Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Christian Perigaud is active.

Publication


Featured researches published by Christian Perigaud.


Circulation | 2014

Early Structural Valve Deterioration of Mitroflow Aortic Bioprosthesis Mode, Incidence, and Impact on Outcome in a Large Cohort of Patients

Thomas Sénage; Thierry Le Tourneau; Yohann Foucher; Sabine Pattier; Caroline Cueff; Magali Michel; J.M. Serfaty; Antoine Mugniot; Christian Perigaud; Hubert François Carton; Ousama Al Habash; Olivier Baron; Jean Christian Roussel

Background— Structural valve deterioration (SVD) is a major flaw of bioprostheses. Early SVD has been suspected in the last models of Mitroflow bioprosthesis. We sought to assess the incidence, mode, and impact of SVD on outcome in a large series of Mitroflow aortic valve replacement. Methods and Results— Six hundred seventeen consecutive patients (aged 76.1±6.3 years) underwent aortic valve replacement with a Mitroflow prosthesis (models 12A/LX) between 2002 and 2007. By echocardiography, 39 patients developed early SVD (1.66% per patient-year), with stenosis as the main mode (n=36). Mean delay to SVD was only 3.8±1.4 years, and 5-year SVD-free survival was 91.6% (95% confidence interval [CI], 88.7–94.7) for the whole cohort and 79.8% (95% CI, 71.2–89.4) and 94.0% (95% CI, 90.3–97.8) for 19- and 21-mm sizes, respectively. Among the 39 patients with SVD, 13 patients (33%) had an accelerated SVD once the mean gradient exceeded 30 mm Hg. Valve-related death was 46.2% in this SVD subgroup. Five-year overall survival was 69.6% (95% CI, 65.7–73.9). In multivariable analysis, SVD was the strongest correlate of overall mortality (hazard ratio=7.7; 95% CI, 4.4–13.6). Conclusions— Early SVD is frequent in Mitroflow bioprosthesis (models 12A/LX), especially for small sizes (19 and 21 mm), and reduces overall survival. An unpredictable accelerated pattern of SVD constitutes a life-threatening condition. In view of the large number of Mitroflow valves implanted worldwide, one can expect an epidemic of SVD and valve-related deaths, which represents a major public health issue, especially in the elderly. Hence, a close follow-up with yearly echocardiography after Mitroflow implantation is advisable. An urgent reoperation should be discussed in patients with severe SVD even though they are still asymptomatic.Background— Structural valve deterioration (SVD) is a major flaw of bioprostheses. Early SVD has been suspected in the last models of Mitroflow bioprosthesis. We sought to assess the incidence, mode, and impact of SVD on outcome in a large series of Mitroflow aortic valve replacement. Methods and Results— Six hundred seventeen consecutive patients (aged 76.1±6.3 years) underwent aortic valve replacement with a Mitroflow prosthesis (models 12A/LX) between 2002 and 2007. By echocardiography, 39 patients developed early SVD (1.66% per patient-year), with stenosis as the main mode (n=36). Mean delay to SVD was only 3.8±1.4 years, and 5-year SVD-free survival was 91.6% (95% confidence interval [CI], 88.7–94.7) for the whole cohort and 79.8% (95% CI, 71.2–89.4) and 94.0% (95% CI, 90.3–97.8) for 19- and 21-mm sizes, respectively. Among the 39 patients with SVD, 13 patients (33%) had an accelerated SVD once the mean gradient exceeded 30 mm Hg. Valve-related death was 46.2% in this SVD subgroup. Five-year overall survival was 69.6% (95% CI, 65.7–73.9). In multivariable analysis, SVD was the strongest correlate of overall mortality (hazard ratio=7.7; 95% CI, 4.4–13.6). Conclusions— Early SVD is frequent in Mitroflow bioprosthesis (models 12A/LX), especially for small sizes (19 and 21 mm), and reduces overall survival. An unpredictable accelerated pattern of SVD constitutes a life-threatening condition. In view of the large number of Mitroflow valves implanted worldwide, one can expect an epidemic of SVD and valve-related deaths, which represents a major public health issue, especially in the elderly. Hence, a close follow-up with yearly echocardiography after Mitroflow implantation is advisable. An urgent reoperation should be discussed in patients with severe SVD even though they are still asymptomatic. # CLINICAL PERSPECTIVE {#article-title-37}


European Journal of Cardio-Thoracic Surgery | 2009

Prospective preoperative mediastinal lymph node staging by integrated positron emission tomography—computerised tomography in patients with non-small-cell lung cancer §

Christian Perigaud; Boumédiène Bridji; Jean Christian Roussel; Christine Sagan; Antoine Mugniot; Daniel Duveau; Olivier Baron; Philippe Despins

OBJECTIVE Mediastinal lymph node staging determines the treatment strategy for non-small-cell lung cancer. This study aims to evaluate prospectively the accuracy of preoperative integrated 18-fluoro-2-deoxy-D-glucose positron emission tomography-computerised tomography ((18)FDG PET-CT) for mediastinal lymph node staging. METHODS Preoperative integrated (18)FDG PET-CT was used to analyse mediastinal lymph nodes in patients with non-small-cell lung cancer. Nodal stations were identified according to the American Thoracic Society mapping system. Lymph nodes with a standardised uptake value (SUVmax) >3 were considered to be positive. The mediastinal lymph nodes were harvested during lung resection and the results of integrated (18)FDG PET-CT were compared to the mediastinal lymph node histology results. RESULTS A total of 51 patients were enrolled in this study. The mean interval between integrated (18)FDG PET-CT and surgery was 31+/-15.8 days (range: 2-78 days). The mean mediastinal lymph node harvested and station number per patient during surgery were 11.8+/-5.6 (range: 2-27) and 3.8+/-1 (range: 2-6), respectively. The incidence of N2 pathological disease was 19.6%. The integrated (18)FDG PET-CT sensitivity and specificity were 40+/-30% and 85+/-11%, respectively. The positive and negative predictive values were 40+/-30% and 85+/-11%, respectively. False-positive results (six patients) were mainly due to inflammatory lymph nodes. False-negative results (six patients) were mainly due to infra-centimetrical, malignant lymph node invasion. CONCLUSION The sensitivity of integrated (18)FDG PET-CT for mediastinal lymph node staging in patients selected for surgery is low. When positive mediastinal lymph nodes are detected, invasive mediastinal staging must be performed. On the other hand, the specificity is high: patients with negative integrated (18)FDG PET-CT can be operated upon without invasive mediastinal staging.


American Journal of Pathology | 2011

Identification of Novel Markers for the Diagnosis of Malignant Pleural Mesothelioma

Fabien Gueugnon; Sabrina Leclercq; Christophe Blanquart; Christine Sagan; Laurent Cellerin; Martine Padieu; Christian Perigaud; Arnaud Scherpereel; Marc Grégoire

The diagnosis of malignant pleural mesothelioma is difficult, with the most common differential diagnoses being benign pleural diseases and metastatic adenocarcinomas (ADCA). To identify novel markers that would be able to improve diagnostic accuracy, we performed a genome-wide gene expression analysis on tumor cell lines established from pleural effusions (malignant pleural mesothelioma and lung ADCA). This analysis led to the identification of genes encoding novel and pertinent cellular and soluble markers, for which the expression was validated by real-time RT-PCR. Immunohistochemical staining of tumor biopsy specimens with anti-type III collagen antibodies showed positive labeling for mesothelioma cells but not for ADCA cells. Using enzyme-linked immunosorbent assay, we showed that the C-C motif chemokine 2 (CCL2) concentration was significantly higher in pleural effusions from patients with mesothelioma (n = 61) than in subjects with ADCA (n = 25) or with benign pleural effusions (n = 15): median (interquartile range) = 2.99 ng/ml (1.76 to 6.01) vs 0.99 ng/ml (0.51 to 1.83) and 1.47 ng/ml (0.80 to 1.56), respectively, P < 0.0001. Conversely, the galectin-3 concentration was lower in mesothelioma: 11.50 ng/ml (6.73 to 23.53) vs 24.74 ng/ml (20.42 to 70.35) and 17.64 ng/ml (14.81 to 24.68), respectively, P < 0.0001. The areas under the curve for CCL2 were 0.8030 and 0.7716 for the differentiation of mesothelioma from ADCA or benign pleural effusions, respectively. Similarly, the areas under the curve obtained for galectin-3 were 0.7980 and 0.6923, respectively. In conclusion, type III collagen, CCL2, and galectin-3 are promising new diagnostic markers for mesothelioma.


Journal of Heart and Lung Transplantation | 2007

Outcome of Heart Transplants 15 to 20 Years Ago : Graft Survival, Post-transplant Morbidity, and Risk Factors for Mortality

Jean Christian Roussel; Olivier Baron; Christian Perigaud; Philippe Bizouarn; Sabine Pattier; Oussama Al Habash; Antoine Mugniot; Thierry Petit; Jean Luc Michaud; M.F. Heymann; Michèle Treilhaud; Jean Noel Trochu; Jean Pierre Gueffet; Guillaume Lamirault; Daniel Duveau; Philippe Despins

OBJECTIVES The study was conducted to determine the long-term outcome of patients who underwent heart transplantation 15 to 20 years ago, in the cyclosporine era, and identify risk factors for death. METHODS A retrospective analysis was done of 148 patients who had undergone heart transplantation between 1985 and 1991 at a single center. Operative technique and immunosuppressive treatment were comparable in all patients. RESULTS Actuarial survival rates were 75% (n = 111), 58% (n = 86), and 42% (n = 62) at 5, 10, and 15 years, respectively. The mean follow-up period was 12.1 +/- 5.6 years for patients who survived more than 3 months after transplantation (n = 131). The major causes of death were malignancy (35.8%) and cardiac allograft vasculopathy (24.7%). No death related to acute rejection was reported after the first month of transplantation. Graft coronary artery disease was detected on angiography in 66 (50.3%), and 7 (5.3%) had retransplantation. Malignancies developed in 131 patients (48.1%), including skin cancers in 31 (23.6%), solid tumors in 26 (19.8%), and hematologic malignancies in 14 (10.6%). Severe renal function requiring dialysis or renal transplantation developed in 27 patients (20.6%). By multivariable analysis, the only pre-transplant risk factor found to affect long-term survival was a history of cigarette use (p < 0.0004). CONCLUSIONS Long-term survival at 15 years after cardiac transplantation remains excellent in the cyclosporine era. Controlling acute allograft rejection can be achieved but seems to carry a high rate of cancers and renal dysfunction. History of cigarette use affects significantly long-term survival in our study.


The Annals of Thoracic Surgery | 2009

CardioWest (Jarvik) Total Artificial Heart: A Single-Center Experience With 42 Patients

Jean Christian Roussel; Thomas Sénage; Olivier Baron; Christian Perigaud; Oussama Al Habash; Jean Christophe Rigal; Michèle Treilhaud; Jean Noel Trochu; Philippe Despins; Daniel Duveau

BACKGROUND When implanted in patients with biventricular failure, the CardioWest total artificial heart has asserted itself over time as a reliable bridge-to-transplant device that as yet is used by only a few international teams. The aim of this single-center retrospective study is to assess both the comorbidity and survival of patients awaiting heart transplants while receiving circulatory support with a CardioWest total artificial heart. METHODS From 1990 to December 2006, 42 patients received a CardioWest total artificial heart at our center. Mean age at the time of implantation was 45.7 +/- 9.5 years, and 40 patients (95%) were men. Idiopathic or dilated cardiomyopathy was diagnosed in 45.2% (n = 19) of the patients and ischemic cardiomyopathy in 42.8% (n = 18). Average body surface area was 1.9 +/- 0.22 m(2). RESULTS Duration of support was 1 to 292 days (mean, 101 +/- 86 days). Twelve patients died (28.5%) while receiving device support, and 30 patients (71.5%) underwent transplantation. Actuarial survival rates for the transplanted patients were 90% (n = 25), 81% (n = 14), and 76% (n = 10) at 1, 5, and 10 years, respectively. Causes of death during device support included multiorgan failure in 6 (50%), sepsis in 2, acute respiratory distress syndrome in 2, alveolar hemorrhage in 1, and other cause in 1. There were no device malfunctions that led to patient death. Adverse events included stroke in 3 patients (7%) and infections in 35 patients (85%) during support. CONCLUSIONS The CardioWest total artificial heart is an excellent bridge-to-transplant device for patients with biventricular failure. Our study demonstrates excellent safety, reliability, and efficiency. Exceptional outcome after transplantation underlines its capacity to aid in end-organ recovery.


Stem Cell Research & Therapy | 2010

Cell distribution after intracoronary bone marrow stem cell delivery in damaged and undamaged myocardium: implications for clinical trials

Virginie Forest; Ashok Tirouvanziam; Christian Perigaud; Sarah Fernandes; Marion S Fusellier; Jean-Claude Desfontis; Claire Toquet; Marie-Françoise M Heymann; Dominique Crochet; Patricia Lemarchand

IntroductionEarly randomized clinical trials of autologous bone marrow cardiac stem cell therapy have reported contradictory results highlighting the need for a better evaluation of protocol designs. This study was designed to quantify and compare whole body and heart cell distribution after intracoronary or peripheral intravenous injection of autologous bone marrow mononuclear cells in a porcine acute myocardial infarction model with late reperfusion.MethodsMyocardial infarction was induced using balloon inflation in the left coronary artery in domestic pigs. At seven days post-myocardial infarction, 1 × 10(8) autologous bone marrow mononuclear cells were labeled with fluorescent marker and/or 99mTc radiotracer, and delivered using intracoronary or peripheral intravenous injection (leg vein).ResultsScintigraphic analyses and Υ-emission radioactivity counting of harvested organs showed a significant cell fraction retained within the heart after intracoronary injection (6 ± 1.7% of injected radioactivity at 24 hours), whereas following peripheral intravenous cell injection, no cardiac homing was observed at 24 hours and cells were mainly detected within the lungs. Importantly, no difference was observed in the percentage of retained cells within the myocardium in the presence or absence of myocardial infarction. Histological evaluation did not show arterial occlusion in both animal groups and confirmed the presence of bone marrow mononuclear cells within the injected myocardium area.ConclusionsIntravenous bone marrow mononuclear cell injection was ineffective to target myocardium. Myocardial cell distribution following intracoronary injection did not depend on myocardial infarction presence, a factor that could be useful for cardiac cell therapy in patients with chronic heart failure of non-ischemic origin or with ischemic myocardium without myocardial infarction.


Journal of Thoracic Oncology | 2012

CCL2, Galectin-3, and SMRP Combination Improves the Diagnosis of Mesothelioma in Pleural Effusions

Christophe Blanquart; Fabien Gueugnon; Jean-Michel Nguyen; David Roulois; Laurent Cellerin; Christine Sagan; Christian Perigaud; Arnaud Scherpereel; Marc Grégoire

Introduction: Malignant pleural mesothelioma (MPM) is a highly aggressive tumor with poor prognosis. One major challenge for this disease is the development of new, early, and highly reliable diagnostic markers. The aim of this study was to compare the diagnostic value of the chemokine chemokine (C-C motif) ligand 2 (CCL2), galectin-3, and the secretory leukocyte peptidase inhibitor (SLPI) with soluble mesothelin-related peptides (SMRP), and to evaluate the diagnostic performance of marker combinations. Methods: The levels of the different markers were measured by enzyme-linked immunosorbent assay in pleural fluids from patients with MPM (n = 61), adenocarcinomas (ADCA, n = 25), or with benign pleural effusions (BPE, n = 15). Results: SMRP, SLPI, and CCL2 concentrations were significantly higher in pleural effusions from mesothelioma patients. Conversely, galectin-3 levels seemed to be elevated in patients with pulmonary ADCA. Receiver operating characteristic curve analysis revealed that SMRP (area under the curve [AUC] = 0.9059), CCL2 (AUC = 0.7912), galectin-3 (AUC = 0.7584), and SLPI (AUC = 0.7219) were potentially interesting biomarkers for the differentiation of MPM patients from those with BPE or ADCA. Of interest, we showed that the combination of SMRP/CCL2/galectin-3 greatly improved MPM diagnosis (AUC = 0.9680), when compared with SMRP alone. Conclusion: The combination of SMRP/CCL2/galectin-3 seems to represent a promising panel of biomarkers for the reliable diagnosis of MPM in pleural fluids.


Radiotherapy and Oncology | 2011

Helical tomotherapy for resected malignant pleural mesothelioma: dosimetric evaluation and toxicity.

P. Giraud; Alma Sylvestre; S. Zefkili; A. Lisbona; Pierre Bonnette; Françoise Le Pimpec Barthes; Edouard Paris; Christian Perigaud; Alexia Savignoni; M.-A. Mahé

This study evaluated adjuvant helical tomotherapy after extrapleural pneumonectomy ± neo-adjuvant chemotherapy in 24 patients with malignant pleural mesothelioma. Toxicity was judged acceptable despite 2 cases (8%) of suspected grade 5 pneumonitis. With a mean follow-up of 7 months, 5 patients had distant and 2 local and distant failure.


Circulation | 2014

Early Structural Valve Deterioration of Mitroflow Aortic Bioprosthesis

Thomas Sénage; Thierry Le Tourneau; Yohann Foucher; Sabine Pattier; Caroline Cueff; Magali Michel; Jean-Michel Serfaty; Antoine Mugniot; Christian Perigaud; Hubert François Carton; Ousama Al Habash; Olivier Baron; Jean Christian Roussel

Background— Structural valve deterioration (SVD) is a major flaw of bioprostheses. Early SVD has been suspected in the last models of Mitroflow bioprosthesis. We sought to assess the incidence, mode, and impact of SVD on outcome in a large series of Mitroflow aortic valve replacement. Methods and Results— Six hundred seventeen consecutive patients (aged 76.1±6.3 years) underwent aortic valve replacement with a Mitroflow prosthesis (models 12A/LX) between 2002 and 2007. By echocardiography, 39 patients developed early SVD (1.66% per patient-year), with stenosis as the main mode (n=36). Mean delay to SVD was only 3.8±1.4 years, and 5-year SVD-free survival was 91.6% (95% confidence interval [CI], 88.7–94.7) for the whole cohort and 79.8% (95% CI, 71.2–89.4) and 94.0% (95% CI, 90.3–97.8) for 19- and 21-mm sizes, respectively. Among the 39 patients with SVD, 13 patients (33%) had an accelerated SVD once the mean gradient exceeded 30 mm Hg. Valve-related death was 46.2% in this SVD subgroup. Five-year overall survival was 69.6% (95% CI, 65.7–73.9). In multivariable analysis, SVD was the strongest correlate of overall mortality (hazard ratio=7.7; 95% CI, 4.4–13.6). Conclusions— Early SVD is frequent in Mitroflow bioprosthesis (models 12A/LX), especially for small sizes (19 and 21 mm), and reduces overall survival. An unpredictable accelerated pattern of SVD constitutes a life-threatening condition. In view of the large number of Mitroflow valves implanted worldwide, one can expect an epidemic of SVD and valve-related deaths, which represents a major public health issue, especially in the elderly. Hence, a close follow-up with yearly echocardiography after Mitroflow implantation is advisable. An urgent reoperation should be discussed in patients with severe SVD even though they are still asymptomatic.Background— Structural valve deterioration (SVD) is a major flaw of bioprostheses. Early SVD has been suspected in the last models of Mitroflow bioprosthesis. We sought to assess the incidence, mode, and impact of SVD on outcome in a large series of Mitroflow aortic valve replacement. Methods and Results— Six hundred seventeen consecutive patients (aged 76.1±6.3 years) underwent aortic valve replacement with a Mitroflow prosthesis (models 12A/LX) between 2002 and 2007. By echocardiography, 39 patients developed early SVD (1.66% per patient-year), with stenosis as the main mode (n=36). Mean delay to SVD was only 3.8±1.4 years, and 5-year SVD-free survival was 91.6% (95% confidence interval [CI], 88.7–94.7) for the whole cohort and 79.8% (95% CI, 71.2–89.4) and 94.0% (95% CI, 90.3–97.8) for 19- and 21-mm sizes, respectively. Among the 39 patients with SVD, 13 patients (33%) had an accelerated SVD once the mean gradient exceeded 30 mm Hg. Valve-related death was 46.2% in this SVD subgroup. Five-year overall survival was 69.6% (95% CI, 65.7–73.9). In multivariable analysis, SVD was the strongest correlate of overall mortality (hazard ratio=7.7; 95% CI, 4.4–13.6). Conclusions— Early SVD is frequent in Mitroflow bioprosthesis (models 12A/LX), especially for small sizes (19 and 21 mm), and reduces overall survival. An unpredictable accelerated pattern of SVD constitutes a life-threatening condition. In view of the large number of Mitroflow valves implanted worldwide, one can expect an epidemic of SVD and valve-related deaths, which represents a major public health issue, especially in the elderly. Hence, a close follow-up with yearly echocardiography after Mitroflow implantation is advisable. An urgent reoperation should be discussed in patients with severe SVD even though they are still asymptomatic. # CLINICAL PERSPECTIVE {#article-title-37}


Circulation | 2014

Early Structural Valve Deterioration of Mitroflow Aortic BioprosthesisCLINICAL PERSPECTIVE: Mode, Incidence, and Impact on Outcome in a Large Cohort of Patients

Thomas Sénage; Thierry Le Tourneau; Yohann Foucher; Sabine Pattier; Caroline Cueff; Magali Michel; Jean-Michel Serfaty; Antoine Mugniot; Christian Perigaud; Hubert François Carton; Ousama Al Habash; Olivier Baron; Jean Christian Roussel

Background— Structural valve deterioration (SVD) is a major flaw of bioprostheses. Early SVD has been suspected in the last models of Mitroflow bioprosthesis. We sought to assess the incidence, mode, and impact of SVD on outcome in a large series of Mitroflow aortic valve replacement. Methods and Results— Six hundred seventeen consecutive patients (aged 76.1±6.3 years) underwent aortic valve replacement with a Mitroflow prosthesis (models 12A/LX) between 2002 and 2007. By echocardiography, 39 patients developed early SVD (1.66% per patient-year), with stenosis as the main mode (n=36). Mean delay to SVD was only 3.8±1.4 years, and 5-year SVD-free survival was 91.6% (95% confidence interval [CI], 88.7–94.7) for the whole cohort and 79.8% (95% CI, 71.2–89.4) and 94.0% (95% CI, 90.3–97.8) for 19- and 21-mm sizes, respectively. Among the 39 patients with SVD, 13 patients (33%) had an accelerated SVD once the mean gradient exceeded 30 mm Hg. Valve-related death was 46.2% in this SVD subgroup. Five-year overall survival was 69.6% (95% CI, 65.7–73.9). In multivariable analysis, SVD was the strongest correlate of overall mortality (hazard ratio=7.7; 95% CI, 4.4–13.6). Conclusions— Early SVD is frequent in Mitroflow bioprosthesis (models 12A/LX), especially for small sizes (19 and 21 mm), and reduces overall survival. An unpredictable accelerated pattern of SVD constitutes a life-threatening condition. In view of the large number of Mitroflow valves implanted worldwide, one can expect an epidemic of SVD and valve-related deaths, which represents a major public health issue, especially in the elderly. Hence, a close follow-up with yearly echocardiography after Mitroflow implantation is advisable. An urgent reoperation should be discussed in patients with severe SVD even though they are still asymptomatic.Background— Structural valve deterioration (SVD) is a major flaw of bioprostheses. Early SVD has been suspected in the last models of Mitroflow bioprosthesis. We sought to assess the incidence, mode, and impact of SVD on outcome in a large series of Mitroflow aortic valve replacement. Methods and Results— Six hundred seventeen consecutive patients (aged 76.1±6.3 years) underwent aortic valve replacement with a Mitroflow prosthesis (models 12A/LX) between 2002 and 2007. By echocardiography, 39 patients developed early SVD (1.66% per patient-year), with stenosis as the main mode (n=36). Mean delay to SVD was only 3.8±1.4 years, and 5-year SVD-free survival was 91.6% (95% confidence interval [CI], 88.7–94.7) for the whole cohort and 79.8% (95% CI, 71.2–89.4) and 94.0% (95% CI, 90.3–97.8) for 19- and 21-mm sizes, respectively. Among the 39 patients with SVD, 13 patients (33%) had an accelerated SVD once the mean gradient exceeded 30 mm Hg. Valve-related death was 46.2% in this SVD subgroup. Five-year overall survival was 69.6% (95% CI, 65.7–73.9). In multivariable analysis, SVD was the strongest correlate of overall mortality (hazard ratio=7.7; 95% CI, 4.4–13.6). Conclusions— Early SVD is frequent in Mitroflow bioprosthesis (models 12A/LX), especially for small sizes (19 and 21 mm), and reduces overall survival. An unpredictable accelerated pattern of SVD constitutes a life-threatening condition. In view of the large number of Mitroflow valves implanted worldwide, one can expect an epidemic of SVD and valve-related deaths, which represents a major public health issue, especially in the elderly. Hence, a close follow-up with yearly echocardiography after Mitroflow implantation is advisable. An urgent reoperation should be discussed in patients with severe SVD even though they are still asymptomatic. # CLINICAL PERSPECTIVE {#article-title-37}

Collaboration


Dive into the Christian Perigaud's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

P. Giraud

Paris Descartes University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Alma Sylvestre

Hôpital Maisonneuve-Rosemont

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge