Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Carla A. Hartwig is active.

Publication


Featured researches published by Carla A. Hartwig.


Analytical Methods | 2014

Determination of bromine and iodine in shrimp and its parts by ICP-MS after decomposition using microwave-induced combustion

Carla A. Hartwig; Isis Gonçalves Toralles; Marcelo Guerreiro Crizel; Aline Lima Hermes Müller; Rochele S. Picoloto; Erico M.M. Flores; Marcia F. Mesko

A digestion method based on microwave-induced combustion (MIC) was developed for bromine and iodine determination in shrimp and its parts (shells and head, and tissue) by inductively coupled plasma mass spectrometry (ICP-MS). Ammonium nitrate solution was used as an igniter for combustion and vessels were pressurized with O2 at 20 bar. Solutions of (NH4)2CO3 (50 or 100 mmol L−1) and NH4OH (25, 50, 75 or 100 mmol L−1) were evaluated as absorbing media for Br and I. Better results were obtained for Br and I determination using 50 mmol L−1 NH4OH as absorbing medium. Using this solution, blanks were always negligible and memory effects were virtually absent. The accuracy of the proposed MIC method was evaluated using a reference material (NIST 8414) with agreement better than 99% for both analytes. The limits of detection by MIC and further ICP-MS determination (Br: 0.12 μg g−1; I: 0.001 μg g−1) were better than those obtained when the extraction procedure was used. Additionally, a microwave-assisted alkaline extraction method was also evaluated using 0.11 mol L−1 TMAH as extractant solution. However, alkaline extraction was only feasible for shrimp tissue and not for whole shrimp or shells. Decomposition using MIC allowed the determination of Br and I by ICP-MS in shrimp and the respective distribution of these elements in shells and head, and in tissue avoiding the use of concentrated digestion or extraction solutions.


Talanta | 2016

Feasibility of halogen determination in noncombustible inorganic matrices by ion chromatography after a novel volatilization method using microwave-induced combustion.

Rodrigo M. Pereira; Vanize C. Costa; Carla A. Hartwig; Rochele S. Picoloto; Erico M.M. Flores; Fabio A. Duarte; Marcia F. Mesko

A microwave-induced combustion (MIC) system based on the volatilization process was applied for subsequent halogen determination from noncombustible inorganic matrices. Portland cement samples were selected to demonstrate the feasibility of the proposed method, allowing the subsequent determination of Cl and F by ion chromatography (IC). Samples were mixed with high-purity microcrystalline cellulose, wrapped with a polyethylene film and combusted in quartz closed vessels pressurized with oxygen (20bar). Water and NH4OH (10, 25 or 50m mol L(-1)) were evaluated for Cl and F absorption, but water was selected, using 5min of reflux after volatilization. Final solutions were also suitable for analysis by pontentiometry with ion-selective electrode (ISE) for both analytes, and no difference was found when comparing the results with IC. The accuracy of the proposed method for Cl was evaluated by analysis of certified reference materials (CRMs), and agreement with certified values ranged from 98% to 103%. Results were also compared to those using the procedure recommended by the American Society of Testing and Materials (ASTM) for the determination of total chlorides (C114-13), and no difference was found. Volatilization by MIC using a mixture of cement, cellulose and a biological CRM was carried out in order to evaluate the accuracy for F, and recovery was about 96%. The proposed method allowed suitable limits of detection for Cl and F by IC (99 and 18mg kg(-1), respectively) for routine analysis of cement. Using the proposed method, a relatively low standard deviation (<7%), high throughput (up to eight samples can be processed in less than 30min) and lower generation of laboratory effluents, when compared to the ASTM method, were obtained. Therefore, the method for volatilization of Cl and F by MIC and subsequent determination by IC can be proposed as a suitable alternative for cement analysis.


Journal of Analytical Atomic Spectrometry | 2016

The synergic effect of microwave and ultraviolet radiation for chocolate digestion and further determination of As, Cd, Ni and Pb by ICP-MS

Carla A. Hartwig; Rodrigo M. Pereira; Filipe Soares Rondan; Sandra M. Cruz; Fabio A. Duarte; Erico M.M. Flores; Marcia F. Mesko

The synergic effect between microwave and ultraviolet radiation was proposed for chocolate digestion and further toxic element determination by inductively coupled plasma mass spectrometry (ICP-MS). As, Cd, Ni and Pb were chosen to show the applicability of the proposed method. Ultraviolet radiation was generated in situ using a low-pressure Cd discharge microwave lamp inside each digestion vessel. HNO3 solutions of several concentrations (2, 4, 7 and 14.4 mol L−1) were evaluated as digestion media. Parameters such as sample mass and microwave irradiation time were also evaluated in order to provide the best conditions for chocolate digestion. A relatively high sample mass, up to 600 mg of chocolate (white and milk), was digested using a diluted acid solution (10 mL of 4 mol L−1 HNO3), allowing for a final solution with dissolved carbon content lower than 100 mg L−1, which was suitable for ICP-MS measurements. The accuracy of the proposed method was evaluated by the digestion of a certified reference material (CRM, BCR 414), and the agreement with the certified values for all analytes was between 95 and 98%. Recovery tests were also performed and results between 95 and 104% for all analytes were obtained. The limits of detection for As, Cd, Ni and Pb by the proposed method were 0.87, 0.98, 29.7 and 7.85 ng g−1, respectively. Thus, for the first time, chocolate was efficiently digested using only a diluted acid solution (digestion efficiency was higher than 90%). Moreover, the digests were suitable for subsequent ICP-MS analysis without any filtration and/or extra-dilution step, as generally reported in the literature.


Journal of Agricultural and Food Chemistry | 2016

Bromine and Iodine Contents in Raw and Cooked Shrimp and Its Parts

Márcia F. Mesko; Isis Gonçalves Toralles; Carla A. Hartwig; Gilberto Silva Coelho; Aline Lima Hermes Müller; Cezar A. Bizzi; Paola A. Mello

The concentration of bromine and iodine was determined in shrimp and its parts (tissue and shells), and changes in the analyte concentration were evaluated after the cooking procedure. Bromine and iodine concentrations were determined by a method recently developed by our research group based on microwave-induced combustion for sample preparation and inductively coupled plasma mass spectrometry for analyte determination. The accuracy was evaluated using a reference material (NIST 8414) that was digested using the proposed method. No statistical difference was observed between certified and determined values (Students t test, 95% confidence level). Suitable limits of detection (Br, 0.02 μg g(-1) and I, 0.01 μg g(-1)) were obtained for both analytes. Higher concentrations of both analytes were observed in shrimp shells in comparison to shrimp tissue for raw and cooked samples. Moreover, losses of Br and I (between 24 and 43%) were observed after cooking.


Analytical Methods | 2015

A new method for chlorine determination in commercial pet food after decomposition by microwave-induced combustion

Marcelo Guerreiro Crizel; Carla A. Hartwig; Diogo La Rosa Novo; Isis Gonçalves Toralles; Lucas Schmidt; Edson I. Muller; Marcia F. Mesko

In this work, the feasibility of a new sample preparation method was demonstrated for commercial pet food digestion for the determination of chlorine by ion selective electrode (ISE). Pet food decomposition was performed by microwave-induced combustion (MIC) and up to 600 mg of sample was combusted in closed vessels using 20 bar of O2. Solutions of (NH4)2CO3 or ultrapure water were evaluated as absorbing mediums. Using the selected conditions, Cl recovery was higher than 96% and the relative standard deviation (RSD) was lower than 6%. Accuracy was evaluated using two certified reference materials with agreement better than 95%. Chlorine was also determined in digests by ion chromatography and results were in agreement better than 97%. For comparison of results, samples were also digested using the method recommended by Association of Official Analytical Chemists (AOAC) and results for Cl were in agreement with those obtained by the proposed method; however, the RSD was up to 16%. The limit of detection (LOD) for Cl by MIC and subsequent determination by ISE was 90 µg g−1, whereas the LOD for Cl by AOAC method was 3480 µg g−1. MIC allowed the digestion of commercial pet food samples with high efficiency (>98%) and was suitable for further Cl determination by ISE.


Talanta | 2017

Green and efficient sample preparation method for the determination of catalyst residues in margarine by ICP-MS

Carla A. Hartwig; Rodrigo M. Pereira; Diogo La Rosa Novo; Dirce Taina Teixeira Oliveira; Marcia F. Mesko

Responding to the need for green and efficient methods to determine catalyst residues with suitable precision and accuracy in samples with high fat content, the present work evaluates a microwave-assisted ultraviolet digestion (MW-UV) system for margarines and subsequent determination of Ni, Pd and Pt using inductively coupled plasma mass spectrometry (ICP-MS). It was possible to digest up to 500mg of margarine using only 10mL of 4molL-1 HNO3 with a digestion efficiency higher than 98%. This allowed the determination of catalyst residues using the ICP-MS and free of interferences. For this purpose, the following experimental parameters were evaluated: concentration of digestion solution, sample mass and microwave irradiation program. The residual carbon content was used as a parameter to evaluate the efficiency of digestion and to select the most suitable experimental conditions. The accuracy evaluation was performed by recovery tests using a standard solution and certified reference material, and recoveries ranging from 94% to 99% were obtained for all analytes. The limits of detection for Ni, Pd and Pt using the proposed method were 35.6, 0.264 and 0.302ngg-1, respectively. When compared to microwave-assisted digestion (MW-AD) in closed vessels using concentrated HNO3 (used as a reference method for sample digestion), the proposed MW-UV could be considered an excellent alternative for the digestion of margarine, as this method requires only a diluted nitric acid solution for efficient digestion. In addition, MW-UV provides appropriate solutions for further ICP-MS determination with suitable precision (relative standard deviation < 7%) and accuracy for all evaluated analytes. The proposed method was applied to margarines from different brands produced in Brazil, and the concentration of catalyst residues was in agreement with the current legislation or recommendations.


Archive | 2013

Synthesis and Characterisation of Carbon Nanocomposites

Matheus Z. Krolow; Carla A. Hartwig; G. C. Link; Cristiane W. Raubach; J. S. F. Pereira; R. S. Picoloto; M. R. F. Gonçalves; Neftalí L. V. Carreño; Marcia F. Mesko

Carbon nanocomposites have received more attention in the last years in view of their special properties such as low density, high specific surface area, and thermal and mechanical stability. Taking into account the importance of these materials, many studies aimed at improving the synthesis process have been conducted. However, the presence of impurities could affect significantly the properties of these materials, and the characterisation of these compounds is an important challenge to assure the quality of the new carbon nanocomposites. Thus, in this work are presented the characteristics of carbon nanocomposites, the improvements and developments in the synthesis process, as well as the most used characterisation techniques of these compounds.


Food Chemistry | 2018

A Novel and Eco-Friendly Analytical Method for Phosphorus and Sulfur Determination in Animal Feed

Diogo La Rosa Novo; Rodrigo M. Pereira; Vanize C. Costa; Carla A. Hartwig; Márcia F. Mesko

An eco-friendly method for indirect determining phosphorus and sulfur in animal feed by ion chromatography was proposed. Using this method, it was possible to digest 500 mg of animal feed in a microwave system under oxygen pressure (20 bar) using only a diluted acid solution (2 mol L-1 HNO3). The accuracy of the proposed method was evaluated by recovery tests, by analysis of reference material (RM) and by comparison of the results with those obtained using conventional microwave-assisted digestion. Moreover, P results were compared with those obtained from the method recommended by AOAC International for animal feed (Method nr. 965.17) and no significant differences were found between the results. Recoveries for P and S were between 94 and 97%, and agreements with the reference values of RM were better than 94%. Phosphorus and S concentrations in animal feeds ranged from 10,026 to 28,357 mg kg-1 and 2259 to 4601 mg kg-1, respectively.


Talanta | 2018

A selective volatilization method for determination of chloride and sulfate in calcium carbonate pharmaceutical raw material and commercial tablets

Diogo La Rosa Novo; Rodrigo M. Pereira; Carla A. Hartwig; Clarissa M.M. Santos; Marcia F. Mesko

In this work a feasible method for chloride and sulfate determination in calcium carbonate pharmaceutical raw material and commercial tablets by ion chromatography after microwave-induced combustion was developed. The analytes were released from matrix by combustion in closed system pressurized with oxygen. Starch as volatilization aid, 100mmolL-1 HNO3 as absorbing solution and 5min of microwave irradiation time were used. Recovery tests using standard solutions were performed for the accuracy evaluation. A mixture of calcium carbonate pharmaceutical raw material or commercial tablets, starch and a certified reference material was also used as a type of recovery test. Recoveries ranging from 88% to 103% were obtained in both spike tests. Limits of detection (Cl-: 40µgg-1 and SO42-: 140µgg-1) were up to eighteen times lower than the maximum limits established for the analytes by Brazilian, British, European and Indian Pharmacopoeias. The limit tests recommended by the European Pharmacopoeia for Cl- and SO42- in CaCO3 were carried out to compare the results. Chloride and SO42- concentrations in the samples analyzed by proposed method were in agreement with those results obtained using the tests recommended by the European Pharmacopoeia. However, the proposed method presents several advantages for the routine analysis when compared to pharmacopoeial methods, such as the quantitative simultaneous determination, high sample preparation throughput (up to eight samples per run in less than 30min), reduced volume of reagents and waste generation. Thus, the proposed method is indicated as an excellent alternative for Cl- and SO42- determination in CaCO3 pharmaceutical raw material and commercial tablets.


Journal of The Mechanical Behavior of Biomedical Materials | 2018

New adhesive system based in metals cross-linking methacrylate

Alexandra Rubin Cocco; Wellington Luiz de Oliveira da Rosa; Sonia Luque Peralta; Tamires Timm Maske; Adriana Fernandes da Silva; Carla A. Hartwig; Márcia F. Mesko; Evandro Piva; Rafael Guerra Lund

This study evaluated the anti-antibiofilm potential of silver methacrylate (Ag) or di-n-butyldimethacrylatetin (Sn) in experimental adhesive systems. Ag and Sn methacrylates were incorporated at 0.5mol%, 1mol% and 2mol% in an adhesive resin. The anti-antibiofilm potential, degree of conversion (DC), microtensile bond strength (μTBS), water sorption/solubility (WSR/SL), bonded interfaces pattern (SEM), cytotoxicity and leaching of Ag and Sn ions were evaluated. Data were statistically analyzed considering α = 0.05. Only Ag at 2% affected DC and μTBS. Ag at 1% and 2% and Sn at 1% and 2% showed anti-biofilm potential against Mutans streptococci. Ag at 1% and 2% and Sn at 2% showed a statistically significant difference to the control in WSR/SL (p < 0.05). The additions of metal methacrylate did not affect cell viability, being the adhesive resins statistically similar to controls. Leached metals of Ag were more than 100x higher than for Sn. Between the concentration tested, Ag and Sn methacrylate at 1% presented an anti-biofilm effect without altering the mechanical properties evaluated.

Collaboration


Dive into the Carla A. Hartwig's collaboration.

Top Co-Authors

Avatar

Marcia F. Mesko

Universidade Federal de Pelotas

View shared research outputs
Top Co-Authors

Avatar

Rodrigo M. Pereira

Universidade Federal de Pelotas

View shared research outputs
Top Co-Authors

Avatar

Diogo La Rosa Novo

Universidade Federal de Pelotas

View shared research outputs
Top Co-Authors

Avatar

Vanize C. Costa

Universidade Federal de Pelotas

View shared research outputs
Top Co-Authors

Avatar

Erico M.M. Flores

Universidade Federal de Santa Maria

View shared research outputs
Top Co-Authors

Avatar

Márcia F. Mesko

Universidade Federal de Santa Maria

View shared research outputs
Top Co-Authors

Avatar

Cezar A. Bizzi

Universidade Federal de Santa Maria

View shared research outputs
Top Co-Authors

Avatar

Fabio A. Duarte

Universidade Federal de Santa Maria

View shared research outputs
Top Co-Authors

Avatar

Isis Gonçalves Toralles

Universidade Federal de Pelotas

View shared research outputs
Top Co-Authors

Avatar

Paola A. Mello

Universidade Federal de Santa Maria

View shared research outputs
Researchain Logo
Decentralizing Knowledge