IEEE Transactions on Nuclear Science | 2002

Postinjection single photon transmission tomography with ordered-subset algorithms for whole-body PET imaging

Chuanyong Bai; Paul E. Kinahan; David Brasse; Claude Comtat; David W. Townsend

We have evaluated the penalized ordered-subset transmission reconstruction (OSTR) algorithm for postinjection single photon transmission scanning. The OSTR algorithm of Erdogan and Fessler (1999) uses a more accurate model for transmission tomography than ordered-subsets expectation-maximization (OSEM) when OSEM is applied to the logarithm of the transmission data. The OSTR algorithm is directly applicable to postinjection transmission scanning with a single photon source, as emission contamination from the patient mimics the effect, in the original derivation of OSTR, of random coincidence contamination in a positron source transmission scan. Multiple noise realizations of simulated postinjection transmission data were reconstructed using OSTR, filtered backprojection (FBP), and OSEM algorithms. Due to the nonspecific task performance, or multiple uses, of the transmission image, multiple figures of merit were evaluated, including image noise, contrast, uniformity, and root mean square (rms) error. We show that: 1) the use of a three-dimensional (3-D) regularizing image roughness penalty with OSTR improves the tradeoffs in noise, contrast, and rms error relative to the use of a two-dimensional penalty; 2) OSTR with a 3-D penalty has improved tradeoffs in noise, contrast, and rms error relative to FBP or OSEM; and 3) the use of image standard deviation from a single realization to estimate the true noise can be misleading in the case of OSEM. We conclude that using OSTR with a 3-D penalty potentially allows for shorter postinjection transmission scans in single photon transmission tomography in positron emission tomography (PET) relative to FBP or OSEM reconstructed images with the same noise properties. This combination of singles+OSTR is particularly suitable for whole-body PET oncology imaging.


ieee nuclear science symposium | 2003

CT-based attenuation correction in PET image reconstruction for the Gemini system

Chuanyong Bai; Chi-Hua Tung; Jeffrey A. Kolthammer; Ling Shao; Kevin M. Brown; Zuo Zhao; A.J. Da Silva; Jinghan Ye; Daniel Gagnon; M. J. Parma; E. S. Walsh

The Gemini system is a combined CT/PET imaging system newly developed by Philips Medical Systems. It has a unique open gantry design that allows for variable separation between the CT and PET gantries. The Gemini system incorporates CT-based attenuation correction (CT-AC) into a three-dimensional row-action maximum likelihood algorithm (RAMLA) for PET image reconstruction. It uses several unique techniques to achieve high accuracy while reducing patient X-ray dose. These new techniques include (1) using low-dose CT protocols to obtain CT images with adequate quality and quantitation for CT-AC while keeping patient X-ray dose low; (2) using a CT truncation compensation technique to improve the accuracy of CT-AC; and (3) using a generalized model for the conversion of CT images to attenuation maps at 511 keV. In this paper, we report the workflow and performance of Gemini CT-AC using phantom and patient studies. For comparison, attenuation maps obtained from PET transmission scans are also used for attenuation correction (TX-AC). Both phantom and patient studies show that PET images with CT-AC have image quality equivalent to or better than those with TX- AC.


IEEE Transactions on Nuclear Science | 2003

The effects of center of rotation errors on cardiac SPECT imaging

Chuanyong Bai; Ling Shao; Jinghan Ye; Mary K. Durbin

In SPECT imaging, center of rotation (COR) errors lead to the misalignment of projection data and can potentially degrade the quality of the reconstructed images. In this work, we study the effects of COR errors on cardiac SPECT imaging using simulation, point source, cardiac phantom, and patient studies. For simulation studies, we generate projection data using a uniform MCAT phantom first without modeling any physical effects (NPH), then with the modeling of detector response effect (DR) alone. We then corrupt the projection data with simulated sinusoid and step COR errors. For other studies, we introduce sinusoid COR errors to projection data acquired on SPECT systems. An OSEM algorithm is used for image reconstruction without detector response correction, but with nonuniform attenuation correction when needed. The simulation studies show that, when COR errors increase from 0 to 0.96 cm: 1) sinusoid COR errors in axial direction lead to intensity decrease in the inferoapical region; 2) step COR errors in axial direction lead to intensity decrease in the distal anterior region. The intensity decrease is more severe in images reconstructed from projection data with NPH than with DR; and 3) the effects of COR errors in transaxial direction seem to be insignificant. In other studies, COR errors slightly degrade point source resolution; COR errors of 0.64 cm or above introduce visible but insignificant nonuniformity in the images of uniform cardiac phantom; COR errors up to 0.96 cm in transaxial direction affect the lesion-to-background contrast (LBC) insignificantly in the images of cardiac phantom with defects, and COR errors up to 0.64 cm in axial direction only slightly decrease the LBC. For the patient studies with COR errors up to 0.96 cm, images have the same diagnostic/prognostic values as those without COR errors. This work suggests that COR errors of up to 0.64 cm are not likely to change the clinical applications of cardiac SPECT imaging when using iterative reconstruction algorithm without detector response correction.


ieee nuclear science symposium | 2001

Study of the effect of statistical fluctuations on defect detectability at clinical count levels in cardiac SPECT

Mary K. Durbin; Chuanyong Bai; Jinghan Ye; Zuo Zhao; A.J. Da Silva; Ling Shao

Cardiac SPECT using Tl-201 suffers from low count statistics. Any statistical studies concerning the evaluation of a reconstruction algorithm, acquisition parameters, diagnostic confidence, etc., for clinical applications are impacted by the difficulty of obtaining data with multiple noise realizations. For this work, we acquired list-mode data of a Tl-201 cardiac phantom with very high counts in three configurations-with an anterior defect, an inferior defect, and no defect. The list-mode data were repartitioned to obtain statistically independent multiple data sets all with the same, clinically relevant noise level. Images were reconstructed from each of the resulting data sets using an iterative algorithm with attenuation correction. Reconstructed images were examined by four human observers, as well as analyzed quantitatively. The ability of observers to differentiate between normal scans and scans with defects varied substantially among datasets. There was correlation between the measured defect detectability and the visual assessment. The fact that the visibility of defects and the uniformity of normal scans varied significantly from one data set to the next, even when both were acquired at the same time, under identical conditions, indicates that the low statistics levels at clinical doses can have a measurable effect on diagnostic confidence.


ieee nuclear science symposium | 2003

Hybrid parallel-slant hole collimators for SPECT imaging

Chuanyong Bai; Ling Shao; Jinghan Ye; Mary K. Durbin; Mike Petrillo

We propose a new collimator geometry, the hybrid parallel-slant hole geometry (HPS), to improve sensitivity for SPECT imaging with large field of view (LFOV) gamma cameras. A HPS collimator has one segment with parallel holes and one or more segments with slant holes. The collimator can be mounted on a conventional SPECT LFOV system that uses parallel-beam collimators, and no additional detector or collimator motion is required for data acquisition. The parallel segment of the collimator allows for the acquisition of a complete data set of the organs-of-interest and the slant segments provide additional data. In this work, simulation studies of an MCAT phantom were performed with an HPS collimator with one slant segment. The slant direction points from patient head to patient feet with a slant angle of 30/spl deg/. We simulated 64 projection views over 180/spl deg/, and we modeled nonuniform attenuation effect. Images were reconstructed using an OSEM algorithm that incorporated the hybrid geometry. Sensitivity to the cardiac region of the phantom was increased by approximately 50% when using the HPS collimator compared with a parallel-hole collimator. No visible artifacts were observed in the reconstructed images and the signal-to- noise ratio (SNR) of the cardiac walls was improved. Compared with collimators with other geometries, using a HPS collimator has the following advantages: (a) significant sensitivity increase, (b) a complete data set obtained from the parallel segment that allows for artifact-free image reconstruction, and (c) no additional collimator or detector motion. This work demonstrates the potential value of hybrid geometry in collimator design for LFOV SPECT imaging.


ieee nuclear science symposium | 2002

The effects of center of rotation errors on SPECT imaging

Chuanyong Bai; Ling Shao; Jinghan Ye; Mary K. Durbin

In SPECT imaging, center of rotation (COR) errors lead to the misalignment of the projection data and can potentially degrade the quality of the reconstructed images. In this work, we study the effects of COR errors on the quality and clinical applications of SPECT images using point source, cardiac phantom, and patient studies. COR errors are simulated in both axial and transaxial directions in the projection data. The reconstructed images are evaluated in terms of point source resolution, image uniformity and lesion-to-background contrast (LBC) in cardiac phantom images, and clinical applications for patient images. It is shown that point source resolution degrades as COR errors increase. Using LEHR collimators. the full-width at half-maximum (FWHM) increases by less than 25% when the COR error increases from 0 to 0.96 cm. COR error of 0.64 cm or larger introduces visible but insignificant nonuniformity to the images of a uniform cardiac phantom. Increase of COR errors from 0 to 0.96 cm can decrease the LBC in the images of an abnormal cardiac phantom by as much as 20%, depending on the direction of COR errors and defect size. For the patient studies with COR errors up to 0.96 cm, images have the same diagnostic/prognostic values as those without COR errors. As a conclusion, for the limit number (n=4) of patient studies, COR errors of up to 0.96 cm are not likely to change the clinical applications of cardiac SPECT images.


ieee nuclear science symposium | 2002

A generalized model for the conversion from CT numbers to linear attenuation coefficients

Chuanyong Bai; Ling Shao; A.J. Da Silva; Zuo Zhao


Archive | 2002

Non-invasive plaque detection using combined nuclear medicine and x-ray system

Lingxiong Shao; Chuanyong Bai; Mary K. Durbin


Archive | 2003

Combined nuclear medicine and x-ray system

Lingxiong Shao; Chuanyong Bai; Mary K. Durbin


Archive | 2003

Combined nuclear medicine and röngtensystem

Lingxiong Shao; Chuanyong Bai; Mary K. Durbin