Caroline Brusselmans
Katholieke Universiteit Leuven
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Caroline Brusselmans.
European Journal of Internal Medicine | 2013
Etienne Joosten; Pieter Lioen; Caroline Brusselmans; Christophe Indevuyst; Nancy Boeckx
BACKGROUND Iron deficiency anaemia (IDA) and anaemia of chronic disease (ACD) are common in elderly patients but there are no standard diagnostic criteria. The reticulocyte haemoglobin equivalent (Ret-He) is routinely measured by modern automated blood analysers and is an early indicator of iron deficiency. The aim of this study was to investigate whether the Ret-He level as calculated by the Sysmex XE-5000 automated blood analyser is a useful parameter for the diagnosis of IDA in a geriatric hospitalized population. METHODS In a prospective study, blood samples were collected in 26 geriatric patients with IDA and 111 patients with ACD diagnosed according to generally accepted laboratory and clinical criteria. A blood count including Ret-He, mean corpuscular volume (MCV), mean corpuscular haemoglobin (MCH), mean corpuscular haemoglobin concentration (MCHC) and standard iron parameters was performed in each patient. RESULTS Haemoglobin, Ret-He, MCV, MCH and MCHC levels were all significantly lower in IDA as compared to ACD patients. However, the area under the curve (AUC) was greater for MCH (0.87, 95% CI 0.78-0.95) and MCHC (0.86, 95% CI 0.76-0.96) then for Ret-He (0.828, 95% CI 0.73-0.93) and MCV (0.80, 95% CI 0.68-0.91). A Ret-He cut-off value of 26 pg had a sensitivity and specificity based on its optimal combination of 85% and 69% respectively. CONCLUSION Analysis of Ret-He does not perform better than the classical red cell indices such as MCH and MCHC in differentiating IDA and ACD in geriatric patients.
The Journal of Allergy and Clinical Immunology | 2016
Leen Moens; Glynis Frans; Barbara Bosch; Xavier Bossuyt; Bert Verbinnen; Willy Poppe; Nancy Boeckx; Mary Slatter; Caroline Brusselmans; George A. Diaz; Thomas Tousseyn; Helena Flipts; Anniek Corveleyn; Daan Dierickx; Isabelle Meyts
Please cite this article as: Moens L, Frans G, Bosch B, Bossuyt X, Verbinnen B, Poppe W, Boeckx N, Slatter M, Brusselmans C, Diaz G, Tousseyn T, Flipts H, Corveleyn A, Dierickx D, Meyts I, Successful hematopoietic stem cell transplantation for myelofibrosis in an adult with WartsHypogammaglobulinemia-Immunodeficiency-Myelokathexis syndrome, Journal of Allergy and Clinical Immunology (2016), doi: 10.1016/j.jaci.2016.04.057.
American Journal of Clinical Pathology | 2016
Toon Schiemsky; Caroline Brusselmans; Elke Nackers; Pieter Vermeersch; Koen Poesen; Koen Desmet; Nancy Boeckx; Davy Kieffer
OBJECTIVES We evaluated the performance of a novel capillary isoelectric focusing (CIEF) application for hemoglobinopathy screening on the recently introduced V8 E-Class platform. METHODS Analytical performance of the V8 E-Class was evaluated and included assessment of hemoglobin A2 (HbA2) imprecision; linearity for HbA2, fetal hemoglobin (HbF), and sickle hemoglobin (HbS); and carryover for HbS. Furthermore, a method comparison with the Minicap Flex Piercing (Sebia, Lisses, France), the Variant Classic (Bio-Rad Laboratories, Hercules, CA), and the G8 (Tosoh Europe, Amsterdam, the Netherlands) was done to assess analytical and clinical concordance. RESULTS Total HbA2 imprecision was 3.26% and 3.14% for normal and elevated HbA2 controls and 5.16% and 3.58% for a normal and a heterozygous HbS patient sample, respectively. HbA2, HbF, and HbS showed acceptable linearity, and no carryover was observed. The method comparison showed good analytical concordance (r > 0.95) except for a homozygous HbS subset (r = 0.532-0.704). A comparable phenomenon was seen for the clinical concordance with good agreement in samples without variants (weighted κ > 0.80) but poorer agreement in HbS samples (κ < 0.30). CONCLUSIONS Good analytical performance was demonstrated for this novel CIEF application for hemoglobinopathy screening. Method comparison showed generally good correlation but highlights the need for standardization. Finally, software optimization could further add to its use for routine hemoglobinopathy screening.
Acta Clinica Belgica | 2002
L Ide; A Dekoninck; Estelle Verburgh; Willy Goossens; Caroline Brusselmans; Nancy Boeckx; Marie-Paule Emonds; Philippe Vandekerckhove
Abstract We present a case of persistent polyclonal B-cell lymphocytosis (PPBL). This syndrome is characterized by a persistent lymphocytosis with circulating atypical binucleated lymphocytes. The patient had serological evidence of a previous EBV infection, had raised polyclonal serum IgM levels and was a heavy smoker. No malignancy was detected.
Annals of Hematology | 2012
Natalie Put; Katrien Van Roosbroeck; Peter Konings; Peter Meeus; Caroline Brusselmans; Katrina Rack; Carine Gervais; Elise Chapiro; Isabelle Radford-Weiss; Stéphanie Struski; Nicole Dastugue; Nathalie Gachard; Christine Lefebvre; Carole Barin; Virginie Eclache; Sandra Fert-Ferrer; Sophy Laibe; Mj Mozziconacci; Benoît Quilichini; Hélène Poirel; Iwona Wlodarska; Anne Hagemeijer; Yves Moreau; Peter Vandenberghe; Lucienne Michaux
Pediatric Blood & Cancer | 2004
Nancy Boeckx; Anne Uyttebroeck; Anton W. Langerak; Caroline Brusselmans; Willy Goossens; Xavier Bossuyt
Archive | 2011
Peter Vandenberghe; Els Lierman; Karolien Beel; Nancy Boeckx; Caroline Brusselmans; Sarah Deleu; Tom Bos
Archive | 2011
Daan Dierickx; M Criel; Caroline Brusselmans; Michel Delforge; Timothy Devos; Johan Maertens; Hélène Schoemans; Gregor Verhoef
Archive | 2010
A Cortoos; Caroline Brusselmans; Rene Westhovens; An Moonen; Marc Boogaerts; Michel Delforge; Timothy Devos; Ann Janssens; Johan Maertens; Stef Meers; Hélène Schoemans; Gregor Verhoef; Daan Dierickx
Archive | 2010
G Mertens; Gregor Verhoef; Caroline Brusselmans; Marc Boogaerts; Michel Delforge; Timothy Devos; Ann Janssens; Johan Maertens; Stef Meers; Hélène Schoemans; Daan Dierickx