Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Carlos Eduardo Rochitte is active.

Publication


Featured researches published by Carlos Eduardo Rochitte.


The New England Journal of Medicine | 2008

Diagnostic Performance of Coronary Angiography by 64-Row CT

Julie M. Miller; Carlos Eduardo Rochitte; Marc Dewey; Armin Arbab-Zadeh; Hiroyuki Niinuma; Ilan Gottlieb; Narinder Paul; Melvin E. Clouse; Edward P. Shapiro; John Hoe; Albert C. Lardo; David E. Bush; Albert de Roos; Christopher Cox; Jeffery Brinker; Abstr Act

BACKGROUND The accuracy of multidetector computed tomographic (CT) angiography involving 64 detectors has not been well established. METHODS We conducted a multicenter study to examine the accuracy of 64-row, 0.5-mm multidetector CT angiography as compared with conventional coronary angiography in patients with suspected coronary artery disease. Nine centers enrolled patients who underwent calcium scoring and multidetector CT angiography before conventional coronary angiography. In 291 patients with calcium scores of 600 or less, segments 1.5 mm or more in diameter were analyzed by means of CT and conventional angiography at independent core laboratories. Stenoses of 50% or more were considered obstructive. The area under the receiver-operating-characteristic curve (AUC) was used to evaluate diagnostic accuracy relative to that of conventional angiography and subsequent revascularization status, whereas disease severity was assessed with the use of the modified Duke Coronary Artery Disease Index. RESULTS A total of 56% of patients had obstructive coronary artery disease. The patient-based diagnostic accuracy of quantitative CT angiography for detecting or ruling out stenoses of 50% or more according to conventional angiography revealed an AUC of 0.93 (95% confidence interval [CI], 0.90 to 0.96), with a sensitivity of 85% (95% CI, 79 to 90), a specificity of 90% (95% CI, 83 to 94), a positive predictive value of 91% (95% CI, 86 to 95), and a negative predictive value of 83% (95% CI, 75 to 89). CT angiography was similar to conventional angiography in its ability to identify patients who subsequently underwent revascularization: the AUC was 0.84 (95% CI, 0.79 to 0.88) for multidetector CT angiography and 0.82 (95% CI, 0.77 to 0.86) for conventional angiography. A per-vessel analysis of 866 vessels yielded an AUC of 0.91 (95% CI, 0.88 to 0.93). Disease severity ascertained by CT and conventional angiography was well correlated (r=0.81; 95% CI, 0.76 to 0.84). Two patients had important reactions to contrast medium after CT angiography. CONCLUSIONS Multidetector CT angiography accurately identifies the presence and severity of obstructive coronary artery disease and subsequent revascularization in symptomatic patients. The negative and positive predictive values indicate that multidetector CT angiography cannot replace conventional coronary angiography at present. (ClinicalTrials.gov number, NCT00738218.)


Journal of the American College of Cardiology | 2010

Prognostic Significance of Myocardial Fibrosis Quantification by Histopathology and Magnetic Resonance Imaging in Patients With Severe Aortic Valve Disease

Clerio F. Azevedo; Marcelo Nigri; Maria de Lourdes Higuchi; Pablo Maria Alberto Pomerantzeff; Guilherme Sobreira Spina; Roney Orismar Sampaio; Flávio Tarasoutchi; Max Grinberg; Carlos Eduardo Rochitte

OBJECTIVES We sought to determine whether the quantitative assessment of myocardial fibrosis (MF), either by histopathology or by contrast-enhanced magnetic resonance imaging (ce-MRI), could help predict long-term survival after aortic valve replacement. BACKGROUND Severe aortic valve disease is characterized by progressive accumulation of interstitial MF. METHODS Fifty-four patients scheduled to undergo aortic valve replacement were examined by ce-MRI. Delayed-enhanced images were used for the quantitative assessment of MF. In addition, interstitial MF was quantified by histological analysis of myocardial samples obtained during open-heart surgery and stained with picrosirius red. The ce-MRI study was repeated 27+/-22 months after surgery to assess left ventricular functional improvement, and all patients were followed for 52+/-17 months to evaluate long-term survival. RESULTS There was a good correlation between the amount of MF measured by histopathology and by ce-MRI (r=0.69, p<0.001). In addition, the amount of MF demonstrated a significant inverse correlation with the degree of left ventricular functional improvement after surgery (r=-0.42, p=0.04 for histopathology; r=-0.47, p=0.02 for ce-MRI). Kaplan-Meier analyses revealed that higher degrees of MF accumulation were associated with worse long-term survival (chi-square=6.32, p=0.01 for histopathology; chi-square=5.85, p=0.02 for ce-MRI). On multivariate Cox regression analyses, patient age and the amount of MF were found to be independent predictors of all-cause mortality. CONCLUSIONS The amount of MF, either by histopathology or by ce-MRI, is associated with the degree of left ventricular functional improvement and all-cause mortality late after aortic valve replacement in patients with severe aortic valve disease.


European Heart Journal | 2014

Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography: the CORE320 study

Carlos Eduardo Rochitte; Richard T. George; Marcus Y. Chen; Armin Arbab-Zadeh; Marc Dewey; Julie M. Miller; Hiroyuki Niinuma; Kunihiro Yoshioka; Kakuya Kitagawa; Shiro Nakamori; Roger J. Laham; Andrea L. Vavere; Rodrigo J. Cerci; Vishal C. Mehra; Cesar Nomura; Klaus F. Kofoed; Masahiro Jinzaki; Sachio Kuribayashi; Albert de Roos; Michael Laule; Swee Yaw Tan; John Hoe; Narinder Paul; Frank J. Rybicki; Jeffery Brinker; Andrew E. Arai; Christopher Cox; Melvin E. Clouse; Marcelo F. Di Carli; Joao A.C. Lima

AIMS To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed tomography (SPECT). METHODS AND RESULTS We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon emission computed tomography (SPECT/MPI). Sixteen centres enroled 381 patients who underwent combined CTA-CTP and SPECT/MPI prior to conventional coronary angiography. All four image modalities were analysed in blinded independent core laboratories. The prevalence of obstructive CAD defined by combined ICA-SPECT/MPI and ICA alone was 38 and 59%, respectively. The patient-based diagnostic accuracy defined by the area under the receiver operating characteristic curve (AUC) of integrated CTA-CTP for detecting or excluding flow-limiting CAD was 0.87 [95% confidence interval (CI): 0.84-0.91]. In patients without prior myocardial infarction, the AUC was 0.90 (95% CI: 0.87-0.94) and in patients without prior CAD the AUC for combined CTA-CTP was 0.93 (95% CI: 0.89-0.97). For the combination of a CTA stenosis ≥50% stenosis and a CTP perfusion deficit, the sensitivity, specificity, positive predictive, and negative predicative values (95% CI) were 80% (72-86), 74% (68-80), 65% (58-72), and 86% (80-90), respectively. For flow-limiting disease defined by ICA-SPECT/MPI, the accuracy of CTA was significantly increased by the addition of CTP at both the patient and vessel levels. CONCLUSIONS The combination of CTA and perfusion correctly identifies patients with flow limiting CAD defined as ≥50 stenosis by ICA causing a perfusion defect by SPECT/MPI.


Journal of the American College of Cardiology | 2010

The Absence of Coronary Calcification Does Not Exclude Obstructive Coronary Artery Disease or the Need for Revascularization in Patients Referred for Conventional Coronary Angiography

Ilan Gottlieb; Julie M. Miller; Armin Arbab-Zadeh; Marc Dewey; Melvin E. Clouse; Leonardo Sara; Hiroyuki Niinuma; David E. Bush; Narinder Paul; Andrea L. Vavere; John Texter; Jeffery Brinker; Joao A.C. Lima; Carlos Eduardo Rochitte

OBJECTIVES This study was designed to evaluate whether the absence of coronary calcium could rule out >or=50% coronary stenosis or the need for revascularization. BACKGROUND The latest American Heart Association guidelines suggest that a calcium score (CS) of zero might exclude the need for coronary angiography among symptomatic patients. METHODS A substudy was made of the CORE64 (Coronary Evaluation Using Multi-Detector Spiral Computed Tomography Angiography Using 64 Detectors) multicenter trial comparing the diagnostic performance of 64-detector computed tomography to conventional angiography. Patients clinically referred for conventional angiography were asked to undergo a CS scan up to 30 days before. RESULTS In all, 291 patients were included, of whom 214 (73%) were male, and the mean age was 59.3 +/- 10.0 years. A total of 14 (5%) patients had low, 218 (75%) had intermediate, and 59 (20%) had high pre-test probability of obstructive coronary artery disease. The overall prevalence of >or=50% stenosis was 56%. A total of 72 patients had CS = 0, among whom 14 (19%) had at least 1 >or=50% stenosis. The overall sensitivity for CS = 0 to predict the absence of >or=50% stenosis was 45%, specificity was 91%, negative predictive value was 68%, and positive predictive value was 81%. Additionally, revascularization was performed in 9 (12.5%) CS = 0 patients within 30 days of the CS. From a total of 383 vessels without any coronary calcification, 47 (12%) presented with >or=50% stenosis; and from a total of 64 totally occluded vessels, 13 (20%) had no calcium. CONCLUSIONS The absence of coronary calcification does not exclude obstructive stenosis or the need for revascularization among patients with high enough suspicion of coronary artery disease to be referred for coronary angiography, in contrast with the published recommendations. Total coronary occlusion frequently occurs in the absence of any detectable calcification. (Coronary Evaluation Using Multi-Detector Spiral Computed Tomography Angiography Using 64 Detectors [CORE-64]; NCT00738218).


Journal of the American College of Cardiology | 2012

Diagnostic Accuracy of CT Coronary Angiography According to Pretest Probability of Coronary Artery Disease and Severity of Coronary Arterial Calcification: The CorE-64 International, Multicenter Study

Armin Arbab-Zadeh; Julie M. Miller; Carlos Eduardo Rochitte; Marc Dewey; Hiroyuki Niinuma; Ilan Gottlieb; Narinder Paul; Melvin E. Clouse; Edward P. Shapiro; John Hoe; Albert C. Lardo; David E. Bush; Albert de Roos; Christopher Cox; Jeffrey A. Brinker; Joăo A.C. Lima

OBJECTIVES The purpose of this study was to assess the impact of patient population characteristics on accuracy by computed tomography angiography (CTA) to detect obstructive coronary artery disease (CAD). BACKGROUND The ability of CTA to exclude obstructive CAD in patients of different pre-test probabilities and in presence of coronary calcification remains uncertain. METHODS For the CORE-64 (Coronary Artery Evaluation Using 64-Row Multidetector Computed Tomography Angiography) study, 371 patients underwent CTA and cardiac catheterization for the detection of obstructive CAD, defined as ≥50% luminal stenosis by quantitative coronary angiography (QCA). This analysis includes 80 initially excluded patients with a calcium score ≥600. Area under the receiver-operating characteristic curve (AUC) was used to evaluate CTA diagnostic accuracy compared to QCA in patients according to calcium score and pre-test probability of CAD. RESULTS Analysis of patient-based quantitative CTA accuracy revealed an AUC of 0.93 (95% confidence interval [CI]: 0.90 to 0.95). The AUC remained 0.93 (95% CI: 0.90 to 0.96) after excluding patients with known CAD but decreased to 0.81 (95% CI: 0.71 to 0.89) in patients with calcium score ≥600 (p = 0.077). While AUCs were similar (0.93, 0.92, and 0.93, respectively) for patients with intermediate, high pre-test probability for CAD, and known CAD, negative predictive values were different: 0.90, 0.83, and 0.50, respectively. Negative predictive values decreased from 0.93 to 0.75 for patients with calcium score <100 or ≥100, respectively (p = 0.053). CONCLUSIONS Both pre-test probability for CAD and coronary calcium scoring should be considered before using CTA for excluding obstructive CAD. For that purpose, CTA is less effective in patients with calcium score ≥600 and in patients with a high pre-test probability for obstructive CAD.


European Radiology | 2009

Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64

Julie M. Miller; Marc Dewey; Andrea L. Vavere; Carlos Eduardo Rochitte; Hiroyuki Niinuma; Armin Arbab-Zadeh; Narinder Paul; John Hoe; Albert de Roos; Kunihiro Yoshioka; Pedro A. Lemos; David E. Bush; Albert C. Lardo; John Texter; Jeffery Brinker; Christopher Cox; Melvin E. Clouse; Joao A.C. Lima

Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective “CORE-64” trial (“Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors”). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows.


American Journal of Cardiology | 2010

Dipyridamole stress and rest myocardial perfusion by 64-detector row computed tomography in patients with suspected coronary artery disease.

Roberto Caldeira Cury; Tiago Augusto Magalhães; Anna C. Borges; Afonso Akio Shiozaki; Pedro A. Lemos; José Soares Júnior; José Cláudio Meneghetti; Ricardo C. Cury; Carlos Eduardo Rochitte

Recently, stress myocardial computed tomographic perfusion (CTP) was shown to detect myocardial ischemia. Our main objective was to evaluate the feasibility of dipyridamole stress CTP and compare it to single-photon emission computed tomography (SPECT) to detect significant coronary stenosis using invasive conventional coronary angiography (CCA; stenosis >70%) as the reference method. Thirty-six patients (62 +/- 8 years old, 20 men) with previous positive results with SPECT (<2 months) as the primary inclusion criterion and suspected coronary artery disease underwent a customized multidetector-row CT protocol with myocardial perfusion evaluation at rest and during stress and coronary CT angiography (CTA). Multidetector-row computed tomography was performed in a 64-slice scanner with dipyridamole stress perfusion acquisition before a second perfusion/CT angiographic acquisition at rest. Independent blinded observers performed analysis of images from CTP, CTA, and CCA. All 36 patients completed the CT protocol with no adverse events (mean radiation dose 14.7 +/- 3.0 mSv) and with interpretable scans. CTP results were positive in 27 of 36 patients (75%). From the 9 (25%) disagreements, 6 patients had normal coronary arteries and 2 had no significant stenosis (8 false-positive results with SPECT, 22%). The remaining patient had an occluded artery with collateral flow confirmed by conventional coronary angiogram. Good agreement was demonstrated between CTP and SPECT on a per-patient analysis (kappa 0.53). In 26 patients using CCA as reference, sensitivity, specificity, and positive and negative predictive values were 88.0%, 79.3%, 66.7%, and 93.3% for CTP and 68.8, 76.1%, 66.7%, and 77.8%, for SPECT, respectively (p = NS). In conclusion, dipyridamole CT myocardial perfusion at rest and during stress is feasible and results are similar to single-photon emission CT scintigraphy. The anatomical-perfusion information provided by this combined CT protocol may allow identification of false-positive results by SPECT.


Journal of the American College of Cardiology | 2012

Diagnostic accuracy of computed tomography coronary angiography according to pre-test probability of coronary artery disease and severity of coronary arterial calcification: The CORE-64 (Coronary Artery Evaluation Using 64-Row Multidetector Computed Tomography Angiography) international multicenter study

Armin Arbab-Zadeh; Julie M. Miller; Carlos Eduardo Rochitte; Marc Dewey; Hiroyuki Niinuma; Ilan Gottlieb; Narinder Paul; Melvin E. Clouse; Edward P. Shapiro; John Hoe; Albert C. Lardo; David E. Bush; Albert de Roos; Christopher Cox; Jeffrey A. Brinker; Joăo A.C. Lima

OBJECTIVES The purpose of this study was to assess the impact of patient population characteristics on accuracy by computed tomography angiography (CTA) to detect obstructive coronary artery disease (CAD). BACKGROUND The ability of CTA to exclude obstructive CAD in patients of different pre-test probabilities and in presence of coronary calcification remains uncertain. METHODS For the CORE-64 (Coronary Artery Evaluation Using 64-Row Multidetector Computed Tomography Angiography) study, 371 patients underwent CTA and cardiac catheterization for the detection of obstructive CAD, defined as ≥50% luminal stenosis by quantitative coronary angiography (QCA). This analysis includes 80 initially excluded patients with a calcium score ≥600. Area under the receiver-operating characteristic curve (AUC) was used to evaluate CTA diagnostic accuracy compared to QCA in patients according to calcium score and pre-test probability of CAD. RESULTS Analysis of patient-based quantitative CTA accuracy revealed an AUC of 0.93 (95% confidence interval [CI]: 0.90 to 0.95). The AUC remained 0.93 (95% CI: 0.90 to 0.96) after excluding patients with known CAD but decreased to 0.81 (95% CI: 0.71 to 0.89) in patients with calcium score ≥600 (p = 0.077). While AUCs were similar (0.93, 0.92, and 0.93, respectively) for patients with intermediate, high pre-test probability for CAD, and known CAD, negative predictive values were different: 0.90, 0.83, and 0.50, respectively. Negative predictive values decreased from 0.93 to 0.75 for patients with calcium score <100 or ≥100, respectively (p = 0.053). CONCLUSIONS Both pre-test probability for CAD and coronary calcium scoring should be considered before using CTA for excluding obstructive CAD. For that purpose, CTA is less effective in patients with calcium score ≥600 and in patients with a high pre-test probability for obstructive CAD.


American Journal of Roentgenology | 2011

Diagnostic Performance of Combined Noninvasive Coronary Angiography and Myocardial Perfusion Imaging Using 320-MDCT: The CT Angiography and Perfusion Methods of the CORE320 Multicenter Multinational Diagnostic Study

Richard T. George; Armin Arbab-Zadeh; Rodrigo J. Cerci; Andrea L. Vavere; Kakuya Kitagawa; Marc Dewey; Carlos Eduardo Rochitte; Andrew E. Arai; Narinder Paul; Frank J. Rybicki; Albert C. Lardo; Melvin E. Clouse; Joao A.C. Lima

OBJECTIVE Coronary MDCT angiography has been shown to be an accurate noninvasive tool for the diagnosis of obstructive coronary artery disease (CAD). Its sensitivity and negative predictive value for diagnosing percentage of stenosis are unsurpassed compared with those of other noninvasive testing methods. However, in its current form, it provides no information regarding the physiologic impact of CAD and is a poor predictor of myocardial ischemia. CORE320 is a multicenter multinational diagnostic study with the primary objective to evaluate the diagnostic accuracy of 320-MDCT for detecting coronary artery luminal stenosis and corresponding myocardial perfusion deficits in patients with suspected CAD compared with the reference standard of conventional coronary angiography and SPECT myocardial perfusion imaging. CONCLUSION We aim to describe the CT acquisition, reconstruction, and analysis methods of the CORE320 study.


Radiology | 2011

Coronary Artery Stenoses: Accuracy of 64–Detector Row CT Angiography in Segments with Mild, Moderate, or Severe Calcification—A Subanalysis of the CORE-64 Trial

Andrea L. Vavere; Armin Arbab-Zadeh; Carlos Eduardo Rochitte; Marc Dewey; Hiroyuki Niinuma; Ilan Gottlieb; Melvin E. Clouse; David E. Bush; John Hoe; Albert de Roos; Christopher Cox; Joao A.C. Lima; Julie M. Miller

PURPOSE To evaluate the influence of cross-sectional arc calcification on the diagnostic accuracy of computed tomography (CT) angiography compared with conventional coronary angiography for the detection of obstructive coronary artery disease (CAD). MATERIALS AND METHODS Institutional Review Board approval and written informed consent were obtained from all centers and participants for this HIPAA-compliant study. Overall, 4511 segments from 371 symptomatic patients (279 men, 92 women; median age, 61 years [interquartile range, 53-67 years]) with clinical suspicion of CAD from the CORE-64 multicenter study were included in the analysis. Two independent blinded observers evaluated the percentage of diameter stenosis and the circumferential extent of calcium (arc calcium). The accuracy of quantitative multidetector CT angiography to depict substantial (≥ 50%) stenoses was assessed by using quantitative coronary angiography (QCA). Cross-sectional arc calcium was rated on a segment level as follows: noncalcified or mild (< 90°), moderate (90°-180°), or severe (> 180°) calcification. Univariable and multivariable logistic regression, receiver operation characteristic curve, and clustering methods were used for statistical analyses. RESULTS A total of 1099 segments had mild calcification, 503 had moderate calcification, 338 had severe calcification, and 2571 segments were noncalcified. Calcified segments were highly associated (P < .001) with disagreement between CTA and QCA in multivariable analysis after controlling for sex, age, heart rate, and image quality. The prevalence of CAD was 5.4% in noncalcified segments, 15.0% in mildly calcified segments, 27.0% in moderately calcified segments, and 43.0% in severely calcified segments. A significant difference was found in area under the receiver operating characteristic curves (noncalcified: 0.86, mildly calcified: 0.85, moderately calcified: 0.82, severely calcified: 0.81; P < .05). CONCLUSION In a symptomatic patient population, segment-based coronary artery calcification significantly decreased agreement between multidetector CT angiography and QCA to detect a coronary stenosis of at least 50%.

Collaboration


Dive into the Carlos Eduardo Rochitte's collaboration.

Top Co-Authors

Avatar

Joao A.C. Lima

Johns Hopkins University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Pedro A. Lemos

University of São Paulo

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge