Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Charles Christoph Roehr is active.

Publication


Featured researches published by Charles Christoph Roehr.


Allergy | 2004

Prevalence of adverse reactions to food in Germany – a population study

T. Zuberbier; Günter Edenharter; M. Worm; I. Ehlers; S. Reimann; T. Hantke; Charles Christoph Roehr; K. E. Bergmann; B. Niggemann

Objective:  A population study was performed to identify the prevalence of all kinds of adverse reactions to food.


Clinical & Experimental Allergy | 2004

Food allergy and non‐allergic food hypersensitivity in children and adolescents

Charles Christoph Roehr; Günter Edenharter; S. Reimann; I. Ehlers; M. Worm; Torsten Zuberbier; Bodo Niggemann

Background Previous studies have shown a 10‐fold discrepancy of self‐reported food‐induced symptoms and physician‐diagnosed food hypersensitivity. Little information is available on the prevalence of food hypersensitivity in unselected paediatric populations. No data were available for German children.


Resuscitation | 2015

European Resuscitation Council Guidelines for Resuscitation 2015: Section 7. Resuscitation and support of transition of babies at birth.

Jonathan Wyllie; Jos Bruinenberg; Charles Christoph Roehr; Mario Rüdiger; Daniele Trevisanuto; Berndt Urlesberger

Department of Neonatology, The James Cook University Hospital, Middlesbrough, UK Department of Paediatrics, Sint Elisabeth Hospital, Tilburg, The Netherlands Department of Women and Children’s’ Health, Padua University, Azienda Ospediliera di Padova, Padua, Italy Department of Neonatology, Charite Universitatsmedizin, Berlin, Berlin, Germany Newborn Services, John Radcliffe Hospital, Oxford University Hospitals, Oxford, UK Department of Neonatology, Medizinische Fakultat Carl Gustav Carus, TU Dresden, Germany Division of Neonatology, Medical University Graz, Graz, Austria


Paediatric Respiratory Reviews | 2011

Current methods of non-invasive ventilatory support for neonates.

Ramadan A. Mahmoud; Charles Christoph Roehr; Gerd Schmalisch

Non-invasive ventilatory support can reduce the adverse effects associated with intubation and mechanical ventilation, such as bronchopulmonary dysplasia, sepsis, and trauma to the upper airways. In the last 4 decades, nasal continuous positive airway pressure (CPAP) has been used to wean preterm infants off mechanical ventilation and, more recently, as a primary mode of respiratory support for preterm infants with respiratory insufficiency. Moreover, new methods of respiratory support have been developed, and the devices used to provide non-invasive ventilation (NIV) have improved technically. Use of NIV is increasing, and a variety of equipment is available in different clinical settings. There is evidence that NIV improves gas exchange and reduces extubation failure after mechanical ventilation in infants. However, more research is needed to identify the most suitable devices for particular conditions; the NIV settings that should be used; and whether to employ synchronized or non-synchronized NIV. Furthermore, the optimal treatment strategy and the best time for initiation of NIV remain to be identified. This article provides an overview of the use of non-invasive ventilation (NIV) in newborn infants, and the clinical applications of NIV.


Neonatology | 2012

High-Flow Nasal Cannulae for Respiratory Support of Preterm Infants: A Review of the Evidence

Brett J. Manley; Simone K. Dold; Peter G Davis; Charles Christoph Roehr

Background: High-flow nasal cannulae (HFNC) are gaining in popularity as a form of non-invasive respiratory support for preterm infants in neonatal intensive care units around the world. They are proposed as an alternative to nasal continuous positive airway pressure (NCPAP) in a variety of clinical situations, including post-extubation support, primary therapy from birth and ‘weaning’ from NCPAP. Objectives: To present and discuss the available evidence for the use of HFNC in the preterm population. Methods: An internet-based literature search for relevant, original research articles (both randomised studies and not) on the use of HFNC in preterm infants was undertaken. Results: A total of 19 studies were included in the review. Distending pressure generated by HFNC in preterm infants increases with increasing flow rate and decreasing infant size and varies according to the amount of leak around the prongs. HFNC may be as effective as NCPAP at improving respiratory parameters such as tidal volume and work of breathing in preterm infants, but probably only at flow rates >2 litres/min. The efficacy and safety of HFNC in preterm infants remain to be determined. Conclusions: There is growing evidence of the feasibility of HFNC as an alternative to other forms of non-invasive ventilation in preterm infants. However, there remains uncertainty about the efficacy and safety of HFNC in this population. Until the results of larger randomised trials are known, widespread use of HFNC to treat preterm infants cannot be recommended.


Resuscitation | 2010

Manual ventilation devices in neonatal resuscitation: Tidal volume and positive pressure-provision

Charles Christoph Roehr; Marcus Kelm; Hendrik Fischer; Christoph Bührer; Gerd Schmalisch; Hans Proquitté

BACKGROUND Excessive peak inspiratory pressures (PIP) and high tidal volumes (Vt) during manual ventilation can be detrimental to the neonatal lung. We compared the influence of different manual ventilation devices and individual professional experience on the extent of applied Vt and PIP in simulated neonatal resuscitation. MATERIAL AND METHODS One hundred and twenty medical professionals were studied. An intubated mannequin (equivalent to 1.0 kg neonate) was ventilated using two different devices: a self-inflating bag and a T-piece resuscitator. Target value was a PIP of 20 cm H(2)O. Applied PIP and the resulting Vt were recorded continuously using a respiratory function monitor (CO(2)SMO(+), Novametrix, USA). RESULTS Vt and PIP provision was significantly higher in SI-bags, compared to T-piece devices: median (interquartile range) PIP 25.6 (18.2) cm H(2)O vs 19.7 (3.2) cm H(2)O (p<0.0005), and Vt 5.1(3.2) ml vs Vt 3.6 (0.8) ml (p<0.0005) respectively. The intersubject variability of Vt and PIP provision was distinctly higher in SI-bags, compared to T-piece devices. Professional experience had no significant impact on the level and the variability of Vt or PIP provided. CONCLUSION Use of T-piece devices guarantees reliable and constant Vt and PIP provision, irrespective of individual, operator dependent variables. Methods to measure and to avoid excessive tidal volumes in neonatal resuscitation need to be developed.


Acta Dermato-venereologica | 2006

Frequency of atopic dermatitis and relevance of food allergy in adults in Germany.

Margitta Worm; Karin Forschner; Hae-Hyuk Lee; Charles Christoph Roehr; Günter Edenharter; Bodo Niggemann; Torsten Zuberbier

Many factors may aggravate atopic dermatitis. The aim of this study was to determine the frequency of atopic dermatitis in an unselected population sample and to evaluate the role of food allergy. Patients with atopic dermatitis were recruited from the population in Berlin, Germany, using a postal questionnaire. Skin prick tests for allergens were performed, followed by food challenges. A total of 1739 questionnaires was returned. In all, 23.5% of patients stated that they had atopic dermatitis, and 146 persons (8.4%) fulfilled our atopic dermatitis criteria after a detailed telephone interview. Of these, 111 were examined, and 28 (1.6%) were identified as currently suffering from atopic dermatitis. Twenty-seven patients were further evaluated: 9/27 were found to be skin prick test negative, 19/27 were skin prick test positive either to pollen and/or food allergens. Nine of 27 were challenged with the suspected food allergen: 1/9 showed a worsening of the eczema, 3/9 had oral symptoms, and 5/9 were negative. In conclusion, only 20% of adults with a positive history of atopic dermatitis show active eczema lesions at a given time point. The data indicate that most individuals with atopic dermatitis were sensitized against pollen allergens and according to that, pollen-associated food allergens. A non-selected AD patient cohort does not frequently suffer from clinically relevant pollen-associated food allergy.


Klinische Padiatrie | 2009

Reliability of two common PEEP-generating devices used in neonatal resuscitation.

Marcus Kelm; H. Proquitté; Gerd Schmalisch; Charles Christoph Roehr

BACKGROUND Approximately 15% of neonates require respiratory support at birth, the demand of which increases with decreasing gestational age. Positive end-expiratory pressure (PEEP) stabilizes the airways and improves both pulmonary functional residual capacity and compliance. Self-inflating bags, which can be used with and without a PEEP-valve, are most commonly used for neonatal resuscitation, pressure limited T-piece resuscitators are becoming increasingly popular. The aim of the study was to investigate the reliability of PEEP provision of both systems. MATERIAL AND METHODS An intubated, leak free mannequin (equivalent to 1 kg neonate, pulmonary compliance 0.2 ml*cmH (2)O (-1)) was used for testing both devices. Eleven PEEP-valves attached to a 240 ml self-inflating bag and 5 T-piece resuscitators were investigated. Provision of a PEEP of 5 cmH (2)O (gas flow of 8l/min) at manual ventilation at breaths 40/min was investigated. Data were recorded using a standard pneumotachograph. RESULTS Only 1/11 PEEP-valves provided a PEEP of 5 cmH (2)O (mean (SD) 2.95 (1.82) cmH (2)O, CV 0.62%), in 5/11 (45%) PEEP was <3 cmH (2)O, in 2 of the PEEP-valves produced a PEEP below 0.3 cmH (2)O. All T-piece resuscitators provided a PEEP >5 cmH (2)O (mean 5.59 (0.32) cmH (2)O, CV 0.06%). Significant differences in individual performance per device (p<0.05) and between systems (p=0.007) were found. CONCLUSION Self-inflating bags did not reliably provide the desired PEEP of 5 cmH (2)O, whereas T-piece resuscitators did reliably provide the set PEEP-level, with less variability. When using self-inflating bags with PEEP-valves, neonatologists should check the equipment regarding the reliability of PEEP provision.


European Journal of Medical Research | 2010

DELIVERY ROOM MANAGEMENT OF VERY LOW BIRTH WEIGHT INFANTS IN GERMANY, AUSTRIA AND SWITZERLAND ― A COMPARISON OF PROTOCOLS

Charles Christoph Roehr; S Gröbe; M Rüdiger; H Hummler; M Nelle; Hans Proquitté; Hannes Hammer; Gerd Schmalisch

BackgroundSurveys from the USA, Australia and Spain have shown significant inter-institutional variation in delivery room (DR) management of very low birth weight infants (VLBWI, < 1500 g) at birth, despite regularly updated international guidelines.ObjectiveTo investigate protocols for DR management of VLBWI in Germany, Austria and Switzerland and to compare these with the 2005 ILCOR guidelines.MethodsDR management protocols were surveyed in a prospective, questionnaire-based survey in 2008. Results were compared between countries and between academic and non-academic units. Protocols were compared to the 2005 ILCOR guidelines.ResultsIn total, 190/249 units (76%) replied. Protocols for DR management existed in 94% of units. Statistically significant differences between countries were found regarding provision of 24 hr in house neonatal service; presence of a designated resuscitation area; devices for respiratory support; use of pressure-controlled manual ventilation devices; volume control by respirator; and dosage of Surfactant. There were no statistically significant differences regarding application and monitoring of supplementary oxygen, or targeted saturation levels, or for the use of sustained inflations. Comparison of academic and non-academic hospitals showed no significant differences, apart from the targeted saturation levels (SpO2) at 10 min. of life. Comparison with ILCOR guidelines showed good adherence to the 2005 recommendations.SummaryDelivery room management in German, Austrian and Swiss neonatal units was commonly based on written protocols. Only minor differences were found regarding the DR setup, devices used and the targeted ranges for SpO2 and FiO2. DR management was in good accordance with 2005 ILCOR guidelines, some units already incorporated evidence beyond the ILCOR statement into their routine practice.


Paediatric Respiratory Reviews | 2015

Cardiopulmonary changes with aeration of the newborn lung

Stuart B. Hooper; Graeme R. Polglase; Charles Christoph Roehr

The newborns transition from fetal to neonatal life includes aeration of the lungs, establishment of pulmonary gas exchange and changing the fetal circulation into the adult phenotype. This review summarizes the latest research findings, which show that lung aeration, airway liquid clearance and cardiovascular changes are directly interconnected at birth. The mechanisms of airway liquid clearance at birth are reviewed and the particular importance of the transpulmonary pressure gradient during lung aeration is discussed. Further, we summarize research findings which prove that lung aeration triggers the increase in pulmonary blood flow (PBF) at birth, and how the increase in PBF secures the preload for left ventricular output. Consequently, we review animal experiments which suggest that delaying umbilical cord clamping until breathing commences facilitates hemodynamic stability during transition. These data are reviewed with respect to the clinical applicability: As lung aeration is the key to successful transition to newborn life, providing adequate respiratory support at birth must be the primary objective of neonatal staff attending to the newborn infant. Clinical studies are needed to demonstrate whether the obvious benefits of delaying cord clamping until breathing commences hold true in human babies.

Collaboration


Dive into the Charles Christoph Roehr's collaboration.

Researchain Logo
Decentralizing Knowledge