Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Carlo de Asmundis is active.

Publication


Featured researches published by Carlo de Asmundis.


Circulation-arrhythmia and Electrophysiology | 2009

Inferior and Lateral Electrocardiographic Repolarization Abnormalities in Brugada Syndrome

Andrea Sarkozy; Gian-Battista Chierchia; Gaetano Paparella; Tim Boussy; Carlo de Asmundis; Marcus Roos; Stefan Henkens; Leonard Kaufman; Ronald Buyl; Ramon Brugada; Josep Brugada; Pedro Brugada

Background—Repolarization abnormalities in the inferior-lateral leads in Brugada syndrome (BS) have not been systematically investigated. Methods and Results—280 patients (age, 41±18 years; 168 males) with BS were screened for inferior-lateral repolarization abnormalities. The repolarization abnormalities were classified either as early repolarization pattern or coved ≥2-mm Brugada pattern and as spontaneous or class I antiarrhythmic drug (AAD) induced. Thirty-two patients (11%) had inferior-lateral spontaneous early repolarization pattern. These patients were less likely to be asymptomatic at first presentation (13 of 32 versus 156 of 248 patients, P=0.02), and spontaneous type I ECG was more frequent among them (38% versus 21%, P=0.05). The spontaneous early repolarization pattern occurred more frequently among patients with BS than in 283 family members not having BS (11% versus 6%, P=0.03). Class I AAD administration provoked inferior-lateral coved Brugada pattern in 13 patients with BS. These patients had longer baseline PR intervals (206±48 versus 172±31 ms, P<0.001) and class I AAD–induced QRS interval prolongation (108 to 178 versus 102 ms to 131 ms, P<0.001). In 3 patients, the class I AAD–provoked coved Brugada pattern was only present in the inferior leads. Conclusions—Inferior-lateral early repolarization pattern occurs spontaneously relatively frequently in BS. These patients have a more severe phenotype. Class I AAD administration provokes inferior-lateral coved Brugada pattern in 4.6% of patients. We report for the first time 3 patients in whom the class I AAD–provoked coved Brugada pattern was only observed in the inferior leads.


Journal of Cardiovascular Electrophysiology | 2014

One‐Year Follow‐Up After Single Procedure Cryoballoon Ablation: A Comparison Between the First and Second Generation Balloon

Giacomo Di Giovanni; Kristel Wauters; Gian-Battista Chierchia; Juan Sieira; Moises Levinstein; Giulio Conte; Carlo de Asmundis; Giannis Baltogiannis; Yukio Saitoh; Giuseppe Ciconte; Justo Juliá; Giacomo Mugnai; Ghazala Irfan; Pedro Brugada

With respect to the first generation Cryoballoon (CB), the second generation (Cryoballoon Advance [CB‐A], Medtronic, Minneapolis, MN, USA) was designed with technical modifications resulting in a larger and more uniform zone of freezing on the balloons surface aiming at procedural outcome improvement in the setting of atrial fibrillation (AF) ablation. However, a comparison between both technologies on a midterm follow‐up is missing in todays literature.


Europace | 2014

Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up.

Gian-Battista Chierchia; Giacomo Di Giovanni; Giuseppe Ciconte; Carlo de Asmundis; Giulio Conte; Juan Sieira-Moret; Moisés Rodríguez-Mañero; Ruben Casado; Giannis Baltogiannis; Mehdi Namdar; Yukio Saitoh; Gaetano Paparella; Giacomo Mugnai; Pedro Brugada

BACKGROUND The novel cryoballoon Advance (CB-A) has proven to achieve significantly lower temperatures and faster pulmonary vein isolation (PVI) times in comparison with the first-generation device. Although acutely very effective, to the best of our knowledge, data on mid-term clinical follow-up is lacking. AIMS The aim of the study was to analyse the freedom from recurrence of atrial fibrillation (AF) on a 1-year follow-up period, in a series of consecutive patients having undergone PVI with the CB-A for paroxysmal AF (PAF). METHODS AND RESULTS Forty-two patients [30 male (71%); mean age: 57.9 ± 21.1 years] were included. All patients underwent a procedure with the large 28 mm CB-A. A total 168 PVs were depicted on the pre-procedural computed tomography scan. All PVs (100%) could be isolated with the CB only. The freedom from AF off-antiarrhythmic drug treatment after a single procedure was 78% of patients at a mean 11.6 ± 2.0 months follow-up. If considering a blanking period (BP) of 3 months, success rate was 83%. Phrenic nerve palsy (PNP) was the most frequent complication occurring in 19% of individuals. CONCLUSION The CB-A is very effective in producing PVI and affords freedom from AF at 12 months follow-up in 83% of patients affected by drug-resistant PAF following a 3-month BP. The most frequent complication observed was PNP which occurred in 19% of patients. All PNP reverted during follow-up.


Heart Rhythm | 2013

Phrenic nerve paralysis during cryoballoon ablation for atrial fibrillation: A comparison between the first- and second-generation balloon

Ruben Casado-Arroyo; Gian-Battista Chierchia; Giulio Conte; Moises Levinstein; Juan Sieira; Moisés Rodríguez-Mañero; Giacomo Di Giovanni; Yannis Baltogiannis; Kristel Wauters; Carlo de Asmundis; Andrea Sarkozy; Pedro Brugada

BACKGROUND Phrenic nerve palsy (PNP) is the most frequently observed complication during cryoballoon ablation (CB; Arctic Front, Medtronic, MN) occurring in roughly 7%-9% of the cases. The new second-generation cryoballoon ablation Arctic Front Advance (CB-A) (Arctic Front) has recently been launched in the market. OBJECTIVE To evaluate the incidence of right PNP with the new CB-A in comparison with the first-generation balloon in a series of consecutive patients that underwent pulmonary vein isolation with this modality. METHODS The study was designed as an observational study with a prospective follow-up. In total, 121 consecutive patients were included: 80 patients with the CB (group 1) and 41 with the CB-A (group 2). RESULTS Mean procedural times, fluoroscopic times, and time to pulmonary vein isolation documented by real-time recordings were significantly lower in group 2 (P ≤ .05). The occurrence of PNP was significantly higher in group 2 (6.25% [5 of 80] in group 1 vs 19.5% [8 of 41] in group 2; P = .033). At 7 months, PNP persisted in 1 (2.5%) patient in the CB-A group. CONCLUSIONS Right PNP seems to occur in a significantly larger number of patients with the second-generation CB-A. However, this complication is reversible in nearly all cases on short-term follow-up. More refined phrenic nerve monitoring during right-sided pulmonary vein ablation and less vigorous wedging maneuvers in the pulmonary vein ostia might significantly reduce the occurrence of this complication.


Journal of the American College of Cardiology | 2015

Implantable Cardioverter-Defibrillator Therapy in Brugada Syndrome: A 20-Year Single-Center Experience

Giulio Conte; Juan Sieira; Giuseppe Ciconte; Carlo de Asmundis; Gian-Battista Chierchia; Giannis Baltogiannis; Giacomo Di Giovanni; Mark La Meir; Francis Wellens; Jens Czapla; Kristel Wauters; Moises Levinstein; Yukio Saitoh; Ghazala Irfan; Justo Juliá; Gudrun Pappaert; Pedro Brugada

BACKGROUND Patients with Brugada syndrome and aborted sudden cardiac death or syncope have higher risks for ventricular arrhythmias (VAs) and should undergo implantable cardioverter-defibrillator (ICD) placement. Device-based management of asymptomatic patients is controversial. ICD therapy is associated with high rates of inappropriate shocks and device-related complications. OBJECTIVES The objective of this study was to investigate clinical features, management, and long-term follow-up of ICD therapy in patients with Brugada syndrome. METHODS Patients presenting with spontaneous or drug-induced Brugada type 1 electrocardiographic findings, who underwent ICD implantation and continuous follow-up at a single institution, were eligible for this study. RESULTS A total of 176 consecutive patients were included. During a mean follow-up period of 83.8 ± 57.3 months, spontaneous sustained VAs occurred in 30 patients (17%). Eight patients (4.5%) died. Appropriate ICD shocks occurred in 28 patients (15.9%), and 33 patients (18.7%) had inappropriate shocks. Electrical storm occurred in 4 subjects (2.3%). Twenty-eight patients (15.9%) experienced device-related complications. In multivariate Cox regression analysis, aborted sudden cardiac death and VA inducibility on electrophysiologic studies were independent predictors of appropriate shock occurrence. CONCLUSIONS ICD therapy was an effective strategy in Brugada syndrome, treating potentially lethal arrhythmias in 17% of patients during long-term follow-up. Appropriate shocks were significantly associated with the presence of aborted sudden cardiac death but also occurred in 13% of asymptomatic patients. Risk stratification by electrophysiologic study may identify asymptomatic patients at risk for arrhythmic events and could be helpful in investigating syncope not related to VAs. ICD placement is frequently associated with device-related complications, and rates of inappropriate shocks remain high regardless of careful device programming.


Europace | 2015

Comparison between radiofrequency with contact force-sensing and second-generation cryoballoon for paroxysmal atrial fibrillation catheter ablation: a multicentre European evaluation

Fabien Squara; Alexandre Zhao; Eloi Marijon; Decebal Gabriel Latcu; Rui Providência; Giacomo Di Giovanni; Gaël Jauvert; François Jourda; Gian-Battista Chierchia; Carlo de Asmundis; Giuseppe Ciconte; Christine Alonso; Caroline Grimard; Serge Boveda; Bruno Cauchemez; Nadir Saoudi; Pedro Brugada; Jean Paul Albenque; Olivier Thomas

AIMS Whether pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) using contact force (CF)-guided radiofrequency (RF) or second-generation cryoballoon (CB) present similar efficacy and safety remains uncertain. METHODS AND RESULTS We performed a multicentre study comparing procedural safety and arrhythmia recurrence after standardized PVI catheter ablation for PAF using CF-guided RF ablation (Thermocool(®) SmartTouch™, Biosense Webster; or Tacticath™, St Jude Medical) (CF group) with second-generation CB ablation (Arctic Front Advance™, Medtronic) (CB group). Overall, 376 patients (mean age 59.8 ± 10.4 years, 280 males) were enrolled in 4 centres: 198 in CF group and 178 in CB group. Procedure was shorter for CB group than for CF group (109.6 ± 40 vs. 122.5 ± 40.7 min, P = 0.003), but fluoroscopy duration and X-ray exposure were not statistically different (P = 0.1 and P = 0.22, respectively). Overall complication rate was similar in both groups: 14 (7.1%) in the CF group vs. 13 (7.3%) in the CB group (P = 0.93). However, transient right phrenic nerve palsy occurred only in CB group (10 patients, 5.6%; P = 0.001 vs. CF group) and severe non-lethal complications (embolic event, tamponade, or oesophageal injury) occurred only in CF group (5 patients, 2.5%; P = 0.03 vs. CB group). No periprocedural death occurred in either group. Single-procedure freedom from any atrial arrhythmias at 18 months post-ablation was comparable in CF group and CB group (76 vs. 73.3%, respectively, log rank P = 0.63). CONCLUSION Pulmonary vein isolation using CF-guided RF and second-generation CB leads to comparable single-procedure arrhythmia-free survival at up to 18 months with similar overall complication rate.


Heart Rhythm | 2015

Pulmonary vein isolation as index procedure for persistent atrial fibrillation: One-year clinical outcome after ablation using the second-generation cryoballoon

Giuseppe Ciconte; Luca Ottaviano; Carlo de Asmundis; Giannis Baltogiannis; Giulio Conte; Juan Sieira; Giacomo Di Giovanni; Yukio Saitoh; Ghazala Irfan; Giacomo Mugnai; Cesare Storti; Annibale Sandro Montenero; Gian-Battista Chierchia; Pedro Brugada

BACKGROUND No data are available about the clinical outcome of pulmonary vein isolation (PVI) as an index procedure for persistent atrial fibrillation (PersAF) ablation using the second-generation cryoballoon (CB-Adv). OBJECTIVE The purpose of this study was to assess the 1-year efficacy of PVI as an index procedure for PersAF ablation using the novel CB-Adv. METHODS Sixty-three consecutive patients (45 male [71.4%], mean age 62.7 ± 9.7 years) with drug-refractory PersAF undergoing PVI using the novel CB-Adv were enrolled. Follow-up was based on outpatient clinic visits including Holter ECGs. Recurrence of atrial tachyarrhythmias (ATas) was defined as a symptomatic or documented episode >30 seconds. RESULTS A total of 247 PVs were identified and successfully isolated with a mean of 1.7 ± 0.4 freezes. Mean procedural and fluoroscopy times were 87.1 ± 38.2 minutes and 14.9 ± 6.1 minutes, respectively. Among 26 of 63 patients (41.3%) presenting with AF at the beginning of the procedure, 7 of 26 (26.9%) converted to sinus rhythm during ablation. Phrenic nerve palsy occurred in 4 of 63 patients (6.3%). At 1-year follow-up, after a 3-month blanking period (BP), 38 of 63 patients (60.3%) were in sinus rhythm. Because of ATa recurrences, 9 patients underwent a second procedure with radiofrequency ablation showing a pulmonary vein reconnection in 4 right-sided PVs (44.4%) and 3 left-sided PVs (33.3%). Multivariate analysis demonstrated that PersAF duration (P = .01) and relapses during BP (P = .04) were independent predictors of AT recurrences. CONCLUSION At 1-year follow-up, freedom from ATas following PersAF ablation with the novel CB-Adv is 60%. Phrenic nerve palsy is the most common complication. PersAF duration and relapses during the BP appear to be significant predictors of arrhythmic recurrences.


European Heart Journal | 2011

The value of a family history of sudden death in patients with diagnostic type I Brugada ECG pattern

Andrea Sarkozy; Antonio Sorgente; Tim Boussy; Ruben Casado; Gaetano Paparella; Lucio Capulzini; Gian-Battista Chierchia; Yoshinao Yazaki; Carlo de Asmundis; Danny Coomans; Josep Brugada; Pedro Brugada

AIMS We sought to investigate the value of a family history of sudden death (SD) in Brugada syndrome (BS). METHODS AND RESULTS Two hundred and eighty consecutive patients (mean age: 41 ± 18 years, 168 males) with diagnostic type I Brugada ECG pattern were included. Sudden death occurred in 69 (43%) of 157 families. One hundred and ten SDs were analysed. During follow-up VF (ventricular fibrillation) or SD-free survival rate was not different between patients with or without a family history of SD of a first-degree relative, between patients with or without a family history of multiple SD of a first-degree relative at any age and between patients with or without a family history of SD in first-degree relatives ≤35 years. One patient had family history of SD of two first-degree relative ≤35 years with arrhythmic event during follow-up. In univariate analysis male gender (P = 0.01), aborted SD (P < 0.001), syncope (P = 0.04), spontaneous type I ECG (P < 0.001), and inducibility during electrophysiological (EP) study (P < 0.001) were associated with worse prognosis. The absence of syncope, aborted SD, spontaneous type I ECG, and inducibility during EP study was associated with a significantly better prognosis (P < 0.001). CONCLUSION Family history of SD is not predictive for future arrhythmic events even if considering only SD in first-degree relatives or SD in first-degree relatives at a young age. The absence of syncope, aborted SD, spontaneous type I ECG, and inducibility during EP study is associated with a good five-year prognosis.


Europace | 2015

Circumferential pulmonary vein isolation as index procedure for persistent atrial fibrillation: a comparison between radiofrequency catheter ablation and second-generation cryoballoon ablation

Giuseppe Ciconte; Giannis Baltogiannis; Carlo de Asmundis; Juan Sieira; Giulio Conte; Giacomo Di Giovanni; Yukio Saitoh; Ghazala Irfan; Giacomo Mugnai; Burak Hünük; Gian-Battista Chierchia; Pedro Brugada

AIMS To assess the 1 year efficacy of pulmonary vein isolation (PVI) as index procedure for persistent atrial fibrillation (PersAF) comparing conventional radiofrequency irrigated-tip catheter ablation (RFCA) using contact-force technology and ablation using the second-generation cryoballoon (CB-AdvA). METHODS AND RESULTS One hundred consecutive patients (74 male, 74%; mean age 62.4 ± 9.6 years) with drug-refractory PersAF undergoing PVI using RFCA and CB-AdvA were enrolled. Follow-up was based on outpatient clinic visits including Holter-electrocardiograms. Recurrence of atrial tachyarrhythmias (ATas) was defined as a symptomatic or documented episode >30 s. Among 100 patients, 50 underwent RFCA whereas 50 CB-AdvA. Mean procedure and fluoroscopy times were 90.5 ± 41.7 vs. 140.2 ± 46.9 min and 14.5 ± 6.6 vs. 19.8 ± 6.8 min in the CB-Adv and in the RFCA group, respectively (P < 0.01). At 1 year follow-up, after a 3 months blanking period (BP), freedom from ATas off-drugs after a single procedure was 60% (28/50 patients) in the CB-Adv and 56% (27/50 patients) in the RFCA group (P = 0.71). Multivariate analysis demonstrated that PersAF duration (P = 0.01) and relapses during BP (P = 0.02) were independent predictors of ATa recurrences following the index procedure. CONCLUSION Freedom from ATas following PersAF ablation with RFCA and CB-Adv is comparable at 1 year follow-up after a single procedure. Ablation with the CB-Adv is associated with shorter procedure time and radiation exposure as compared with RFCA. Atrial tachyarrhythmias occurrence during BP and longer time of PersAF seem to be significant predictors of arrhythmia recurrences after the index procedure.


Europace | 2008

Early recovery of pulmonary vein conduction after cryoballoon ablation for paroxysmal atrial fibrillation: a prospective study

Gian-Battista Chierchia; Carlo de Asmundis; Stephan-Andreas Müller-Burri; Andrea Sarkozy; Lucio Capulzini; Gaetano Paparella; Sergio Chierchia; Markus Roos; Pedro Brugada

AIMS To assess the incidence of early pulmonary vein (PV) reconnection, characterize the anatomic features of the reconducting veins, and analyse the time course of their recovery in a series of consecutive patients with paroxysmal atrial fibrillation (AF) undergoing ablation with the Arctic Front Cryoballoon. METHODS AND RESULTS We prospectively enrolled 26 patients (20 males; age 55.4 +/- 4.1) for circumferential PV cryoballoon isolation for highly symptomatic paroxysmal AF. Following isolation of all veins, we analysed PV potentials in each vein after 30 and 60 min with a circular mapping catheter. After successful electrical isolation of all 104 PVs, recurrence was observed only in three veins (2.8%) after 30 min. Two further cryoballoon applications in each of these veins lead to their isolation. These veins were still electrically disconnected at 60 min. No PV reconnection was observed in any of the other 101 veins (97.1%) at 30 and 60 min. CONCLUSION Cryoballoon ablation of the PVs ostia is a very effective technique to achieve electrical isolation, with a very low rate of early reconnection.

Collaboration


Dive into the Carlo de Asmundis's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Pedro Brugada

Vrije Universiteit Brussel

View shared research outputs
Top Co-Authors

Avatar

Giacomo Mugnai

Vrije Universiteit Brussel

View shared research outputs
Top Co-Authors

Avatar

Erwin Ströker

Vrije Universiteit Brussel

View shared research outputs
Top Co-Authors

Avatar

Juan Sieira

Vrije Universiteit Brussel

View shared research outputs
Top Co-Authors

Avatar

Andrea Sarkozy

Vrije Universiteit Brussel

View shared research outputs
Top Co-Authors

Avatar

Giulio Conte

Vrije Universiteit Brussel

View shared research outputs
Top Co-Authors

Avatar

Giuseppe Ciconte

Vrije Universiteit Brussel

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge