Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where C. Benitez-Medina is active.

Publication


Featured researches published by C. Benitez-Medina.


Nature | 2014

Search for Majorana neutrinos with the first two years of EXO-200 data

E. Beauchamp; D. Beck; V. Belov; C. Benitez-Medina; J. Bonatt; M. Breidenbach; T. Brunner; A. Burenkov; C. Chambers; J. Chaves; B. Cleveland; M. Coon; A. Craycraft; T. Daniels; M. Danilov; J. Davis; R. DeVoe; S. Delaquis; A. Dolgolenko; M. Dunford; J. Farine; W. Feldmeier; P. Fierlinger; D. Fudenberg; G. Giroux; R. Gornea; K. Graham; G. Gratta; S. Herrin; M. Hughes

Many extensions of the standard model of particle physics suggest that neutrinos should be Majorana-type fermions—that is, that neutrinos are their own anti-particles—but this assumption is difficult to confirm. Observation of neutrinoless double-β decay (0νββ), a spontaneous transition that may occur in several candidate nuclei, would verify the Majorana nature of the neutrino and constrain the absolute scale of the neutrino mass spectrum. Recent searches carried out with 76Ge (the GERDA experiment) and 136Xe (the KamLAND-Zen and EXO (Enriched Xenon Observatory)-200 experiments) have established the lifetime of this decay to be longer than 1025 years, corresponding to a limit on the neutrino mass of 0.2–0.4 electronvolts. Here we report new results from EXO-200 based on a large 136Xe exposure that represents an almost fourfold increase from our earlier published data sets. We have improved the detector resolution and revised the data analysis. The half-life sensitivity we obtain is 1.9 × 1025 years, an improvement by a factor of 2.7 on previous EXO-200 results. We find no statistically significant evidence for 0νββ decay and set a half-life limit of 1.1 × 1025 years at the 90 per cent confidence level. The high sensitivity holds promise for further running of the EXO-200 detector and future 0νββ decay searches with an improved Xe-based experiment, nEXO.


Physical Review Letters | 2012

Search for Neutrinoless Double-Beta Decay in 136 Xe with EXO-200

M. Auger; A. P. Waite; W. Feldmeier; T. N. Johnson; M. Hughes; P. C. Rowson; A. Kuchenkov; J. D. Wright; J.-L. Vuilleumier; T. Walton; K. Graham; C. G. Davis; A. Pocar; David A. Sinclair; K. Hall; A. Odian; S. Delaquis; K.S. Kumar; L. J. Kaufman; R. MacLellan; K. Twelker; M. Breidenbach; R. DeVoe; A. Burenkov; G. Giroux; S. Herrin; A. Sabourov; T. Brunner; P. Vogel; L. Yang

We report on a search for neutrinoless double-beta decay of 136Xe with EXO-200. No signal is observed for an exposure of 32.5 kg yr, with a background of ∼1.5×10(-3)  kg(-1) yr(-1)  keV(-1) in the ±1σ region of interest. This sets a lower limit on the half-life of the neutrinoless double-beta decay T(1/2)(0νββ)(136Xe)>1.6×10(25)  yr (90% C.L.), corresponding to effective Majorana masses of less than 140-380 meV, depending on the matrix element calculation.


Physical Review Letters | 2012

Search for Neutrinoless Double-Beta Decay in 136Xe with EXO-200

M. Auger; D. J. Auty; P. S. Barbeau; E. Beauchamp; V. Belov; C. Benitez-Medina; M. Breidenbach; T. Brunner; A. Burenkov; B. Cleveland; S. Cook; T. Daniels; M. Danilov; C. G. Davis; S. Delaquis; R. DeVoe; A. Dobi; M. J. Dolinski; A. Dolgolenko; M. Dunford; W. Fairbank; J. Farine; W. Feldmeier; P. Fierlinger; D. Franco; G. Giroux; R. Gornea; K. Graham; G. Gratta; C. Hall

We report on a search for neutrinoless double-beta decay of 136Xe with EXO-200. No signal is observed for an exposure of 32.5 kg yr, with a background of ∼1.5×10(-3)  kg(-1) yr(-1)  keV(-1) in the ±1σ region of interest. This sets a lower limit on the half-life of the neutrinoless double-beta decay T(1/2)(0νββ)(136Xe)>1.6×10(25)  yr (90% C.L.), corresponding to effective Majorana masses of less than 140-380 meV, depending on the matrix element calculation.


Journal of Instrumentation | 2012

The EXO-200 detector, part I: detector design and construction

M. Auger; D. J. Auty; P.S. Barbeau; L. Bartoszek; E. Baussan; E. Beauchamp; C. Benitez-Medina; M. Breidenbach; D. Chauhan; B. Cleveland; R. Conley; J. Cook; S. Cook; A. Coppens; W.W. Craddock; T. Daniels; C. G. Davis; J. Davis; R. DeVoe; A. Dobi; M. J. Dolinski; M. Dunford; W. Fairbank; J. Farine; P. Fierlinger; D. Franco; G. Giroux; R. Gornea; K. Graham; G. Gratta

EXO-200 is an experiment designed to search for double beta decay of 136Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most innovative aspects of the design that revolve around the reduction of backgrounds, the efficient use of the expensive isotopically enriched xenon, and the optimization of the energy resolution in a relatively large volume.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2009

Characterization of large area APDs for the EXO-200 detector

R. Neilson; F. LePort; A. Pocar; K.S. Kumar; A. Odian; C.Y. Prescott; V. Tenev; Nicole Ackerman; D. Akimov; M. Auger; C. Benitez-Medina; M. Breidenbach; A. Burenkov; R. Conley; S. Cook; R. DeVoe; M. J. Dolinski; W. Fairbank; J. Farine; P. Fierlinger; B. Flatt; R. Gornea; G. Gratta; M. P. Green; C. Hall; K. Hall; D. Hallman; C. Hargrove; S. Herrin; J. Hodgson

EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-lowbackground liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169 K—the temperature of liquid xenon. We also describe the individual characterization of more than 800 LAAPDs for selective installation in the EXO-200 detector.


Physical Review C | 2013

An improved measurement of the 2\nu \beta \beta\ half-life of Xe-136 with EXO-200

J. B. Albert; M. Auger; D. J. Auty; P. S. Barbeau; E. Beauchamp; D. Beck; V. Belov; C. Benitez-Medina; J. Bonatt; M. Breidenbach; T. Brunner; A. Burenkov; G. F. Cao; C. Chambers; J. Chaves; B. T. Cleveland; S. Cook; T. Daniels; M. Danilov; S. J. Daugherty; C. G. Davis; James G. Davis; S. Delaquis; R. DeVoe; A. Dobi; M. J. Dolinski; A. Dolgolenko; M. Dunford; W. Fairbank; J. Farine

We report on an improved measurement of the 2\nu \beta \beta\ half-life of Xe-136 performed by EXO-200. The use of a large and homogeneous time projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data analysis methods used for double-beta decay searches with EXO-200, while emphasizing those directly related to the present measurement. The Xe-136 2\nu \beta \beta\ half-life is found to be 2.165 +- 0.016 (stat) +- 0.059 (sys) x 10^21 years. This is the most precisely measured half-life of any 2\nu \beta \beta\ decay to date.


International Journal of Mass Spectrometry | 2015

An RF-only ion-funnel for extraction from high-pressure gases

T. Brunner; D. Fudenberg; V.L. Varentsov; A. Sabourov; G. Gratta; J. Dilling; R. DeVoe; David A. Sinclair; W. Fairbank; J. B. Albert; D. J. Auty; P.S. Barbeau; D. Beck; C. Benitez-Medina; M. Breidenbach; G. F. Cao; C. Chambers; B. Cleveland; M. Coon; A. Craycraft; T. Daniels; S. J. Daugherty; T. Didberidze; M. J. Dolinski; M. Dunford; L. Fabris; J. Farine; W. Feldmeier; P. Fierlinger; R. Gornea

An RF ion-funnel technique has been developed to extract ions from a high-pressure (10 bar) noble-gas environment into a vacuum (10(-6) mbar). Detailed simulations have been performed and a prototype has been developed for the purpose of extracting Ba-136 ions from Xe gas with high efficiency. With this prototype, ions have been extracted for the first time from high-pressure xenon gas and argon gas. Systematic studies have been carried out and compared to simulations. This demonstration of extraction of ions, with mass comparable to that of the gas generating the high-pressure, has applications to Ba tagging from a Xe-gas time-projection chamber for double-beta decay, as well as to the general problem of recovering trace amounts of an ionized element in a heavy (m > 40 u) carrier gas


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2012

Xenon purity analysis for EXO-200 via mass spectrometry

A. Dobi; C. Hall; S. Slutsky; B. Aharmin; M. Auger; P.S. Barbeau; C. Benitez-Medina; M. Breidenbach; B. Cleveland; R. Conley; J. Cook; S. Cook; I. Counts; W.W. Craddock; T. Daniels; C. G. Davis; J. Davis; R. DeVoe; M. S. Dixit; M. J. Dolinski; K. Donato; W. Fairbank; J. Farine; P. Fierlinger; D. Franco; G. Giroux; R. Gornea; K. Graham; G. Gratta; C. Green

Abstract We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We have used the technique to screen the EXO-200 xenon before, during, and after its use in our detector, and these measurements have proven useful. This is the first application of the cold trap mass spectrometry technique to an operating physics experiment.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2011

A xenon gas purity monitor for EXO

A. Dobi; C. Hall; S. Herrin; A. Odian; C.Y. Prescott; P.C. Rowson; Nicole Ackerman; B. Aharmin; M. Auger; P.S. Barbeau; K. Barry; C. Benitez-Medina; M. Breidenbach; S. Cook; I. Counts; T. Daniels; R. DeVoe; M. J. Dolinski; K. Donato; W. Fairbank; J. Farine; G. Giroux; R. Gornea; K. Graham; G. Gratta; M. P. Green; C. Hagemann; K. Hall; D. Hallman; C. Hargrove

We discuss the design, operation, and calibration of two versions of a xenon gas purity monitor (GPM) developed for the EXO double beta decay program. The devices are sensitive to concentrations of oxygen well below 1 ppb at an ambient gas pressure of one atmosphere or more. The theory of operation of the GPM is discussed along with the interactions of oxygen and other impurities with the GPM’s tungsten filament. Lab tests and experiences in commissioning the EXO-200 double beta decay experiment are described.


Review of Scientific Instruments | 2011

A magnetically driven piston pump for ultra-clean applications

F. LePort; R. Neilson; P.S. Barbeau; K. Barry; L. Bartoszek; I. Counts; J. Davis; R. DeVoe; M. J. Dolinski; G. Gratta; M. Green; M. Montero Díez; A. R. Müller; K. O’Sullivan; A. Rivas; K. Twelker; B. Aharmim; M. Auger; V. Belov; C. Benitez-Medina; M. Breidenbach; A. Burenkov; B. Cleveland; R. Conley; J. Cook; S. Cook; W.W. Craddock; T. Daniels; M. S. Dixit; A. Dobi

A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon time projection chamber of EXO-200. The pump, using sprung polymer gaskets, is capable of pumping more than 16 standard liters per minute of xenon gas with 750 Torr differential pressure.

Collaboration


Dive into the C. Benitez-Medina's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

J. Farine

Laurentian University

View shared research outputs
Top Co-Authors

Avatar

T. Daniels

University of Massachusetts Amherst

View shared research outputs
Top Co-Authors

Avatar

W. Fairbank

Colorado State University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

S. Cook

Colorado State University

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge