Christian Wallner
Siemens
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Christian Wallner.
Elektrotechnik Und Informationstechnik | 2004
G. Pilz; P. Schegner; Christian Wallner; Hans Michael Muhr; Stephan Pack
This article presents an algorithm for auto-reclosing of shunt compensated transmission lines. The algorithm uses signal analysis methods to estimate the future voltage shape over the circuit-breaker. Based on this voltage shape switching instants are estimated in the zero crossings. The minimization of the probability of a prearcing is reduced be adding time shift parameters. These parameters take the limited rise of strength recovery of the circuit breaker and the mutual influence of the coupling of the poles by a three-pole auto-reclosing into consideration. The advantage of the descript method is significant reduction of the switching overvoltage.ZusammenfassungDieser Artikel beschreibt einen Algorithmus für die kontrollierte Wiedereinschaltung auf parallel-kompensierten Übertragungsleitungen. Der Algorithmus verwendet ein Signalanalyseverfahren zur Berechnung des zukünftigen Verlaufs der Spannung über dem Leistungsschalter. Mit Hilfe des berechneten Spannungsverlaufs ist eine Bestimmung von Nulldurchgängen als Einschaltzeitpunkte möglich. Die Wahrscheinlichkeit eines Vorüberschlages wird durch Addition eines Verschiebezeitparameters minimiert. Dieser Parameter berücksichtigt den Verlauf der Einschaltkennlinie des Leistungsschalters und die Beeinflussung der einzeinen Leiter untereinander bei einer dreipoligen automatischen Wiedereinschaltung. Der Vorteil des beschriebenen Verfahrens ist eine bedeutende Reduzierung der Schaltüberspannung.
international conference on high voltage engineering and application | 2008
Mark Kuschel; Christian Wallner; Alfred Gerer
This paper presents the latest developments in and aspects of gas-insulated switchgear- (GIS) and gas-insulated-transmission line (GIL) technologies. The first 2-cycle GIS circuit breaker for a rated voltage of 550 kV and a rated short-circuit breaking current of 63 kA, which is based on a self-compression interrupter system and a storedenergy spring mechanism is presented, for example. Aspects, such as resistance to earthquakes as well as point-on-wave switching are described as well.
Archive | 2006
Georg Pilz; Peter Schegner; Christian Wallner
Archive | 2007
Heiko Jahn; Christian Wallner
Archive | 2006
Georg Pilz; Peter Schegner; Christian Wallner
Archive | 2006
Georg Pilz; Peter Schegner; Christian Wallner
Archive | 2014
Joerg Gorablenkow; Ivan Hasnek; Christian Wallner
Archive | 2007
Lutz-Rüdiger Jänicke; Christian Wallner
Archive | 2006
Heiko Jahn; Christian Wallner
Archive | 2006
Lutz-Rüdiger Jänicke; Christian Wallner