Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Camino Bañuelos is active.

Publication


Featured researches published by Camino Bañuelos.


Circulation | 2005

Randomized Comparison of Sirolimus-Eluting Stent Versus Standard Stent for Percutaneous Coronary Revascularization in Diabetic Patients The Diabetes and Sirolimus-Eluting Stent (DIABETES) Trial

Manel Sabaté; Pilar Jiménez-Quevedo; Dominick J. Angiolillo; Joan Antoni Gómez-Hospital; Fernando Alfonso; Rosana Hernández-Antolín; Javier Goicolea; Camino Bañuelos; Javier Escaned; Raúl Moreno; Cristina Fernández; Francisco Fernández-Avilés; Carlos Macaya

Background— Outcomes after percutaneous coronary interventions in diabetic patients are shadowed by the increased rate of recurrence compared with nondiabetic patients. Methods and Results— We conducted a multicenter, randomized trial to demonstrate the efficacy of sirolimus-eluting stents compared with standard stents to prevent restenosis in diabetic patients with de novo lesions in native coronary arteries. The primary end point of the trial was in-segment late lumen loss as assessed by quantitative coronary angiography at 9-month follow-up. The trial was stratified by diabetes treatment status. One hundred sixty patients were randomized to sirolimus-eluting stents (80 patients; 111 lesions) or standard stent implantation (80 patients; 110 lesions). On average, reference diameter was 2.34±0.6 mm, lesion length was 15.0±8 mm, and 13.1% of lesions were chronic total occlusions. In-segment late lumen loss was reduced from 0.47±0.5 mm for standard stents to 0.06±0.4 mm for sirolimus stents (P<0.001). Target-lesion revascularization and major adverse cardiac event rates were significantly lower in the sirolimus group (31.3% versus 7.3% and 36.3% versus 11.3%, respectively; both P<0.001). Non–insulin- and insulin-requiring patients demonstrated similar reductions in angiographic and clinical parameters of restenosis after sirolimus-eluting stent implantation. During the 9-month follow-up, stent thrombosis occurred in 2 patients after standard stent implantation. Conversely, this phenomenon was not seen in the sirolimus stent group. Conclusions— This randomized trial demonstrated that sirolimus stent implantation is safe and efficacious in reducing both angiographic and clinical parameters of restenosis compared with standard stents in diabetic patients with de novo coronary stenoses.


Arteriosclerosis, Thrombosis, and Vascular Biology | 2006

Contribution of Gene Sequence Variations of the Hepatic Cytochrome P450 3A4 Enzyme to Variability in Individual Responsiveness to Clopidogrel

Dominick J. Angiolillo; Antonio Fernández-Ortiz; Esther Bernardo; Celia Ramirez; Ugo Cavallari; Elisabetta Trabetti; Manel Sabaté; Rosana Hernandez; Raúl Arrabales Moreno; Javier Escaned; Fernando Alfonso; Camino Bañuelos; Marco A. Costa; Theodore A. Bass; Pier Franco Pignatti; Carlos Macaya

Objectives—Metabolic activity of cytochrome P450 (CYP) 3A4 has been associated with clopidogrel response variability. Because metabolic activity of CYP3A4 is genetically regulated, we hypothesized that genetic variations of this enzyme may contribute to clopidogrel response variability. Methods and Results—The CYP3A4*1B, CYP3A4*3, IVS7+258A>G, IVS7+894C>T, and IVS10+12G>A polymorphisms of the CYP3A4 gene were assessed in 82 patients in a steady phase of clopidogrel therapy. Glycoprotein (platelet glycoprotein (GP) IIb/IIIa receptor activation and platelet aggregation were assessed. A cohort of 45 clopidogrel-naïve patients was studied to determine the modulating effects of these polymorphisms after loading dose (300 mg) administration. Only the IVS7+258A>G, IVS7+894C>T, and IVS10+12G>A polymorphisms were sufficiently polymorphic. During the steady phase of clopidogrel treatment, IVS10+12A allele carriers had reduced GP IIb/IIIa activation (P=0.025) and better responsiveness (P=0.02); similarly, clopidogrel-naïve patients carriers of the IVS10+12A allele had reduced GP IIb/IIIa activation during the first 24 hours after a loading dose (P=0.025), increased platelet inhibition (P=0.006), and a more optimal drug response (P=0.003). This polymorphism did not influence platelet aggregation profiles. No association was observed between the other polymorphisms and clopidogrel responsiveness. Conclusions—The IVS10+12G>A polymorphism of the CYP3A4 gene modulates platelet activation in patients treated with clopidogrel and may therefore contribute to clopidogrel response variability.


Circulation | 1999

Long-Term Clinical and Echocardiographic Follow-Up After Percutaneous Mitral Valvuloplasty With the Inoue Balloon

Rosa Hernandez; Camino Bañuelos; Fernando Alfonso; Javier Goicolea; Antonio Fernández-Ortiz; Javier Escaned; Luis Azcona; Carlos Almería; Carlos Macaya

BACKGROUND The objective of this study was to assess the long-term clinical outcome and valvular changes (area and regurgitation) after percutaneous mitral valvuloplasty (PMV). METHODS AND RESULTS After PMV, 561 patients were followed up for 39 (+/-23) months and clinical/echocardiographic data obtained yearly. Kaplan-Meier and Cox regression analyses were performed to estimate event-free survival, its predictors, and the relative risks of several patient subgroups. There were several nonexclusive events: 19 (3.3%) cardiac deaths, 55 (9.8%) mitral replacements, 6 (1%) repeated PMVs, 56 (10%) cases of restenosis, and 108 (19%) cases of clinical impairment. Survival free of major events (cardiac death, mitral surgery, repeat PMV, or functional impairment) was 69% at 7 years, ranging from 88% to 40% in different subgroups of patients. Wilkins score was the best preprocedural predictor of mitral opening, but the procedural result (mitral area and regurgitation) was the only independent predictor of major event-free survival. Mitral area loss, though mild [0.13 (+/-0.21)cm2], increased with time and was >/=0.3 cm2 in 12%, 22%, and 27% of patients at 3, 5, and 7 years, respectively. Regurgitation did not progress in 81% of patients, and when it occurred it was usually by 1 grade. CONCLUSIONS Seven years after PMV, more than two thirds of patients were in good clinical condition and free of any major event. The procedural result was the main determinant of long-term outcome, although a high score had also negative implications. Mitral area decreased progressively over time, whereas regurgitation did not tend to progress.


Heart | 2004

Findings of intravascular ultrasound during acute stent thrombosis

Fernando Alfonso; A Suárez; Dominick J. Angiolillo; Manel Sabaté; Javier Escaned; R Moreno; Rosana Hernandez; Camino Bañuelos; Carlos Macaya

Objective: To evaluate the potential role of intravascular ultrasound (IVUS) in evaluating patients experiencing an episode of acute stent thrombosis. Design and setting: Prospective observational study in a cardiac catheterisation laboratory in a university teaching hospital. Patients and interventions: IVUS was used to examine 12 patients undergoing coronary interventions for stent thrombosis to gain further mechanistic insights and to guide treatment. IVUS studies were obtained before and after intervention with a motorised pullback device. Main outcome measures: Qualitative and volumetric IVUS analyses. Results: Angiographically, 10 patients had occluded vessels and two patients had intraluminal filling defects within the stent. IVUS showed an occlusive thrombus in all patients. Thrombus volume was 90 (77) mm3, which was 51 (21)% of total stent volume. There was evidence of severe stent underexpansion in most patients and no patient fulfilled standard criteria for optimal stent implantation. Stent malapposition was detected in four patients, edge dissections were seen in two patients, and significant inflow-outflow disease was present in 11 patients. During interventions IVUS findings led to the use of higher pressures or larger balloons than those used during initial stenting in 10 patients. In addition, four patients required additional stenting, whereas a thrombectomy device alone was selected for one patient. After the procedure final minimum stent area (7.1 (2.1) v 5.3 (2) mm2, p < 0.005) and stent expansion (83.2 (17) v 62.1 (15)%, p < 0.005) improved compared with pre-interventional values. However, residual lining thrombus was still visualised in eight patients (25 (19) mm3, accounting for a 17% of final stent volume). Conclusions: IVUS provides an attractive technique to characterise fully the pattern of stent thrombosis, to identify readily the underlying mechanical predisposing factors, and to guide repeated coronary interventions.


Journal of the American College of Cardiology | 1994

Determinants of coronary compliance in patients with coronary artery disease: an intravascular ultrasound study.

Fernando Alfonso; Carlos Macaya; Javier Goicolea; Rosana Hernandez; Javier Segovia; Jose Luis Zamorano; Camino Bañuelos; Pedro Zarco

OBJECTIVES The aim of this study was to elucidate determinants of coronary compliance in patients with coronary artery disease. BACKGROUND Intravascular ultrasound potentially enables in vivo evaluation of coronary artery compliance. METHODS Twenty-seven patients (mean age [+/- SD] 57 +/- 11 years, three women) undergoing coronary angioplasty were studied with intravascular ultrasound imaging. A mechanical intravascular ultrasound system (4.8F, 20 MHz) was used. A total of 58 different coronary segments (proximal to the target angiographic lesion) were studied. Of these, 35 were located in the left anterior descending, 9 in the left main, 8 in the left circumflex and 6 in the right coronary arteries. During intravascular ultrasound imaging, 22 segments (38%) appeared normal, but 36 (62%) had plaque (24 fibrotic, 3 lipidic and 9 calcified). Systolic-diastolic changes in area (delta A) and pressure (delta P) with respect to vessel area (A) were used to study normalized compliance (Normalized compliance = [delta A/A]/delta P [mm Hg-1 x 10(3)]). RESULTS Lumen area and plaque area were 12.6 +/- 5.7 and 3 +/- 3 min2, respectively. Plaque was concentric (more than two quadrants) at 10 sites, but the remaining 26 plaques were eccentric. Compliance was inversely related to age (r = -0.34, p < 0.05) but was not related to other clinical variables. Compliance was greater in the left main coronary artery (3.9 +/- 2.1 vs. 1.8 +/- 1.2 mm Hg-1, p < 0.05) and in coronary segments with normal findings on ultrasound imaging (2.9 +/- 1.9 vs. 1.6 +/- 1.1 mm Hg-1, p < 0.01). Moreover, at diseased coronary segments compliance was lower in calcified plaques than in other types of plaques (1.2 +/- 0.7 vs. 2.3 +/- 1.6 mm Hg-1, p < 0.01) but was similar in concentric and eccentric plaques (1.6 +/- 1.5 vs. 1.6 +/- 0.9 mm Hg-1). Plaque area (r = -0.38, p < 0.01) was inversely correlated with compliance. On multivariate analysis, only age and plaque area were independently related to compliance. CONCLUSIONS Intravascular ultrasound may be used to evaluate compliance in patients with coronary artery disease. Compliance is reduced with increasing age and is mainly determined by the arterial site and by the presence, size and characteristics of plaque on intravascular ultrasound imaging.


Journal of the American College of Cardiology | 1997

Clinical and angiographic implications of coronary stenting in thrombus-containing lesions.

Fernando Alfonso; Pedro Rodriguez; Paul S Phillips; Javier Goicolea; Rosana Hernandez; Maria-José Pérez-Vizcayno; Antonio Fernández-Ortiz; Javier Segovia; Camino Bañuelos; Paloma Aragoncillo; Carlos Macaya

OBJECTIVES This study sought to determine the results of coronary stenting in thrombus-laden lesions. BACKGROUND The angiographic evidence of intracoronary thrombus has classically been considered a formal contraindication to stent implantation. However, with increasing use of stenting, the indications for this technique have widened to include treatment of patients who have an acute coronary syndrome or lesions with adverse anatomic features. METHODS We studied 86 consecutive patients (mean age +/- SD 61 +/- 11 years, 14 women) undergoing coronary stenting of a thrombus-containing lesion; the procedure was performed electively in 39% and after angioplasty failure in 61%. Sixty-four patients (75%) were treated for unstable angina, and 19 (22%) underwent the procedure during an acute myocardial infarction. A specific protocol that included clinical and late angiographic follow-up was used. RESULTS Angiographic success was obtained in 83 patients (96%). Five patients (6%) died during the hospital stay despite angiographic success; four of these had cardiogenic shock, and one (1%) had subacute stent thrombosis. Non-Q wave myocardial infarction developed in five additional patients (6%), and four of these five had data consistent with distal embolization. Of the 78 patients discharged with angiographic success, 67 (86%) were event-free and clinically improved at last follow-up visit (12 +/- 11 months). During the follow-up period, eight patients required repeat angioplasty, one patient required heart transplantation, and two patients died. Quantitative angiography demonstrated excellent angiographic results after stenting (minimal lumen diameter 0.31 +/- 0.4 vs. 2.77 +/- 0.6 mm). Late angiographic follow-up (5.5 +/- 1 months) was obtained in 50 patients with 54 lesions (93% of eligible), revealing a minimal lumen diameter of 2.0 +/- 1 mm and restenosis (lumen narrowing > 50%) in 18 lesions (33%). CONCLUSIONS Coronary stenting constitutes an effective therapeutic strategy for patients with thrombus-containing lesions, either after failure of initial angioplasty or electively as the primary procedure. Coronary stenting in this adverse anatomic setting results in a high degree of angiographic success, a low incidence of subacute thrombosis and an acceptable restenosis rate.


Journal of the American College of Cardiology | 1994

Coronary stenting for acute coronary dissection after coronary angioplasty: Implications of residual dissection

Fernando Alfonso; Rosana Hernandez; Javier Goicolea; Javier Segovia; María José Pérez-Vizcayno; Camino Bañuelos; Joao Carlos Silva; Pedro Zarco; Carlos Macaya

OBJECTIVES The aim of this study was to assess the implications of residual coronary dissections after stenting. BACKGROUND Coronary stenting is currently used in selected patients with coronary dissection after angioplasty. However, in some patients the total length of the dissection may not be completely covered with the device. METHODS Forty-two consecutive patients (mean [+/- SD] age 58 +/- 11 years; 39 men, 3 women) undergoing stenting for a major coronary dissection after angioplasty were studied. RESULTS Thirty (67%) coronary dissections were small (< or = 15 mm), and 29 (64%) were occlusive (Thrombolysis in Myocardial Infarction [TIMI] flow grade < or = 2). In 3 patients, coronary stenting was unable to open large occlusive dissections, but a good angiographic result was obtained in 39 patients (93%). After stenting, 22 of these patients (56%) had no visible residual dissections, and 13 (33%) had small and 4 (10%) had large residual dissections. These residual dissections were stable and did not compromise coronary flow. In a repeat angiogram (24 h later) the stent was patent in all 39 patients. However, two patients experienced a subacute stent occlusion. Of the remaining 37 patients, 36 (97%) had a late angiogram after stenting. Quantitative angiography revealed a reduction in minimal lumen diameter at the stent site (2.6 +/- 0.4 vs. 2 +/- 0.7 mm, p < 0.05) and a trend toward improvement in vessel diameter at the site of the previous residual dissection (1.7 +/- 0.6 vs. 1.9 +/- 0.5 mm, p < 0.1). The angiographic image of residual dissection disappeared in all patients. These factors provided a rather smooth angiographic appearance at follow-up. The four patients with large residual dissections after stenting did not have restenosis and were asymptomatic at last visit. CONCLUSIONS Coronary stenting is effective in the management of acute coronary dissections after angioplasty. In this setting, small residual dissections are frequently seen but have a good outcome and disappear at follow-up. Large residual dissections may have a good outcome if coronary flow is not impaired and no residual stenosis is visualized.


Circulation | 2013

Disturbed Coronary Hemodynamics in Vessels with Intermediate Stenoses Evaluated with Fractional Flow Reserve: A Combined Analysis of Epicardial and Microcirculatory Involvement in Ischemic Heart Disease

Mauro Echavarria-Pinto; Javier Escaned; Enrico Macías; Miguel Medina; Nieves Gonzalo; Ricardo Petraco; Sayan Sen; Pilar Jiménez-Quevedo; Rosana Hernandez; Rafael Mila; Borja Ibanez; Iván J. Núñez-Gil; Cristina Fernández; Fernando Alfonso; Camino Bañuelos; Eulogio García; Justin E. Davies; Antonio Fernández-Ortiz; Carlos Macaya

Background— In chronic ischemic heart disease, focal stenosis, diffuse atherosclerotic narrowings, and microcirculatory dysfunction (MCD) contribute to limit myocardial flow. The prevalence of these ischemic heart disease levels in fractional flow reserve (FFR) interrogated vessels remains largely unknown. Methods and Results— Using intracoronary measurements, 91 coronaries (78 patients) with intermediate stenoses were classified in 4 FFR and coronary flow reserve (CFR) agreement groups, using FFR>0.80 and CFR<2 as cutoffs. Index of microcirculatory resistance (IMR) and atherosclerotic burden (Gensini score) were also assessed. MCD was assumed when IMR≥29.1 (75th percentile). Fifty-four (59.3%) vessels had normal FFR, from which only 20 (37%) presented both normal CFR and IMR. Among vessels with FFR>0.80, most (63%) presented disturbed hemodynamics: abnormal CFR in 28 (52%) and MCD in 18 (33%). Vessels with FFR>0.80 presented higher IMR [adjusted mean 27.6 (95% confidence interval, 23.4–31.8)] than those with FFR⩽0.80 [17.3 (95% confidence interval, 13.0–21.7), p=0.001]. Atherosclerotic burden was inversely correlated with CFR (r=−0.207, P=0.055), and in vessels with FFR>0.80 and CFR<2 (n=28, 39%), IMR had a wide dispersion (7–72.7 U), suggesting a combination of diffuse atherosclerotic narrowings and MCD. Vessels with FFR⩽0.80 and normal CFR presented the lowest IMR, suggesting a preserved microcirculation. Conclusions— A substantial number of coronary arteries with stenoses showing an FFR>0.80 present disturbed hemodynamics. Integration of FFR, CFR, and IMR supports the existence of differentiated patterns of ischemic heart disease that combine focal and diffuse coronary narrowings with variable degrees of MCD.


Heart | 2012

Combined use of optical coherence tomography and intravascular ultrasound imaging in patients undergoing coronary interventions for stent thrombosis

Fernando Alfonso; Jaime Dutary; Manuel Paulo; Nieves Gonzalo; María José Pérez-Vizcayno; Pilar Jiménez-Quevedo; Javier Escaned; Camino Bañuelos; Rosana Hernandez; Carlos Macaya

Objective This prospective study sought to assess the diagnostic value of optical coherence tomography (OCT) compared with intravascular ultrasound (IVUS) in patients presenting with stent thrombosis (ST). Design and setting Although the role of IVUS in this setting has been described, the potential diagnostic value of OCT in patients suffering ST remains poorly defined. Catheterization Laboratory, University Hospital. Patients and interventions Fifteen consecutive patients with ST undergoing rescue coronary interventions under combined IVUS/OCT imaging guidance were analysed. Mean outcome measures Analysis and comparison of OCT and IVUS findings before and after interventions. Results Before intervention, OCT visualised the responsible thrombus in all patients (thrombus area 4.7±2.5 mm2, stent obstruction 82±14%). Minimal stent area was 4.7±2.1 mm2 leading to severe stent underexpansion (expansion 60±21%). Although red or mixed thrombus (14 patients) induced partial strut shadowing (total length 12.3±6 mm), malapposition (six patients), inflow-outflow disease (five patients), uncovered struts (nine patients) and associated in-stent restenosis (five patients, four showing neoatherogenesis) was clearly recognised. IVUS disclosed similar findings but achieved poorer visualisation of thrombus–lumen interface and strut malapposition, and failed to recognise uncovered struts and associated neoatherosclerosis. After interventions, OCT demonstrated a reduced thrombus burden (2.4±1.6 mm2) and stent obstruction (24±14%) with improvements in stent area (6.8±2.9 mm2) and expansion (75±21%) (all p<0.05). IVUS and OCT findings proved to be complementary. Conclusions OCT provides unique insights on the underlying substrate of ST and may be used to optimise results in these challenging interventions. In this setting, OCT and IVUS have complementary diagnostic values.


Catheterization and Cardiovascular Diagnosis | 1997

Aortic dissection occurring during coronary angioplasty: Angiographic and transesophageal echocardiographic findings

Fernando Alfonso; Carlos Almería; Antonio Fernández-Ortiz; Javier Segovia; Joaquín Ferreiros; Javier Goicolea; Rosana Hernandez; Camino Bañuelos; Manuel Gil-Aguado; Carlos Macaya

A localized acute aortic dissection was produced in 2 patients, complicating coronary angioplasty. In both cases a coronary dissection provided the entry door, with subsequent retrograde progression of the dissection into the aortic root. After sealing the entry door, both patients could be managed conservatively using transesophageal echocardiography to accurately define the location of the intimal flap and to rule out dissection progression.

Collaboration


Dive into the Camino Bañuelos's collaboration.

Top Co-Authors

Avatar

Carlos Macaya

Cardiovascular Institute of the South

View shared research outputs
Top Co-Authors

Avatar

Fernando Alfonso

Autonomous University of Madrid

View shared research outputs
Top Co-Authors

Avatar

Javier Escaned

Complutense University of Madrid

View shared research outputs
Top Co-Authors

Avatar

Rosana Hernandez

Complutense University of Madrid

View shared research outputs
Top Co-Authors

Avatar

Antonio Fernández-Ortiz

Cardiovascular Institute of the South

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Javier Goicolea

Autonomous University of Madrid

View shared research outputs
Top Co-Authors

Avatar

Raúl Moreno

Hospital Universitario La Paz

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Rosana Hernández-Antolín

Complutense University of Madrid

View shared research outputs
Researchain Logo
Decentralizing Knowledge