Carlos A. Munoz
Loma Linda University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Carlos A. Munoz.
Journal of Prosthodontics | 2003
Guillermo Bernal; Mitsunobu Okamura; Carlos A. Munoz
PURPOSE The purpose of this study was to compare the effect of 20 degrees and 30 degrees of total occlusal convergence (TOC), the occlusocervical dimension, and the type of cement on the tensile resistance to dislodgement of cement-retained, implant-supported restorations. MATERIALS AND METHODS Cylindrical preparations with TOC angles of 20 degrees and 30 degrees and occlusocervical dimensions of 4 mm (S) and 8 mm (L) were made through a machining process. The cylinders had a shoulder finish line of 1.0 mm in depth. Eight impressions were made of each machined cylinder and poured in type IV dental stone, for a total of 32 dies. Die spacer was applied to each die. A master wax pattern was designed, and the 32 wax patterns were marginated, invested, and cast in type IV gold alloy (n = 8). The gold crowns were cemented with Flecks cement (zinc phosphate cement), Temp-Bond (zinc oxide eugenol cement), Temp-Bond plus Vaseline (30% by weight), and IMProv temporary cement (acrylic/urethane cement) under a 10-kg load and placed in a humidor at 37 degrees C for 1 hour before testing. A uniaxial tensile force was applied to the crown using an Instron machine with a crosshead speed of 5 mm/min until cement failure occurred. Analysis of variance models were fit to determine the effect of TOC, occlusocervical dimension, and cement type of the restorations on the mean tensile strength. RESULTS For each type of cement, the mean tensile strengths were significantly higher at 20 degrees of TOC and 8 mm of occlusocervical dimension compared with the other preparations. At this preparation, IMProv had the highest mean tensile resistance to dislodgement (47.7 +/- 8.4 kg), followed by Flecks (38.2 +/- 8.8 kg), Temp-Bond (35.9 +/- 4.4 kg), and Temp-Bond plus Vaseline (8.2 +/- 2.2 kg). No statistically significant difference was observed between Temp-Bond and Flecks zinc phosphate cement when 20 degrees of TOC and 8 mm of occlusocervical dimension was used. There was no statistical difference in the mean tensile resistance to dislodgement for Temp-Bond plus Vaseline with different preparation designs (p > 0.05) except when 20 degrees of TOC and 8 mm of occlusocervical dimension was used. The mean tensile strength was significantly different between Temp-Bond and Temp-Bond plus Vaseline for each of the 4 preparation designs (p < 0.05). Among the cements tested, IMProv exhibited higher values, which were statistically different (p < 0.05). Restorations with greater occlusocervical dimension and less TOC exhibited higher tensile resistance to dislodgement. CONCLUSIONS Preparations with 20 degrees of TOC and 8 mm of occlusocervical dimension had significantly higher mean retentive values for all of the cements tested. Significant differences in mean tensile strength were observed, with the highest tensile resistance seen with IMProv, followed by Flecks cement, and the lowest tensile resistance seen with Temp-Bond plus Vaseline.
Journal of Prosthetic Dentistry | 1998
Kathrine R. Eldridge; Sonja F. Finnie; Joni Stephens; Amable M. Mauad; Carlos A. Munoz; James D. Kettering
STATEMENT OF PROBLEM Antimicrobial mouthrinses have become an important part of comprehensive dental care. However, mouthrinses that contain alcohol have been shown to be detrimental to patients undergoing radiation therapy for head and neck cancer, to some immunocompromised patients, to families with small children, and to persons sensitive to alcohol. PURPOSE This study evaluated the effectiveness of alcohol-free, 0.12% chlorhexidine mouthrinse in reducing microbial levels when compared with commercially available 0.12% chlorhexidine (CHX) and essential oils mouthrinses. MATERIAL AND METHODS This study consisted of both in vitro and in vivo investigations. The double-blind study included 32 subjects randomly assigned to 3 groups, equalized according to the indices tested. One group (n = 11) received essential oils rinse; the second group (n = 11) received CHX; and the last group (n = 10) received the alcohol-free CHX. Subjects were asked not to use any mechanical means of oral hygiene for 21 days. The in vitro part of the study consisted of Streptococcus mutans strip tests. RESULTS Mean plaque scores for both CHX products decreased after 21 days, whereas the mean for the essential oils increased. Bleeding and gingival index scores for all 3 groups increased, which may be due to the initially healthy tissues of the participants. Relative microbial growth for S mutans for both the CHX products decreased to 0 after 21 days, whereas the counts for the essential oils group remained varied.
Journal of Endodontics | 2003
Tanya K. Machnick; Mahmoud Torabinejad; Carlos A. Munoz; Shahrokh Shabahang
The purpose of this study was to evaluate the effect of MTAD on the flexural strength and modulus of elasticity of dentin. Dentin bars were randomly assigned to eight groups treated with various concentrations of NaOCl (5.25%, 2.65%, 1.31%, 0.66%), 17% EDTA, MTAD, saline, or according to a clinical protocol with 1.3% NaOCl and then 5 min of MTAD. Specimens were subjected to flexural strength and modulus of elasticity tests. Two-sample t test (alpha = 0.05) showed no statistically significant differences between various groups except for a reduction in flexural strength for the 2-h MTAD group (p = 0.002) and the EDTA group (p = 0.002). A significant reduction of modulus of elasticity for the 2-h MTAD group (p < 0.001), EDTA group (p < 0.001), and 0.6% NaOCl (p < 0.002) also was noted. There was no significant difference in flexural strength and modulus of elasticity between the dentin bars exposed to saline or MTAD when applied according to the clinical protocol (p > 0.05). These results indicate that MTAD can be used as prescribed for clinical use without affecting the physical properties of the dentin.
Journal of Prosthetic Dentistry | 1996
Michio Ito; Toshio Yamagishi; Yoshiki Oshida; Carlos A. Munoz
This study evaluated the relationship between flow characteristics, bending strength, and softening temperature of paraffin and dental inlay waxes to casting shrinkage when patterns were invested with a phosphate-bonded investment. This study found that the casting shrinkage decreased as the flow of the wax pattern increased. If a low flow wax is used or if there is a need for a thick pattern, the size of the casting ring should be increased. When wax patterns are formed for cast restorations, it is important to select the type of wax with the most desirable properties for the margin and the occlusal portions. Moreover, to accurately fabricate castings, it is necessary to understand the physical properties of the chosen waxes.
Bio-medical Materials and Engineering | 1993
Yoshiki Oshida; Carlos A. Munoz; Mark M. Winkler; Azza Hashem; Michio Itoh
Aluminum oxide particles are commonly used as a sandblasting media, particularly in dentistry, for multiple purposes including divesting the casting investment materials and increasing effective surface area for enhancing the mechanical retention strengths of succeedingly applied fired porcelain or luting cements. Usually fine aluminum oxide particles are recycled within the sandblasting machine. Ceramics such as aluminum oxides are brittle, therefore, some portions of recycling aluminum oxide particles might be brittle fractured. If fractured sandblasting particles are involved in the recycling media, it might result in irregularity metallic materials surface as well as the recycling sandblasting media itself be contaminated. Hence, it is necessary from both clinical and practical reasons to monitor the particle conditions in terms of size/shape and effectiveness of sandblasting, so that sandblasting dental prostheses can be fabricated in optimum and acceptable conditions. In the present study, the effect of recycling aluminum oxide particles on the surface texture of metallic materials was evaluated by Fractal Dimension Analysis (FDA). Every week the alumina powder was sampled and analyzed for weight fraction and contaminants. Surface texture of sandblasted standard samples was also characterized by FDA. Results indicate very little change in particle size, while the fractal dimension increased. Fractal dimension analysis showed that the aluminum oxide particle as a sandblasting media should be replaced after 30 or 40 min of total accumulated operation time.
Journal of Endodontics | 2003
Tanya K. Machnick; Mahmoud Torabinejad; Carlos A. Munoz; Shahrokh Shabahang
The purpose of this study was to compare the effect of MTAD (a mixture of a tetracycline isomer [doxycycline], an acid [citric acid], and a detergent [Tween 80]) and phosphoric acid on the bond strength to enamel and dentin using a conventional OptiBond Solo Plus dentin adhesive system. One hundred flat surfaces (50 enamel/50 dentin) were prepared for bonding. Specimens were embedded in acrylic with the flat surface exposed. One of the following surface treatments was applied before bonding composite with Optibond Solo Plus (Kerr Corp): 1 min NaOCl/1 min EDTA; 1 min NaOCl/1 min MTAD; 30 s etch with H3PO4 (positive control), 2 min saline (negative control), or 20 min NaOCl/5 min MTAD (clinical protocol for MTAD). Shear bond strength was tested 30 min after bonding. Data were analyzed using a one-way ANOVA followed by the Student-Newman-Keuls multiple comparison method. Surface pretreatment with acid etch resulted in the greatest enamel bond strengths (p < 0.05). All surface pretreatments were superior to saline for dentinal bonding (p < 0.05). On the basis of our findings, it appears that teeth endodontically treated with the MTAD protocol for clinical use (20 min 1.3% NaOCl/5 min MTAD) may not need any additional dentin conditioning before the application of the dental adhesive.
Journal of Prosthetic Dentistry | 1995
Mark W. Wilhelm; Carl J. Andres; David T. Brown; Carlos A. Munoz
This study compared the effects of repeated microwave oven and double-boiler liquefactions and prolonged autoduplicator storage on four physical properties of one reversible hydrocolloid duplicating material. No significant differences were observed between the linear dimensional change and detail reproduction of the three liquefaction techniques. Tear strength differences most clearly distinguished the techniques and effects of aging. Fifteen double-boiler remeltings produced tear strength values lower than those recorded for material stored in an autoduplicator for 2 weeks. Thirty microwave melting cycles still produced tear strength values equivalent to that of the autoduplicator material. After 30 melting cycles the compressive strengths of the microwave and double-boiler materials were inferior to that of the stored autoduplicator material.
International Journal of Prosthodontics | 1990
Friedlander Ld; Carlos A. Munoz; Charles J. Goodacre; Doyle Mg; Moore Bk
International Journal of Prosthodontics | 2002
Owens Eg; Goodacre Cj; Loh Pl; Hanke G; Okamura M; Jo Kh; Carlos A. Munoz; Naylor Wp
International Journal of Prosthodontics | 1991
Panichuttra R; Jones Rm; Charles J. Goodacre; Carlos A. Munoz; Moore Bk