Burak Hünük
Marmara University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Burak Hünük.
Europace | 2015
Giuseppe Ciconte; Giannis Baltogiannis; Carlo de Asmundis; Juan Sieira; Giulio Conte; Giacomo Di Giovanni; Yukio Saitoh; Ghazala Irfan; Giacomo Mugnai; Burak Hünük; Gian-Battista Chierchia; Pedro Brugada
AIMS To assess the 1 year efficacy of pulmonary vein isolation (PVI) as index procedure for persistent atrial fibrillation (PersAF) comparing conventional radiofrequency irrigated-tip catheter ablation (RFCA) using contact-force technology and ablation using the second-generation cryoballoon (CB-AdvA). METHODS AND RESULTS One hundred consecutive patients (74 male, 74%; mean age 62.4 ± 9.6 years) with drug-refractory PersAF undergoing PVI using RFCA and CB-AdvA were enrolled. Follow-up was based on outpatient clinic visits including Holter-electrocardiograms. Recurrence of atrial tachyarrhythmias (ATas) was defined as a symptomatic or documented episode >30 s. Among 100 patients, 50 underwent RFCA whereas 50 CB-AdvA. Mean procedure and fluoroscopy times were 90.5 ± 41.7 vs. 140.2 ± 46.9 min and 14.5 ± 6.6 vs. 19.8 ± 6.8 min in the CB-Adv and in the RFCA group, respectively (P < 0.01). At 1 year follow-up, after a 3 months blanking period (BP), freedom from ATas off-drugs after a single procedure was 60% (28/50 patients) in the CB-Adv and 56% (27/50 patients) in the RFCA group (P = 0.71). Multivariate analysis demonstrated that PersAF duration (P = 0.01) and relapses during BP (P = 0.02) were independent predictors of ATa recurrences following the index procedure. CONCLUSION Freedom from ATas following PersAF ablation with RFCA and CB-Adv is comparable at 1 year follow-up after a single procedure. Ablation with the CB-Adv is associated with shorter procedure time and radiation exposure as compared with RFCA. Atrial tachyarrhythmias occurrence during BP and longer time of PersAF seem to be significant predictors of arrhythmia recurrences after the index procedure.
Circulation-arrhythmia and Electrophysiology | 2015
Giuseppe Ciconte; Giacomo Mugnai; Juan Sieira; Vedran Velagic; Yukio Saitoh; Ghazala Irfan; Burak Hünük; Erwin Ströker; Giulio Conte; Giacomo Di Giovanni; Giannis Baltogiannis; Kristel Wauters; Pedro Brugada; Carlo de Asmundis; Gian-Battista Chierchia
Background—The second-generation cryoballoon is effective in achieving acute pulmonary vein isolation (PVI) and favorable clinical outcome. To date, no data are available on factors affecting late PV reconnection after second-generation cryoballoon ablation. Methods and Results—A total of 29 consecutive patients (25 male, 86.2%; mean age 57.8±13.8 years) underwent a repeat procedure, after a mean 11.6±4.5 months (range, 3.5–19.7 months), after index ablation using the 28-mm second-generation cryoballoon. All repeat ablations were performed using a 3-dimensional electroanatomical mapping system. Among all 115 PVs, including 1 left common ostiums (LCOs), 25 (21.7%) showed a PV reconnection in 20 patients (1.25 per patient). Persistent PVI could be documented in 90 of 115 PVs (78.2%). In 9 of 29 patients (31%), all PVs were electrically isolated. In the multivariable analysis, time to PVI (P=0.03) and failure to achieve −40°C within 60 s (P=0.05) independently predicted late PV reconnection. At receiver-operator curve analysis, time to PVI <60 s identified the absence of PV reconduction (sensitivity, 86.7%; specificity, 86.2%; positive predictive value, 59.1%; and negative predictive value, 96.4%; area under the curve, 0.85; confidence interval, 0.73–0.97; P<0.001). Conclusions—The rate of late PV reconnection after second-generation cryoballoon ablation is low (1.25 PVs/patient). Faster time to isolation and achievement of −40°C within 60 s independently predict durable PVI. In addition, 60-s cut-off for time to PVI indicates persistent isolation with 96.4% negative predictive value. These parameters might guide the operator whether to perform further applications to ensure a long-lasting PVI.
Heart Rhythm | 2015
Giacomo Mugnai; Carlo de Asmundis; Giuseppe Ciconte; Ghazala Irfan; Yukio Saitoh; Vedran Velagic; Erwin Ströker; Kristel Wauters; Burak Hünük; Pedro Brugada; Gian-Battista Chierchia
BACKGROUND The second-generation cryoballoon Advance (CB-A) recently launched on the market has technical modifications designed to significantly improve procedural outcome with respect to the first-generation device. OBJECTIVE The purpose of this study was to evaluate the overall incidence of complications in a large sample of patients having undergone pulmonary vein (PV) isolation with CB-A technology. METHODS All consecutive patients who underwent PV isolation procedures using CB-A technology between June 2012 and February 2015 were considered. Exclusion criteria were presence of an intracavitary thrombus, uncontrolled heart failure, moderate or severe valvular disease, left atrial diameter ≥55 mm, and contraindications to general anesthesia. RESULTS During the study period, 500 consecutive patients (67% male, age 57.6 ± 12.9 years) were enrolled. Major complications occurred in 10 patients (2.0%): vascular complications at the puncture site in 6 (1.2%), and thromboembolic events, cardiac tamponade, persisting phrenic nerve palsy, and retroperitoneal hematoma all occurred in a single patient respectively (0.2%). Phrenic nerve palsy occurred in 36 patients (7.2%) and did not revert in only 1 patient at final follow-up of 20 months. No deaths related to the procedure occurred. No predictors of major complication were found. CONCLUSION The present findings highlight that PV isolation using CB-A technology can be safely performed with a low incidence of adverse events. The incidence of major complications after atrial fibrillation ablation procedures using CB-A technology was 2% in our study. The most frequent complication consisted of vascular complications at the puncture site. No deaths related to the procedure occurred.
Europace | 2016
Giuseppe Ciconte; Vedran Velagic; Giacomo Mugnai; Yukio Saitoh; Ghazala Irfan; Burak Hünük; Erwin Ströker; Giulio Conte; Juan Sieira; Giacomo Di Giovanni; Giannis Baltogiannis; Pedro Brugada; Carlo de Asmundis; Gian-Battista Chierchia
AIMS To assess the incidence of late pulmonary vein (PV) reconnection following index PV isolation (PVI) procedure initially achieved with radiofrequency contact-force catheter ablation (CFCA) and second-generation cryoballoon ablation (CB-AdvA). METHODS AND RESULTS A total of 56 consecutive patients (41 male, 73.2%; mean age 60.8 ± 11.8 years) underwent a repeat ablation because of recurrent atrial tachyarrhythmias (ATas) after index PVI achieved with CFCA (30 patients) or CB-AdvA (26 patients). All repeat procedures were performed by the means of CFCA. In the CFCA group, among 119 PVs, 43 (36.1%) showed conduction gaps in 24 patients (1.8 per patient), whereas in the CB-AdvA group among 103 veins, 21 (20.4%) showed a PV reconnection in 18 patients (1.2 per patient) (P = 0.01). The left superior pulmonary vein was less frequently reconnected following CB-AdvA when compared with CFCA (2/25, 8% vs. 11/29, 37.9%; P = 0.01). In the CFCA group, the mean CF per-vein was lower in reconnecting veins when compared with those persistently isolated (10.9 ± 2.7 vs. 18.6 ± 3.1 g; P < 0.001). In the CB-AdvA group, late PV reconnection was associated with warmer nadir temperature (-48.9 ± 5.1 vs. -51.2 ± 4.7°C; P = 0.05) and longer time-to-isolation (71.1 ± 20.2 vs. 50.2 ± 32.9 s; P = 0.03). CONCLUSION The rate of late PV reconnection is significantly lower following CB-AdvA when compared with CFCA as index procedure. Lower CF values and warmer nadir temperature with longer time to effect were more frequently associated with PV reconnections in the setting of CFCA and CB-AdvA.
International Journal of Cardiology | 2015
Giacomo Mugnai; Ghazala Irfan; Carlo de Asmundis; Giuseppe Ciconte; Yukio Saitoh; Burak Hünük; Vedran Velagic; Erwin Ströker; Paolo Rossi; Lucio Capulzini; Pedro Brugada; Gian-Battista Chierchia
BACKGROUND The aim of this study was to assess the overall incidence of complications in a large sample of consecutive patients having undergone pulmonary vein (PV) isolation, evaluating also the rate of complications in radiofrequency (RF) and cryoballoon (CB) ablation technologies. METHODS AND RESULTS From January 2008 to December 2014, 1352 consecutive PV isolation procedures were performed in our center; a total amount of 1233 AF ablation procedures fulfilling inclusion criteria was finally taken into consideration for our analysis. A total of 642 procedures were performed using RF ablation technology and 591 using CB system. Serious adverse events occurred in 36 procedures (2.9%): specifically, vascular complications in 14 (1.1%); cardiac tamponade in 13 (1.0%); a thromboembolic event in 4 (0.3%); and atrial-esophageal fistula, PV intramural hematoma, retroperitoneal hematoma, pleural hematoma and persisting phrenic nerve palsy all occurred in 1 patient individually (0.1%). No deaths related to the procedure occurred. The complication rate did not significantly differ in the RF and CB groups (respectively, 3.6% vs 2.2%; p=0.1). Complication rates considerably decreased over the study period from 4.67% in 2008 to 1.55% in 2014. Interestingly, each 1-point increase in the CHA2DS2-VASc score was found to increase by 51% the likelihood of a serious adverse event. CONCLUSIONS The incidence of serious adverse events following AF ablation procedures was 2.9%. Vascular complications were the most frequent complication followed by tamponade and thromboembolic events. The rate of complications considerably decreased over time. CHA2DS2-VASc score was found to be associated with higher risk of complications.
Europace | 2016
Giacomo Mugnai; Carlo de Asmundis; Vedran Velagic; Burak Hünük; Erwin Ströker; Kristel Wauters; Ghazala Irfan; Ingrid Overeinder; Ebru Hacioglu; Jaime Hernandez-Ojeda; Jan Poelaert; Christian Verborgh; Gaetano Paparella; Pedro Brugada; Gian-Battista Chierchia
AIMS The present study sought to analyse the relationship between the temperature drop during the cryoenergy application and the occurrence of phrenic nerve injury (PNI) in a large cohort of patients having undergone second-generation cryoballoon ablation (CB-A). METHODS AND RESULTS The first 550 consecutive patients having undergone CB-A for atrial fibrillation were enrolled. Attained temperatures at 20, 30, 40, and 60 s during cryoablation in the right-sided pulmonary veins (PVs) were collected. Diagnosis of PNI was made if reduced motility or paralysis of the hemidiaphragm was detected. The incidence of PNI in the study population was 7.3% (40/550); among them, only four (0.7%) did not resolve until discharge and one (0.2%) still persisted at 23 months. Patients with PNI exhibited significantly lower temperatures at 20, 30, and 40 s after the beginning of the cryoapplication in the right superior PV (RSPV) (P = 0.006, P = 0.003, and P = 0.003, respectively). The temperature drop expressed as Δ temperature/Δ time was also significantly higher in patients with PNI. Low temperature during the early phases of the freezing cycle (less than -38°C at 40 s) predicted PNI with a sensitivity of 80.5%, a specificity of 77%, and a negative predictive value of 97.9%. Among patients with a fast temperature drop during RSPV ablation, an RSPV diameter >23.55 × 17.95 mm significantly predicted PNI occurrence. CONCLUSION The analysis of the temperature course within the first 40 s after the initiation of the freezing cycle showed that the temperature dropped significantly faster in patients with PNI during ablation in the RSPV.
Heart Rhythm | 2016
Erwin Ströker; Carlo de Asmundis; Yukio Saitoh; Vedran Velagic; Giacomo Mugnai; Ghazala Irfan; Burak Hünük; Kaoru Tanaka; Dries Belsack; Ronald Buyl; Pedro Brugada; Gian-Battista Chierchia
BACKGROUND Phrenic nerve injury (PNI) is the most frequently observed complication during pulmonary vein (PV) isolation using the second-generation cryoballoon. OBJECTIVE The purpose of this study was to analyze anatomic predictors based on preprocedural computed tomographic imaging data. METHODS Forty-one patients with PNI during the procedure and 123 age-, gender-, and body mass index-matched controls were included. A total of 343 right PVs were evaluated for axial/coronal orientation, ostial diameters with cross-sectional area, ovality index, and branching pattern. External angle between the right superior pulmonary vein (RSPV) and the anterolateral wall of the left atrium (LA) was measured (RSPV-LA angle). Distance from this vertex to the superior vena cava (SVC) was considered the RSPV-SVC distance. RESULTS For the RSPV, more anterosuperior orientation, larger dimensions, shorter RSPV-SVC distance, and more obtuse RSPV-LA angle (all P <.001) were associated with PNI on univariate analysis. Independent variables after multivariable analysis were RSPV-LA angle (odds ratio 1.03 per degree, 95% confidence interval 1.01-1.04, P <.001) and RSPV area (odds ratio 1.2 per mm², 95% confidence interval 1.1-1.3, P <.001), with a cutoff value ≥141° for RSPV-LA angle (91% sensitivity, 85% specificity) and ≥275 mm² for RSPV area (88% sensitivity, 85% specificity). RIPV area was an independent predictor for PNI at RIPV. A right-sided long common trunk was seen exclusively in 3 patients in the PNI group. CONCLUSION Preprocedural anatomic assessment of right PVs is useful in evaluating the risk of PNI. Ostial vein area and external RSPV-LA angle measurement showed excellent predictive value for PNI at the RSPV.
Europace | 2016
Gian-Battista Chierchia; Giacomo Mugnai; Erwin Ströker; Vedran Velagic; Burak Hünük; Darragh Moran; Ebru Hacioglu; Jan Poelaert; Christian Verborgh; Vincent Umbrain; Stefan Beckers; Diego Ruggiero; Pedro Brugada; Carlo de Asmundis
AIMS The third-generation Cryoballoon Advance Short-tip (CB-ST) has been designed with a 40% shortened tip length compared with the former second-generation CB Advance device. Ideally, a shorter tip should permit an improved visualization of real-time (RT) recordings in the pulmonary vein (PV) due to a more proximal positioning of the inner lumen mapping catheter. In the present study, we sought to analyse the rate of visualization of RT recordings in our first series of patients with the CB-ST device. METHODS AND RESULTS All consecutive patients having undergone CB ablation using CB-ST technology were analysed. Exclusion criteria were the presence of an intracavitary thrombus, uncontrolled heart failure, moderate or severe valvular disease, and contraindications to general anaesthesia. A total of 60 consecutive patients (60.5 ± 11.2 years, 62% males) were evaluated. Real-time recordings were detected in 209 of 240 PVs (87.1%). Specifically, RT recordings could be visualized in 55 left superior PVs (91.7%), 51 left inferior PVs (85.0%), 53 right superior PVs (88.3%), and 50 right inferior PVs (83.3). CONCLUSION The rate of visualization of RT recordings is significantly high during third-generation CB-ST ablation. Real-time recordings can be visualized in ∼87.1% of veins with this novel cryoballoon.
Europace | 2016
Yukio Saitoh; Erwin Ströker; Ghazala Irfan; Giacomo Mugnai; Giuseppe Ciconte; Burak Hünük; Vedran Velagic; Ingrid Overeinder; Kaoru Tanaka; Pedro Brugada; Carlo de Asmundis; Gian-Battista Chierchia
AIMS Phrenic nerve injury (PNI) is the most frequently observed complication during pulmonary vein isolation procedure using the second-generation cryoballoon (CB). Our objective was to analyse the correlation between the fluoroscopic position of the 28 mm CB during ablation in the right superior pulmonary vein (RSPV) and the occurrence of PNI. METHODS AND RESULTS A total of 165 patients having undergone the large 28 mm CB ablation were retrospectively reviewed. Positioning of the CB relative to the cardiac silhouette was classified under fluoroscopic guidance in antero-posterior projection during RSPV ablation. Regarding the lower half of the balloon, CB positioning was defined as follows: (A) completely inside the cardiac shadow; (B1) <1/3 outside the cardiac shadow; and (B2) ≥1/3 outside the cardiac shadow. Phrenic nerve injury occurred in 9.7% (16/165) during ablation in the RSPV. The occurrence of PNI was 0.9, 10.6, and 90.1% in positions A, B1, and B2, respectively (A vs. B1, P = 0.01; B1 vs. B2, P < 0.0001). Among other pre-procedural and procedural variables, the B2 position was the strongest independent determinant for predicting PNI at RSPV (P = 0.001, odds ratio: 119.9; 95% confidence interval: 11.6-1234.7) after multivariable analysis. CONCLUSION The incidence of PNI at the RSPV significantly increased in case of more distal positioning of the CB relative to the cardiac shadow. This simple and straightforward intra-procedural indicator might prone the operators to attempt occluding the RPSV more proximally in order to avoid PNI.
Journal of Electrocardiology | 2014
Erdal Durmus; Burak Hünük; Okan Erdogan
BACKGROUND We aimed to investigate the correlation between ECG QRS voltage changes, N-terminal pro-B-type natriuretic peptide (NT-proBNP) levels and clinical improvement in decompensated heart failure (DHF). METHODS AND RESULTS DHF patients (n=56) with a mean age of 67.5±12.6 years showed limb QRS amplitude increase and NT-proBNP level decrease with clinical improvement (p<0.001). Significant correlation was found between percent changes (Δ%) in body weight and Δ% in QRS voltages of aVR, aVF, DII, ΣQRSI+II and ΣQRS (all limb-leads) (r = -0.40; r = -0.35; r = -0.32; r = -0.30; r = -0.30 respectively, p<0.05). No correlation was found between Δ% in NT-proBNP and body weight (r = -0.23, p=0.09). Δ% NT-proBNP was correlated with Δ% QRS voltage only in aVR (r = -0.312, p=0.019). In ROC analysis, ≥0.5 mm increase in aVR QRS voltage was found to predict ≥5 kg weight loss with a sensitivity of 74% and specificity of 62% (p=0.013, AUC: 0.699). CONCLUSIONS Increase in QRS voltages especially in aVR was found to be more sensitive than NT-proBNP to predict clinical improvement in DHF.