Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where C. Iacobaeus is active.

Publication


Featured researches published by C. Iacobaeus.


ieee nuclear science symposium | 2002

Study of hole-type gas multiplication structures for portal imaging and other high counting rate applications

J. Ostling; Anders Brahme; Mats Danielsson; Tom Francke; C. Iacobaeus; Vladimir Peskov

We performed studies in the operation of various hole-type gaseous multiplication structures (GEM, capillary plates, and others) at very high fluxes of X-rays (<60 keV-bremsstrahlung) and pulsed gamma radiation (<50 MeV-bremsstrahlung). In the case of X-rays, the counting rate was 10/sup 5/-10/sup 6/ Hz/mm/sup 2/; in the case of gammas it reached levels of up to 10/sup 9/ Hz/mm/sup 2/ during the pulses. In most measurements, the entire area of the detector was exposed to these extremely high fluxes. Results obtained so far indicate that the GEM and the hydrogen-treated capillary plates could be successfully used in medical imaging applications.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2006

A study of the operation of especially designed photosensitive gaseous detectors at cryogenic temperatures

L. Periale; V. Peskov; C. Iacobaeus; B. Lund-Jensen; P. Pavlopoulos; P. Picchi; F. Pietropaolo

In some experiments and applications there is need for large-area photosensitive detectors to operate at cryogenic temperatures. Nowadays, vacuum PMs are usually used for this purpose. We have developed special designs of planar photosensitive gaseous detectors able to operate at cryogenic temperatures. Such detectors are much cheaper than PMs and are almost insensitive to magnetic fields. Results of systematic measurements of their quantum efficiencies, the maximum achievable gains and long-term stabilities will be presented. The successful operation of these detectors open realistic possibilities in replacing PMs by photosensitive gaseous detectors in some applications dealing with cryogenic liquids; for example in experiments using noble liquid TPCs or noble liquid scintillating calorimeters.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2004

The development of gaseous detectors with solid photocathodes for low-temperature applications

L. Periale; Vladimir Peskov; C. Iacobaeus; T. Francke; B. Lund-Jensen; N. Pavlopoulos; P. Picchi; F. Pietropaolo

There are several applications and studies in fundamental research, which require the detection of VUV light at cryogenic temperatures. For these applications, we have developed and successfully tested special designs of gaseous detectors with solid photocathodes able to operate at low temperatures: sealed gaseous detectors with MgF2 windows and windowless detectors. We have experimentally demonstrated that both primary and secondary (due to the avalanche multiplication inside liquids) scintillation light can be recorded by photosensitive gaseous detectors. The results of this work may allow one to significantly improve the operation of some noble liquid TPCs.


ieee nuclear science symposium | 2000

A novel portal imaging device for advanced radiation therapy

C. Iacobaeus; Anders Brahme; Mats Danielsson; P. Fonte; J. Ostling; Vladimir Peskov; Monika Wallmark

At Karolinska Institutet in Stockholm, Sweden a new detector for portal imaging is under development, which could greatly improve the alignment of the radiation beam with respect to the tumor during radiation treatment. The detector is based on gaseous and solid converters combined with GEMs as an amplification structures. The detector will have a large area and will be operated in a very high rate environment. A prototype has been built and extensively tested, both with high rate X-rays as well as in a clinical environment at the Karolinska Hospital. High rates and alpha particles could cause discharges in the GEM and discharge propagation from GEM to GEM and to the readout electronics. Since reliability is one of the main requirements for the portal imaging device, the authors performed systematic studies to find a safe operating range of the device, free from typical high-rate problems, such as discharges.


IEEE Transactions on Nuclear Science | 2005

The successful operation of hole-type gaseous detectors at cryogenic temperatures

L. Periale; V. Peskov; C. Iacobaeus; T. Francke; B. Lund-Jensen; P. Pavlopoulos; P. Picchi; F. Pietropaolo; Fuyuki Tokanai

We have demonstrated that hole-type gaseous detectors, GEMs and capillary plates, can operate up to 77 K. For example, a single capillary plate can operate at gains of above 10/sup 3/ in the entire temperature interval between 300 until 77 K. The same capillary plate combined with CsI photocathodes could operate perfectly well at gains (depending on gas mixtures) of 100-1000. Obtained results may open new fields of applications for capillary plates as detectors of UV light and charge particles at cryogenic temperatures: noble liquid TPCs, WIMP detectors or LXe scintillating calorimeters and cryogenic PETs.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2000

Evaluation of a GEM and CAT-based detector for radiation therapy beam monitoring

Anders Brahme; Mats Danielsson; C. Iacobaeus; J. Ostling; Vladimir Peskov; Monika Wallmark

We are developing a radiation therapy beam monitor for the Karolinska Institute. This monitor will consist of two consecutive detectors confined in one gas chamber: a keV-photon detector, which wil ...


Medical Imaging 2000: Physics of Medical Imaging | 2000

Novel detector for portal imaging in radiation therapy

J. Ostling; Monika Wallmark; Anders Brahme; Mats Danielsson; C. Iacobaeus; P. Fonte; Vladimir Peskov

We are developing a novel concept for portal imaging that would allow for on-line control and verification of the radiation treatment of cancer patients both at diagnostic and therapeutic energies. This device will consist of two consecutive detectors confided in one gas chamber: a KeV- photon detector, which can visualize the internal soft tissue of the patient, and an MeV-photon detector, which will measure the absolute intensity of the therapeutic beam and its position with respect to the tumor and normal tissues. Both detectors are based on gas and solid photon to electron converters combined with recently invented gas electron multipliers. The device will have a common charge collecting pad-type readout plate equipped with ASIC-based electronics for both detectors. A first simplified prototype device has recently been built and extensively tested. Special efforts were made to find conditions for a safe and reliable operation of the readout electronics that can be damaged by plasma-type discharge effects induced specially at high dose rates. Results obtained so far indicate that our new detector concept may satisfy all requirements on advanced therapy beam monitoring systems.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2001

Operating range of a gas electron multiplier for portal imaging

Monika Wallmark; Anders Brahme; Mats Danielsson; P. Fonte; C. Iacobaeus; Vladimir Peskov; J. Ostling

At the Karolinska Institute in Stockholm, Sweden a new detector for portal imaging is under development, which could greatly improve the alignment of the radiation beam with respect to the tumor during radiation treatment. The detector is based on solid converters combined with gas electron multipliers (GEMs) as an amplification structure. The detector has a large area and will be operated in a very high rate environment in the presence of heavy ionizing particles. As was discovered recently high rates and alpha particles could cause discharges in GEM and discharge propagation from GEM to GEM and to the readout electronics. Since reliability is one of the main requirements for the portal imaging device, we performed systematic studies to find a safe operating range of the device, free from typical high rate problems, such as discharges.


ieee nuclear science symposium | 2003

Study of capillary-based gaseous detectors

C. Iacobaeus; Tom Francke; Mats Danielsson; J. Ostling; V. Peskov

We have studied gain vs. voltage characteristics and position resolutions of multistep capillary plates (two or three capillary plates operating in a cascade), as well as capillary plates operating in a mode where the main amplification occurs in between the capillary plate and the readout plate (parallel plate amplification mode). Results of these studies demonstrated that in parallel-plate amplification mode one can reach both high gains (>10/sup 5/) and good position resolutions (/spl sim/100/spl mu/m) even with a single step arrangement. This offers a compact amplification structure which can be used in many applications.


IEEE Transactions on Nuclear Science | 2006

A high position resolution X-ray detector: an "Edge on" illuminated capillary plate combined with a gas amplification structure

C. Iacobaeus; T. Francke; B. Lund-Jensen; J. Ostling; P. Pavlopoulos; V. Peskov; Fuyuki Tokanai

We have developed and successfully tested a prototype of a new high position resolution hybrid X-ray detector. It contains a thin-wall lead glass capillary plate converter of X-rays combined with a microgap parallel-plate avalanche chamber operating in various gas mixtures at 1 atm. The operation of these converters was studied in a wide range of X-ray energies (from 6 to 60 keV) at incident angles varying from 0-90/spl deg/. The detection efficiency, depending on the geometry, photons energy, incident angle and the mode of operation was between 5-30% in single step mode and up to 50% in a multi-layered combination. Depending on the capillarys geometry, the position resolution achieved was between 50-250 /spl mu/m in digital form and was practically independent of the photons energy or gas mixture. The usual lead glass capillary plates operated without noticeable charging up effects at counting rates of 50 Hz/mm/sup 2/ and hydrogen treated capillaries-up to 10/sup 5/ Hz/mm/sup 2/. The developed detector has several important potential advantages over the exciting X-ray detectors and may open new possibilities for medical imaging, for example in mammography, portal imaging, radiography (including security devices), as well as many other applications.

Collaboration


Dive into the C. Iacobaeus's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Vladimir Peskov

Royal Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Mats Danielsson

Royal Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

B. Lund-Jensen

Royal Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

T. Francke

Royal Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

P. Fonte

University of Coimbra

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

V. Peskov

Goethe University Frankfurt

View shared research outputs
Researchain Logo
Decentralizing Knowledge