Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where C.M.B. Monteiro is active.

Publication


Featured researches published by C.M.B. Monteiro.


Journal of Instrumentation | 2007

Secondary scintillation yield in pure xenon

C.M.B. Monteiro; L.M.P. Fernandes; J. A. M. Lopes; L. Coelho; J.F.C.A. Veloso; J.M.F. dos Santos; Karl-Ludwig Giboni; E. Aprile

The xenon secondary scintillation yield was studied as a function of the electric field in the scintillation region, in a gas proportional scintillation counter operated at room temperature. A large area avalanche photodiode was used for the readout of the VUV secondary scintillation produced in the gas, together with the 5.9 keV x-rays directly absorbed in the photodiode. The latter was used as a reference for the determination of the number of charge carriers produced by the scintillation pulse and, thus, the number of VUV photons impinging the photodiode. A value of 140 photons/kV was obtained for the scintillation amplification parameter. The attained results are in good agreement with those predicted, for room temperature, by Monte Carlo simulation and Boltzmann calculations, as well as with those obtained for saturated xenon vapour, at cryogenic temperatures, and are about a factor of two higher than former results measured at room temperature.


Journal of High Energy Physics | 2015

First proof of topological signature in high pressure xenon gas with electroluminescence amplification

P. Ferrario; D. Lorca; J.J. Gómez-Cadenas; G. Martínez-Lema; A. Martínez; J.F. Toledo; V. Álvarez; R. Esteve; S. Cebrián; A. Para; A. Cervera; F.P. Santos; E.D.C. Freitas; C.A.N. Conde; A. Laing; L. Ripoll; J. T. White; S. Cárcel; V.M. Gehman; P. Novella; A. L. Ferreira; P. Lebrun; F.J. Mora; F. Monrabal; A. Simón; A. Goldschmidt; N. López-March; D. Shuman; I.G. Irastorza; M. Querol

A bstractThe NEXT experiment aims to observe the neutrinoless double beta decay of 136Xe in a high-pressure xenon gas TPC using electroluminescence (EL) to amplify the signal from ionization. One of the main advantages of this technology is the possibility to reconstruct the topology of events with energies close to Qββ. This paper presents the first demonstration that the topology provides extra handles to reject background events using data obtained with the NEXT-DEMO prototype.Single electrons resulting from the interactions of 22Na 1275 keV gammas and electronpositron pairs produced by conversions of gammas from the 228Th decay chain were used to represent the background and the signal in a double beta decay. These data were used to develop algorithms for the reconstruction of tracks and the identification of the energy deposited at the end-points, providing an extra background rejection factor of 24.3 ± 1.4 (stat.)%, while maintaining an efficiency of 66.7 ± 1.% for signal events.


Advances in High Energy Physics | 2014

Present Status and Future Perspectives of the NEXT Experiment

J. J. Gómez Cadenas; V. Álvarez; F.I.G.M. Borges; S. Cárcel; J. Castel; S. Cebrián; A. Cervera; C.A.N. Conde; T. Dafni; T.H.V.T. Dias; J. Díaz; M Egorov; R. Esteve; P. Evtoukhovitch; L.M.P. Fernandes; P. Ferrario; A. L. Ferreira; E.D.C. Freitas; V.M. Gehman; A. Gil; A. Goldschmidt; Haley Louise Gomez; D. González-Díaz; R.M. Gutiérrez; J. M. Hauptman; J. A. Hernando Morata; D C Herrera; F. J. Iguaz; I. G. Irastorza; M A Jinete

NEXT is an experiment dedicated to neutrinoless double beta decay searches in xenon. The detector is a TPC, holding 100 kg of high-pressure xenon enriched in the 136Xe isotope. It is under construction in the Laboratorio Subterraneo de Canfranc in Spain, and it will begin operations in 2015. The NEXT detector concept provides an energy resolutionbetter than 1% FWHM and a topological signal that can be used to reduce the background. Furthermore, the NEXT technology can be extrapolated to a 1 ton-scale experiment.


Journal of Instrumentation | 2013

Initial results of NEXT-DEMO, a large-scale prototype of the NEXT-100 experiment

V. Álvarez; F.I.G.M. Borges; S. Cárcel; J. Castel; S. Cebrián; A Cervera; C.A.N. Conde; T. Dafni; T.H.V.T. Dias; J. Díaz; M Egorov; R Esteve; P Evtoukhovitch; L.M.P. Fernandes; P. Ferrario; A. L. Ferreira; E.D.C. Freitas; V.M. Gehman; A. Gil; A. Goldschmidt; Haley Louise Gomez; J.J. Gómez-Cadenas; D González-Díaz; R.M. Gutiérrez; J. M. Hauptman; J. A. Hernando Morata; D C Herrera; F. J. Iguaz; I. G. Irastorza; M A Jinete

This work was supported by the following agencies and institutions: the Ministerio de Economia y Competitividad of Spain under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP) and FPA2009-13697-C04-04; the Director, Office of Science, Office of Basic Energy Sciences, of the US Department of Energy under contract no. DE-AC02-05CH11231; and the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS/103860/2008. J. Renner (LBNL) acknowledges the support of a US DOE NNSA Stewardship Science Graduate Fellowship under contract no. DE-FC52-08NA28752.


Journal of High Energy Physics | 2016

Sensitivity of NEXT-100 to neutrinoless double beta decay

J. Martín-Albo; D. Lorca; J.J. Gómez-Cadenas; G. Martínez-Lema; A. Martínez; J.F. Toledo; V. Álvarez; T. Stiegler; R. Esteve; S. Cebrián; A. Para; A Cervera; F.P. Santos; J L Pérez Aparicio; E.D.C. Freitas; C.A.N. Conde; A. Laing; L. Ripoll; J. T. White; S. Cárcel; V.M. Gehman; P. Novella; A. L. Ferreira; P. Lebrun; F.J. Mora; F. Monrabal; A. Goldschmidt; N. López-March; D. Shuman; L. Serra

A bstractNEXT-100 is an electroluminescent high-pressure xenon gas time projection chamber that will search for the neutrinoless double beta (0νββ) decay of 136Xe. The detector possesses two features of great value for 0νββ searches: energy resolution better than 1% FWHM at the Q value of 136Xe and track reconstruction for the discrimination of signal and background events. This combination results in excellent sensitivity, as discussed in this paper. Material-screening measurements and a detailed Monte Carlo detector simulation predict a background rate for NEXT-100 of at most 4 × 10−4 counts keV−1 kg−1 yr−1. Accordingly, the detector will reach a sensitivity to the 0νββ-decay half-life of 2.8 × 1025 years (90% CL) for an exposure of 100 kg·year, or 6.0 × 1025 years after a run of 3 effective years.


Journal of Instrumentation | 2010

Primary and secondary scintillation measurements in a Xenon Gas Proportional Scintillation Counter

L.M.P. Fernandes; E.D.C. Freitas; M Ball; J.J. Gómez-Cadenas; C.M.B. Monteiro; N Yahlali; D Nygren; J.M.F. dos Santos

NEXT is a new experiment to search for neutrinoless double beta decay using a 100 kg radio-pure high-pressure gaseous xenon TPC. The detector requires excellent energy resolution, which can be achieved in a Xe TPC with electroluminescence readout. Hamamatsu R8520-06SEL photomultipliers are good candidates for the scintillation readout. The performance of this photomultiplier, used as VUV photosensor in a gas proportional scintillation counter, was investigated. Initial results for the detection of primary and secondary scintillation produced as a result of the interaction of 5.9 keV X-rays in gaseous xenon, at room temperature and at pressures up to 3 bar, are presented. An energy resolution of 8.0% was obtained for secondary scintillation produced by 5.9 keV X-rays. No significant variation of the primary scintillation was observed for different pressures (1, 2 and 3 bar) and for electric fields up to 0.8 V cm−1 torr−1 in the drift region, demonstrating negligible recombination luminescence. A primary scintillation yield of 81 ± 7 photons was obtained for 5.9 keV X-rays, corresponding to a mean energy of 72 ± 6 eV to produce a primary scintillation photon in xenon.


Journal of Instrumentation | 2013

Radiopurity control in the NEXT-100 double beta decay experiment: procedures and initial measurements

V. Álvarez; I. Bandac; A. Bettini; F.I.G.M. Borges; S. Cárcel; J. Castel; S. Cebrián; A Cervera; C.A.N. Conde; T. Dafni; T.H.V.T. Dias; J. Díaz; M Egorov; R Esteve; P Evtoukhovitch; L.M.P. Fernandes; P Ferrario; A. L. Ferreira; E.D.C. Freitas; V.M. Gehman; A. Gil; A. Goldschmidt; Haley Louise Gomez; J.J. Gómez-Cadenas; D González-Díaz; R.M. Gutiérrez; J. M. Hauptman; J. A. Hernando Morata; D C Herrera; F. J. Iguaz

We deeply acknowledge LSC directorate and staff for their strong support for performing the measurements at the LSC Radiopurity Service. The NEXT Collaboration acknowledges funding support from the following agencies and institutions: the Spanish Ministerio de Economia y Competitividad under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), Consolider-Ingenio 2010 CSD2007-00042 (CPAN), and under contracts ref. FPA2008-03456, FPA2009-13697-C04-04; FCT(Lisbon) and FEDER under grant PTDC/FIS/103860/2008; the European Commission under the European Research Council T-REX Starting Grant ref. ERC-2009-StG-240054 of the IDEAS program of the 7th EU Framework Program; Director, Office of Science, Office of Basic Energy Sciences, of the US Department of Energy under contract no. DE-AC02-05CH11231. Part of these grants are funded by the European Regional Development Fund (ERDF/FEDER). J. Renner (LBNL) acknowledges the support of a US DOE NNSA Stewardship Science Graduate Fellowship under contract no. DE-FC52-08NA28752. F.I. acknowledges the support from the Eurotalents program.


Physics Letters B | 2011

A simulation toolkit for electroluminescence assessment in rare event experiments

C.A.B. Oliveira; H. Schindler; R. Veenhof; S. Biagi; C.M.B. Monteiro; J.M.F. dos Santos; A. L. Ferreira; J.F.C.A. Veloso

Abstract A good understanding of electroluminescence is a prerequisite when optimising double-phase noble gas detectors for Dark Matter searches and high-pressure xenon TPCs for neutrinoless double beta decay detection. A simulation toolkit for calculating the emission of light through electron impact on neon, argon, krypton and xenon has been developed using the Magboltz and Garfield programs. Calculated excitation and electroluminescence efficiencies, electroluminescence yield and associated statistical fluctuations are presented as a function of electric field. Good agreement with experiment and with Monte Carlo simulations has been obtained.


Journal of Instrumentation | 2013

Ionization and scintillation response of high-pressure xenon gas to alpha particles

V. Álvarez; F.I.G.M. Borges; S. Cárcel; S. Cebrián; A Cervera; C.A.N. Conde; T. Dafni; J. Díaz; M Egorov; R Esteve; P Evtoukhovitch; L.M.P. Fernandes; P. Ferrario; A. L. Ferreira; E.D.C. Freitas; V.M. Gehman; A. Gil; A. Goldschmidt; Haley Louise Gomez; J.J. Gómez-Cadenas; D González-Díaz; R.M. Gutiérrez; J. M. Hauptman; J. A. Hernando Morata; D C Herrera; I. G. Irastorza; M A Jinete; L. Labarga; A. Laing; I. Liubarsky

High-pressure xenon gas is an attractive detection medium for a variety of applications in fundamental and applied physics. In this paper we study the ionization and scintillation detection properties of xenon gas at 10 bar pressure. For this purpose, we use a source of alpha particles in the NEXT-DEMO time projection chamber, the large scale prototype of the NEXT-100 neutrinoless double beta decay experiment, in three different drift electric field configurations. We measure the ionization electron drift velocity and longitudinal diffusion, and compare our results to expectations based on available electron scattering cross sections on pure xenon. In addition, two types of measurements addressing the connection between the ionization and scintillation yields are performed. On the one hand we observe, for the first time in xenon gas, large event-by-event correlated fluctuations between the ionization and scintillation signals, similar to that already observed in liquid xenon. On the other hand, we study the field dependence of the average scintillation and ionization yields. Both types of measurements may shed light on the mechanism of electron-ion recombination in xenon gas for highly-ionizing particles. Finally, by comparing the response of alpha particles and electrons in NEXT-DEMO, we find no evidence for quenching of the primary scintillation light produced by alpha particles in the xenon gas.


arXiv: Instrumentation and Detectors | 2009

The NEXT experiment

J. Díaz; N Yahlali; M Ball; J.A.S. Barata; F I G M Borges; E. Calvo; S. Cárcel; J.M. Carmona; S. Cebrián; A Cervera; X. Cid; C A N Conde; T. Dafni; T H V T Dias; L.M.P. Fernandes; E. Ferrer-Ribas; E.D.C. Freitas; J. Galán; A. Gil; I Gil; I. Giomataris; Haley Louise Gomez; J.J. Gómez-Cadenas; F. Granena; J.A. Hernando-Morata; F. J. Iguaz; I. G. Irastorza; J. A. M. Lopes; D. Martinez; C.M.B. Monteiro

Neutrinoless double beta decay measurements are the most promising experiments both to reveal the Majorana nature of the neutrino and to set a value for its mass. The NEXT project propose to build a High pressure Xenon TPC in the Canfranc Underground Laboratory (Huesca, Spain) to measure double-beta decay of 136Xe, both normal and neutrinoless, with a source mass of 100 kg of enriched xenon.

Collaboration


Dive into the C.M.B. Monteiro's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

S. Cárcel

Spanish National Research Council

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

J.J. Gómez-Cadenas

Spanish National Research Council

View shared research outputs
Top Co-Authors

Avatar

S. Cebrián

University of Zaragoza

View shared research outputs
Top Co-Authors

Avatar

V. Álvarez

Spanish National Research Council

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

J. Díaz

Spanish National Research Council

View shared research outputs
Researchain Logo
Decentralizing Knowledge