Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Chun Xiang Tang is active.

Publication


Featured researches published by Chun Xiang Tang.


European Journal of Radiology | 2013

Dual-energy CT based vascular iodine analysis improves sensitivity for peripheral pulmonary artery thrombus detection: An experimental study in canines

Chun Xiang Tang; Long Jiang Zhang; Zong Hong Han; Chang Sheng Zhou; Aleksander W. Krazinski; Justin R. Silverman; U. Joseph Schoepf; Guang Ming Lu

PURPOSE To evaluate the performance of dual-energy CT (DECT) based vascular iodine analysis for the detection of acute peripheral pulmonary thrombus (PE) in a canine model with histopathological findings as the reference standard. MATERIALS AND METHODS The study protocol was approved by our institutional animal committee. Thrombi (n = 12) or saline (n = 4) were intravenously injected via right femoral vein in sixteen dogs, respectively. CT pulmonary angiography (CTPA) in DECT mode was performed and conventional CTPA images and DECT based vascular iodine studies using Lung Vessels application were reconstructed. Two radiologists visually evaluated the number and location of PEs using conventional CTPA and DECT series on a per-animal and a per-clot basis. Detailed histopathological examination of lung specimens and catheter angiography served as reference standard. Sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of DECT and CTPA were calculated on a segmental and subsegmental or more distal pulmonary artery basis. Weighted κ values were computed to evaluate inter-modality and inter-reader agreement. RESULTS Thirteen dogs were enrolled for final image analysis (experimental group = 9, control group = 4). Histopathological results revealed 237 emboli in 45 lung lobes in 9 experimental dogs, 11 emboli in segmental pulmonary arteries, 49 in subsegmental pulmonary arteries, 177 in fifth-order or more distal pulmonary arteries. Overall sensitivity, specificity, accuracy, PPV, and NPV for CTPA plus DECT were 93.1%, 76.9%, 87.8%, 89.4%, and 84.2% for the detection of pulmonary emboli. With CTPA versus DECT, sensitivities, specificities, accuracies, PPVs, and NPVs are all 100% for the detection of pulmonary emboli on a segmental pulmonary artery basis, 88.9%, 100%, 96.0%, 100%, and 94.1% for CTPA and 90.4%, 93.0%, 92.0%, 88.7%, and 94.1% for DECT on a subsegmental pulmonary artery basis; 23.8%, 96.4%, 50.4%, 93.5%, and 36.7% for CTPA and 95.9%, 75.5%, 88.2%, 86.5%, and 91.9% on a sub-subsegmental and more distal pulmonary artery basis, respectively. Good inter-modality (κ = 0.65, P<0.001) and inter-reader (κ = 0.70, P<0.001) agreement were observed. CONCLUSION With histopathological findings as the reference standard, DECT based vascular iodine analysis improves the sensitivity for detecting peripheral PE compared with CTPA, albeit at the price of decreased specificity and PPV.


International Journal of Cardiology | 2013

Diagnostic accuracy of three-dimensional contrast-enhanced MR angiography at 3-T for acute pulmonary embolism detection: Comparison with multidetector CT angiography☆

Long Jiang Zhang; Song Luo; Benjamin M. Yeh; Chang Sheng Zhou; Chun Xiang Tang; Yan-E Zhao; Lin li; Ling Zheng; Wei Huang; Guang Ming Lu

BACKGROUND Three-dimensional contrast-enhanced MR pulmonary angiography (MRPA) is a suitable option for pulmonary embolism (PE) detection. However, there have been few reports on the diagnostic accuracy of MRPA for PE detection in a 3-T MR system. The purpose of this study was to evaluate the accuracy of MRPA in a 3-T MR system to detect acute PE with multidetector CT pulmonary angiography (CTPA) as reference standard. METHODS Twenty-seven patients (18 males and 9 females, mean age 38.9±14.4 years) underwent both MRPA and CTPA within 3 days (range, 0-3 days) for evaluating PE. Pulmonary emboli in MRPA were independently analyzed on a per-patient and per-lobe basis by two radiologists. CTPA was regarded as reference standard, which was evaluated by another two radiologists in consensus. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for PE detection were calculated. Weighted κ values were calculated to evaluate agreement between readers. RESULTS Twenty-four patients had PE in 55 lung lobes in CTPA, while 3 patients had no PE detected. Readers 1 and 2 correctly detected 47 and 46 lung lobes having clots in 24 and 23 patients, corresponding to sensitivities, specificities, PPV, NPV, and accuracies of 100%, 100%, 100%, 100%, 100%; 100%, 66.7%, 96.0%, 100%, 96.4% on a per-patient basis and 85.5%, 100%, 100%, 90.9%, 94.1%; 83.6%, 93.7%, 90.2%, 89.2%, 89.6% on a per-lobe basis; respectively. Excellent inter-reader agreement (κ values=1.00 and 0.934; both P<0.001) were found for detecting PE on a per-patient and per-lobe analysis. CONCLUSION Three-dimensional contrast-enhanced MRPA with a 3-T MR system is a suitable alternative modality to CTPA to detect PE on a per-patient basis based on this small cohort study.


Academic Radiology | 2015

Seventy-Peak Kilovoltage High-Pitch Thoracic Aortic CT Angiography without ECG Gating: Evaluation of Image Quality and Radiation Dose.

Long Jiang Zhang; Yan E. Zhao; U. Joseph Schoepf; Stefanie Mangold; Lloyd M. Felmly; Xie Li; Chun Xiang Tang; Chang Sheng Zhou; Li Qi; Guang Ming Lu

RATIONALE AND OBJECTIVES To assess the feasibility of 70-kVp high-pitch non-ECG-gated thoracic aortic computed tomography angiography (CTA) with 40-mL contrast agent compared to 100-kVp standard-pitch CTA with 60-mL contrast agent. MATERIALS AND METHODS Sixty-seven patients (51 men and 16 women; mean age, 55 ± 14 years) received non-ECG-gated aortic CTA at 70 kVp, high pitch of 3.4, and 40-mL contrast agent (group A, n = 31) or CTA at 100-kVp, pitch of 1.2, and 60-mL contrast agent (group B, n = 36). Iterative reconstruction was used in all patients. For image quality assessment, CTA images were evaluated on a three-point scale and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated and compared. Furthermore, computed tomography (CT) dose index was recorded. RESULTS Mean CT values and noise levels were higher in group A compared to group B (all P < .001), whereas SNR and CNR were lower than those in group B (all P < .001). Furthermore, the image quality of the aorta at the level of the diaphragm was lower in group A than that in group B (P < .05). However, image quality was graded as diagnostic in all patients, and motion artifacts of the aortic arch were significantly decreased in group A (P <.05). Interreader agreement was good or excellent for image quality assessment (k = 0.625-0.835). The 70-kVp CTA protocol, which allows dose reduction of 85%, was considered diagnostic in all instances by two readers. CONCLUSIONS Our proposed thoracic aortic CTA protocol provides diagnostic information with substantial reduction of both radiation and contrast agent doses compared to standard-pitch CTA at 100 kVp.


Pediatric Radiology | 2015

Multidetector computed tomography pulmonary angiography in childhood acute pulmonary embolism

Chun Xiang Tang; U. Joseph Schoepf; Shahryar M. Chowdhury; Mary A. Fox; Long Jiang Zhang; Guang Ming Lu

Pulmonary embolism is a life-threatening condition affecting people of all ages. Multidetector row CT pulmonary angiography has improved the imaging of pulmonary embolism in both adults and children and is now regarded as the routine modality for detection of pulmonary embolism. Advanced CT pulmonary angiography techniques developed in recent years, such as dual-energy CT, have been applied as a one-stop modality for pulmonary embolism diagnosis in children, as they can simultaneously provide anatomical and functional information. We discuss CT pulmonary angiography techniques, common and uncommon findings of pulmonary embolism in both conventional and dual-energy CT pulmonary angiography, and radiation dose considerations.


Acta Radiologica | 2013

Three-dimensional contrast-enhanced magnetic resonance venography for detection of renal vein thrombosis: comparison with multidetector CT venography

Long Jiang Zhang; Xinsheng Wu; Gui Fen Yang; Chun Xiang Tang; Song Luo; Chang Sheng Zhou; Xue Man Ji; Guang Ming Lu

Background Renal vein thrombosis is not uncommon, however, there have been few reports on the diagnostic accuracy of three-dimensional contrast-enhanced magnetic resonance venography (3D-CE-MRV) in the detection of renal vein thrombosis (RVT). Purpose To evaluate the value of 3D-CE-MRV for detecting RVT with multidetector computed tomography (CT) venography as reference standard. Material and Methods Thirty-two patients with nephrotic syndrome underwent renal CT venography and gradient echo pulse sequence (FLASH 3D) 3D-CE-MRV in a clinical 3-T whole-body MR scanner for suspected RVT with time interval of 0–5 days. RVT was recorded on a per-patient and per-vessel (left renal vein, right renal vein, and inferior vena cava) basis. The diagnostic accuracy of 3D-CE-MRV for detection of RVT was calculated with CT venography as reference standard. Inter-reader agreement for RVT detection was evaluated using Kappa statistics. Results Of 32 patients, CT venography detected 22 vessels with thrombosis in 17 patients, including five in right renal veins, 14 in left renal veins, and three in inferior vena cava, while 15 patients had no RVT. 3D-CE-MRV detected 21 vessels (21/96, 21.9%) with thrombosis in 16 patients (6/32, 50%), including five in right renal veins, 13 in left renal veins, and three in inferior vena cava, while 16 patients (16/32, 50%) had no RVT. With CT venography as reference standard, the sensitivities and specificities of 3D-CE-MRV for RVT detection were 94.1%, 100%; 95.5%, 100% on a per-patient and a per-vessel basis, respectively. Excellent inter-reader agreement (Kappa value = 0.969, P < 0.001) was observed for RVT detection. Conclusion 3D-CE-MRV has a high diagnostic accuracy in the detection of RVT, which is optimal alternative imaging modality in the detection of RVT.


European Journal of Radiology | 2016

Chronic thromboembolic pulmonary hypertension: Comparison of dual-energy computed tomography and single photon emission computed tomography in canines

Chun Xiang Tang; Gui Fen Yang; U. Joseph Schoepf; Zong Hong Han; Li Qi; Yan E. Zhao; Jiang Wu; Chang Sheng Zhou; Hong Zhu; Andrew C. Stubenrauch; Stefanie Mangold; Long Jiang Zhang; Guang Ming Lu

PURPOSE To compare diagnostic accuracy between dual-energy CT lung perfused blood volume (Lung PBV) imaging and single photon emission computed tomography (SPECT) in detecting chronic thromboembolic pulmonary hypertension (CTEPH) with histopathological results as reference standard in a canine model. MATERIALS AND METHODS Eighteen CTEPH canines were included into this experimental study. All procedures including paracentesis, embolization, scanning, pressure measurement and feeding medicine were repeated each two weeks, until systolic/diastolic pressure in canines was ≥ 30/15 mm Hg or mean pulmonary artery pressure ≥ 20 mm Hg, and then sacrificed for histopathology examination. Two radiologists (readers 1 and 2) and two nuclear radiologists (readers 3 and 4) analyzed images of conventional CT pulmonary angiography in dual-energy CT mode, Lung PBV imaging and SPECT, respectively. The presence, numbers, and locations of pulmonary emboli (PE) were recorded on a per-lobe basis. Pathological examination was served as reference standard. Sensitivity, specificity and accuracy of Lung PBV and SPECT were calculated. Kappa statistics were used to quantify inter-reader agreement. RESULTS With histopathological results as reference standard, the sensitivities of 72.2%, 78.8%, 81.2%, specificities of 75.9%, 87.5%, 84.8%, accuracies of 73.8%, 83.1%, 83.1%, for readers 1, 2 and both with Lung PBV, respectively. Readers 3, 4 and both had sensitivities of 14.3%, 25.7%, 33.3%, specificities of 90.0%, 86.7%, 93.3%, accuracies of 49.2%, 53.8%, 60.0% with SPECT for detecting CTEPH. Inter-reader agreements were good for dual-energy CT (kappa=0.662) and SPECT (k=0.706) for detecting CTEPH. CONCLUSION Dual-energy CT had a higher accuracy to detect CTEPH than SPECT in this canine model study.


Scientific Reports | 2016

Single Phase Dual-energy CT Angiography: One-stop-shop Tool for Evaluating Aneurysmal Subarachnoid Hemorrhage

Qian Qian Ni; Chun Xiang Tang; Yan E. Zhao; Chang Sheng Zhou; Guo Zhong Chen; Guang Ming Lu; Long Jiang Zhang

Aneurysmal subarachnoid hemorrhages have extremely high case fatality in clinic. Early and rapid identifications of ruptured intracranial aneurysms seem to be especially important. Here we evaluate clinical value of single phase contrast-enhanced dual-energy CT angiograph (DE-CTA) as a one-stop-shop tool in detecting aneurysmal subarachnoid hemorrhage. One hundred and five patients who underwent true non-enhanced CT (TNCT), contrast-enhanced DE-CTA and digital subtraction angiography (DSA) were included. Image quality and detectability of intracranial hemorrhage were evaluated and compared between virtual non-enhanced CT (VNCT) images reconstructed from DE-CTA and TNCT. There was no statistical difference in image quality (P > 0.05) between VNCT and TNCT. The agreement of VNCT and TNCT in detecting intracranial hemorrhage reached 98.1% on a per-patient basis. With DSA as reference standard, sensitivity and specificity on a per-patient were 98.3% and 97.9% for DE-CTA in intracranial aneurysm detection. Effective dose of DE-CTA was reduced by 75.0% compared to conventional digital subtraction CTA. Thus, single phase contrast-enhanced DE-CTA is optimal reliable one-stop-shop tool for detecting intracranial hemorrhage with VNCT and intracranial aneurysms with DE-CTA with substantial radiation dose reduction compared with conventional digital subtraction CTA.


Journal of Blood Disorders and Transfusion | 2014

The Rupture of Isolated Spontaneous Celiac Artery Dissection with Pseudoaneurysm: Report of a Case

Chun Xiang Tang; Chang Sheng Zhou; Long Jiang Zhang; Guang Ming Lu

Isolated spontaneous dissection of visceral artery without associated aortic dissection is rare, although more cases have recently been reported because of the rapid advancement of diagnostic imaging techniques. Complications are ischemia, aneurysm formation and rupture. We present a case with rupture of isolated dissection of the celiac artery with pseudoaneurysm formation. The patient was a 54-year-old male smoker without any recorded medical history, who underwent sonography, multidetector CT angiography (CTA), contrast-enhanced MR angiography (CE-MRA), and DSA. The final diagnosis was rupture of isolated celiac artery dissection with the formation of pseudoaneurysm. Resection of the pseudoaneurysm was performed. The postoperative course was uneventful except for biliary fistula resulting from ischemia and necrosis of compressed common bile duct. The patient was in good condition in follow-up. This case indicated noninvasive CTA and MRA had an important role in the detection and follow-up of celiac artery dissection and its complications.


Trends in Cardiovascular Medicine | 2018

Cardiovascular magnetic resonance imaging for amyloidosis: The state-of-the-art

Chun Xiang Tang; Steffen E. Petersen; Mihir M. Sanghvi; Guang Ming Lu; Long Jiang Zhang

Amyloidosis results from insoluble precursor proteins being deposited in the extracellular compartment. The prognosis of the disease is predominantly determined by cardiac involvement due to amyloid accumulation that contributes to cardiac dysfunction and disturbed conduction of cardiac electrical signals. The clinical and radiological manifestations of amyloidosis are often non-specific, making amyloidosis a diagnostic challenge both for clinicians and radiologists. Cardiovascular magnetic resonance imaging, including conventional sequences, late gadolinium enhancement, T1 mapping and determination of extracellular volume fraction is a multi-dimensional modality for the assessment and diagnosis of cardiac amyloidosis and, in addition, is an excellent tool for risk stratification and disease tracking.


European Radiology | 2014

Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience

Long Jiang Zhang; Li Qi; Jing Wang; Chun Xiang Tang; Chang Sheng Zhou; Xue Man Ji; James V. Spearman; Carlo N. De Cecco; Felix G. Meinel; U. Joseph Schoepf; Guang Ming Lu

Collaboration


Dive into the Chun Xiang Tang's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

U. Joseph Schoepf

Medical University of South Carolina

View shared research outputs
Top Co-Authors

Avatar

Li Qi

Nanjing University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Stefanie Mangold

Medical University of South Carolina

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge