Christoph Gasser
Vienna University of Technology
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Christoph Gasser.
Analytical Chemistry | 2011
Bernhard Zachhuber; Christoph Gasser; Engelene t. H. Chrysostom; Bernhard Lendl
A pulsed (4.4 ns pulse length) frequency-doubled Nd:YAG laser operated at 10 Hz was used to generate Raman scattering of samples at a distance of 12 m. The scattered light was collected by a 6 in. telescope, and the Raman spectrum was recorded using an Acton SP-2750 spectrograph coupled to a gated intensified charge-coupled device (ICCD) detector. Applying a spatial offset between the point where the laser hit the sample and the focus of the telescope on the sample enabled collection of Raman photons that were predominantly generated inside the sample and not from its surface. This is especially effective when the content of concealed objects should be analyzed. High-quality Raman spectra could be recorded, within 10 s of data acquisition, from a solid (NaClO(3)) as well as a liquid (isopropyl alcohol) placed inside a 1.5 mm thick opaque low-density polyethylene (LDPE) plastic bottle. The applied spatial offset was also advantageous in cases where the surface of the container was highly fluorescent. In such a situation, Raman spectra of the sample could not be recorded when the sampling volume (telescope observation field) coincided with the focus of the excitation laser. However, with the use of a spatial offset of some millimeters, a clear Raman spectrum of the content (isopropyl alcohol) in a strongly fluorescent plastic container was obtained.
Analytical Chemistry | 2013
Gregor Hommes; Christoph Gasser; Erik M. Ammann; Philippe F.-X. Corvini
High-throughput multiparallel activity profiling for oxygen consuming cell layers has been recently developed for extracellular flux analysis. This technology has great potential for determining the enzymatic activity of oxidoreductases (i.e., laccase) both in vivo and in vitro, which is usually measured using photometrical tests monitoring the colored oxidation products. Improvements in terms of sample throughput, comparability, and gain of information (i.e., stoichiometry, electron transfer rate) can be achieved by means of a multiwell plate-based fluorimetric oxygen sensor. In the present study, various laccases have been applied to develop protocols that allow the multiparallel measurement of O(2)-consumption by enzymatic reactions. The developed and validated method enables the comparative quantitation of laccase characteristics (i.e., profiles of activity at various pH values) and minimizes the time it usually takes to collect respiratory data of oxygen-consuming enzymes. Furthermore, the possibility to assess differences between single and multisubstrate kinetics of laccases has been demonstrated.
Applied Spectroscopy | 2012
Bernhard Zachhuber; Christoph Gasser; Georg Ramer; Engelene t. H. Chrysostom; Bernhard Lendl
Time-resolved stand-off Raman spectroscopy was used to determine both the position and identity of substances relative to each other at remote distances (up to tens of meters). Spectral information of three xylene isomers, toluene, and sodium chlorate was obtained at a distance of 12 m from the setup. Pairs and triplets of these samples were placed at varying distances (10–60 cm) relative to each other. Via the photon time of flight the distance between the individual samples was determined to an accuracy of 7% (corresponding to a few cm) of the physically measured distance. Furthermore, at a distance of 40 m, time-resolved Raman depth profiling was used to detect sodium chlorate in a white plastic container that was non-transparent to the human eye. The combination of the ranging capabilities of Raman LIDAR (sample location usually determined using prior knowledge of the analyte of interest) with stand-off Raman spectroscopy (analyte detection at remote distances) provides the capability for depth profile identification of unknown substances and analysis of concealed content in distant objects. To achieve these results, a 532 nm laser with a pulse length of 4.4 ns was synchronized to an intensified charge-coupled device camera with a minimum gate width of 500 ps. For automated data analysis a multivariate curve resolution algorithm was employed.
Optics and Photonics for Counterterrorism and Crime Fighting VII; Optical Materials in Defence Systems Technology VIII; and Quantum-Physics-based Information Security | 2011
Bernhard Zachhuber; Christoph Gasser; Alison J. Hobro; Engelene t. H. Chrysostom; Bernhard Lendl
A pulsed (4.4 ns pulse length) frequency doubled Nd:YAG laser, operating at 10 Hz, was used to generate Raman scattering from samples at a distance of 12 m. The scattered light was collected by a 6 inch telescope and the Raman spectrum recorded using an Acton SP-2750 spectrograph coupled to a gated ICCD detector. To extend the potential applications further, employing a spatial offset between the point where the laser hit the sample and the focus of the telescope on the sample, enabled collection of Raman photons that were predominantly generated inside the sample and not from its surface. This is especially effective when the content of concealed objects should be analysed. Raman spectra of H2O2 in a 1.5 mm thick, fluorescent HDPE plastic bottle were recorded at a distance of 12 m. From the recorded spectra it was possible to determine the H2O2 concentration in the concentration range from 2-30%. Stand-off Raman spectra of eleven potentially dangerous chemicals (commercial and improvised explosives) were recorded at a distance of 100 m.
Laser Applications to Chemical, Security and Environmental Analysis | 2012
Bernhard Lendl; Bernhard Zachhuber; Christoph Gasser; Engelene t. H. Chrysostom
Identification and quantification of potentially harmful substances concealed in fluorescent containers were achieved at a distance of 12 metres using stand off spatial offset Raman scattering.
Analytical and Bioanalytical Chemistry | 2017
Andreas Genner; Christoph Gasser; Harald Moser; Johannes Ofner; Josef Schreiber; Bernhard Lendl
Sensors and Actuators B-chemical | 2017
Christoph Gasser; Andreas Genner; Harald Moser; Johannes Ofner; Bernhard Lendl
conference on lasers and electro optics | 2018
Harald Moser; Johannes Paul Waclawek; Andreas Genner; Christoph Gasser; Bernhard Lendl
Optics Express | 2018
Christoph Gasser; Jakob Kilgus; Michael Harasek; Bernhard Lendl; Markus Brandstetter
Chemical Engineering Journal | 2018
Bahram Haddadi; Christoph Gasser; Christian Jordan; Michael Harasek; Bernhard Lendl