C. Kendziora
Fermilab
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by C. Kendziora.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2009
A. Curioni; B. T. Fleming; W. Jaskierny; C. Kendziora; J. Krider; S. Pordes; M. Soderberg; J. Spitz; T. Tope; T. Wongjirad
A filter system for removing electronegative impurities from liquid argon is described. The active components of the filter are adsorbing molecular sieve and activated-copper-coated alumina granules. The system is capable of purifying liquid argon to an oxygen-equivalent impurity concentration of better than 30 parts per trillion, corresponding to an electron drift lifetime of at least 10 ms. Reduction reactions that occur at �250 ◦ C allow the filter material to be regenerated in-situ through a simple procedure. In the following work we describe the filter design, performance, and regeneration process.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2005
S. Kopp; Dharma Indurthy; Z. Pavlovich; M. Proga; R. Zwaska; S. Childress; R. Ford; C. Kendziora; T. Kobilarcik; C. D. Moore; G. Tassotto
A prototype Secondary-electron Emission Monitor (SEM) was installed in the 8 GeV proton transport line for the MiniBooNE experiment at Fermilab. The SEM is a segmented grid made with 5 µm Ti foils, intended for use in the 120 GeV NuMI beam at Fermilab. Similar to previous workers, we found that the full collection of the secondary electron signal requires a bias voltage to draw the ejected electrons cleanly off the foils, and this effect is more pronounced at larger beam intensity. The beam centroid and width resolutions of the SEM were measured at beam widths of 3, 7, and 8 mm, and compared to calculations. Extrapolating the data from this
arXiv: Instrumentation and Detectors | 2005
S. Kopp; D. Indurthy; Z. Pavlovic; M. Proga; R. Zwaska; B. Baller; S. Childress; R. Ford; Deborah A. Harris; C. Kendziora; C. D. Moore; G. Tassotto
We present recent beam data from a new design of a profile monitor for proton beams at Fermilab. The monitors, consisting of grids of segmented Ti foils 5μm thick, are secondary-electron emission monitors (SEM’s). We review data on the device’s precision on beam centroid position, beam width, and on beam loss associated with the SEM material placed in the beam.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2009
R. Andrews; W. Jaskierny; H. Jöstlein; C. Kendziora; S. Pordes; Terry Tope
Archive | 2013
T. Alexander; D. Alton; K. Arisaka; P. Beltrame; J. Benziger; G. Bonfini; A. Brigatti; J. Brodsky; S. Bussino; L. Cadonati; F. Calaprice; A. Candela; H. Cao; P. Cavalcante; A. Chepurnov; S. Chidzik; C. Condon; S. Davini; M. De Vincenzi; E. de Haas; A. Derbin; G. Di Pietro; D. Durben; A. Empl; A. Etenko; A. Fan; G. Fiorillo; D. Franco; K. Fomenko; G. Forster
8th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators, DIPAC 2007 | 2007
S. Kopp; Bruce Baller; S. Childress; R. Ford; Deborah A. Harris; Dharma Indurthy; C. Kendziora; C. D. Moore; Žarko Pavlović; M. Proga; G. Tassotto; R. Zwaska
Bulletin of the American Physical Society | 2013
H. Cao; H. O. Back; F. Calaprice; C. Galbiati; P. D. Meyers; B. Rossi; L. Grandi; W.H. Lippincott; B. Loer; F. DeJongh; S. Pordes; J. Yoo; C. Kendziora; D. Montanari; T. Alexander; A. G. Cocco; G. Fiorillo; H. Wang; Y. Meng; C. J. Martoff; C. Love; Philippe Collon; W. Tan; C. Ghag; L. Manenti
8th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators, DIPAC 2007 | 2007
S. Kopp; Bruce Baller; S. Childress; R. Ford; Deborah A. Harris; Dharma Indurthy; C. Kendziora; C. D. Moore; Žarko Pavlović; M. Proga; G. Tassotto; R. Zwaska