Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Christopher W. Oates is active.

Publication


Featured researches published by Christopher W. Oates.


Science | 2013

An Atomic Clock with 10–18 Instability

N. Hinkley; Jeff Sherman; N. B. Phillips; M. Schioppo; Nathan D. Lemke; K. Beloy; M. Pizzocaro; Christopher W. Oates; Andrew D. Ludlow

Tick, Tick, Tick… Many aspects of everyday life from communication to navigation rely on the precise ticking of the microwave transitions of the atoms in atomic clocks. Optical transitions occur at much higher frequency and so offer the opportunity to reduce the scale of the ticks even more. Hinkley et al. (p. 1215, published online 22 August; see the Perspective by Margolis) compare the ticking of two optical clocks and report an instability near the 10−18 level. Such performance will improve tests of general relativity and pave the way for a redefinition of the second. An ytterbium-based optical clock exhibits a precision of nearly one part per quintillion. [Also see Perspective by Margolis] Atomic clocks have been instrumental in science and technology, leading to innovations such as global positioning, advanced communications, and tests of fundamental constant variation. Timekeeping precision at 1 part in 1018 enables new timing applications in relativistic geodesy, enhanced Earth- and space-based navigation and telescopy, and new tests of physics beyond the standard model. Here, we describe the development and operation of two optical lattice clocks, both using spin-polarized, ultracold atomic ytterbium. A measurement comparing these systems demonstrates an unprecedented atomic clock instability of 1.6 × 10–18 after only 7 hours of averaging.


Science | 2009

Probing Interactions Between Ultracold Fermions

Gretchen K. Campbell; Micah Boyd; Jan Thomsen; Michael J. Martin; Sebastian Blatt; Matthew Swallows; Travis Nicholson; Tara M. Fortier; Christopher W. Oates; Scott A. Diddams; Nathan D. Lemke; Pascal Naidon; Paul S. Julienne; J. Ye; Andrew D. Ludlow

At ultracold temperatures, the Pauli exclusion principle suppresses collisions between identical fermions. This has motivated the development of atomic clocks with fermionic isotopes. However, by probing an optical clock transition with thousands of lattice-confined, ultracold fermionic strontium atoms, we observed density-dependent collisional frequency shifts. These collision effects were measured systematically and are supported by a theoretical description attributing them to inhomogeneities in the probe excitation process that render the atoms distinguishable. This work also yields insights for zeroing the clock density shift.


Nature Photonics | 2017

Ultrastable optical clock with two cold-atom ensembles

M. Schioppo; R.C. Brown; William McGrew; N. Hinkley; Robert Fasano; K. Beloy; T.H. Yoon; Gianmaria Milani; Daniele Nicolodi; Jeff Sherman; N. B. Phillips; Christopher W. Oates; Andrew D. Ludlow

Optical clocks with a record low zero-dead-time instability of 6 × 10–17 at 1 second are demonstrated in two cold-ytterbium systems. The two systems are interrogated by a shared optical local oscillator to nearly eliminate the Dick effect. Atomic clocks based on optical transitions are the most stable, and therefore precise, timekeepers available. These clocks operate by alternating intervals of atomic interrogation with the ‘dead’ time required for quantum state preparation and readout. This non-continuous interrogation of the atom system results in the Dick effect, an aliasing of frequency noise from the laser interrogating the atomic transition1,2. Despite recent advances in optical clock stability that have been achieved by improving laser coherence, the Dick effect has continually limited the performance of optical clocks. Here we implement a robust solution to overcome this limitation: a zero-dead-time optical clock that is based on the interleaved interrogation of two cold-atom ensembles3. This clock exhibits vanishingly small Dick noise, thereby achieving an unprecedented fractional frequency instability assessed to be for an averaging time τ in seconds. We also consider alternate dual-atom-ensemble schemes to extend laser coherence and reduce the standard quantum limit of clock stability, achieving a spectroscopy line quality factor of Q > 4 × 1015.


Nature Photonics | 2011

Generation of ultrastable microwaves via optical frequency division

Tara M. Fortier; Matthew S. Kirchner; Franklyn Quinlan; Jacob M. Taylor; J. C. Bergquist; T. Rosenband; Nathan D. Lemke; Andrew D. Ludlow; Yanyi Jiang; Christopher W. Oates; Scott A. Diddams

Researchers demonstrate a microwave generator based on a high-Q optical resonator and a frequency comb functioning as an optical-to-microwave divider. They generate 10 GHz electrical signals with a fractional frequency instability of ≤8 × 10−16 at 1 s.


Science | 2008

Sr Lattice Clock at 1 x 10-16 Fractional Uncertainty by Remote Optical Evaluation with a Ca Clock

Andrew D. Ludlow; Tanya Zelevinsky; Gretchen K. Campbell; Sebastian Blatt; Martin M. Boyd; M. H. G. de Miranda; Michael J. Martin; Jan Thomsen; J. Ye; Tara M. Fortier; J. E. Stalnaker; Scott A. Diddams; Y. Le Coq; Zeb W. Barber; N. Poli; Nathan D. Lemke; K. M. Beck; Christopher W. Oates

Optical atomic clocks promise timekeeping at the highest precision and accuracy, owing to their high operating frequencies. Rigorous evaluations of these clocks require direct comparisons between them. We have realized a high-performance remote comparison of optical clocks over kilometer-scale urban distances, a key step for development, dissemination, and application of these optical standards. Through this remote comparison and a proper design of lattice-confined neutral atoms for clock operation, we evaluate the uncertainty of a strontium (Sr) optical lattice clock at the 1 × 10–16 fractional level, surpassing the current best evaluations of cesium (Cs) primary standards. We also report on the observation of density-dependent effects in the spin-polarized fermionic sample and discuss the current limiting effect of blackbody radiation–induced frequency shifts.


Nature Photonics | 2011

Making optical atomic clocks more stable with 10 −16 -level laser stabilization

Yanyi Jiang; Andrew D. Ludlow; Nathan D. Lemke; Richard W. Fox; Jeff Sherman; Long-Sheng Ma; Christopher W. Oates

Scientists demonstrate a cavity-stabilized laser system with a reduced thermal noise floor, exhibiting a fractional frequency instability of 2 × 10−16. They use this system as a stable optical source in an ytterbium optical lattice clock to resolve an ultranarrow 1 Hz linewidth for the 518 THz clock transition. Consistent measurements with a clock instability of 5 × 10−16/√τ are reported.


Physical Review Letters | 2001

Absolute frequency measurements of the Hg+ and Ca optical clock transitions with a femtosecond laser.

Th. Udem; Scott A. Diddams; Kurt R. Vogel; Christopher W. Oates; E. A. Curtis; W D. Lee; Wayne M. Itano; Robert E. Drullinger; J. C. Bergquist; Leo W. Hollberg

The frequency comb created by a femtosecond mode-locked laser and a microstructured fiber is used to phase coherently measure the frequencies of both the Hg+ and Ca optical standards with respect to the SI second. We find the transition frequencies to be f(Hg) = 1 064 721 609 899 143(10) Hz and f(Ca) = 455 986 240 494 158(26) Hz, respectively. In addition to the unprecedented precision demonstrated here, this work is the precursor to all-optical atomic clocks based on the Hg+ and Ca standards. Furthermore, when combined with previous measurements, we find no time variations of these atomic frequencies within the uncertainties of the absolute value of( partial differential f(Ca)/ partial differential t)/f(Ca) < or =8 x 10(-14) yr(-1) and the absolute value of(partial differential f(Hg)/ partial differential t)/f(Hg) < or =30 x 10(-14) yr(-1).


IEEE Journal of Quantum Electronics | 2001

Optical frequency standards and measurements

Leo W. Hollberg; Christopher W. Oates; E. A. Curtis; Eugene Ivanov; Scott A. Diddams; Thomas Udem; Hugh Robinson; J. C. Bergquist; R. J. Rafac; Wayne M. Itano; Robert E. Drullinger; David J. Wineland

We describe the performance characteristics and frequency measurements of two high-accuracy high-stability laser-cooled atomic frequency standards. One is a 657-nm (456-THz) reference using magneto-optically trapped Ca atoms, and the other is a 282-nm (1064-THz) reference based on a single Hg/sup +/ ion confined in an RF-Paul trap. A femtosecond mode-locked laser combined with a nonlinear microstructure fiber produces a broad and stable comb of optical modes that is used to measure the frequencies of the reference lasers locked to the atomic standards. The measurement system is referenced to the primary frequency standard NIST F-1, a Cs atomic fountain clock. Both optical standards demonstrate exceptional short-term instability (/spl ap/5/spl times/10/sup -15/ at 1 s), as well as excellent reproducibility over time. In light of our expectations for the future of optical frequency standards, we consider the present performance of the femtosecond optical frequency comb, along with its limitations and future requirements.


Optics Letters | 2004

Stabilization of femtosecond laser frequency combs with subhertz residual linewidths

Albrecht Bartels; Christopher W. Oates; Leo W. Hollberg; Scott A. Diddams

We demonstrate that femtosecond laser frequency combs (FLFCs) can have a subhertz linewidth across their entire emission spectra when they are phase locked to a reference laser with a similarly narrow linewidth. Correspondingly, the coherence time of the comb components relative to the reference laser can be of the order of a few seconds. Thus we are able to detect high-contrast spectral interferograms at up to 10-s integration time between two FLFCs locked to a common optical reference.


Physical Review Letters | 2005

Observation and Absolute Frequency Measurements of the 1S0 - 3P0 Optical Clock Transition in Neutral Ytterbium

Chad Hoyt; Zeb W. Barber; Christopher W. Oates; Tara M. Fortier; Scott A. Diddams; Leo W. Hollberg

We report the direct excitation of the highly forbidden (6s2) 1S0 <--> (6s6p) 3P0 optical transition in two odd isotopes of neutral ytterbium. As the excitation laser frequency is scanned, absorption is detected by monitoring the depletion from an atomic cloud at approximately 70 microK in a magneto-optical trap. The measured frequency in 171Yb (F=1/2) is 518,295,836,591.6 +/- 4.4 kHz. The measured frequency in 173Yb (F=5/2) is 518,294,576,847.6 +/- 4.4 kHz. Measurements are made with a femtosecond-laser frequency comb calibrated by the National Institute of Standards and Technology cesium fountain clock and represent nearly a 10(6)-fold reduction in uncertainty. The natural linewidth of these J=0 to J=0 transitions is calculated to be approximately 10 mHz, making them well suited to support a new generation of optical atomic clocks based on confinement in an optical lattice.

Collaboration


Dive into the Christopher W. Oates's collaboration.

Top Co-Authors

Avatar

Leo W. Hollberg

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Scott A. Diddams

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Andrew D. Ludlow

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Tara M. Fortier

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Nathan D. Lemke

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Zeb W. Barber

Montana State University

View shared research outputs
Top Co-Authors

Avatar

E. A. Curtis

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

J. C. Bergquist

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

G Wilpers

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Chad Hoyt

National Institute of Standards and Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge