Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where C. von Birgelen is active.

Publication


Featured researches published by C. von Birgelen.


Eurointervention | 2012

Comparison of biolimus eluted from an erodible stent coating with bare metal stents in acute ST-elevation myocardial infarction (COMFORTABLE AMI trial): rationale and design

Lorenz Räber; C. von Birgelen

AIMS Compared with bare metal stents (BMS), early generation drug-eluting stents (DES) reduce the risk of revascularisation in patients with ST-elevation myocardial infarction (STEMI) at the expense of an increased risk of very late stent thrombosis (ST). Durable polymer coatings for controlled drug release have been identified as a potential trigger for these late adverse events and this has led to the development of newer generation DES with durable and biodegradable polymer surface coatings with improved biocompatibility. In a recent all-comers trial, biolimus-eluting stents with a biodegradable polymer surface coating were found to reduce the risk of very late ST by 80% compared with sirolimus-eluting stents with durable polymer, which also translated into a lower risk of cardiac death and myocardial infarction (MI) beyond one year. METHODS AND RESULTS The multicentre COMFORTABLE AMI trial (NCT00962416) randomly assigned 1,161 patients to treatment with biolimus-eluting stents with biodegrable polymer and bare metal stents of otherwise identical design at 11 international sites. The primary endpoint is a composite of cardiac death, target-vessel MI and target lesion revascularisation at one year. Assuming a relative risk reduction of 40% in event rates of the primary endpoint in favour of biolimus-eluting stents with biodegradable polymer, 1,064 patients will provide 80% power to demonstrate superiority. Clinical follow-up will be continued through five years. CONCLUSIONS The COMFORTABLE AMI trial will determine whether biolimus-eluting stents with biodegradable polymer are superior to bare metal stents of otherwise identical design. This is the first randomised controlled trial (RCT) investigating DES with a biodegradable polymer surface coating for drug release in the treatment of patients with STEMI.


Eurointervention | 2012

Comparison of eligible non-enrolled patients and the randomised TWENTE trial population treated with Resolute and XIENCE V drug-eluting stents

Hanim Sen; J. van der Palen; C. von Birgelen

AIMS The TWENTE trial recently enrolled more than 80% of all eligible patients, who were randomised to zotarolimus-eluting Resolute or everolimus-eluting XIENCE V stents. In the present study, we investigated whether eligible, non-enrolled patients differed from the randomised TWENTE trial population in baseline characteristics and one-year outcome. METHODS AND RESULTS Characteristics of 1,709 eligible patients were analysed. Independent external adjudication of clinical events was likewise performed for non-enrolled (n=318) and randomised patients (n=1,391). Non-enrolled and randomised patients did not differ in gender distribution, diabetes mellitus, and clinical presentation, but differed significantly in age and cardiovascular history. Nevertheless, clinical outcome after one year did not differ in the primary composite endpoint target-vessel failure (TVF; 9.8% vs. 8.1%; p=0.34), and its components cardiac death (1.6% vs. 1.2%; p=0.61), target vessel-related myocardial infarction (4.7% vs. 4.6%; p=0.92), and target-vessel revascularisation (3.8% vs. 3.0%; p=0.48). Previous bypass surgery predicted TVF in non-enrolled patients (p=0.001); removal of these patients resulted in identical TVF rates for non-enrolled and randomised patients (7.3% vs. 7.3%; p=0.99). CONCLUSIONS Despite some differences in baseline characteristics, non-enrolled and randomised patients did not differ in one-year outcome, which was favourable for both populations and may be related to the drug-eluting stents used.


Netherlands Heart Journal | 2013

Approaches for non-invasive assessment of endothelial function: focus on peripheral arterial tonometry

Jasveen J. Kandhai-Ragunath; Harald T. Jørstad; F.H.A.F. De Man; R. J. G. Peters; C. von Birgelen

The arterial endothelium is a complex organ that modulates vascular tone by release of various substances to control perfusion. Endothelial function reflects vascular ageing and health. Already at the earliest stages of atherosclerosis the delicate balance between arterial constriction and relaxation is disturbed. Therefore, non-invasive assessment of endothelial function is a means to identify patients at increased cardiovascular risk, even at levels of disease that cannot be identified with classical imaging techniques that depict arterial wall and/or lumen or with functional assessment of ischaemia. Currently, there is an increasing interest in the early recognition of endothelial dysfunction to streamline and optimise preventive therapeutic measures. In this article, several methods for the assessment of endothelial function are briefly reviewed. In particular, we discuss the fast bed-side assessment of endothelial function by the reactive hyperaemia peripheral arterial tonometry (RH-PAT) method.


Catheterization and Cardiovascular Interventions | 2012

Scanning electron microscopic assessment of coating irregularities and their precursors in unexpanded durable polymer-based drug-eluting stents

Mounir W.Z. Basalus; K. Tandjung; T. van Westen; Hanim Sen; P.K.N. van der Jagt; Dirk W. Grijpma; A.A. van Apeldoorn; C. von Birgelen

Objectives: To assess and quantify coating irregularities on unexpanded and expanded durable polymer‐based drug‐eluting stents (DES) to gain insights into the origin of coating irregularities. Background: Previous scanning electron microscopy (SEM) studies in various expanded DES revealed differences in frequency and size of coating irregularities between DES types and specific distribution patterns, however, the origin of these irregularities is unclear. Methods: We assessed at bench side a total of 1,200 SEM images obtained in 30 DES samples (15 expanded and 15 unexpanded) of Cypher Select Plus, Taxus Liberté, Endeavor, Xience V, and resolute. Results: For most coating irregularities seen on expanded DES (72%; 23/32), a matching irregularity (n = 18/23) and/or its precursor (n = 11/23) was observed in unexpanded DES. Unexpanded Cypher select showed (small) crater lesions and cracks together with precursors of “peeling.” On unexpanded Taxus Liberté, thinning of polymer, small bare metal areas, wrinkles, and one precursor type were found. Unexpanded endeavor showed cracks, small bare metal areas, crater lesions, and precursors of the latter. Unexpanded Xience V and resolute mainly revealed crater lesions and their precursors. On unexpanded versus expanded DES, there was no difference in measured frequency of coating irregularities and precursors (P = ns) with the exception of more bare metal areas on expanded Taxus Liberte (P = 0.01). Conclusions: Most coating irregularities, or the potential to develop them, are inherent to the unexpanded DES. Important determinants of the formation of coating irregularities may be the stent geometry and the physical properties of the coating, while stent‐balloon interaction plays no major role.


American Journal of Cardiology | 2012

Comparison of Frequency of Periprocedural Myocardial Infarction in Patients With and Without Diabetes Mellitus to Those With Previously Unknown but Elevated Glycated Hemoglobin Levels (from the TWENTE Trial)

Kenneth Tandjung; K.G. van Houwelingen; Hanneke Jansen; Mounir W.Z. Basalus; Hanim Sen; Marije M. Löwik; Martin G. Stoel; J. (Hans) W. Louwerenburg; F.H.A.F. De Man; Gerard C.M. Linssen; Rogier Nijhuis; Mark B. Nienhuis; van der Jacobus Palen; Ronald P. Stolk; C. von Birgelen

In patients without a history of diabetes mellitus, increased levels of glycated hemoglobin (HbA1c) are associated with higher cardiovascular risk. The relation between undetected diabetes and clinical outcome after percutaneous coronary intervention is unknown. To investigate whether these patients may have an increased risk of periprocedural myocardial infarction (PMI), the most frequent adverse event after percutaneous coronary intervention, we assessed patients of the TWENTE trial (a randomized, controlled, second-generation drug-eluting stent trial) in whom HbA1c data were available. Patients were classified as known diabetics or patients without a history of diabetes who were subdivided into undetected diabetics (HbA1c ≥6.5%) and nondiabetics (HbA1c <6.5%). Systematic measurement of cardiac biomarkers and electrocardiographic assessment were performed. One-year clinical outcome was also compared. Of 626 patients, 44 (7%) were undetected diabetics, 181 (29%) were known diabetics, and 401 (64%) were nondiabetics. In undetected diabetics the PMI rate was higher than in nondiabetics (13.6% vs 3.7%, p = 0.01) and known diabetics (13.6% vs 6.1%, p = 0.11). Multivariate analysis adjusting for covariates confirmed a significantly higher PMI risk in undetected diabetics compared to nondiabetics (odds ratio 6.13, 95% confidence interval 2.07 to 18.13, p = 0.001) and known diabetics (odds ratio 3.73, 95% confidence interval 1.17 to 11.89, p = 0.03). After 1 year, target vessel MI rate was significantly higher in undetected diabetics (p = 0.02) than in nondiabetics, which was related mainly to differences in PMI. Target vessel failure was numerically larger in unknown diabetics than in nondiabetics, but this difference did not reach statistical significance (13.6% vs 8.0%, p = 0.25). In conclusion, undetected diabetics were shown to have an increased risk of PMI.


Netherlands Heart Journal | 2009

RESPONSE study: Randomised Evaluation of Secondary Prevention by Outpatient Nurse SpEcialists: Study design, objectives and expected results.

Harald T. Jørstad; A. M. W. Alings; Anho Liem; C. von Birgelen; Jan G.P. Tijssen; C. J. de Vries; Dirk J. Lok; J.A. Kragten; R. J. G. Peters

Background. Patients with coronary artery disease are at high risk of coronary events and death, but effective secondary prevention can reduce this risk. There is a gap between guidelines on secondary prevention and the implementation of these measures, which could potentially be reduced by nurse led prevention clinics (NLPC).Objectives. The aim of the current study is to quantify the impact of NLPC on the risk of cardiovascular events in patients with established coronary artery disease.Methods. A randomised, multicentre clinical trial of NLPC in addition to usual care or usual care alone in post-acute coronary syndrome patients. (Neth Heart J 2009;17:322–8.)


Netherlands Heart Journal | 2010

TWENTE Study: The Real-World Endeavor Resolute Versus Xience V Drug-Eluting Stent Study in Twente: study design, rationale and objectives

Mounir W.Z. Basalus; K. Tandjung; K.G. van Houwelingen; Martin G. Stoel; F.H.A.F. De Man; J. (Hans) W. Louwerenburg; Salah A.M. Saïd; Gerard C.M. Linssen; Miep A.W.J. Kleijne; J. van der Palen; Jennifer Huisman; Patrick M.J. Verhorst; C. von Birgelen

Background. New-generation drug-eluting stents (DES) may solve several problems encountered with first-generation DES, but there is a lack of prospective head-to-head comparisons between new-generation DES. In addition, the outcome of regulatory trials may not perfectly reflect the outcome in ‘real world’ patients.Objectives. To compare the efficacy and safety of two new-generation DES in a ‘real world’ patient population.Methods. A prospective, randomised, single-blinded clinical trial to evaluate clinical outcome after Endeavor Resolute vs. Xience V stent implantation. The primary endpoint is target vessel failure at one-year follow-up. In addition, the study comprises a two-year and an open-label five-year follow-up. (Neth Heart J 2010;18:360-4.)


Netherlands Heart Journal | 2007

Full pattern of transient apical ballooning of the left ventricle triggered by minor myocardial infarction

C. Gurlek; J. van Es; P.H. van der Burgh; Michel A. Galjee; C. von Birgelen

A 60-year-old female with a history of hypertension, hypercholesterolaemia, and diabetes mellitus presented two hours after sudden onset of severe persistent chest pain. Electrocardiography showed ST-segment elevation in the inferolateral leads (figure 1A). Coronary angiography revealed a subtotal occlusion of a small left marginal side branch (figure 1B; arrow) and a normal right coronary artery, which could not explain the full typical pattern of apical ballooning as demonstrated by left ventricular angiography (figure 1C and D; arrows).


Netherlands Heart Journal | 2011

Acute left ventricular failure in a patient with hydroxychloroquine-induced cardiomyopathy

Marc Hartmann; I. L. Meek; G. K. van Houwelingen; H. P. C. M. Lambregts; G. J. Toes; A.C. van der Wal; C. von Birgelen

We present the case of a 75-year-old woman with a medical history of rheumatoid arthritis treated with hydroxychloroquine, who was admitted with acute left-sided heart failure due to a hydroxychloroquine-induced cardiomyopathy as supported by endomyocardial biopsy.


Netherlands Heart Journal | 2011

Contrast-enhancement cardiac magnetic resonance imaging beyond the scope of viability

M. A. G. M. Olimulder; Michel A. Galjee; J. van Es; Lodewijk J. Wagenaar; C. von Birgelen

The clinical applications of cardiovascular magnetic resonance imaging with contrast enhancement are expanding. Besides the direct visualisation of viable and non-viable myocardium, this technique is increasingly used in a variety of cardiac disorders to determine the exact aetiology, guide proper treatment, and predict outcome and prognosis. In this review, we discuss the value of cardiovascular magnetic resonance imaging with contrast enhancement in a range of cardiac disorders, in which this technique may provide insights beyond the scope of myocardial viability.

Collaboration


Dive into the C. von Birgelen's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Hanim Sen

Medisch Spectrum Twente

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Gerard C.M. Linssen

University Medical Center Groningen

View shared research outputs
Researchain Logo
Decentralizing Knowledge