Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Charles H. Bloodworth is active.

Publication


Featured researches published by Charles H. Bloodworth.


Annals of Biomedical Engineering | 2017

Mitral Valve Chordae Tendineae: Topological and Geometrical Characterization

Amir H. Khalighi; Andrew Drach; Charles H. Bloodworth; Eric L. Pierce; Ajit P. Yoganathan; Robert C. Gorman; Joseph H. Gorman; Michael S. Sacks

Mitral valve (MV) closure depends upon the proper function of each component of the valve apparatus, which includes the annulus, leaflets, and chordae tendineae (CT). Geometry plays a major role in MV mechanics and thus highly impacts the accuracy of computational models simulating MV function and repair. While the physiological geometry of the leaflets and annulus have been previously investigated, little effort has been made to quantitatively and objectively describe CT geometry. The CT constitute a fibrous tendon-like structure projecting from the papillary muscles (PMs) to the leaflets, thereby evenly distributing the loads placed on the MV during closure. Because CT play a major role in determining the shape and stress state of the MV as a whole, their geometry must be well characterized. In the present work, a novel and comprehensive investigation of MV CT geometry was performed to more fully quantify CT anatomy. In vitro micro-tomography 3D images of ovine MVs were acquired, segmented, then analyzed using a curve-skeleton transform. The resulting data was used to construct B-spline geometric representations of the CT structures, enriched with a continuous field of cross-sectional area (CSA) data. Next, Reeb graph models were developed to analyze overall topological patterns, along with dimensional attributes such as segment lengths, 3D orientations, and CSA. Reeb graph results revealed that the topology of ovine MV CT followed a full binary tree structure. Moreover, individual chords are mostly planar geometries that together form a 3D load-bearing support for the MV leaflets. We further demonstrated that, unlike flow-based branching patterns, while individual CT branches became thinner as they propagated further away from the PM heads towards the leaflets, the total CSA almost doubled. Overall, our findings indicate a certain level of regularity in structure, and suggest that population-based MV CT geometric models can be generated to improve current MV repair procedures.


international conference on functional imaging and modeling of heart | 2015

A Comprehensive Framework for the Characterization of the Complete Mitral Valve Geometry for the Development of a Population-Averaged Model

Amir H. Khalighi; Andrew Drach; Fleur M. ter Huurne; Chung-Hao Lee; Charles H. Bloodworth; Eric L. Pierce; Morten O. Jensen; Ajit P. Yoganathan; Michael S. Sacks

Simulations of the biomechanical behavior of the Mitral Valve (MV) based on simplified geometric models are difficult to interpret due to significant intra-patient variations and pathologies in the MV geometry. Thus, it is critical to use a systematic approach to characterization and population-averaging of the patient-specific models. We introduce a multi-scale modeling framework for characterizing the entire MV apparatus geometry via a relatively small set of parameters. The leaflets and annulus are analyzed using a superquadric surface model superimposed with fine-scale filtered level-set field. Filtering of fine-scale features is performed in a spectral space to allow control of resolution, resampling and robust averaging. Chordae tendineae structure is modeled using a medial axis representation with superimposed filtered pointwise cross-sectional area field. The chordae topology is characterized using orientation and spatial distribution functions. The methodology is illustrated with the analysis of an ovine MV microtomography imaging data.


Journal of Medical Devices-transactions of The Asme | 2015

Population-Averaged Geometric Model of Mitral Valve From Patient-Specific Imaging Data

Andrew Drach; Amir H. Khalighi; Fleur M. ter Huurne; Chung-Hao Lee; Charles H. Bloodworth; Eric L. Pierce; Morten O. Jensen; Ajit P. Yoganathan; Michael S. Sacks

The mitral valve (MV) is one of the atrioventricular heart valves and regulates the blood flow between the left atrium and ventricle during the cardiac cycle. Its anatomical structure is comprised of anterior and posterior leaflets, chordae tendineae, and papillary muscles. The main function of the MV is to prevent blood flow regurgitation back into the left atrium during systole. Abnormalities in geometry of MV can lead to mitral insufficiency disorder, which requires either valve replacement or surgical repair to restore proper MV coaptation. Annually, over 40,000 patients in the U.S. alone are treated for MV disorders [1]. In the past two decades, the emphasis in MV treatment has been shifting from replacement toward repair due to lower morbidity and mortality of the latter approach [2]. However, the natural anatomical variability of human MV geometry precludes the use of single or simplified geometries for the simulation of surgical repair. One of the ways to address this issue is by using patient-specific diagnosis and modeling [3], or population-averaged geometric models of MV. The existing approaches for characterization and reconstruction of the cardiovascular organ-level geometry include fitting of predefined sets of nonuniform rational B-splines (NURBS) to the imaging data [4], and using spheroidal harmonics representations [5]. Even though it is possible to construct average geometric models this way, the analysis of anatomical shape variations becomes difficult in this setting because of the confounding of dimensional and shape descriptors. At the same time, none of the existing methods allow integration of the high-fidelity in vitro data with lower-resolution in vivo imaging in a consistent manner. In this work, we formulate the framework for building the population-averaged geometric model of MV, which lends to straightforward analysis of dimensional and anatomical variations. In the sections to follow, we discuss the procedure and advantages of this method for the development of robust medical devices and treatment procedures.


The Journal of Thoracic and Cardiovascular Surgery | 2018

Mitral annuloplasty ring suture forces: Impact of surgeon, ring, and use conditions

Eric L. Pierce; Charles H. Bloodworth; Andrew W. Siefert; Thomas F. Easley; Tetsushi Takayama; Tomonori Kawamura; Robert C. Gorman; Joseph H. Gorman; Ajit P. Yoganathan

Objective The study objective was to quantify the effect of ring type, ring‐annulus sizing, suture position, and surgeon on the forces required to tie down and constrain a mitral annuloplasty ring to a beating heart. Methods Physio (Edwards Lifesciences, Irvine, Calif) or Profile 3D (Medtronic, Dublin, Ireland) annuloplasty rings were instrumented with suture force transducers and implanted in ovine subjects (N = 23). Tie‐down forces and cyclic contractile forces were recorded and analyzed at 10 suture positions and at 3 levels of increasing peak left ventricular pressure. Results Across all conditions, tie‐down force was 2.7 ± 1.4 N and cyclic contractile force was 2.0 ± 1.2 N. Tie‐down force was not meaningfully affected by any factor except surgeon. Significant differences in overall and individual tie‐down forces were observed between the 2 primary implanting surgeons. No other factors were observed to significantly affect tie‐down force. Contractile suture forces were significantly reduced by ring‐annulus true sizing. This was driven almost exclusively by Physio cases and by reduction along the anterior aspect, where dehiscence is less common clinically. Contractile suture forces did not differ significantly between ring types. However, when undersizing, Profile 3D forces were significantly more uniform around the annular circumference. A sutures tie‐down force did not correlate to its eventual contractile force. Conclusions Mitral annuloplasty suture loading is influenced by ring type, ring‐annulus sizing, suture position, and surgeon, suggesting that reports of dehiscence may not be merely a series of isolated errors. When compared with forces known to cause suture dehiscence, these in vivo suture loading data aid in establishing potential targets for reducing the occurrence of ring dehiscence.


medical image computing and computer assisted intervention | 2014

Multi-modal Validation Framework of Mitral Valve Geometry and Functional Computational Models

Sasa Grbic; Thomas F. Easley; Tommaso Mansi; Charles H. Bloodworth; Eric L. Pierce; Ingmar Voigt; Dominik Neumann; Julian Krebs; David D. Yuh; Morten O. Jensen; Dorin Comaniciu; Ajit P. Yoganathan

Computational models of the mitral valve (MV) exhibit significant potential for patient-specific surgical planning. Recently, these models have been advanced by incorporating MV tissue structure, non-linear material properties, and more realistic chordae tendineae architecture. Despite advances, only limited ground-truth data exists to validate their ability to accurately simulate MV closure and function. The validation of the underlying models will enhance modeling accuracy and confidence in the simulated results. A necessity towards this aim is to develop an integrated pipeline based on a comprehensive in-vitro flow loop setup including echocardiography techniques (Echo) and micro-computed tomography. Building on [1] we improved the acquisition protocol of the proposed experimental setup for in-vitro Echo imaging, which enables the extraction of more reproducible and accurate geometrical models, using state-of-the art image processing and geometric modeling techniques. Based on the geometrical parameters from the Echo MV models captured during diastole, a bio-mechanical model is derived to estimate MV closure geometry. We illustrate the framework on two data sets and show the improvements obtained from the novel Echo acquisition protocol and improved bio-mechanical model.


Annals of Biomedical Engineering | 2017

Fluid-Structure Interaction Analysis of Ruptured Mitral Chordae Tendineae

Milan Toma; Charles H. Bloodworth; Eric L. Pierce; Daniel R. Einstein; Richard P. Cochran; Ajit P. Yoganathan; Karyn S. Kunzelman

The chordal structure is a part of mitral valve geometry that has been commonly neglected or simplified in computational modeling due to its complexity. However, these simplifications cannot be used when investigating the roles of individual chordae tendineae in mitral valve closure. For the first time, advancements in imaging, computational techniques, and hardware technology make it possible to create models of the mitral valve without simplifications to its complex geometry, and to quickly run validated computer simulations that more realistically capture its function. Such simulations can then be used for a detailed analysis of chordae-related diseases. In this work, a comprehensive model of a subject-specific mitral valve with detailed chordal structure is used to analyze the distinct role played by individual chordae in closure of the mitral valve leaflets. Mitral closure was simulated for 51 possible chordal rupture points. Resultant regurgitant orifice area and strain change in the chordae at the papillary muscle tips were then calculated to examine the role of each ruptured chorda in the mitral valve closure. For certain subclassifications of chordae, regurgitant orifice area was found to trend positively with ruptured chordal diameter, and strain changes correlated negatively with regurgitant orifice area. Further advancements in clinical imaging modalities, coupled with the next generation of computational techniques will enable more physiologically realistic simulations.


Medical Image Analysis | 2017

Personalized mitral valve closure computation and uncertainty analysis from 3D echocardiography

Sasa Grbic; Thomas F. Easley; Tommaso Mansi; Charles H. Bloodworth; Eric L. Pierce; Ingmar Voigt; Dominik Neumann; Julian Krebs; David D. Yuh; Morten O. Jensen; Dorin Comaniciu; Ajit P. Yoganathan

&NA; Intervention planning is essential for successful Mitral Valve (MV) repair procedures. Finite‐element models (FEM) of the MV could be used to achieve this goal, but the translation to the clinical domain is challenging. Many input parameters for the FEM models, such as tissue properties, are not known. In addition, only simplified MV geometry models can be extracted from non‐invasive modalities such as echocardiography imaging, lacking major anatomical details such as the complex chordae topology. A traditional approach for FEM computation is to use a simplified model (also known as parachute model) of the chordae topology, which connects the papillary muscle tips to the free‐edges and select basal points. Building on the existing parachute model a new and comprehensive MV model was developed that utilizes a novel chordae representation capable of approximating regional connectivity. In addition, a fully automated personalization approach was developed for the chordae rest length, removing the need for tedious manual parameter selection. Based on the MV model extracted during mid‐diastole (open MV) the MV geometric configuration at peak systole (closed MV) was computed according to the FEM model. In this work the focus was placed on validating MV closure computation. The method is evaluated on ten in vitro ovine cases, where in addition to echocardiography imaging, high‐resolution &mgr;CT imaging is available for accurate validation. HighlightsA novel MV model was introduced that utilizes two novel chordae representations capable of approximating regional connectivity, showing a significant improvement in accuracy in closure computation when compared to the simplified parachute model.The hierarchical personalization framework of the rest length parameters removes the need for tedious manual parameter selection.The proposed method was evaluated on ten in vitro ovine cases, where in addition to echocardiography imaging, high‐resolution micro‐CT imaging is available for accurate validation. Graphical abstract Figure. No caption available.


Journal of Biomechanics | 2018

Effects of annular contraction on anterior leaflet strain using an in vitro simulator with a dynamically contracting mitral annulus

Thomas F. Easley; Charles H. Bloodworth; Vinay Bhal; Ajit P. Yoganathan

Using in vitro models, the mechanics as well as surgical techniques for mitral valves (MV) and MV devices can be studied in a more controlled environment with minimal monetary investment and risk. However, these current models rely on certain simplifications, one being that the MV has a static, rigid annulus. In order to study more complex issues of imaging diagnostics and implanted device function, it would be more advantageous to verify their use for a dynamic environment in a dynamic simulator. This study provides the novel design and development of a dynamically contracting annulus (DCA) within an in vitro simulator, and its subsequent use to study MV biomechanics. Experiments were performed to study the ability of the DCA to reproduce the MV leaflet mechanics in vitro, as seen in vivo, as well as investigate how rigid annuloplasties affect MV leaflet mechanics. Experiments used healthy, excised MVs and normal hemodynamics; contractile waveforms were derived from human in vivo data. Stereophotogrammetry and echocardiography were used to measure anterior leaflet strain and the change in MV geometry. In pursuit of the first in vitro MV simulator that more completely represents the dynamic motion of the full valvular apparatus, this study demonstrated the successful operation of a dynamically contracting mitral annulus. It was seen that the diseased contractile state increased anterior leaflet strain compared to the healthy contractile state. In addition, it was also shown in vitro that simulated rigid annuloplasty increased mitral anterior leaflet strain compared to a healthy contraction.


Journal of Biomechanics | 2018

Mitral annuloplasty ring flexibility preferentially reduces posterior suture forces

Eric L. Pierce; Charles H. Bloodworth; Akito Imai; Keitaro Okamoto; Yoshiaki Saito; Robert C. Gorman; Joseph H. Gorman; Ajit P. Yoganathan

Annuloplasty ring repair is a common procedure for the correction of mitral valve regurgitation. Commercially available rings vary in dimensions and material properties. Annuloplasty ring suture dehiscence from the native annulus is a catastrophic yet poorly understood phenomenon that has been reported across ring types. Recognizing that sutures typically dehisce from the structurally weaker posterior annulus, our group is conducting a multi-part study in search of ring design parameters that influence forces acting on posterior annular sutures in the beating heart. Herein, we report the effect of ring rigidity on suture forces. Measurements utilized custom force sensors, attached to annuloplasty rings and implanted in normal ovine subjects via standard surgical procedure. Tested rings included the semi-rigid Physio (Edwards Lifesciences) and rigid and flexible prototypes of matching geometry. While no significant differences due to ring stiffness existed for sutures in the anterior region, posterior forces were significantly reduced with use of the flexible ring (rigid: 1.95 ± 0.96 N, semi-rigid: 1.76 ± 1.19 N, flexible: 1.04 ± 0.63 N; p < 0.001). The ratio of anterior to posterior FC scaled positively with increasing flexibility (p < 0.001), and posterior forces took more time to reach their peak load when a flexible ring was used (p < 0.001). This suggests a more rigid ring enables more rapid/complete force equilibration around the suture network, transferring higher anterior forces to the weaker posterior tissue. For mitral annuloplasties requiring ring rigidity, we propose a ring design concept to potentially disrupt this force transfer and improve suture retention.


Catheterization and Cardiovascular Interventions | 2018

Impact of simulated MitraClip on forward flow obstruction in the setting of mitral leaflet tethering: An in vitro investigation

Charles H. Bloodworth; Eric L. Pierce; Keshav Kohli; Nancy J. Deaton; Kaitlin J. Jones; Radhika Duvvuri; Norihiko Kamioka; Vasilis Babaliaros; Ajit P. Yoganathan

We aimed to evaluate diastolic leaflet tethering as a factor that may cause mitral stenosis (MS) after simulated MitraClip implantation, using an in vitro left heart simulator.

Collaboration


Dive into the Charles H. Bloodworth's collaboration.

Top Co-Authors

Avatar

Ajit P. Yoganathan

Georgia Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Eric L. Pierce

Georgia Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Thomas F. Easley

Georgia Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Amir H. Khalighi

University of Texas at Austin

View shared research outputs
Top Co-Authors

Avatar

Andrew Drach

University of Texas at Austin

View shared research outputs
Top Co-Authors

Avatar

Joseph H. Gorman

University of Pennsylvania

View shared research outputs
Top Co-Authors

Avatar

Michael S. Sacks

University of Texas at Austin

View shared research outputs
Top Co-Authors

Avatar

Milan Toma

Georgia Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Robert C. Gorman

University of Pennsylvania

View shared research outputs
Researchain Logo
Decentralizing Knowledge