Celal Akdeniz
Istanbul University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Celal Akdeniz.
Digestive and Liver Disease | 2008
Tugcin Bora Polat; Nafiye Urganci; Yalim Yalcin; Cenap Zeybek; Celal Akdeniz; Abdullah Erdem; Elnur Imanov; Ahmet Çelebi
BACKGROUND The identification of a coeliac disease in patients with idiopathic dilated cardiomyopathy raises critical questions on the relationship between the two entities. But cardiac functions have not been studied in patients with coeliac disease. The present study was undertaken to assess cardiac functions by Tissue Doppler Echocardiography in patient with coeliac disease. METHODS We studied 45 clinically stable patients; twenty-five patients with positive serum IgA Antiendomysial Antibody levels (Group 1), twenty patients with negative serum IgA Antiendomysial Antibody levels (Group 2) at the time of echocardiographic study. Control group consisted of 30 healthy children free of any disease. RESULTS Myocardial systolic wave velocity of the mitral annulus was significantly lower (p<0.001), myocardial precontraction and contraction time were slightly longer in Group 2 when compared control group (p=0.015, p=0.044, respectively). There was a negative correlation between the serum IgA Antiendomysial Antibody levels titers and myocardial systolic wave levels of all patients included in the study (r = -0.633; p<0.001). A myocardial systolic wave velocity of <8.9 cm/s had a 92% sensitivity and 80% specificity in predicting serum IgA Antiendomysial Antibody levels positive patients. CONCLUSIONS We detected subclinical systolic dysfunction of the left ventricle in children with coeliac disease in whom serum IgA Antiendomysial Antibody reactivity is prominent. Tissue Doppler echocardiography provides a quantifiable indicator useful for cardiac monitoring of disease during follow up.
Pediatrics International | 2010
Cenap Zeybek; Ahmet Çelebi; Cigdem Aktuglu-Zeybek; Yalim Yalcin; Abdullah Erdem; Celal Akdeniz; Elnur Imanov; Suheyla Altay; Ahmet Aydin
Background: This study was conducted to evaluate left ventricle (LV) functions using conventional and tissue Doppler imaging in childhood obesity and to identify the effects of diet on LV diastolic functions.
Pediatrics International | 2007
Cenap Zeybek; Yalim Yalcin; Abdullah Erdem; Tugcin Bora Polat; A. Çiğdem Aktuğlu-Zeybek; Veysel Bayoglu; Celal Akdeniz; Ahmet Çelebi
Background: The aim of the present study was to evaluate the role of tissue Doppler echocardiography in assessment of ventricular function in pediatric patients with bronchial asthma (BA).
Catheterization and Cardiovascular Interventions | 2013
Turkay Saritas; Mehmet Gungor Kaya; Yat Yin Lam; Abdullah Erdem; Celal Akdeniz; Fadli Demir; Nurdan Erol; Halil Demir; Ahmet Çelebi
Aim: We sought to investigate the safety and efficacy of Cardio‐O‐Fix septal occluder (CSO) in percutaneous closure of atrial septal defects (ASD) as compared to the Amplatzer septal occluder (ASO). Methods: A consecutive of 351 patients received transcatheter ASD closure with CSO or ASO from July 2004 to October 2010 were studied. The ASDs were divided into simple‐ (isolated defects <26 mm) or complex‐types (isolated defect ≥26 mm, double or multifenestrated defects). The procedures were guided by fluoroscopy and transthoracic or transesophageal echocardiography. Clinical and echocardiographic follow‐ups were arranged before discharge, at 1 month and then every 6‐month after implantation. Results: During the study period, 185 (125 males, aged 18.5 ± 15.6 years) and 166 (103 males, aged 21.0 ± 15.7 years) patients attempted CSO and ASO implants, respectively. The CSO group had similar ASD and device sizes, prevalence of complex lesions (17 vs. 16%, P = 0.796), procedural times and success rates (97% vs. 96%, P = 0.635) as compared to the ASO group. Acute residual shunts were less prevalent in CSO than ASO group and most shunts closed spontaneously at 6‐month follow‐ups. The average equipment cost per patient was lower in CSO group (US
Catheterization and Cardiovascular Interventions | 2010
Tugcin Bora Polat; Ahmet Çelebi; Sevim Hacımahmutoğlu; Celal Akdeniz; Abdullah Erdem; Fatih Fırat
4,100 vs. US
Cardiology in The Young | 2006
Tugcin Bora Polat; Yalim Yalcin; Celal Akdeniz; Cenap Zeybek; Abdullah Erdem; Ahmet Çelebi
5,900, P < 0.001). The prevalence of device embolization and atrial arrhythmia (all <2%) were similar in both patient groups. Conclusion: Transcatheter ASD occlusion with CSO is safe and effective and it appeared to be an attractive alternative to ASO in closing simple‐type ASD because of its relatively low cost.
Pediatrics International | 2015
Yakup Ergül; Ibrahim Cansaran Tanidir; Isa Ozyilmaz; Celal Akdeniz; Volkan Tuzcu
Background: Reduced left lung perfusion has been described after transcatheter closure of the patent ductus arteriosus (PDA) with several prostheses. Although the Amplatzer ductal occluder (ADO) device is currently the most widely used occluder for closure of large‐sized PDAs, the potential consequences of flow distribution to the lungs of this device have not been completely clarified. We evaluated lung perfusion following occlusion of PDA with the ADO device. Methods: Forty‐seven patients underwent successful transcatheter PDA occlusion using the ADO device were included in this study. Lung perfusion scans were performed 6 months after the procedure. Results: Decreased perfusion to the left lung (defined as < 40% of total lung flow) was observed in 17 patients (36%), 5 of whom were low‐weight symptomatic infants. Ductal ampulla length was significantly shorter and minimal ductal diameter to ampulla diameter ratio was significantly higher in patients with decreased left lung perfusion and correlated well with left lung perfusion values (r = 0.516 and r = −0.501, respectively). A cut‐off value of ≤5.8 mm for the ductal ampulla length and ≥1.9 for ampulla diameter to ampulla length ratio showed high sensitivity and specificity for reduced lung perfusion. Conclusions: The incidence of abnormal left lung perfusion is high 6 months after transcatheter closure of PDA with the ADO, more likely in the low weight symptomatic infants and in patients with a short duct or a relatively shallow duct having abrupt narrowing of a large ampulla.
Cardiology in The Young | 2014
Isa Ozyilmaz; Yakup Ergül; Celal Akdeniz; Erkut Ozturk; Ibrahim Cansaran Tanidir; Tuzcu
BACKGROUND Disturbances of conduction are well known in the setting of acute rheumatic fever. The aim of this study is to investigate the QT dispersion as seen in the surface electrocardiogram of children with acute rheumatic fever. METHODS QT dispersion was quantitatively evaluated in 88 children with acute rheumatic fever. Patients were divided into two groups based on the absence or presence of carditis. As a control group, we studied 36 healthy children free of any disease, and matched for age with both groups. Repeat echocardiographic examinations were routinely scheduled in all patients at 3 months after the initial attack to study the evolution of valvar lesions. RESULTS The mean QT dispersion was significantly higher in children with rheumatic carditis. But there was no statistical difference between children without carditis and normal children. Among the children with carditis, the mean dispersion was higher in those with significant valvar regurgitation. Dispersion of greater than 55 milliseconds had a sensitivity of 85%, and specificity of 70%, in predicting rheumatic carditis, while a value of 65 milliseconds or greater had sensitivity of 81% specificity of 85% in predicting severe valvar lesions in acute rheumatic carditis. At follow-up examination, a clear reduction on the QT dispersion was the main finding, reflecting an electrophysiological improvement. CONCLUSIONS These observations suggest that QT dispersion is increased in association with cardiac involvement in children with acute rheumatic fever.
Medical Science Monitor | 2013
Mehmet Burhan Oflaz; Sevket Balli; Ayse Esin Kibar; İbrahim Ece; Celal Akdeniz; Volkan Tuzcu
Syncope is a frequent complaint in children and adolescents and may be a significant sign of serious pathology. Although patient history, family history, and physical examination are sufficient to reach a diagnosis in most cases of syncope, the cause of syncope still cannot be determined after initial investigation in one‐third to half of all patients. The aim of this study was to evaluate the diagnostic yield of implantable loop recorder (ILR) in children with unexplained syncope.
Pacing and Clinical Electrophysiology | 2014
Cem Karadeniz; Celal Akdeniz; Ozlem Turan; Volkan Tuzcu
OBJECTIVES Curative therapy of idiopathic ventricular tachycardia remains a challenge in interventional electrophysiology. The aim of this study was to demonstrate the utility of an EnSite NavX system in the catheter ablation of idiopathic ventricular tachycardia in children. PATIENTS AND METHODS In all, 17 children with idiopathic ventricular tachycardia underwent electrophysiological studies using the EnSite NavX system guidance. RESULTS The mean patient age was 13 ± 2.4 years (range: 7.8-17.9) and the mean patient weight was 52.3 ± 11.9 kg (range: 32-75). The origin of ventricular tachycardia was in the right ventricular outflow tract in nine patients, in the left ventricle in six, near the bundle of His/right bundle branch in one, and in the left aortic cusp in one. The mean procedure and fluoroscopy times were 169.3 ± 43.2 minutes and 8 ± 10.8 minutes, respectively. No fluoroscopy was used in six patients. The mean radiation exposure was 33.1 ± 56.4 mGy. Acute success was achieved in 14 patients (82%). The focus of ventricular tachycardia was epicardial in two failed procedures. During a mean follow-up of 8.5 ± 7.6 months, ventricular tachycardia recurred in three patients, two of whom underwent a second procedure. Except for one patient who developed transient right bundle branch block, no complications were seen. CONCLUSION Catheter ablation of idiopathic ventricular tachycardia in children can be performed safely and effectively with low fluoroscopy exposure using the EnSite NavX system.