Journal of the Acoustical Society of America | 2006

Effects of nonlinear propagation, cavitation, and boiling in lesion formation by high intensity focused ultrasound in a gel phantom

Vera A. Khokhlova; Michael R. Bailey; Justin Reed; Bryan W. Cunitz; Peter J. Kaczkowski; Lawrence A. Crum

The importance of nonlinear acoustic wave propagation and ultrasound-induced cavitation in the acceleration of thermal lesion production by high intensity focused ultrasound was investigated experimentally and theoretically in a transparent protein-containing gel. A numerical model that accounted for nonlinear acoustic propagation was used to simulate experimental conditions. Various exposure regimes with equal total ultrasound energy but variable peak acoustic pressure were studied for single lesions and lesion stripes obtained by moving the transducer. Static overpressure was applied to suppress cavitation. Strong enhancement of lesion production was observed for high amplitude waves and was supported by modeling. Through overpressure experiments it was shown that both nonlinear propagation and cavitation mechanisms participate in accelerating lesion inception and growth. Using B-mode ultrasound, cavitation was observed at normal ambient pressure as weakly enhanced echogenicity in the focal region, but was not detected with overpressure. Formation of tadpole-shaped lesions, shifted toward the transducer, was always observed to be due to boiling. Boiling bubbles were visible in the gel and were evident as strongly echogenic regions in B-mode images. These experiments indicate that nonlinear propagation and cavitation accelerate heating, but no lesion displacement or distortion was observed in the absence of boiling.


The Journal of Urology | 2012

Focused Ultrasound to Expel Calculi From the Kidney

Anup Shah; Jonathan D. Harper; Bryan W. Cunitz; Yak-Nam Wang; Marla Paun; Julianna C. Simon; Wei Lu; Peter J. Kaczkowski; Michael R. Bailey

PURPOSE A persistent stone burden after renal stone treatment may result in future patient morbidity and potentially lead to additional surgery. This problem is particularly common after treatment of lower pole stones. We describe a potential noninvasive therapeutic option using ultrasound waves to create a force sufficient to aid in stone fragment expulsion. MATERIALS AND METHODS Human stones were implanted by retrograde ureteroscopy or antegrade percutaneous access in a live porcine model. The calibrated probe of a system containing ultrasound imaging and focused ultrasound was used to target stones and attempt displacement. To assess for injury an additional 6 kidneys were exposed for 2 minutes each directly to the output used for stone movement. Another 6 kidneys were exposed to more than twice the maximum output used to move stones. Renal tissue was analyzed histologically with hematoxylin and eosin, and nicotinamide adenine dinucleotide staining. RESULTS Stones were moved to the renal pelvis or ureteropelvic junction by less than 2 minutes of exposure. Stone velocity was approximately 1 cm per second. There was no tissue injury when tissue was exposed to the power level used to move stones. Localized thermal coagulation less than 1 cm long was observed in 6 of 7 renal units exposed to the level above that used for ultrasonic propulsion. CONCLUSIONS Transcutaneous ultrasonic propulsion was used to expel calculi effectively and safely from the kidney using a live animal model. This study is the first step toward an office based system to clear residual fragments and toward use as a primary treatment modality in conjunction with medical expulsive therapy for small renal stones.


Proceedings of the National Academy of Sciences of the United States of America | 2014

Ultrasound-guided tissue fractionation by high intensity focused ultrasound in an in vivo porcine liver model

Tatiana D. Khokhlova; Yak-Nam Wang; Julianna C. Simon; Bryan W. Cunitz; Frank Starr; Marla Paun; Lawrence A. Crum; Michael R. Bailey; Vera A. Khokhlova

Significance High intensity focused ultrasound (HIFU) therapy is a promising, clinically adopted method of noninvasive tissue ablation used to treat both benign and malignant conditions. This work presents, to our knowledge, the first in vivo validation of a previously developed HIFU-based method that allows for noninvasive fractionation of targeted tissue into subcellular debris—boiling histotripsy—in a large animal model. While fractionating the targeted soft tissue, boiling histotripsy is shown to spare the adjacent connective tissue structures such as blood vessels. The process can be readily targeted and monitored by B-mode ultrasound. The resulting tissue debris are liquid, which provides a potential clinical benefit over thermal ablation in the treatment of tumors that exert uncomfortable pressure on surrounding tissues. The clinical use of high intensity focused ultrasound (HIFU) therapy for noninvasive tissue ablation has been recently gaining momentum. In HIFU, ultrasound energy from an extracorporeal source is focused within the body to ablate tissue at the focus while leaving the surrounding organs and tissues unaffected. Most HIFU therapies are designed to use heating effects resulting from the absorption of ultrasound by tissue to create a thermally coagulated treatment volume. Although this approach is often successful, it has its limitations, such as the heat sink effect caused by the presence of a large blood vessel near the treatment area or heating of the ribs in the transcostal applications. HIFU-induced bubbles provide an alternative means to destroy the target tissue by mechanical disruption or, at its extreme, local fractionation of tissue within the focal region. Here, we demonstrate the feasibility of a recently developed approach to HIFU-induced ultrasound-guided tissue fractionation in an in vivo pig model. In this approach, termed boiling histotripsy, a millimeter-sized boiling bubble is generated by ultrasound and further interacts with the ultrasound field to fractionate porcine liver tissue into subcellular debris without inducing further thermal effects. Tissue selectivity, demonstrated by boiling histotripsy, allows for the treatment of tissue immediately adjacent to major blood vessels and other connective tissue structures. Furthermore, boiling histotripsy would benefit the clinical applications, in which it is important to accelerate resorption or passage of the ablated tissue volume, diminish pressure on the surrounding organs that causes discomfort, or insert openings between tissues.


The Journal of Urology | 2015

Fragmentation of Urinary Calculi In Vitro by Burst Wave Lithotripsy

Adam D. Maxwell; Bryan W. Cunitz; Wayne Kreider; Oleg A. Sapozhnikov; Ryan S. Hsi; Jonathan D. Harper; Michael R. Bailey; Mathew D. Sorensen

PURPOSE We developed a new method of lithotripsy that uses short, broadly focused bursts of ultrasound rather than shock waves to fragment stones. We investigated the characteristics of stone comminution by burst wave lithotripsy in vitro. MATERIALS AND METHODS Artificial and natural stones (mean ± SD size 8.2 ± 3.0 mm, range 5 to 15) were treated with ultrasound bursts using a focused transducer in a water bath. Stones were exposed to bursts with focal pressure amplitude of 6.5 MPa or less at a 200 Hz burst repetition rate until completely fragmented. Ultrasound frequencies of 170, 285 and 800 kHz were applied using 3 transducers, respectively. Time to fragmentation for each stone type was recorded and fragment size distribution was measured by sieving. RESULTS Stones exposed to ultrasound bursts were fragmented at focal pressure amplitudes of 2.8 MPa or greater at 170 kHz. Fractures appeared along the stone surface, resulting in fragments that separated at the surface nearest to the transducer until the stone was disintegrated. All natural and artificial stones were fragmented at the highest focal pressure of 6.5 MPa with a mean treatment duration of 36 seconds for uric acid stones to 14.7 minutes for cystine stones. At a frequency of 170 kHz the largest artificial stone fragments were less than 4 mm. Exposure at 285 and 800 kHz produced only fragments less than 2 mm and less than 1 mm, respectively. CONCLUSIONS Stone comminution with burst wave lithotripsy is feasible as a potential noninvasive treatment method for nephrolithiasis. Adjusting the fundamental ultrasound frequency allows for stone fragment size to be controlled.


The Journal of Urology | 2013

Focused Ultrasound to Expel Calculi from the Kidney: Safety and Efficacy of a Clinical Prototype Device

Jonathan D. Harper; Mathew D. Sorensen; Bryan W. Cunitz; Yak-Nam Wang; Julianna C. Simon; Frank Starr; Marla Paun; Barbrina Dunmire; H. Denny Liggitt; Andrew P. Evan; James A. McAteer; Ryan S. Hsi; Michael R. Bailey

PURPOSE Focused ultrasound has the potential to expel small stones or residual stone fragments from the kidney, or move obstructing stones to a nonobstructing location. We evaluated the efficacy and safety of ultrasonic propulsion in a live porcine model. MATERIALS AND METHODS Calcium oxalate monohydrate kidney stones and laboratory model stones (2 to 8 mm) were ureteroscopically implanted in the renal pelvicalyceal system of 12 kidneys in a total of 8 domestic swine. Transcutaneous ultrasonic propulsion was performed using an HDI C5-2 imaging transducer (ATL/Philips, Bothell, Washington) and the Verasonics® diagnostic ultrasound platform. Successful stone relocation was defined as stone movement from the calyx to the renal pelvis, ureteropelvic junction or proximal ureter. Efficacy and procedure time was determined. Three blinded experts evaluated histological injury to the kidney in the control, sham treatment and treatment arms. RESULTS All 26 stones were observed to move during treatment and 17 (65%) were relocated successfully to the renal pelvis (3), ureteropelvic junction (2) or ureter (12). Average ± SD successful procedure time was 14 ± 8 minutes and a mean of 23 ± 16 ultrasound bursts, each about 1 second in duration, were required. There was no evidence of gross or histological injury to the renal parenchyma in kidneys exposed to 20 bursts (1 second in duration at 33-second intervals) at the same output (2,400 W/cm(2)) used to push stones. CONCLUSIONS Noninvasive transcutaneous ultrasonic propulsion is a safe, effective and time efficient means to relocate calyceal stones to the renal pelvis, ureteropelvic junction or ureter. This technology holds promise as a useful adjunct to surgical management for renal calculi.


Journal of Endourology | 2013

Focused Ultrasonic Propulsion of Kidney Stones: Review and Update of Preclinical Technology

Mathew D. Sorensen; Michael R. Bailey; Ryan S. Hsi; Bryan W. Cunitz; Julianna C. Simon; Yak-Nam Wang; Barbrina Dunmire; Marla Paun; Frank Starr; Wei Lu; Andrew P. Evan; Jonathan D. Harper

INTRODUCTION A noninvasive tool to reposition kidney stones could have significant impact in the management of stone disease. Our research group has developed a noninvasive transcutaneous ultrasound device. A review and update of the current status of this technology is provided. DISCUSSION OF TECHNOLOGY: Stone propulsion is achieved through short bursts of focused, ultrasonic pulses. The initial system consisted of an eight-element annular array transducer, computer, and separate ultrasound imager. In the current generation, imaging and therapy are completed with one ultrasound system and a commercial probe. This generation allows real-time ultrasound imaging, targeting, and propulsion. Safety and effectiveness for the relocation of calyceal stones have been demonstrated in the porcine model. ROLE IN ENDOUROLOGY: This technology may have applications in repositioning stones as an adjunct to lithotripsy, facilitating clearance of residual fragments after lithotripsy, expelling de novo stones, and potentially repositioning obstructing stones. Human trials are in preparation.


The Journal of Urology | 2016

First in Human Clinical Trial of Ultrasonic Propulsion of Kidney Stones

Jonathan D. Harper; Bryan W. Cunitz; Barbrina Dunmire; Franklin Lee; Mathew D. Sorensen; Ryan S. Hsi; Jeff Thiel; Hunter Wessells; James E. Lingeman; Michael R. Bailey

PURPOSE Ultrasonic propulsion is a new technology using focused ultrasound energy applied transcutaneously to reposition kidney stones. We report what are to our knowledge the findings from the first human investigational trial of ultrasonic propulsion toward the applications of expelling small stones and dislodging large obstructing stones. MATERIALS AND METHODS Subjects underwent ultrasonic propulsion while awake without sedation in clinic, or during ureteroscopy while anesthetized. Ultrasound and a pain questionnaire were completed before, during and after propulsion. The primary outcome was to reposition stones in the collecting system. Secondary outcomes included safety, controllable movement of stones and movement of stones less than 5 mm and 5 mm or greater. Adverse events were assessed weekly for 3 weeks. RESULTS Kidney stones were repositioned in 14 of 15 subjects. Of the 43 targets 28 (65%) showed some level of movement while 13 (30%) were displaced greater than 3 mm to a new location. Discomfort during the procedure was rare, mild, brief and self-limited. Stones were moved in a controlled direction with more than 30 fragments passed by 4 of the 6 subjects who had previously undergone a lithotripsy procedure. The largest stone moved was 10 mm. One patient experienced pain relief during treatment of a large stone at the ureteropelvic junction. In 4 subjects a seemingly large stone was determined to be a cluster of small passable stones after they were moved. CONCLUSIONS Ultrasonic propulsion was able to successfully reposition stones and facilitate the passage of fragments in humans. No adverse events were associated with the investigational procedure.


The Journal of Urology | 2016

Use of the Acoustic Shadow Width to Determine Kidney Stone Size with Ultrasound

Barbrina Dunmire; Jonathan D. Harper; Bryan W. Cunitz; Franklin Lee; Ryan S. Hsi; Ziyue Liu; Michael R. Bailey; Mathew D. Sorensen

PURPOSE Ultrasound is known to overestimate kidney stone size. We explored measuring the acoustic shadow behind kidney stones combined with different ultrasound imaging modalities to improve stone sizing accuracy. MATERIALS AND METHODS A total of 45 calcium oxalate monohydrate stones were imaged in vitro at 3 different depths with the 3 different ultrasound imaging modalities of conventional ray line, spatial compound and harmonic imaging. The width of the stone and the width of the acoustic shadow were measured by 4 operators blinded to the true size of the stone. RESULTS Average error between the measured and true stone width was 1.4 ± 0.8 mm, 1.7 ± 0.9 mm, 0.9 ± 0.8 mm for ray line, spatial compound and harmonic imaging, respectively. Average error between the shadow width and true stone width was 0.2 ± 0.7 mm, 0.4 ± 0.7 mm and 0.0 ± 0.8 mm for ray line, spatial compound and harmonic imaging, respectively. Sizing error based on the stone width worsened with greater depth (p <0.001) while the sizing error based on the shadow width was independent of depth. CONCLUSIONS Shadow width was a more accurate measure of true stone size than a direct measurement of the stone in the ultrasound image (p <0.0001). The ultrasound imaging modality also impacted the measurement accuracy. All methods performed similarly for shadow size while harmonic imaging was the most accurate stone size modality. Overall 78% of the shadow sizes were accurate to within 1 mm, which is similar to the resolution obtained with clinical computerized tomography.


Journal of Endourology | 2015

Tools to improve the accuracy of kidney stone sizing with ultrasound.

Barbrina Dunmire; Franklin Lee; Ryan S. Hsi; Bryan W. Cunitz; Marla Paun; Michael R. Bailey; Mathew D. Sorensen; Jonathan D. Harper

PURPOSE Ultrasound (US) overestimates stone size when compared with CT. The purpose of this work was to evaluate the overestimation of stone size with US in an in vitro water bath model and investigate methods to reduce overestimation. MATERIALS AND METHODS Ten human stones (3-12 mm) were measured using B-mode (brightness mode) US by a sonographer blinded to the true stone size. Images were captured and compared using both a commercial US machine and software-based research US device. Image gain was adjusted between moderate and high stone intensities, and the transducer-to-stone depth was varied from 6 to 10 cm. A computerized stone-sizing program was developed to outline the stone width based on a grayscale intensity threshold. RESULTS Overestimation with the commercial device increased with both gain and depth. Average overestimation at moderate and high gain was 1.9±0.8 and 2.1±0.9 mm, respectively (p=0.6). Overestimation increased an average of 22% with an every 2-cm increase in depth (p=0.02). Overestimation using the research device was 1.5±0.9 mm and did not vary with depth (p=0.28). Overestimation could be reduced to 0.02±1.1 mm (p<0.001) with the computerized stone-sizing program. However, a standardized threshold consistent across depth, system, or system settings could not be resolved. CONCLUSION Stone size is consistently overestimated with US. Overestimation increased with increasing depth and gain using the commercial machine. Overestimation was reduced and did not vary with depth, using the software-based US device. The computerized stone-sizing program shows the potential to reduce overestimation by implementing a grayscale intensity threshold for defining the stone size. More work is needed to standardize the approach, but if successful, such an approach could significantly improve stone-sizing accuracy and lead to automation of stone sizing.


Journal of Endourology | 2016

Stone-mode ultrasound for determining renal stone size

Philip May; Yasser Haider; Barbrina Dunmire; Bryan W. Cunitz; Jeff Thiel; Ziyue Liu; Matthew Bruce; Michael R. Bailey; Mathew D. Sorensen; Jonathan D. Harper

PURPOSE The purpose of this study was to measure the accuracy of stone-specific algorithms (S-mode) and the posterior acoustic shadow for determining kidney stone size with ultrasound (US) in vivo. MATERIALS AND METHODS Thirty-four subjects with 115 renal stones were prospectively recruited and scanned with S-mode on a research US system. S-mode is gray-scale US adjusted to enhanced stone contrast and resolution by minimizing compression and averaging, and increasing line density and frequency. Stone and shadow width were compared with a recent CT scan and, in 5 subjects with 18 stones, S-mode was compared with a clinical US system. RESULTS Overall, 84% of stones identified on CT were detected on S-mode and 66% of these shadowed. Seventy-three percent of the stone measurements and 85% of the shadow measurements were within 2 mm of the size on CT. A posterior acoustic shadow was present in 89% of stones over 5 mm versus 53% of stones under 5 mm. S-mode visualized 78% of stones, versus 61% for the clinical system. S-mode stone and shadow measurements differed from CT by 1.6 ± 1.0 mm and 0.8 ± 0.6 mm, respectively, compared with 2.0 ± 1.5 mm and 1.6 ± 1.0 mm for the clinical system. CONCLUSIONS S-mode offers improved visualization and sizing of renal stones. With S-mode, sizing of the stone itself and the posterior acoustic shadow were similarly accurate. Stones that do not shadow are most likely <5 mm and small enough to pass spontaneously.

Collaboration


Dive into the Bryan W. Cunitz's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Wayne Kreider

University of Washington

View shared research outputs
Top Co-Authors

Avatar

Yak-Nam Wang

University of Washington

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ryan S. Hsi

University of Washington

View shared research outputs
Researchain Logo
Decentralizing Knowledge