Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology | 2010
Bruno Carvalho de Vasconcelos; Tainá Macedo do Vale; Antônio Sérgio Teixeira de Menezes; Elilton Cavalcante Pinheiro-Júnior; Nilton Vivacqua-Gomes; Ricardo Affonso Bernardes; Marco Antonio Hungaro Duarte
OBJECTIVE The aim of this study was to evaluate the precision of working length determination of 3 electronic apex locators (EALs): Root ZX, RomiApex D-30, and Ipex at 0.0 mm, at the apical foramen (AF), and at 1.0 mm short of the AF. METHODOLOGY Thirty-eight mandibular premolars had their real lengths previously determined. Electronic measurements were determined at 1.0 mm, followed by measurements at 0.0 mm, performed in triplicate. RESULTS Precision of devices at 1.0 mm and 0.0 mm were: 94.7% and 97.4%, respectively (Root ZX); 78.9% and 97.4% (RomiApex D-30); and 76.3% and 97.4% (Ipex). Although no statistical differences were observed between the EALs at 0.0, at 1.0 mm Root ZX performed significantly better than the others. CONCLUSION The EALs had acceptable precision when measuring the working length at the AF. However, when used at levels short of the AF, only Root ZX did not suffer a significant negative effect on precision.
Journal of Applied Oral Science | 2007
Bruno Carvalho de Vasconcelos; Suyane Maria Luna-Cruz; Gustavo De-Deus; Ivaldo Gomes de Moraes; Claudio Maniglia-Ferreira; Eduardo Diogo Gurgel-Filho
The aim of this study was to evaluate the cleaning efficacy of 2% chlorhexidine gluconate gel (CHX) compared to 2.5% sodium hypochlorite solution (NaOCl) associated or not with 17% EDTA used as irrigants during the biomechanical preparation. Fifty freshly extracted single-rooted human teeth with complete apex formation were randomly divided into five groups: G1 - sterile saline, G2 - 2.5% NaOCl, G3 - 2% CHX, G4 - 2.5% NaOCl + EDTA and G5 - 2% CHX + EDTA. The specimens of G1 were subdivided into two control groups. The teeth were decoronated and the coronal and middle root thirds were prepared with Gates-Glidden burs, and the apical third was reserved to manual instrumentation. All procedures were performed by a single operator. In all groups, 2 mL of irrigant was delivered between each file change. The teeth were sectioned and prepared for analyses under scanning electron microscopy (SEM). SEM micrographs were graded according to a score scale by two examiners. Data were analyzed statistically by Kruskal-Wallis and Dunn tests at 1% significance level. The best results were obtained in the groups in which the irrigant was used followed by the chelating agent. No statistically significant difference was observed among G4, G5 and the positive control group (p<0.01). The groups G2 and G3 were significantly different from the others, presenting the worst cleaning capacity. In conclusion, the use of the chelating agent is necessary to obtain clean canal walls, with open tubules and no heavy debris. The use of 2% chlorhexidine gluconate gel alone is not able to remove the smear layer.
Journal of Applied Oral Science | 2013
Bruno Carvalho de Vasconcelos; Michelli de Medeiros Bueno; Suyane Maria Luna-Cruz; Marco Antonio Hungaro Duarte; Carlos Augusto de Oliveira Fernandes
Objective: The aim of this study was to evaluate, ex vivo, the precision of five electronic root canal length measurement devices (ERCLMDs) with different operating systems: the Root ZX, Mini Apex Locator, Propex II, iPex, and RomiApex A-15, and the possible influence of the positioning of the instrument tips short of the apical foramen. Material and Methods: Forty-two mandibular bicuspids had their real canal lengths (RL) previously determined. Electronic measurements were performed 1.0 mm short of the apical foramen (-1.0), followed by measurements at the apical foramen (0.0). The data resulting from the comparison of the ERCLMD measurements and the RL were evaluated by the Wilcoxon and Friedman tests at a significance level of 5%. Results: Considering the measurements performed at 0.0 and -1.0, the precision rates for the ERCLMDs were: 73.5% and 47.1% (Root ZX), 73.5% and 55.9% (Mini Apex Locator), 67.6% and 41.1% (Propex II), 61.7% and 44.1% (iPex), and 79.4% and 44.1% (RomiApex A-15), respectively, considering ±0.5 mm of tolerance. Regarding the mean discrepancies, no differences were observed at 0.0; however, in the measurements at -1.0, the iPex, a multi-frequency ERCLMD, had significantly more discrepant readings short of the apical foramen than the other devices, except for the Propex II, which had intermediate results. When the ERCLMDs measurements at -1.0 were compared with those at 0.0, the Propex II, iPex and RomiApex A-15 presented significantly higher discrepancies in their readings. Conclusions: Under the conditions of the present study, all the ERCLMDs provided acceptable measurements at the 0.0 position. However, at the -1.0 position, the ERCLMDs had a lower precision, with statistically significant differences for the Propex II, iPex, and RomiApex A-15.
Brazilian Dental Journal | 2012
Bruno Carvalho de Vasconcelos; Leonardo de Alencar Matos; Elilton Cavalcante Pinheiro-Júnior; Antônio Sérgio Teixeira de Menezes; Nilton Vivacqua-Gomes
This study evaluated the accuracy of three electronic apex locators (Root ZX, Novapex, and Justy II) in root canal length determinations using different apical file sizes, considering the apical constriction (AC) and the major foramen (MF) as anatomic references. The diameter of the apical foramina of 40 single-rooted teeth was determined by direct visual measurement and the master apical file was established. Electronic measurements were then performed using 3 instruments: the selected master apical file (adjusted file), one size smaller (intermediate file), and two sizes smaller (misfit file). The distances from the tip of files fixed in the canals to the MF and to the AC were measured digitally. Precision at AC and at MF for the misfit, intermediate and adjusted apical files was as follows: 80%/88%/83% and 78%/83%/95% (Root ZX); 80%/85%/80% and 68%/73%/73% (Novapex); and 78%/80%/78% and 65%/78%/70% (Justy II). Considering the mean discrepancies, statistically significant differences were found only for the adjusted file at MF, with Root ZX presenting the best results at MF. The chi-square test showed significant differences between the acceptable measurements at AC and at MF for the Justy II and Novapex (± 0.5 mm) regardless of file adjustment. Under the conditions of the present study, all devices provided acceptable electronic measurements regardless of file adjustment, except for Root ZX which had its performance improved significantly when the precisely fit apical file was used. Justy II and Novapex provided electronic measurements nearest to the AC.
Brazilian Dental Journal | 2011
Marco Antonio Hungaro Duarte; Ricardo Affonso Bernardes; Ronald Ordinola-Zapata; Bruno Carvalho de Vasconcelos; Clovis Monteiro Bramante; Ivaldo Gomes de Moraes
This study evaluated the increase of the instrumented area and dentin thickness in the mesial and distal aspects of mesial canals of mandibular molars after the use of Gates Glidden (GG), LA Axxess (LA) and Orifice Shaper (OS) instruments. A total of 53 canals from 27 mandibular molars were embedded in resin and divided into 3 groups. The roots were sectioned 3 mm below the cementoenamel junction and the images were captured before and after instrumentation. The increase of the instrumented area in terms of percentages and the remaining dentin thickness, in mm, at the mesial and furcal aspects were calculated using the Image tools software. Data were analyzed using the Kruskal-Wallis and Dunns test. The significance level was set at 5%. All instruments promoted cervical flaring with different amounts of dentin removal at the mesial and distal aspects of the root canals. Statistically significant difference (p<0.05) was found between LA and all other instruments after using the first instrument. Regarding dentin thickness, no significant difference (p>0.05) was found between the mesial and distal walls in all groups. It may be concluded that LA 35.06 and GG 3 burs produced the thinnest dentin walls, and thus their use in mesial canals of mandibular molars should be done with caution.
Journal of Applied Oral Science | 2017
Jussaro Alves Duque; Rodrigo Ricci Vivan; Bruno Cavalini Cavenago; Pablo Andrés Amoroso-Silva; Ricardo Affonso Bernardes; Bruno Carvalho de Vasconcelos; Marco Antonio Hungaro Duarte
Abstract Objective This study aimed to evaluate the influence of the NiTi wire in Conventional NiTi (ProTaper Universal PTU) and Controlled Memory NiTi (ProTaper Gold PTG) instrument systems on the quality of root canal preparation. Material and Methods Twelve mandibular molars with separate mesial canals were scanned using a high-definition microcomputed tomography system. The PTU and PTG instruments were used to shape twelve mesial canals each. The canals were scanned after preparation with F2 and F3 instruments of the PTU and PTG systems. The analyzed parameters included the remaining dentin thickness at the apical and cervical levels, root canal volume and untouched canal walls. Data was analyzed for statistical significance by the Friedman and Dunn’s tests. For the comparison of data between groups, the Mann-Whitney test was used. Results In the pre-operative analysis, there were no statistically significant differences between the groups in terms of the area and volume of root canals (P>.05). There was also no statistically significant difference between the systems with respect to root canal volume after use of the F2 and F3 instruments. There was no statistical difference in the dentin thickness at the first apical level between, before and after instrumentation for both systems. At the 3 cervical levels, the PTG maintained centralization of the preparation on the transition between the F2 and F3 instruments, which did not occur with the PTU. Conclusion The Conventional NiTi (PTU) and Controlled Memory NiTi (PTG) instruments displayed comparable capabilities for shaping the straight mesial root canals of mandibular molars, although the PTG was better than the PTU at maintaining the centralization of the shape in the cervical portion.
Journal of Endodontics | 2015
Bruno Carvalho de Vasconcelos; Luciana Maria Arcanjo Frota; Tamara de Abreu Souza; Ricardo Affonso Bernardes; Marco Antonio Hungaro Duarte
INTRODUCTION The objective of the present study was to evaluate ex vivo the maintenance of the apical limit during instrumentation with the Root ZX (J Morita, Tokyo, Japan) and VDW Gold (VDW GbmH, Munich, Germany) hybrid devices in rotary and reciprocating modes and determine the possible function variations of different preparation levels (0.0 mm and -1.0 mm). METHODS Seventy-two human uniradicular mandibular premolars, which had their coronal access performed and their apical foramen (AF) standardized (200 μm) were used. After their randomized division, the root canals were chemically mechanically prepared with #F4 ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) and #R40 Reciproc (VDW GbmH) instruments. At the end of the instrumentation, the last instrument was fixed, and 4.0 mm of the apical portion was worn, permitting the measurement of the distance between the instrument tips and the AF. RESULTS The determined precision values of 0.0 and -1.0 mm were 100% and 33.4% (Root), 100% and 41.6% (VDW Gold with rotary movement) and 100% and 33.3% (VDW Gold with reciprocating movement), respectively, with a margin of ±0.5 mm. No statistical differences were found with respect to the comparisons of every level of preparation. However, significant differences were found when comparing the groups with rotary function at the different levels, with a higher precision for the groups that reached the AF. CONCLUSIONS It was concluded that both devices, independent of the function used, were more efficient in the maintenance of the apical limit when used until the AF; however, such reliability was compromised when -1.0 mm from the apical limit was established.
Brazilian Dental Journal | 2014
Bruno Carvalho de Vasconcelos; Rebeca Bastos Rocha de Araújo; Francisco Cláudio Fernandes Alves e Silva; Suyane Maria Luna-Cruz; Marco Antonio Hungaro Duarte; Carlos Augusto de Oliveira Fernandes
The aim of this study was to compare in vivo the accuracy of two electronic foramen locators (EFLs) based on different operation systems - Root ZX and Propex II. Ten healthy adult patients needing premolar extractions due to orthodontic reasons participated in the study, providing a sample of 17 noncarious, non-restored, vital teeth (n= 24 canals). After coronal access preparation and cervical preflaring and prior to tooth extraction, the root canal length was measured alternating the two EFLs. All measurements were performed with K-files well fitted to the canal diameter at the level that each EFL indicated the apical foramen in their display (APEX or 0.0). The last K-file were fixed in place with cyanoacrylate, the tooth was extracted, and the apical 4 mm of each root were resected to measure the distance between the file tip and the apical foramen. The mean errors based on the absolute values of discrepancies were 0.30 ± 0.29 mm (Root ZX) and 0.32 ± 0.27 mm (Propex II). Analysis by the Wilcoxon test for paired samples showed no statistically significant differences between the electronic canal measurements performed with the EFLs (p=0.587). The apical foramen was accurately located in 75% (Root ZX) and 66.7% (Propex II) of the cases, considering a ±0.5 mm error margin, with no statistically significant difference by the chi-square test. Despite having different measurement mechanisms, both EFLs were capable of locating the apical foramen with high accuracy in vivo. Under the tested clinical conditions, Root ZX and Propex II displayed similar results.
Brazilian Dental Journal | 2015
Parente La; Levin; Rodrigo Ricci Vivan; Ricardo Affonso Bernardes; Duarte Ma; Bruno Carvalho de Vasconcelos
The present study evaluated the efficacy of electronic foramen locators (EFLs) to control root canal working length during rotary instrumentation and to assess possible reliability variations of different working lengths. Forty-eight human mandibular bicuspids were randomly divided in 2 groups according to the used device, Root ZX II (RZX) and Propex II (PRO). They were further subdivided in 2 subgroups according to the root canal preparation level (0.0 and -1.0). Preparation was performed with the Protaper rotary system using a crown-down technique. RZX was employed on its automatic auto-reverse mode (AAR) and PRO was used with the MPAS-10R contra-angle to monitor the preparation. The last used file (F3) was fixed, and the apical portion of the teeth was worn buccolingually, allowing to measure the extent between the file tip and the apical foramen (AF). The precision values of 0.0 mm and -1.0 mm were 100% and 0.0% for RZX, and 100% and 66.7% for PRO, respectively, with a range of ±0.5 mm. Statistical analysis showed no differences between the groups at 0.0 mm. However, at -1.0 mm, RZX showed the poorest results (0.96±0.11 mm), followed by PRO (0.43±0.23 mm). The difference between RZX and PRO was statistically significant. The EFLs were precise in maintaining the working length during rotary preparation when reaching the AF, but when their penetration was limited, both devices showed decreased precision; the RZX AAR failed in all instances.
Journal of Applied Oral Science | 2018
Myrna Maria Arcanjo Frota; Ricardo Affonso Bernardes; Rodrigo Ricci Vivan; Nilton Vivacqua-Gomes; Marco Antonio Hungaro Duarte; Bruno Carvalho de Vasconcelos
Abstract Objective To evaluate the amount of apically extruded debris, percentage of foraminal enlargement and apical foramen (AF) deformation that occurred during root canal preparation with different reciprocation systems: Reciproc, WaveOne (M-Wire), and ProDesign R (Shape Memory Technology Wire) at two different working lengths (WLs): 0.0 and 1.0 mm beyond the AF. Material and methods The AF of 120 root canals in 60 mesial roots of mandibular molars were photographed with stereomicroscope and randomly assigned into four groups: manual, Reciproc (REC), WaveOne (WO), and ProDesign R (PDR); subsequently, they were further subdivided according to the WL (n=15). Teeth were instrumented, coupled to a dual collecting chamber, and then another photograph of each AF was captured. Extrusion was analysed by determining the weight of extruded debris. Each AF diameter was measured in pre- and post-instrumentation images to determine deformation, which was analysed, and afterwards the final format of AFs was classified (circular/oval/deformed). Results We found no significant differences when analysing each system at different WLs. When considering each WL, REC and WO showed highest extrusion values (P<.05); for AF enlargement, differences were observed only for WO, when it was used beyond the AF; differences were observed among M-Wire groups beyond the AF (P<.05). AF deformation was observed in all groups; PDR showed the lowest AF deformation values at both WLs; M-Wire groups showed 50% strain beyond the AF. Conclusion Authors concluded that beyond the apical limit, the alloy and taper are important aspects when considering extrusion and deformation.