Byeong-Ung Hwang
Sungkyunkwan University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Byeong-Ung Hwang.
ACS Nano | 2015
Eun Roh; Byeong-Ung Hwang; Do-Il Kim; Bo-Yeong Kim; Nae-Eung Lee
UNLABELLED Interactivity between humans and smart systems, including wearable, body-attachable, or implantable platforms, can be enhanced by realization of multifunctional human-machine interfaces, where a variety of sensors collect information about the surrounding environment, intentions, or physiological conditions of the human to which they are attached. Here, we describe a stretchable, transparent, ultrasensitive, and patchable strain sensor that is made of a novel sandwich-like stacked piezoresisitive nanohybrid film of single-wall carbon nanotubes (SWCNTs) and a conductive elastomeric composite of polyurethane (PU)-poly(3,4-ethylenedioxythiophene) polystyrenesulfonate ( PEDOT PSS). This sensor, which can detect small strains on human skin, was created using environmentally benign water-based solution processing. We attributed the tunability of strain sensitivity (i.e., gauge factor), stability, and optical transparency to enhanced formation of percolating networks between conductive SWCNTs and PEDOT phases at interfaces in the stacked PU-PEDOT:PSS/SWCNT/PU-PEDOT:PSS structure. The mechanical stability, high stretchability of up to 100%, optical transparency of 62%, and gauge factor of 62 suggested that when attached to the skin of the face, this sensor would be able to detect small strains induced by emotional expressions such as laughing and crying, as well as eye movement, and we confirmed this experimentally.
Advanced Materials | 2014
Nguyen Thanh Tien; Sanghun Jeon; Do-Il Kim; Tran Quang Trung; Mi Jang; Byeong-Ung Hwang; Kyung-Eun Byun; Jihyun Bae; Eunha Lee; Jeffrey B.-H. Tok; Zhenan Bao; Nae-Eung Lee; Jong-Jin Park
Diverse signals generated from the sensing elements embedded in flexible electronic skins (e-skins) are typically interfered by strain energy generated through processes such as touching, bending, stretching or twisting. Herein, we demonstrate a flexible bimodal sensor that can separate a target signal from the signal by mechanical strain through the integration of a multi-stimuli responsive gate dielectric and semiconductor channel into the single field-effect transistor (FET) platform.
ACS Nano | 2015
Byeong-Ung Hwang; Ju-Hyuck Lee; Tran Quang Trung; Eun Roh; Do-Il Kim; Sang-Woo Kim; Nae-Eung Lee
Monitoring of human activities can provide clinically relevant information pertaining to disease diagnostics, preventive medicine, care for patients with chronic diseases, rehabilitation, and prosthetics. The recognition of strains on human skin, induced by subtle movements of muscles in the internal organs, such as the esophagus and trachea, and the motion of joints, was demonstrated using a self-powered patchable strain sensor platform, composed on multifunctional nanocomposites of low-density silver nanowires with a conductive elastomer of poly(3,4-ethylenedioxythiophene):polystyrenesulfonate/polyurethane, with high sensitivity, stretchability, and optical transparency. The ultra-low-power consumption of the sensor, integrated with both a supercapacitor and a triboelectric nanogenerator into a single transparent stretchable platform based on the same nanocomposites, results in a self-powered monitoring system for skin strain. The capability of the sensor to recognize a wide range of strain on skin has the potential for use in new areas of invisible stretchable electronics for human monitoring. A new type of transparent, stretchable, and ultrasensitive strain sensor based on a AgNW/PEDOT:PSS/PU nanocomposite was developed. The concept of a self-powered patchable sensor system integrated with a supercapacitor and a triboelectric nanogenerator that can be used universally as an autonomous invisible sensor system was used to detect the wide range of strain on human skin.
Advanced Materials | 2016
Tran Quang Trung; Subramaniyan Ramasundaram; Byeong-Ung Hwang; Nae-Eung Lee
A transparent stretchable (TS) gated sensor array with high optical transparency, conformality, and high stretchability of up to 70% is demonstrated. The TS-gated sensor array has high responsivity to temperature changes in objects and human skin. This unprecedented TS-gated sensor array, as well as the integrated platform of the TS-gated sensor with a transparent and stretchable strain sensor, show great potential for application to wearable skin electronics for recognition of human activity.
Small | 2015
Vinh Quang Dang; Tran Quang Trung; Do-Il Kim; Le Thai Duy; Byeong-Ung Hwang; Doo-Won Lee; Bo-Yeong Kim; Le Duc Toan; Nae-Eung Lee
Ultraviolet (UV) photodetectors based on ZnO nanostructure/graphene (Gr) hybrid-channel field-effect transistors (FETs) are investigated under illumination at various incident photon intensities and wavelengths. The time-dependent behaviors of hybrid-channel FETs reveal a high sensitivity and selectivity toward the near-UV region at the wavelength of 365 nm. The devices can operate at low voltage and show excellent selectivity, high responsivity (RI ), and high photoconductive gain (G). The change in the transfer characteristics of hybrid-channel FETs under UV light illumination allows to detect both photovoltage and photocurrent. The shift of the Dirac point (V Dirac ) observed during UV exposure leads to a clearer explanation of the response mechanism and carrier transport properties of Gr, and this phenomenon permits the calculation of electron concentration per UV power density transferred from ZnO nanorods and ZnO nanoparticles to Gr, which is 9 × 10(10) and 4 × 10(10) per mW, respectively. The maximum values of RI and G infer from the fitted curves of RI and G versus UV intensity are 3 × 10(5) A W(-1) and 10(6) , respectively. Therefore, the hybrid-channel FETs studied herein can be used as UV sensing devices with high performance and low power consumption, opening up new opportunities for future optoelectronic devices.
Scientific Reports | 2015
Do-Il Kim; Tran Quang Trung; Byeong-Ung Hwang; Jin-Su Kim; Sanghun Jeon; Jihyun Bae; Jong-Jin Park; Nae-Eung Lee
Mechanically adaptive electronic skins (e-skins) emulate tactition and thermoception by cutaneous mechanoreceptors and thermoreceptors in human skin, respectively. When exposed to multiple stimuli including mechanical and thermal stimuli, discerning and quantifying precise sensing signals from sensors embedded in e-skins are critical. In addition, different detection modes for mechanical stimuli, rapidly adapting (RA) and slowly adapting (SA) mechanoreceptors in human skin are simultaneously required. Herein, we demonstrate the fabrication of a highly sensitive, pressure-responsive organic field-effect transistor (OFET) array enabling both RA- and SA- mode detection by adopting easily deformable, mechano-electrically coupled, microstructured ferroelectric gate dielectrics and an organic semiconductor channel. We also demonstrate that the OFET array can separate out thermal stimuli for thermoreception during quantification of SA-type static pressure, by decoupling the input signals of pressure and temperature. Specifically, we adopt piezoelectric-pyroelectric coupling of highly crystalline, microstructured poly(vinylidene fluoride-trifluoroethylene) gate dielectric in OFETs with stimuli to allow monitoring of RA- and SA-mode responses to dynamic and static forcing conditions, respectively. This approach enables us to apply the sensor array to e-skins for bio-monitoring of humans and robotics.
ACS Applied Materials & Interfaces | 2017
Tae Young Choi; Byeong-Ung Hwang; Bo-Yeong Kim; Tran Quang Trung; Yun Hyoung Nam; Do-Nyun Kim; Kilho Eom; Nae-Eung Lee
Stretchable and transparent touch sensors are essential input devices for future stretchable transparent electronics. Capacitive touch sensors with a simple structure of only two electrodes and one dielectric are an established technology in current rigid electronics. However, the development of stretchable and transparent capacitive touch sensors has been limited due to changes in capacitance resulting from dimensional changes in elastomeric dielectrics and difficulty in obtaining stretchable transparent electrodes that are stable under large strains. Herein, a stretch-unresponsive stretchable and transparent capacitive touch sensor array was demonstrated by employing stretchable and transparent electrodes with a simple selective-patterning process and by carefully selecting dielectric and substrate materials with low strain responsivity. A selective-patterning process was used to embed a stretchable and transparent silver nanowires/reduced graphene oxide (AgNWs/rGO) electrode line into a polyurethane (PU) dielectric layer on a polydimethylsiloxane (PDMS) substrate using oxygen plasma treatment. This method provides the ability to directly fabricate thin film electrode lines on elastomeric substrates and can be used in conventional processes employed in stretchable electronics. We used a dielectric (PU) with a Poissons ratio smaller than that of the substrate (PDMS), which prevented changes in the capacitance resulting from stretching of the sensor. The stretch-unresponsive touch sensing capability of our transparent and stretchable capacitive touch sensor has great potential in wearable electronics and human-machine interfaces.
Electronic Materials Letters | 2012
Do-Il Kim; Byeong-Ung Hwang; Nguyen Thanh Tien; Il Jin Kim; Nae-Eung Lee
In this report, the electrical properties of both pentacene thin-film and pentacene organic thin-film transistors (OTFTs) under static and dynamic bending were investigated. From the responses to the applied static strain, the piezoresistivity coefficient of pentacene thin-film was determined to be 12.5. Significant changes in the field-effect mobility, μ, and the channel current, which were ascribed to the piezoresistivity of the pentacene channel in OTFTs, were observed while other parameters, such as contact resistance and gate capacitance, appear invariant up to the bending radius of 4.3 mm. Hysteresis in cyclic bending, which was assumed to be caused by local defects of pentacene thin-film, was observed to be independent of bending speed during dynamic bending tests.
Electronic Materials Letters | 2017
Ju Hyun Kim; Byeong-Ung Hwang; Do-Il Kim; Jin Soo Kim; Young Gug Seol; Tae Woong Kim; Nae-Eung Lee
Organic gate dielectrics in thin film transistors (TFTs) for flexible display have advantages of high flexibility yet have the disadvantage of low dielectric constant (low-k). To supplement low-k characteristics of organic gate dielectrics, an organic/inorganic nanocomposite insulator loaded with high-k inorganic oxide nanoparticles (NPs) has been investigated but high loading of high-k NPs in polymer matrix is essential. Herein, compositing of over-coated polyimide (PI) on self-assembled (SA) layer of mixed HfO2 and ZrO2 NPs as inorganic fillers was used to make dielectric constant higher and leakage characteristics lower. A flexible TFT with lower the threshold voltage and high current on/off ratio could be fabricated by using the hybrid gate dielectric structure of the nanocomposite with SA layer of mixed NPs on ultrathin atomic-layer deposited Al2O3.
Journal of Materials Chemistry B | 2014
Ok Ja Yoon; Chang Yong Jung; Il Yung Sohn; Young Min Son; Byeong-Ung Hwang; Il Jin Kim; Nae-Eung Lee
The two-dimensional nanocarbon material graphene (Gr) has been extensively studied due to its many potential biomedical applications including regenerative medicine, drug delivery, bioimaging, and biosensing. The effects of nitrogen-functionalisation on chemically driven Gr (CDG) cellular responses were studied by investigating the generation of reactive oxygen species (ROS) and mitochondrial morphology as well as focal adhesion, shape, proliferation and viability of HeLa cells grown on functionalised CDG (f-CDG) films. The drop casting of CDG nanosheets formed thin CDG films and the formation of nitrogen groups on the f-CDG thin films was mediated by N2 plasma treatment without the formation of observable surface defects. N-containing functional groups on the CDG thin films contributed to an increase in hydrophilicity. The proliferation and viability of HeLa cells grown on the f-CDG thin films were enhanced compared to those grown on CDG films alone and control samples. N-functionalisation of CDG thin films effectively reduced the ROS generated from cells on the f-CDG films. These results indicate that N2 plasma treatment of CDG is very useful in improving biocompatibility for the bio-application of graphene materials.