Chris Ruth
Hologic
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Chris Ruth.
Medical Imaging 2005: Physics of Medical Imaging | 2005
Baorui Ren; Chris Ruth; Jay A. Stein; Andrew P. Smith; Ian Shaw; Zhenxue Jing
We have developed a breast tomosynthesis system utilizing a selenium-based direct conversion flat panel detector. This prototype system is a modification of Selenia, Hologic’s full field digital mammography system, using an add-on breast holding device to allow 3D tomosynthetic imaging. During a tomosynthesis scan, the breast is held stationary while the x-ray source and detector mounted on a c-arm rotate continuously around the breast over an angular range up to 30 degrees. The x-ray tube is pulsed to acquire 11 projections at desired c-arm angles. Images are reconstructed in planes parallel to the breastplate using a filtered backprojection algorithm. Processing time is typically 1 minute for a 50 mm thick breast at 0.1 mm in-plane pixel size, 1 mm slice-to-slice separation. Clinical studies are in progress. Performance evaluations were carried out at the system and the subsystem levels including spatial resolution, signal-to-noise ratio, spectra optimization, imaging technique, and phantom and patient studies. Experimental results show that we have successfully built a tomosynthesis system with images showing less structure noise and revealing 3D information compared with the conventional mammogram. We introduce, for the first time, the definition of “Depth of Field” for tomosynthesis based on a spatial resolution study. This parameter is used together with Modulation Transfer Function (MTF) to evaluate 3D resolution of a tomosynthesis system as a function of system design, imaging technique, and reconstruction algorithm. Findings from the on-going clinical studies will help the design of the next generation tomosynthesis system offering improved performance.
Proceedings of SPIE | 2010
Baorui Ren; Chris Ruth; Tao Wu; Yiheng Zhang; Andrew P. Smith; Loren Niklason; Cornell Williams; Elena Ingal; Brad Polischuk; Zhenxue Jing
A new generation of digital breast tomosynthesis system has been designed and is commercially available outside the US. The system has both a 2D mode and a 3D mode to do either conventional mammography or tomosynthesis. Uniquely, it also has a fusion mode that allows both 3D and 2D images to be acquired under the same breast compression, which results in co-registered images from the two modalities. The aim of this paper is to present a technical description on the design and performance of the new system, including system details such as filter options, doses, AEC operation, 2D and 3D images co-registration and display, and the selenium detector performance. We have carried out both physical and clinical studies to evaluate the system. In this paper the focus will be mainly on technical performance results.
international conference on digital mammography | 2006
Andrew P. Smith; Loren Niklason; Baorui Ren; Tao Wu; Chris Ruth; Zhenxue Jing
Visibility of lesions in mammography are significantly reduced by the presence of anatomical, or structure, noise. Breast tomosynthesis offers the possibility of reducing this noise. We have compared the detection of low contrast and microcalcification objects with tomosynthesis imaging as a function of dose to full field digital mammography (FFDM) performed at a standard screening dose. The measurements were performed with a variety of phantoms and complex backgrounds. The complex backgrounds greatly reduced object visibility using FFDM; much less so for the tomosynthesis images. In summary, visibility of low contrast objects using tomosynthesis was superior to visibility of these objects in FFDM, even when the tomosynthesis imaging was performed at 1/4 or less of a FFDM dose. Tomosynthesis also showed superior visibility to FFDM for 160-180 micron microcalcifications at 1/2 the FFDM dose.
international conference on digital mammography | 2006
Baorui Ren; Tao Wu; Andrew P. Smith; Chris Ruth; Loren Niklason; Zhenxue Jing; Jay A. Stein
In general, the use of more projections results in fewer tomosynthesis reconstruction artifacts. However, under a fixed dose, an excess number of projections will make the detector noise more pronounced in each of the x-ray shots and thus degrade image quality. Even in the absence of detector noise the advantages of higher projection numbers eventually have diminishing returns, making more projections unnecessary. In this study, we explore the dependence of tomosynthesis imaging performance on the number of projections, while keeping other factors fixed. We take the contrast-to-noise ratio as the figure of merit to search for the range of optimal projection number. The study is carried out through both simulations and experiments, with phantoms consisting of micro-calcification and mass objects, and a cadaver breast. The goal of this paper is to describe our methodology in general, and use a prototype tomosynthesis system as an example. The knowledge learned will help the design of future generation clinical tomosynthesis systems.
Proceedings of SPIE | 2009
Baorui Ren; Chris Ruth; Yiheng Zhang; Andrew P. Smith; Cornell Williams; Brad Polischuk; Zhenxue Jing
The performance optimization of tomosynthesis is very challenging as it involves multiple system parameters to be optimized towards multiple figures of merit (FOM). Common approach is to take a selected few FOMs and optimize them under more confined conditions. While this kind of study helps us to gain more insights, extra precautions are needed when one tries to generalize the conclusions. Several reported works have shown that increasing the scan angle improves the contrast to noise ratio (CNR), which made the authors conclude that from the CNR perspective, large scan angle has advantages over small angle in tomosynthesis. In this study, we investigated the dependence of CNR on the scan angle while other system parameters were fixed. We found that improvement of CNR with large scan angle in those published studies was actually due to reconstruction algorithm and associated filtering effect but not due to the scan angle itself. To reveal this property, we selected six filters to cover a board range of possible shapes, and showed CNR variations with different filters. Besides, we also studied the ML-EM and SART iterative reconstruction algorithms, and obtained their equivalent Fourier filters numerically. The change of the equivalent filter shapes of iterative methods at different scan angle explained the observed CNR dependence on the scan angles. We conclude that larger scan angle does not have any intrinsic CNR advantage over small one in tomosynthesis. The observed CNR gain at large angle is an effect from the reconstruction filters. Therefore CNR based optimization study need to be carried out without the potential bias from filters.
international conference on breast imaging | 2012
Sara Gavenonis; Kristen C. Lau; Roshan Karunamuni; Yiheng Zhang; Baorui Ren; Chris Ruth; Andrew D. A. Maidment
An assessment is ongoing of the ability of dual energy contrast-enhanced digital breast tomosynthesis (CE-DBT) to depict the morphologic and vascular characteristics of breast cancer in comparison with breast MRI and digital mammography (DM). Eight patients with newly diagnosed breast cancer were imaged with an automated dual-energy CE-DBT system. High energy/low energy image pairs of the index breast were obtained at 1 pre- and 3 post-contrast timepoints. Post-contrast images were obtained after intravenous administration of Visipaque (1 mL/kg). Anatomic images were reconstructed using filtered backprojection, and contrast-enhanced images were generated using simple backprojection followed by temporal or dual-energy subtraction. Dual-energy CE-DBT was able to demonstrate the index malignant lesion in 7 of 8 patients (9 of 10 lesions). Morphologic characteristics including margin detail and associated microcalcifications were qualitatively concordant with DM. Vascular characteristics were identifiable qualitatively on post-processed images in some cases, and judged to be qualitative concordant with breast MRI.
Proceedings of SPIE | 2013
Baorui Ren; Chris Ruth; Yiheng Zhang; Andrew P. Smith; Don Kennedy; Bernadette O'Keefe; Ian Shaw; Cornell Williams; Zhen Ye; Elena Ingal; Brad Polischuk; Zhenxue Jing
We have developed dual energy (DE) iodine contrast imaging functions with a commercial mammography and tomosynthesis system. Our system uses a tungsten target x-ray tube and selenium direct conversion detector. Conventional low energy (LE) images were acquired with existing Rh, Ag and Al filters at the screening doses while the high energy images (HE) were acquired with new Cu filters at half of the screening doses. In DE 2D mode, a pair of LE and HE images was taken with one second delay time between and with anti-scatter grid. In DE 3D mode, 22 views of alternating LE and HE were taken over 15 degrees angle in seven seconds without grid while tube was scanned continuously. We used log-subtraction algorithm to obtain clean DE images with the subtraction factor K derived empirically. In 3D mode, the subtraction was applied to each pair of LE and HE slices after reconstruction. The x-ray technique optimization was done with simulation and phantom study. We performed both phantom and patient studies to demonstrate the advantage of iodine contrast imaging. Among several new things in our work, a selenium detector optimized for DE imaging was tested and a large dose advantage was demonstrated; 2D and 3D DE images of a breast under same compression were acquired with a unique DE combo mode of the system, allowing direct image quality comparison between 2D and 3D modes. Our study showed that new DE system achieved good image quality. DE imaging is be a promising modality to detect breast cancer.
Proceedings of SPIE | 2011
Baorui Ren; Yiheng Zhang; Chris Ruth; Andrew P. Smith; Loren Niklason; Zhong Tao; Zhenxue Jing
Patient motion is frequently a problem in mammography, especially when the x-ray exposure is long, resulting in image quality degradation. At present, patient motion can only be identified by inspecting the image subjectively after image acquisition. As digital breast tomosynthesis (DBT) takes longer time to complete the data acquisition than conventional mammography, there is more chance for patient motion to happen in DBT. Therefore it is important to understand the potential motion problem in DBT and incorporate a design to minimize it. In this paper we present an automatic method to detect patient motions in DBT. The method is developed based on an understanding that, features of breast should move along predictable trajectory in a time-series of projection measurements; deviations from it are linked to patient motion. Motion distance is estimated by analyzing skin lines and large calcifications (if exist) in all projection images and then a motion score is derived for a DBT scan. Effectiveness and robustness of this method will be demonstrated with clinical data, together with discussions on different motion patterns observed clinically. The impacts of this work could be far-reaching. It allows real-time detection and objective evaluation of patient motions, applicable to all breasts. Patient with severe motion can be re-scanned immediately before leaving the room. Data with moderate motions can go through additional targeted image processing to minimize motion artifacts. It also enables a powerful tool to evaluate and optimize different DBT designs to minimize the patient motion problem. Besides, this method can be extended to other imaging modalities, e.g. breast CT, to study patient motions.
Medical Imaging 2008: Physics of Medical Imaging | 2008
Baorui Ren; Andrew P. Smith; Chris Ruth; Zhenxue Jing
We studied the use of the mammography contrast detail phantom (CDMAM) with tomosynthesis to evaluate the performance of our system as well as to explore the application of CDMAM in 3D breast imaging. The system was Hologics 1st generation tomosynthesis machine. CDMAM phantom plus PMMA slabs were imaged at 3 cm, 5 cm, 7 cm, and 9 cm PMMA-equivalent thickness with 11 projections per scan and the scan angle selected from 0, 15 and 28 degrees. CDMAM images were reconstructed using the back projection method, and were scored with the CDCOM automatic analysis program. The threshold thickness of each disk size was obtained with psychometric curve fitting. We first studied errors and variability associated with the results when different numbers of images were used in contrast detail analysis, then studied factors that affected CDMAM results in tomosynthesis, including the x-ray dose, the scan angle, the in-plane reconstruction pixel size, the slice-to-slice step size, the location of the CDMAM inside the PMMA slabs, and the scatter effect. This paper will present results of CDMAM performance of our tomosynthesis system, as well as their dependence on the various factors, and the comparison with 2D mammography. Additionally we will discuss the novel processing and analysis methods developed during this study, and make proposals to modify the CDMAM phantom and the CDCOM analysis program to optimize the method for 3D tomosynthesis.
Medical Imaging 2018: Physics of Medical Imaging | 2018
Biao Chen; Chris Ruth; Zhenxue Jing; Yiheng Zhang
Breast composition density has been identified to be a risk factor of developing breast cancer and an indicator of lesion diagnostic obstruction due to masking effect in x-ray mammography images. Volumetric density measurement evaluates fibro-glandular volume, breast volume, and breast volume density measures that have potential advantages over area density measurement in risk assessment. Compared to traditional x-ray absorption computing based areal and volumetric tissue density assessments, image feature detection based density classification approaches emulate the clinical density evaluation process by radiologists instead of using indirect information (e.g., percentage density values). We have modeled breast density assessment as a machine intelligence task which automatically extract the image features and dynamically improves density classification performance in clinical environment: (1) a bank of deep learning networks are explored to automatically extract the image features that emulate the radiologists’ image review process; (2) the pretrained networks are retrained with clinical 2D digital mammography images (for processing and for presentation DICOM images) using transfer learning; (3) a deep reinforcement network is incorporated through human-machine gaming process. The data preprocessing, trained models / processes have been described, and the classification inference have been evaluated with the predicted breast density category values of the clinical validation 2D digital mammographic images in terms of statistic measures. The experimental results have shown that the method is promising for breast density assessment.