Christof Finkler
Hoffmann-La Roche
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Christof Finkler.
Journal of Chromatography B | 2015
Bernd Moritz; Volker Schnaible; Steffen Kiessig; Andrea Heyne; Markus Wild; Christof Finkler; Stefan Christians; Kerstin Mueller; Li Zhang; Kenji Furuya; Marc Hassel; Melissa Hamm; Richard R. Rustandi; Yan He; Oscar Salas Solano; Colin Whitmore; Sung Ae Park; Dietmar Hansen; Marcia Santos; Mark Lies
Within pharmaceutical industry charge heterogeneity testing of biopharmaceuticals has to be reproducible and fast. It should pass method validation according to ICH Q2. Classical approaches for the analysis of the charge heterogeneity of biopharmaceuticals are ion exchange chromatography (IEC) and isoelectric focusing (IEF). As an alternative approach, also capillary zone electrophoresis (CZE) was expected to allow reliable charge heterogeneity profiling by separation according to the analytes net charge and hydrodynamic radius. Aim of this study was to assess if CZE possesses all of the required features. Therefore, beside lab internal validation of this method also an international cross company study was organized. It was shown that CZE is applicable across a broad pI range between 7.4 and 9.5. The coefficient of correlation was above 0.99 which demonstrated linearity. Precision by repeatability was around 1% (maximum relative standard deviation per level) and accuracy by recovery was around 100% (mean recovery per level). Accuracy was further verified by direct comparison of IEC, IEF and CZE, which in this case showed comparable %CPA results for all three methods. However, best resolution for the investigated MAb was obtained with CZE. In dependence on sample concentration the detection limit was between 1 and 3%. Within the intercompany study for CZE the same stressed and non-stressed samples were analyzed in each of the 11 participating labs. The finally obtained dataset contained more than 1000 separations which provided an extended dataset for further statistical evaluation. Among the different labs no significant differences between the peak profiles were observed. Mean driver for dropouts in quantitative evaluation was linked to the performance of some participating labs while the impact of the method performance was negligible. In comparison to a 50cm capillary there was a slightly better separation of impurities and drug substance related compounds with a 30cm capillary which demonstrates that an increased stability indicating potential can be combined with the increased separation velocity and high throughput capability of a shorter capillary. Separation can be performed in as little as approx. 3min allowing high throughput applications. The intercompany study delivered precise results without explicit training of the participating labs in the method prior to the study (standard deviations in the range of 1%). It was demonstrated that CZE is an alternative platform technology for the charge heterogeneity testing of antibodies in the pharmaceutical industry.
Journal of Pharmaceutical Sciences | 2015
Emilien Folzer; Katharina Diepold; Katrin Bomans; Christof Finkler; Roland Schmidt; Patrick Bulau; Jörg Huwyler; Hanns-Christian Mahler; Atanas V. Koulov
Oxidation of methionine and tryptophan are common degradation pathways for monoclonal antibodies and present major analytical challenges in biotechnology. Generally, protein oxidation is detectable in stability and/or stressed samples (e.g., exposed to hydrogen peroxide, UV light, or metal ions). The induced chemical modifications may impact the biological activity of antibodies and may have biological consequences. However, these effects and the contribution of individual protein modifications are difficult to delineate as different amino acids are often oxidized simultaneously and accompanied by other degradants such as aggregates, especially in forced degradation studies. Here, we report a new method to obtain selective oxidation of methionine or tryptophan by using oxidation reagents combined with large excess of free tryptophan or methionine, correspondingly. More specifically, using hydrogen peroxide or tert-butyl hydroperoxide in combination with addition of free tryptophan allowed for selective oxidation of methionine. Conversely, the use of 2,2-azobis(2-amidinopropane) dihydrochloride in combination with free methionine resulted in selective tryptophan oxidation, whereas methionine oxidation was not significantly altered. This novel stress model system may prove to be valuable tool in future mechanistic studies of oxidative degradation of protein therapeutics.
Biologicals | 2016
J. Felix Kepert; Mary Cromwell; Niklas Engler; Christof Finkler; Gerald Gellermann; Lynn A. Gennaro; Reed J. Harris; Raquel Iverson; Brian Kelley; Lynne A. Krummen; Nathan McKnight; Paul Motchnik; Volker Schnaible; Ron Taticek
Quality by design (QbD) is a global regulatory initiative with the goal of enhancing pharmaceutical development through the proactive design of pharmaceutical manufacturing process and controls to consistently deliver the intended performance of the product. The principles of pharmaceutical development relevant to QbD are described in the ICH guidance documents (ICHQ8-11). An integrated set of risk assessments and their related elements developed at Roche/Genentech were designed to provide an overview of product and process knowledge for the production of a recombinant monoclonal antibody. This chapter describes the elements and tools used to establish acceptance criteria and an attribute testing strategy (ATS) for product variants and process related impurities. The acceptable ranges for CQAs are set based on their potential impact on efficacy and safety/immunogenicity. This approach is focused on the management of patient impacts, rather than simply maintaining a consistent analytical profile. The ATS tools were designed to identify quality attributes that required process and/or testing controls, or that could be captured in a monitoring system to enable lifecycle management of the control strategy.
Molecular Pharmaceutics | 2017
Bjoern Boll; Juliana Bessa; Emilien Folzer; Anacelia Ríos Quiroz; Roland Schmidt; Patrick Bulau; Christof Finkler; Hanns-Christian Mahler; Jörg Huwyler; Antonio Iglesias; Atanas V. Koulov
A current concern with the use of therapeutic proteins is the likely presence of aggregates and submicrometer, subvisible, and visible particles. It has been proposed that aggregates and particles may lead to unwanted increases in the immune response with a possible impact on safety or efficacy. The aim of this study was thus to evaluate the ability of subvisible particles of a therapeutic antibody to break immune tolerance in an IgG1 transgenic mouse model and to understand the particle attributes that might play a role in this process. We investigated the immunogenic properties of subvisible particles (unfractionated, mixed populations, and well-defined particle size fractions) using a transgenic mouse model expressing a mini-repertoire of human IgG1 (hIgG1 tg). Immunization with proteinaceous subvisible particles generated by artificial stress conditions demonstrated that only subvisible particles bearing very extensive chemical modifications within the primary amino acid structure could break immune tolerance in the hIgG1 transgenic mouse model. Protein particles exhibiting low levels of chemical modification were not immunogenic in this model.
Journal of Pharmaceutical Sciences | 2015
Emilien Folzer; Tarik A. Khan; Roland Schmidt; Christof Finkler; Jörg Huwyler; Hanns-Christian Mahler; Atanas V. Koulov
One of the analytical tools for characterization of subvisible particles, which gained popularity over the last years because of its unique capabilities, is the resonance mass measurement technique. However, a challenge that this technique presents is the need to know the exact density of the measured particles in order to obtain accurate size calculations. The density of proteinaceous subvisible particles has not been measured experimentally yet and to date researchers have been using estimated density values. In this paper, we report for a first-time experimental measurements of the density of protein particles (0.2-5 μm in size) using particles created by stressing three different proteins using four different types of stress conditions. Interestingly, the particle density values that were measured varied between 1.28 and 1.33 g/cm(3) and were lower than previous estimates. Furthermore, it was found that although the density of proteinaceous particles was affected to a very low degree by the stress conditions used to generate them, there is relatively larger difference between particles originating from different classes of proteins (e.g., monoclonal antibody vs. bovine serum albumin).
mAbs | 2016
Friederike Plath; Philippe Ringler; Alexandra Graff-Meyer; Henning Stahlberg; Matthias E. Lauer; Arne C. Rufer; Dmitri I. Svergun; Gerald Gellermann; Christof Finkler; Jan Olaf Stracke; Atanas V. Koulov; Volker Schnaible
ABSTRACT The formation of undesired high molecular weight species such as dimers is an important quality attribute for therapeutic monoclonal antibody formulations. Therefore, the thorough understanding of mAb dimerization and the detailed characterization mAb dimers is of great interest for future pharmaceutical development of therapeutic antibodies. In this work, we focused on the analyses of different mAb dimers regarding size, surface properties, chemical identity, overall structure and localization of possible dimerization sites. Dimer fractions of different mAbs were isolated to a satisfactory purity from bulk material and revealed 2 predominant overall structures, namely elongated and compact dimer forms. The elongated dimers displayed one dimerization site involving the tip of the Fab domain. Depending on the stress applied, these elongated dimers are connected either covalently or non-covalently. In contrast, the compact dimers exhibited non-covalent association. Several interaction points were detected for the compact dimers involving the hinge region or the base of the Fab domain. These results indicate that mAb dimer fractions are rather complex and may contain more than one kind of dimer. Nevertheless, the overall appearance of mAb dimers suggests the existence of 2 predominant dimeric structures, elongated and compact, which are commonly present in preparations of therapeutic mAbs.
Pharmaceutical Research | 2016
Anacelia Ríos Quiroz; Jens Lamerz; Thierry Da Cunha; Adeline Boillon; Michael Adler; Christof Finkler; Joerg Huwyler; Roland Schmidt; Hanns-Christian Mahler; Atanas V. Koulov
PurposeThe current study was performed to assess the precision of the principal subvisible particle measurement methods available today. Special attention was given to identifying the sources of error and the factors governing analytical performance.MethodsThe performance of individual techniques was evaluated using a commercial biologic drug product in a prefilled syringe container. In control experiments, latex spheres were used as standards and instrument calibration suspensions.ResultsThe results reported in this manuscript clearly demonstrated that the particle measurement techniques operating in the submicrometer range have much lower precision than the micrometer size-range methods. It was established that the main factor governing the relatively poor precision of submicrometer methods in general and inherently, is their low sampling volume and the corresponding large extrapolation factors for calculating final results.ConclusionsThe variety of new methods for submicrometer particle analysis may in the future support product characterization; however, the performance of the existing methods does not yet allow for their use in routine practice and quality control.
Pda Journal of Pharmaceutical Science and Technology | 2016
Serge Mathonet; Hanns-Christian Mahler; Stefan T. Esswein; Maryam Mazaheri; Patricia W. Cash; Klaus Wuchner; Georg Kallmeyer; Tapan Kanti Das; Christof Finkler; Andrew Lennard
Regulatory monographs in Europe and the United States require drug products for parenteral administration to be “practically free” or “essentially free” of visible particles, respectively. Both terms have been used interchangeably and acknowledge the probabilistic nature of visual particle inspection. The probability of seeing a particle in a drug product container varies according to the size and nature of the particles as well as container and inspection conditions. Therefore, the term “without visible particles” can be highly misleading in the context of what is practically achievable. This may lead to differences in understanding between industry practitioners and regulatory agencies. Is this term intended to mean “zero particles”, or is there any intention to distinguish between particle type such as “zero extraneous visible particles” or “zero proteinaceous particles”? Furthermore, how can “zero” particles as a criterion for release testing be reconciled with “practically free from particles” as stated in the definition and a low, justified level of proteinaceous particles after production? The purpose of this position paper is to review best practices in the industry in terms of visual inspection process and associated operator training, quality control sampling, testing, and setting acceptance criteria corresponding to “practically free of visible particles” and providing considerations when visible proteinaceous particles are deemed unavoidable. It also provides a brief overview of visible particle characterization and gives perspectives on patient safety. This position paper applies to biotechnology-derived drug products including monoclonal antibodies in late-phase development to licensed products. LAY ABSTRACT: In the 2011 monoclonal antibody monograph revision, European Pharmacopoeia experts acknowledged that protein products may also contain proteinaceous particles at release or that protein particles may form during storage. Indeed, industry experience has demonstrated that therapeutic proteins such as monoclonal antibodies can exhibit a propensity for self-association leading to the formation of aggregates that range in size from nanometres (oligomers) to microns (subvisible and visible particles). As a result, the requirement for drug product appearance for monoclonal antibodies was changed from “without visible particles” to “without visible particles unless otherwise authorised or justified”. In our view, “practically free from particles” should be considered a suitable acceptance criterion for injectable biotechnology and small-molecule products, as long as appropriately defined. Furthermore, we argue that visual inspection is a suitable quality control release test and that “practically free from particles” is a suitable specification when adequately described.
Journal of Pharmaceutical Sciences | 2016
Anacelia Ríos Quiroz; Christof Finkler; Joerg Huwyler; Hanns-Christian Mahler; Roland Schmidt; Atanas V. Koulov
A number of new techniques for subvisible particle characterization in biotechnological products have emerged in the last decade. Although the pharmaceutical community is actively using them, the current knowledge about the analytical performance of some of these tools is still inadequate to support their routine use in the development of biopharmaceuticals (especially in the case of submicron methods). With the aim of increasing this knowledge and our understanding of the most prominent techniques for subvisible particle characterization, this study reports the results of a systematic evaluation of their accuracy. Our results showed a marked overcounting effect especially for low concentrated samples and particles fragile in nature. Furthermore, we established the relative sample size distribution as the most important contributor to an instruments performance in accuracy counting. The smaller the representation of a particle size within a solution, the more difficulty the instruments had in providing an accurate count. These findings correlate with a recent study examining the principal factors influencing the precision of the subvisible particle measurements. A more thorough understanding of the capabilities of the different particle characterization methods provided here will help guide the application of these methods and the interpretation of results in subvisible particle characterization studies.
Electrophoresis | 2017
Bernd Moritz; Valentina Locatelli; Michele Niess; Andrea Bathke; Steffen Kiessig; Barbara Entler; Christof Finkler; Harald Wegele; Jan Olaf Stracke
CZE is a well‐established technique for charge heterogeneity testing of biopharmaceuticals. It is based on the differences between the ratios of net charge and hydrodynamic radius. In an extensive intercompany study, it was recently shown that CZE is very robust and can be easily implemented in labs that did not perform it before. However, individual characteristics of some examined proteins resulted in suboptimal resolution. Therefore, enhanced method development principles were applied here to investigate possibilities for further method optimization. For this purpose, a high number of different method parameters was evaluated with the aim to improve CZE separation. For the relevant parameters, design of experiments (DoE) models were generated and optimized in several ways for different sets of responses like resolution, peak width and number of peaks. In spite of product specific DoE optimization it was found that the resulting combination of optimized parameters did result in significant improvement of separation for 13 out of 16 different antibodies and other molecule formats. These results clearly demonstrate generic applicability of the optimized CZE method. Adaptation to individual molecular properties may sometimes still be required in order to achieve optimal separation but the set screws discussed in this study [mainly pH, identity of the polymer additive (HPC versus HPMC) and the concentrations of additives like acetonitrile, butanolamine and TETA] are expected to significantly reduce the effort for specific optimization.