012. Patients were randomized to receive the SAPIEN or SAPIEN XT systems. The primary endpoint was a nonhierarchical composite of all-cause mortality, major stroke, and rehospitalization at 1 year in the intention-to-treat population, assessed by noninferiority testing. Pre-specified secondary endpoints included cardiovascular death, New York Heart Association functional class, myocardial infarction, stroke, acute kidney injury, vascular complications, bleeding, 6-min walk distance, and valve performance (by echocardiography). RESULTS Both overall and major vascular complications were higher at 30 days in patients undergoing TAVR with SAPIEN compared with SAPIEN XT (overall: 22.1% vs. 15.5%; p = 0.04; major: 15.2% vs. 9.5%; p = 0.04). Bleeding requiring blood transfusions was also more frequent with SAPIEN compared with SAPIEN XT (10.6% vs. 5.3%; p = 0.02). At 1-year follow-up, the nonhierarchical composite of all-cause mortality, major stroke, or rehospitalization was similar (37.7% SAPIEN vs. 37.2% SAPIEN XT; noninferiority p value <0.002); no differences in the other major pre-specified endpoints were found. CONCLUSIONS In inoperable patients with severe, symptomatic AS, the lower-profile SAPIEN XT is noninferior to SAPIEN with fewer vascular complications and a lesser need for blood transfusion. (The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves; NCT01314313).

Collaboration


Dive into the Brian Whisenant's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Martin B. Leon

Columbia University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Susheel Kodali

Columbia University Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Raj Makkar

Cedars-Sinai Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Craig R. Smith

Columbia University Medical Center

View shared research outputs
Researchain Logo
Decentralizing Knowledge