Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where C. de Asmundis is active.

Publication


Featured researches published by C. de Asmundis.


Europace | 2011

Pulmonary vein ostium shape and orientation as possible predictors of occlusion in patients with drug-refractory paroxysmal atrial fibrillation undergoing cryoballoon ablation

Antonio Sorgente; G.B. Chierchia; C. de Asmundis; Andrea Sarkozy; Mehdi Namdar; Lucio Capulzini; Yoshinao Yazaki; Stephan-Andreas Müller-Burri; Fatih Bayrak; Pedro Brugada

AIMS No specific data are available on the influence of pulmonary vein (PV) anatomy and shape on cryoballoon ablation (CA) catheter efficacy in delivering cryothermal energy and, consequently, in obtaining PV isolation. METHODS AND RESULTS Among a larger series of patients (68) with drug-refractory paroxysmal atrial fibrillation who underwent CA in our department, 52 patients were included in our study. All of them had a multislice cardiac computed tomography (MSCT) before the procedure. We retrospectively evaluated their MSCT scans focusing our attention on PV ovality and orientation in the frontal plane. A fair inverse association was documented between the ovality index of the left PVs and the degree of occlusion (r=-0.486 and P<0.003 for the LSPV and r=-0.360 and P=0.033 for the LIPV), whereas no association was found between the ovality index of the right PVs and the degree of occlusion (r=-0.283 and P=0.083 for the RSPV and r=0.235 and P=0.093 for RIPV). Nevertheless, a strong inverse association was found between the orientation of the PV ostia and the degree of occlusion in each vein (r=-0.804 and P<0.001 for the LSPV, r=-0.415 and P=0.013 for LIPV, r=-0.798 and P<0.001 for the RSPV, and r=-0.867 and P<0.001 for RIPV). CONCLUSION Pulmonary vein ostium shape and orientation evaluated by MSCT proved to be useful in predicting the degree of occlusion obtained during CA.


Europace | 2012

Isolating the pulmonary veins as first-line therapy in patients with lone paroxysmal atrial fibrillation using the cryoballoon.

Mehdi Namdar; Gian Battista Chierchia; S.W. Westra; Antonio Sorgente; Mark La Meir; Fatih Bayrak; Jayakeerthi Y. Rao; Danilo Ricciardi; C. de Asmundis; Andrea Sarkozy; Joep L.R.M. Smeets; Pedro Brugada

AIMS Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice. Nowadays, catheter-based ablative approaches are mainly reserved for drug-refractory patients. However, the value of an ablative therapy as a first-line alternative remains elusive. The aim of our study was to analyse the acute procedural success and clinical outcome of patients with lone paroxysmal AF undergoing cryoballoon ablation (CBA) as first-line treatment. METHODS AND RESULTS Eighteen individuals (mean age 44 ± 9 years, range 23-61 years, 15 males) with lone paroxysmal AF preferring a catheter-based treatment to drug treatment as first-line therapy were consecutively enrolled in our study. Mean left atrial size was 39 ± 4 mm and mean left ventricular ejection fraction 58 ± 3%. After a mean of 2.4 CBA (range 2-4) applications pulmonary vein (PV) isolation could be demonstrated in 70 (97%) PVs. Additional lesions with a focal ablation catheter were needed to isolate one right inferior pulmonary vein and one left superior pulmonary vein in two different patients. At the end of the procedure, all (100%) PVs were isolated. After a 2-month blanking period, 16 patients (89%) were free of symptomatic AF recurrence at a mean follow-up of 14 ± 9 months and without antiarrhythmic drugs (AADs). CONCLUSION Cryoballoon ablation in patients with lone paroxysmal AF yields a high acute efficacy rate with a great chance of being free of symptomatic AF recurrence without antiarrhythmic drugs on a mid-term follow-up period, when offered as a first-line treatment.


Europace | 2012

Pulmonary vein isolation during cryoballoon ablation using the novel Achieve inner lumen mapping catheter: a feasibility study.

Gian-Battista Chierchia; C. de Asmundis; Mehdi Namdar; Sjoerd W. Westra; M. Kuniss; Andrea Sarkozy; Fatih Bayrak; Danilo Ricciardi; Ruben Casado-Arroyo; M. Rodriguez Manero; Jayakeerthi Y. Rao; J. Smeets; Pedro Brugada

AIMS Cryoballoon (CB) ablation has proven very effective in achieving pulmonary vein isolation (PVI). The Achieve catheter (AC) is a novel inner lumen catheter designed to be used in conjunction with the CB, which serves the double purpose of a guidewire and a mapping catheter. We aimed to evaluate the feasibility of CB ablation in conjunction with the novel AC, in terms of PVI and safety in a series of patients affected by drug resistant paroxysmal atrial fibrillation (AF). METHODS AND RESULTS Seventy patients (49 male) affected by paroxysmal AF were assigned to CB PVI using the AC as a mapping catheter. Patients underwent loop-Holter monitoring 1, 3 and 6 months after ablation. Isolation occurred in 98% of PVs with the CB-AC association without having switching to a regular guidewire. Pulmonary vein isolation could be documented by real-time (RT) recordings in 47% (132) of veins. Time to isolation was significantly longer in PVs exhibiting early left atrium-PV reconnection if compared with veins with sustained isolation (117 ± 25 s vs. 59 ± 25 s; P< 0,005). No serious complications occurred; four transient phrenic nerve palsies occurred all resolving completely before the end of the procedure. CONCLUSION Cryoballoon ablation in conjunction with the novel AC is feasible, safe, and most importantly affords PVI in nearly all veins without having to switch to a regular guidewire. However, RT recordings could be documented in only 47% of pulmonary veins.


Europace | 2010

Feasibility, safety, and outcome of a challenging transseptal puncture facilitated by radiofrequency energy delivery: a prospective single-centre study.

Lucio Capulzini; Gaetano Paparella; Antonio Sorgente; C. de Asmundis; G.B. Chierchia; Andrea Sarkozy; A. Muller-Burri; Yoshinao Yazaki; Markus Roos; Pedro Brugada

AIMS Although it has been shown that a transseptal (TS) puncture in the electrophysiology laboratory is associated with a high success and a low complication rate, this procedure remains challenging particularly in difficult septum anatomies (aneurismal septum and thick septum) and during repeat TS catheterization. Radiofrequency (RF) electrocautery current delivery through the TS needle has been shown to facilitate the TS puncture. The aim of this study was to verify prospectively the feasibility, safety, and outcome of RF energy delivery associated with the standard TS technique in patients undergoing a challenging TS puncture. METHODS AND RESULTS Over a 14-month period, 162 consecutive patients underwent left atrial (LA) arrhythmia ablation in our centre. Among them, we enrolled 18 patients who failed LA access after two TS puncture attempts. In these patients, an RF delivery through TS (RF-TS) needle approach was used to reach the LA. All 18 patients had a successful RF-TS at the first attempt. A transoesophageal echocardiography (TEE) guidance and fluoroscopy views were used in all patients. No acute complications were reported. There have been no clinical sequelae after 10 +/- 4 months of follow-up following the RF-TS approach. Challenging TS punctures were more frequent in repeat LA catheterization when compared with the first LA catheterization, respectively, in 35% (13 of 37) and 4% (5 of 125) of the patients. CONCLUSION Radiofrequency electrocautery delivery associated with the standard TS approach is a safe and reproducible technique to reach the left atrium, using the TEE guidance. This technique is helpful during repeat TS catheterization and in the presence of anatomical atrial septum abnormalities.


Europace | 2012

Added value of transoesophageal echocardiography during transseptal puncture performed by inexperienced operators

Fatih Bayrak; G.B. Chierchia; Mehdi Namdar; Yoshinao Yazaki; Andrea Sarkozy; C. de Asmundis; Stephan-Andreas Müller-Burri; Jayakeerthi Y. Rao; Danilo Ricciardi; Antonio Sorgente; Pedro Brugada

AIMS Transseptal puncture (TP) appears to be safe in experienced hands; however, it can be associated with life-threatening complications. The aim of our study was to demonstrate the added value of routine use of transoesophageal echocardiography (TEE) for the correct positioning of the transseptal system in the fossa ovalis, thus potentially preventing complications during fluoroscopy-guided TP performed by inexperienced operators. METHODS AND RESULTS Two hundred and five patients undergoing pulmonary vein isolation procedure (PVI) for drug-resistant paroxysmal or persistent atrial fibrillation were prospectively included. When the operator (initially blinded to TEE) assumed that the transseptal system was in a correct position according to fluoroscopical landmarks, the latter was then checked with TEE unblinding the physician. If necessary, further refinement of the catheter position was performed. Refinement >10 mm, or in case of catheter pointing directly at the aortic root or posterior wall were considered as major repositioning. Thirty-four patients required major repositioning. Regression analysis revealed age (P: 0.0001, Wald: 12.9, 95% confidence interval: 1.04-1.16), left atrial diameter (P: 0.01, Wald: 6.6, 95% confidence interval: 1.04-1.34), previous PVI (P: 0.01, Wald: 6.3, 95% confidence interval: 1.31-8.76), and atrial septal thickness (P: 0.03, Wald: 4.5, 95% confidence interval: 1.05-3.4) as independent predictors of major revision with TEE. CONCLUSION Routine 2D TEE in addition to traditional fluoroscopic TP appears to be very useful to guide the TP assembly in a correct puncture position and thus, to avoid TP-related complications. However, further randomized prospective comparative studies are necessary to support these suggestions.


Europace | 2011

Complications of atrial fibrillation ablation: when prevention is better than cure.

Antonio Sorgente; G.B. Chierchia; C. de Asmundis; Andrea Sarkozy; Lucio Capulzini; Pedro Brugada

As atrial fibrillation ablation is becoming increasingly popular in many cardiac electrophysiological laboratories around the world, preventing, avoiding, or treating procedure-related complications is of utmost importance. In our review of the literature regarding this issue, we addressed in detail all the potential collateral and undesired effects associated to this intervention.


Europace | 2011

First experience of monitoring with cardiac event recorder electrocardiography Omron system in childhood population for sporadic, potentially arrhythmia-related symptoms

M. H. K. Park; C. de Asmundis; G.B. Chierchia; Andrea Sarkozy; A. Benatar; Pedro Brugada

AIMS To document symptomatic episodes of palpitations with traditional methods such as24 h Holter monitoring (HM) or loop recorders remains a big challenge in clinical practice. Clinical trials with patient-activated electrocardiography (ECG) recorders show increased diagnostic yield in such patients. However, studies in the paediatric population are limited. We want to present a first experience with an event-recording system Omron HeartScan in children with symptomatic palpitations. METHODS AND RESULTS Thirty paediatric patients (age 4-16 years) were followed with the Omron at our centre. All patients had a normal echocardiogram, a normal baseline 12-lead ECG and a normal 24 h HM. Indications with regard to monitoring were palpitations (n = 30). Two of them also had episodes of pre-syncope. The average of palpitation episodes in the past 3 months was 13.2 ± 8.3. The mean age of the study population was 9.7 ± 2.3 years [17 males (56.7 %)]. In all patients (n = 30) a diagnostic event could be recorded with the studied system. Four patients were diagnosed with supraventricular tachycardia (SVT) and underwent catheter ablation. The remaining patients (n = 26; 87%) were diagnosed with sinus tachycardia. Two patients with SVT additionally had episodes of pre-syncope. None of the patients could be diagnosed with previous 24 h HM. CONCLUSION This event recorder has a high diagnostic yield in the childhood population. The children enjoyed the ease of using the system under daily-life conditions. In this study the system was able to record a diagnostic event in all patients with palpitations.


Europace | 2018

Diagnosis-to-ablation time as a predictor of success: early choice for pulmonary vein isolation and long-term outcome in atrial fibrillation: results from the Middelheim-PVI Registry

Y De Greef; B. Schwagten; G.B. Chierchia; C. de Asmundis; Dirk Stockman; Ian Buysschaert

Aims The aim of the study is to define long-term outcome of pulmonary vein isolation (PVI) in atrial fibrillation (AF) and to determine whether time window between AF diagnosis and PVI affects outcome. Methods and results Consecutive AF patients undergoing PVI (2006-14) were followed for 5 years. Primary outcome was clinical success, defined as freedom of documented AF without anti-arrhythmic drugs respecting a 1-month blanking period. A 1000 patients were included (age 60 ± 10 years, CHA2DS2-VASc score 1 ± 1). The cohort was divided in four quartiles (Q) according to the diagnosis-to-ablation time (DAT): Q1 DAT 0-11 months (N = 244), Q2 DAT 12-≤33 months (N = 254), Q3 DAT 34-≤70 months (N = 252) and Q4 DAT 71-360 months (N = 250). Mean follow-up was 44.3±21.0 months. At 5 years, clinical success was achieved in 45.2 ± 2.0% of patients. Independent predictors of clinical success were AF type (HR = 0.61; 95%CI 0.50-0.74; P < 0.0001), left atrial size (HR = 1.03; 95%CI 1.02-1.05; P < 0.0001), DAT (HR = 1.00; 95%CI 1.00-1.00; P = 0.001), ablation technique (P = 0.012), and year of ablation (HR = 0.93; 95%CI 0.86-1.00; P = 0.045) in multivariable-adjusted analysis. The highest clinical success was achieved when PVI was performed within the first year, and gradually declined with increasing DAT: 55.9 ± 4.6% for Q1, 46.9 ± 4.0% for Q2, 45.5 ± 3.6% for Q3, and 35.5 ± 3.6% for Q4 (P < 0.001). Conclusion Long-term success rate of PVI is 45.2 ± 2.0%. Shorter diagnosis-to-ablation times are associated with better clinical success. Our data advocate for early PVI following diagnosis of AF.


Europace | 2012

Verification of pulmonary vein isolation during single transseptal cryoballoon ablation: a comparison between the classical circular mapping catheter and the inner lumen mapping catheter

Gian-Battista Chierchia; Mehdi Namdar; Andrea Sarkozy; A. Sorgente; C. de Asmundis; Ruben Casado-Arroyo; Lucio Capulzini; Fatih Bayrak; Moisés Rodríguez-Mañero; Danilo Ricciardi; Jayakeerthi Y. Rao; Ingrid Overeinder; Gaetano Paparella; Pedro Brugada


European Heart Journal | 2017

P2324A novel high risk ECG feature in Brugada Syndrome Probands: Localized QRS prolongation on right precordial leads

Burak Hünük; Giacomo Mugnai; C. de Asmundis; Vedran Velagic; Yukio Saitoh; G. Cioconte; Ghazala Irfan; Erwin Ströker; Ebru Hacioglu; V. De Regibus; Darragh Moran; Hugo Enrique Coutino-Moreno; O. Cagac; G.B. Chierchia; Pedro Brugada

Collaboration


Dive into the C. de Asmundis's collaboration.

Top Co-Authors

Avatar

G.B. Chierchia

Vrije Universiteit Brussel

View shared research outputs
Top Co-Authors

Avatar

Pedro Brugada

University of Southern California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Fatih Bayrak

Vrije Universiteit Brussel

View shared research outputs
Top Co-Authors

Avatar

Mehdi Namdar

Vrije Universiteit Brussel

View shared research outputs
Top Co-Authors

Avatar

Danilo Ricciardi

Vrije Universiteit Brussel

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Erwin Ströker

Vrije Universiteit Brussel

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Lucio Capulzini

Vrije Universiteit Brussel

View shared research outputs
Researchain Logo
Decentralizing Knowledge