Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Chuansi Gao is active.

Publication


Featured researches published by Chuansi Gao.


Ergonomics | 2004

A systems perspective of slip and fall accidents on icy and snowy surfaces

Chuansi Gao; John Abeysekera

Current research on slips and falls has mainly focused on floors and/or contaminated floors. Although icy and snowy surfaces near melting temperature are more slippery, more important still, slip and falls on icy and snowy surfaces involve not only outdoor workers, but also pedestrians and the general public; and occur in cold regions and in the winter season in many parts of the world. However, in comparison with the size of the problem, research work done so far in this area has been limited. The objective of this paper is to present a systems perspective of slip and fall accidents, with special focus on its occurrence on icy and snowy surfaces. In order to explore the aetiology of slip and fall accidents further, and to provide the basis for prevention, the authors put forward a systems model towards the slips and falls on icy and snowy surfaces based on a review of literature and current knowledge. Various contributing factors are systematically discussed to highlight the multi-factorial nature of the problem, providing the possibility of a multi-faceted approach to reach systematic prevention. Unresolved issues related to slips and falls on ice and snow are also identified, which necessitate further research.


Ergonomics | 2010

Cooling vests with phase change material packs: the effects of temperature gradient, mass and covering area.

Chuansi Gao; Kalev Kuklane; Ingvar Holmér

Phase change material (PCM) absorbs or releases latent heat when it changes phases, making thermal-regulated clothing possible. The objective of this study was to quantify the relationships between PCM cooling rate and temperature gradient, mass and covering area on a thermal manikin in a climatic chamber. Three melting temperatures (24, 28, 32°C) of the PCMs, different mass, covering areas and two manikin temperatures (34 and 38°C) were used. The results showed that the cooling rate of the PCM vests tested is positively correlated with the temperature gradient between the thermal manikin and the melting temperature of the PCMs. The required temperature gradient is suggested to be greater than 6°C when PCM vests are used in hot climates. With the same temperature gradient, the cooling rate is mainly determined by the covering area. The duration of the cooling effect is dependent on PCM mass and the latent heat. Statement of Relevance: The study of factors affecting the cooling rate of personal cooling equipment incorporated with PCM helps to understand cooling mechanisms. The results suggest climatic conditions, the required temperature gradient, PCM mass and covering area should be taken into account when choosing personal PCM cooling equipment.


Indoor Air | 2012

Personal cooling with phase change materials to improve thermal comfort from a heat wave perspective

Chuansi Gao; Kalev Kuklane; Faming Wang; Ingvar Holmér

UNLABELLED The impact of heat waves arising from climate change on human health is predicted to be profound. It is important to be prepared with various preventive measures for such impacts on society. The objective of this study was to investigate whether personal cooling with phase change materials (PCM) could improve thermal comfort in simulated office work at 34°C. Cooling vests with PCM were measured on a thermal manikin before studies on human subjects. Eight male subjects participated in the study in a climatic chamber (T(a) = 34°C, RH = 60%, and ν(a) = 0.4 m/s). Results showed that the cooling effect on the manikin torso was 29.1 W/m(2) in the isothermal condition. The results on the manikin using a constant heating power mode reflect directly the local cooling effect on subjects. The results on the subjects showed that the torso skin temperature decreased by about 2-3°C and remained at 33.3°C. Both whole body and torso thermal sensations were improved. The findings indicate that the personal cooling with PCM can be used as an option to improve thermal comfort for office workers without air conditioning and may be used for vulnerable groups, such as elderly people, when confronted with heat waves. PRACTICAL IMPLICATIONS Wearable personal cooling integrated with phase change materials has the advantage of cooling human bodys micro-environment in contrast to stationary personalized cooling and entire room or building cooling, thus providing greater mobility and helping to save energy. In places where air conditioning is not usually used, this personal cooling method can be used as a preventive measure when confronted with heat waves for office workers, vulnerable populations such as the elderly and disabled people, people with chronic diseases, and for use at home.


International Journal of Occupational Safety and Ergonomics | 2010

A Review of Technology of Personal Heating Garments

Faming Wang; Chuansi Gao; Kalev Kuklane; Ingvar Holmér

Modern technology makes garments smart, which can help a wearer to manage in specific situations by improving the functionality of the garments. The personal heating garment (PHG) widens the operating temperature range of the garment and improves its protection against the cold. This paper describes several kinds of PHGs worldwide; their advantages and disadvantages are also addressed. Some challenges and suggestions are finally addressed with regard to the development of PHGs.


Physiological Measurement | 2011

Can the PHS model (ISO7933) predict reasonable thermophysiological responses while wearing protective clothing in hot environments

Faming Wang; Kalev Kuklane; Chuansi Gao; Ingvar Holmér

In this paper, the prediction accuracy of the PHS (predicted heat strain) model on human physiological responses while wearing protective clothing ensembles was examined. Six human subjects (aged 29 ± 3 years) underwent three experimental trials in three different protective garments (clothing thermal insulation I(cl) ranges from 0.63 to 2.01 clo) in two hot environments (40 °C, relative humidities: 30% and 45%). The observed and predicted mean skin temperature, core body temperature and sweat rate were presented and statistically compared. A significant difference was found in the metabolic rate between FIRE (firefighting clothing) and HV (high visibility clothing) or MIL (military clothing) (p < 0.001). Also, the development of heart rate demonstrated the significant effects of the exposure time and clothing ensembles. In addition, the predicted evaporation rate during HV, MIL and FIRE was much lower than the experimental values. Hence, the current PHS model is not applicable for protective clothing with intrinsic thermal insulations above 1.0 clo. The results showed that the PHS model generated unreliable predictions on body core temperature when human subjects wore thick protective clothing such as firefighting clothing (I(cl) > 1.0 clo). The predicted mean skin temperatures in three clothing ensembles HV, MIL and FIRE were also outside the expected limits. Thus, there is a need for further extension for the clothing insulation validation range of the PHS model. It is recommended that the PHS model should be amended and validated by individual algorithms, physical or physiological parameters, and further subject studies.


International Journal of Occupational Safety and Ergonomics | 2006

Test of Firefighter's Turnout Gear in Hot and Humid Air Exposure

Ingvar Holmér; Kalev Kuklane; Chuansi Gao

Five students of a rescue training school cycled at 50 W for 20 min at 20 °C before walking at 5 km/hr up to 30 min in a climatic chamber at 55 °C and 30% relative humidity. 4 different types of clothing ensembles differing in terms of thickness and thermal insulation value were tested on separate days. All subjects completed 28–30 min in light clothing, but quit after 20–27 min in 3 firefighter ensembles due to a rectal temperature of 39 °C or subjective fatigue. No difference in the evolution of mean skin or rectal temperature was seen for the 3 turnout ensembles. Sweat production amounted to about 1000 g in the turnout gears of which less than 20% evaporated. It was concluded that the small differences between the turnout gears in terms of design, thickness and insulation value had no effect on the resulting heat physiological strain for the given experimental conditions.


International Journal of Occupational Safety and Ergonomics | 2007

Calculation of clothing insulation by serial and parallel methods: effects on clothing choice by IREQ and thermal responses in the cold.

Kalev Kuklane; Chuansi Gao; Ingvar Holmér; Lina Giedraitytė; Peter Bröde; Victor Candas; Emiel den Hartog; Harriet Meinander; Mark Richards; George Havenith

Cold protective clothing was studied in 2 European Union projects. The objectives were (a) to examine different insulation calculation methods as measured on a manikin (serial or parallel), for the prediction of cold stress (IREQ); (b) to consider the effects of cold protective clothing on metabolic rate; (c) to evaluate the movement and wind correction of clothing insulation values. Tests were carried out on 8 subjects. The results showed the possibility of incorporating the effect of increases in metabolic rate values due to thick cold protective clothing into the IREQ model. Using the higher thermal insulation value from the serial method in the IREQ prediction, would lead to unacceptable cooling of the users. Thus, only the parallel insulation calculation method in EN 342:2004 should be used. The wind and motion correction equation (No. 2) gave realistic values for total resultant insulation; dynamic testing according to EN 342:2004 may be omitted.


Ergonomics | 2012

Localised boundary air layer and clothing evaporative resistances for individual body segments

Faming Wang; Simona Del Ferraro; Li-Yen Lin; Tiago Sotto Mayor; Vincenzo Molinaro; Miguel Ribeiro; Chuansi Gao; Kalev Kuklane; Ingvar Holmér

Evaporative resistance is an important parameter to characterise clothing thermal comfort. However, previous work has focused mainly on either total static or dynamic evaporative resistance. There is a lack of investigation of localised clothing evaporative resistance. The objective of this study was to study localised evaporative resistance using sweating thermal manikins. The individual and interaction effects of air and body movements on localised resultant evaporative resistance were examined in a strict protocol. The boundary air layers localised evaporative resistance was investigated on nude sweating manikins at three different air velocity levels (0.18, 0.48 and 0.78 m/s) and three different walking speeds (0, 0.96 and 1.17 m/s). Similarly, localised clothing evaporative resistance was measured on sweating manikins at three different air velocities (0.13, 0.48 and 0.70 m/s) and three walking speeds (0, 0.96 and 1.17 m/s). Results showed that the wind speed has distinct effects on local body segments. In contrast, walking speed brought much more effect on the limbs, such as thigh and forearm, than on body torso, such as back and waist. In addition, the combined effect of body and air movement on localised evaporative resistance demonstrated that the walking effect has more influence on the extremities than on the torso. Therefore, localised evaporative resistance values should be provided when reporting test results in order to clearly describe clothing local moisture transfer characteristics. Practitioner Summary: Localised boundary air layer and clothing evaporative resistances are essential data for clothing design and assessment of thermal comfort. A comprehensive understanding of the effects of air and body movement on localised evaporative resistance is also necessary by both textile and apparel researchers and industry.


Journal of Thermal Biology | 2015

A novel personal cooling system (PCS) incorporated with phase change materials (PCMs) and ventilation fans: An investigation on its cooling efficiency.

Yehu Lu; Fanru Wei; Dandan Lai; Wen Shi; Faming Wang; Chuansi Gao; Guowen Song

Personal cooling systems (PCS) have been developed to mitigate the impact of severe heat stress for humans working in hot environments. It is still a great challenge to develop PCSs that are portable, inexpensive, and effective. We studied the performance of a new hybrid PCS incorporating both ventilation fans and phase change materials (PCMs). The cooling efficiency of the newly developed PCS was investigated on a sweating manikin in two hot conditions: hot humid (HH, 34°C, 75% RH) and hot dry (HD, 34°C, 28% RH). Four test scenarios were selected: fans off with no PCMs (i.e., Fan-off, the CONTROL), fans on with no PCMs (i.e., Fan-on), fans off with fully solidified PCMs (i.e., PCM+Fan-off), and fans on with fully solidified PCMs (i.e., PCM+Fan-on). It was found that the addition of PCMs provided a 54∼78min cooling in HH condition. In contrast, the PCMs only offered a 19-39min cooling in HD condition. In both conditions, the ventilation fans greatly enhanced the evaporative heat loss compared with Fan-off. The hybrid PCS (i.e., PCM+Fan-on) provided a continuous cooling effect during the three-hour test and the average cooling rate for the whole body was around 111 and 315W in HH and HD conditions, respectively. Overall, the new hybrid PCS may be an effective means of ameliorating symptoms of heat stress in both hot-humid and hot-dry environments.


Textile Research Journal | 2013

The torso cooling of vests incorporated with phase change materials: a sweat evaporation perspective

Mengmeng Zhao; Chuansi Gao; Faming Wang; Kalev Kuklane; Ingvar Holmér; Jun Li

Cooling vests incorporated with phase change materials (PCMs) add extra insulation and restrict sweat evaporation. It is still unclear how much cooling benefit they can provide. The aim of this study was to investigate the torso cooling of the PCM vests in two hot environments: hot humid (HH, 34°C, 75% relative humidity (RH)) and hot dry (HD, 34°C, 37% RH). A pre-wetted torso fabric skin was used to simulate torso sweating on a thermal manikin. Three cooling vests incorporated with three melting temperatures (Tm) of PCMs were tested (Tm = 21°C, Tm = 24°C and Tm = 28°C). They were worn under a military ensemble (total thermal insulation 1.60 clo; evaporative resistance 0.0516 kPaċm2/W), respectively. In a HH environment all the three cooling vests provided effective torso cooling; in a HD environment the cooling benefit was negative. In both environmental conditions, the evaporative cooling was greatly restricted by the cooling vests. The study indicated that when wearing the protective clothing with the relatively low evaporative resistance and when sweat production was high, the cooling vests were effective in a HH environment, but not in a HD environment.

Collaboration


Dive into the Chuansi Gao's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Faming Wang

Hong Kong Polytechnic University

View shared research outputs
Top Co-Authors

Avatar

Ingvar Holmér

Gymnastik- och idrottshögskolan

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge