Cédric Luyet
University of Bern
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Cédric Luyet.
Anesthesiology | 2009
Lorenz Theiler; M. Kleine-Brueggeney; Dagmar Kaiser; Natalie Urwyler; Cédric Luyet; Andreas Vogt; Robert Greif; M.M.E. Unibe
Background:The single-use supraglottic airway devices LMA-Supreme™ (LMA-S™; Laryngeal Mask Company, Henley-on-Thames, United Kingdom) and i-gel™ (Intersurgical Ltd, Wokingham, Berkshire, United Kingdom) have a second tube for gastric tube insertion. Only the LMA-S™ has an inflatable cuff. They have the same clinical indications and might be useful for difficult airway management. This prospective, crossover, randomized controlled trial was performed in a simulated difficult airway scenario using an extrication collar limiting mouth opening and neck movement. Methods:Sixty patients were included. Both devices were placed in random order in each patient. Primary outcome was overall success rate. Other measurements were time to successful ventilation, airway leak pressure, fiberoptic glottic view, and adverse events. Results:Success rate for the LMA-S™ was 95% versus 93% for the i-gel™ (P = 1.000). LMA-S™ needed shorter insertion time (34 ± 12 s vs. 42 ± 23 s, P = 0.024). Tidal volumes and airway leak pressure were similar (LMA-S™ 26 ± 8 cm H20; i-gel™ 27 ± 9 cm H20; P = 0.441). Fiberoptic view through the i-gel™ showed less epiglottic downfolding. Overall agreement in insertion outcome was 54 (successes) and 1 (failure) or 55 (92%) of 60 patients. The difference in success rate was 1.7% (95% CI –11.3% to 7.6%). Conclusions:Both airway devices had similar insertion success and clinical performance in the simulated difficult airway situation. The authors found less epiglottic downfolding and better fiberoptic view but longer insertion time with the i-gel™. Our study shows that both devices are feasible for emergency airway management in patients with reduced neck movement and limited mouth opening.
BJA: British Journal of Anaesthesia | 2009
Cédric Luyet; Urs Eichenberger; Robert Greif; Andreas Vogt; Z. Szücs Farkas; Bernhard Moriggl
BACKGROUND During paravertebral block, the anterolateral limit of the paravertebral space, which consists of the pleura, should preferably not be perforated. Also it is possible that, during the block, the constant superior costotransverse ligament can be missed in the loss-of-resistance technique. We therefore aimed to develop a new technique for an ultrasound-guided puncture of the paravertebral space. METHODS We performed 20 punctures and catheter placements in 10 human cadavers. A sonographic view showing the pleura and the superior costotransverse ligament was obtained with a slightly oblique scan using a curved array transducer. After inline approach, injection of 10 ml normal saline confirmed the correct position of the needle tip, distended the space, and enabled catheter insertion. The spread of contrast dye injected through the catheters was assessed by CT scans. RESULTS The superior costotransverse ligament and the paravertebral space were easy to identify. The needle tip reached the paravertebral space without problems under visualization. In contrast, the introduction of the catheter was difficult. The CT scan revealed a correct paravertebral spread of contrast in 11 cases. Out of the remaining, one catheter was found in the pleural space, in six cases there was an epidural, and in two cases there was a prevertebral spread of contrast dye. CONCLUSIONS We successfully developed a technique for an accurate ultrasound-guided puncture of the paravertebral space. We also showed that when a catheter is introduced through the needle with the tip lying in the paravertebral space, there is a high probability of catheter misplacement into the epidural, mediastinal, or pleural spaces.
BJA: British Journal of Anaesthesia | 2011
Cédric Luyet; Gudrun Herrmann; Steffen Ross; Andreas Vogt; Robert Greif; Bernhard Moriggl; Urs Eichenberger
BACKGROUND Paravertebral regional anaesthesia is used to treat pain after several surgical procedures. This study aimed to improve on our first published ultrasound-guided approach to the paravertebral space (PVS) and to investigate a possible discrepancy between the needle, catheter, and contrast dye position. METHODS In 10 cadavers, we conducted 26 ultrasound-guided paravertebral approaches combined with loss of resistance (LOR) and after an interim analysis performed 36 novel, pure ultrasound-guided (PUSG) paravertebral approaches. Needle-tip position was controlled by a first computed tomography (CT) scan. After placement of the catheters, the tips were assessed by a second CT and the spread of injected contrast dye was assessed by further CT scans. The part of the PVS near the intervertebral foramen was defined as the primary target to reach. RESULTS The first CT scans assessing 62 needle tips revealed that: 13 (50%) of LOR and 34 (94%) of PUSG approaches were at the target; and two (8%) LOR and no PUSG approaches were outside the PVS. With the second CT scans 60 catheter-tip positions were analysed: three (12%) of LOR and five (14%) of PUSG approaches were at the target, three (12%) of LOR and two (6%) of PUSG approaches were outside the PVS. No catheters were detected in the epidural space. In two cases, insertion of the catheter was not possible. In cases with major epidural contrast, the widest contrast dye spread was 7.7 (3.5) [mean (sd)] vertebral segments. CONCLUSIONS Our new PUSG technique has a high success rate for paravertebral needle placement. Although needles were correctly positioned, catheters were usually found distant from the needle-tip position.
BJA: British Journal of Anaesthesia | 2011
Lorenz Theiler; M. Kleine-Brueggeney; Natalie Urwyler; T. Graf; Cédric Luyet; Robert Greif
BACKGROUND The single-use supraglottic airway device i-gel™ has been described in several case reports as a conduit for intubation, but no prospective data about success rates of blind intubation are available. Therefore, we performed this prospective randomized controlled trial to compare the success rate of blind tracheal intubation with a Magill PVC tube through the i-gel™ with intubation using an sILMA™ PVC tube through the single-use intubating laryngeal mask airway (sILMA™). METHODS With ethics committee approval and written informed consent, 80 patients with predictors of a difficult airway were computer randomized to either supraglottic airway device (SAD). The corresponding tracheal tube (TT) was introduced through the SAD under fibreoptic visualization but without fibreoptic guidance. Primary outcome was blind intubation success rate. Times, airway leak pressure, fibreoptic view, and adverse events were recorded. To control for the influence of the TT, we compared data from 40 patients described in an accompanying study (sILMA™ with Magill TT and i-gel™ with sILMA™ TT). RESULTS Blind intubation success rate through the sILMA™ (69%) was higher than with the i-gel™ (15%, P<0.001). Data from the other patient group excluded the TT type as the primary cause for the difference in success rate. Removal of SADs was without problems with no difference between the type of SAD. CONCLUSIONS Blind tracheal intubation using the sILMA™ tube through the sILMA™ is much more successful than blind intubation with a Magill PVC tube through the i-gel™. Because of its low success rate, we would not recommend blind intubation through the i-gel™.
BJA: British Journal of Anaesthesia | 2011
M. Kleine-Brueggeney; Robert Greif; Steffen Ross; Urs Eichenberger; Bernhard Moriggl; A. Arnold; Cédric Luyet
BACKGROUND Ultrasound-guided techniques are increasingly used in anaesthetic practice to identify tissues beneath the skin and to increase the accuracy of placement of needles close to targeted structures. To examine ultrasounds usefulness for dilatational tracheostomy, we performed ultrasound-guided tracheal punctures in human cadavers followed by computer-tomographic (CT) control. METHODS The trachea of nine cadavers was punctured using an in-plane approach with a longitudinal ultrasound visualization of the trachea. As soon as a loss of resistance was felt, or air/fluid could be aspirated into the attached syringe, the syringe was disconnected and the ultrasound transducer set aside. Thereafter, a cricothyroidotomy guidewire was inserted through the needle into the trachea. The needle was then removed, leaving the wire in place and a control CT imaging of the neck and the chest was performed. Primary outcome was successful wire insertion into the trachea. RESULTS Tracheal puncture and wire insertion was successful in eight of nine cadavers at the first attempt and in one at the second attempt (total of 10 puncture attempts, nine successful). In eight of nine successfully inserted wires, the wire was placed on the defined midline. CONCLUSIONS Ultrasound guidance can facilitate successful tracheal puncture. However, combining an in-plane approach with a longitudinal ultrasound visualization of the trachea neither guarantees an exact midline puncture nor allows detection of a misplaced guidewire.
Anesthesiology Research and Practice | 2013
P. H. Conroy; Cédric Luyet; C. J. McCartney; Paul McHardy
Identification of the subarachnoid space has traditionally been achieved by either a blind landmark-guided approach or using prepuncture ultrasound assistance. To assess the feasibility of performing spinal anaesthesia under real-time ultrasound guidance in routine clinical practice we conducted a single center prospective observational study among patients undergoing lower limb orthopaedic surgery. A spinal needle was inserted unassisted within the ultrasound transducer imaging plane using a paramedian approach (i.e., the operator held the transducer in one hand and the spinal needle in the other). The primary outcome measure was the success rate of CSF acquisition under real-time ultrasound guidance with CSF being located in 97 out of 100 consecutive patients within median three needle passes (IQR 1–6). CSF was not acquired in three patients. Subsequent attempts combining landmark palpation and pre-puncture ultrasound scanning resulted in successful spinal anaesthesia in two of these patients with the third patient requiring general anaesthesia. Median time from spinal needle insertion until intrathecal injection completion was 1.2 minutes (IQR 0.83–4.1) demonstrating the feasibility of this technique in routine clinical practice.
BJA: British Journal of Anaesthesia | 2008
Cédric Luyet; Urs Eichenberger; Bernhard Moriggl; L. Remonda; Robert Greif
BACKGROUND Retrobulbar anaesthesia allows eye surgery in awake patients. Severe complications of the blind techniques are reported. Ultrasound-guided needle introduction and direct visualization of the spread of local anaesthetic may improve quality and safety of retrobulbar anaesthesia. Therefore, we developed a new ultrasound-guided technique using human cadavers. METHODS In total, 20 blocks on both sides in 10 embalmed human cadavers were performed. Using a small curved array transducer and a long-axis approach, a 22 G short bevel needle was introduced under ultrasound guidance lateral and caudal of the eyeball until the needle tip was seen 2 mm away from the optic nerve. At this point, 2 ml of contrast dye as a substitute for local anaesthetic was injected. Immediately after the injection, the spread of the contrast dye was documented by means of CT scans performed in each cadaver. RESULTS The CT scans showed the distribution of the contrast dye in the muscle cone and behind the posterior sclera in all but one case. No contrast dye was found inside the optic nerve or inside the eyeball. In one case, there could be an additional trace of contrast dye behind the orbita. CONCLUSIONS Our new ultrasound-guided technique has the potential to improve safety and efficacy of the procedure by direct visualization of the needle placement and the distribution of the injected fluid. Furthermore, the precise injection near the optic nerve could lead to a reduction of the amount of the local anaesthetic needed with fewer related complications.
Veterinary Anaesthesia and Analgesia | 2013
Ute Morath; Cédric Luyet; Claudia Spadavecchia; Michael Hubert Stoffel; Garry M Hatch
OBJECTIVE To develop an ultrasound-guided technique for retrobulbar nerve block in horses, and to compare the distribution of three different volumes of injected contrast medium (CM) (4, 8 and 12 mL), with the hypothesis that successful placement of the needle within the retractor bulbi muscle cone would lead to the most effective dispersal of CM towards the nerves leaving the orbital fissure. STUDY DESIGN Prospective experimental cadaver study. ANIMALS Twenty equine cadavers. METHODS Ultrasound-guided retrobulbar injections were performed in 40 cadaver orbits. Ultrasound visualization of needle placement within the retractor bulbi muscle cone and spread of injected CM towards the orbital fissure were scored. Needle position and destination of CM were then assessed using computerized tomography (CT), and comparisons performed between ultrasonographic visualization of orbital structures and success rate of injections (intraconal needle placement, CM reaching the orbital fissure). RESULTS Higher scores for ultrasound visualization resulted in a higher success rate for intraconal CM injection, as documented on the CT images. Successful intraconal placement of the needle (22/34 orbits) resulted in CM always reaching the orbital fissure. CM also reached the orbital fissure in six orbits where needle placement was extraconal. With 4, 8 and 12 mL CM, the orbital fissure was reached in 16/34, 23/34 and 28/34 injections, respectively. CONCLUSION AND CLINICAL RELEVANCE The present study demonstrates the use of ultrasound for visualization of anatomical structures and needle placement during retrobulbar injections in equine orbits. However, this approach needs to be repeated in controlled clinical trials to assess practicability and effectiveness in clinical practice.
Anaesthesia | 2012
Cédric Luyet; C Meyer; Gudrun Herrmann; Gary M. Hatch; Steffen Ross; Urs Eichenberger
There are conflicting results with regard to the use of catheter‐based techniques for continuous paravertebral block. Local anaesthetic spread within the paravertebral space is limited and the clinical effect is often variable. Discrepancies between needle tip position and final catheter position can also be problematic. The aim of this proof‐of‐concept study was to assess the reliability of placing a newly developed coiled catheter in human cadavers. Sixty Tuohy needles and coiled catheters were placed under ultrasound guidance, three on each side of the thoracic vertebral column in 10 human cadavers. Computed tomography was used to assess needle tip and catheter tip locations. No catheter was misplaced into the epidural, pleural or prevertebral spaces. The mean (SD) distance between catheter tips and needle tips was 8.2 (4.9) mm. The median (IQR [range]) caudo‐cephalad spread of contrast dye injectate through a subset of 20 catheters was 4 (4–5[3–8]) thoracic segments. All catheters were removed without incident. Precise paravertebral catheter placement can be achieved using ultrasound‐guided placement of a coiled catheter.
Regional Anesthesia and Pain Medicine | 2012
Cédric Luyet; Kenneth T. Eng; Peter J. Kertes; A. Avila; Rajeev H. Muni; Paul McHardy
Background and Objectives The aims of this prospective observational study were to assess the incidence of intraconal spread during peribulbar (extraconal) anesthesia by real-time ultrasound imaging of the retro-orbital compartment and to determine whether a complete sensory and motor block (with akinesia) of the eye is directly related to the intraconal spread. Methods Ultrasound imaging was performed in 100 patients who underwent a surgical procedure on the posterior segment of the eye. All patients received a peribulbar block using the inferolateral approach. Once the needle was in place, a linear ultrasound transducer was placed over the eyelid and the spread of local anesthetics was assessed during the injection (real time). Akinesia was assessed by a blinded observer 10 minutes after block placement. The incidence of intraconal spread and its correlation with a complete akinesia was measured. Results The overall block failure rate was 28% in terms of akinesia, and the rate of rescue blocks was 20%. Clear intraconal spread during injection of the local anesthetic mixture could be detected with ultrasound imaging in 61 of 100 patients. The positive predictive value for successful block when intraconal spread was detected was 98% (95% confidence interval, 91%-100%). The association between clear and no evidence of intraconal spread and effective block was statistically significant (&khgr;2 test, P < 0.001). Conclusions Ultrasound imaging provides information of local anesthetic spread within the retro-orbital space, which might assist in the prediction of block success.