Claire M. Brown
McGill University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Claire M. Brown.
Journal of Cell Biology | 2006
Anjana Nayal; Donna J. Webb; Claire M. Brown; Erik Schaefer; Miguel Vicente-Manzanares; Alan Rick Horwitz
Continuous adhesion formation and disassembly (adhesion turnover) in the protrusions of migrating cells is regulated by unclear mechanisms. We show that p21-activated kinase (PAK)–induced phosphorylation of serine 273 in paxillin is a critical regulator of this turnover. Paxillin-S273 phosphorylation dramatically increases migration, protrusion, and adhesion turnover by increasing paxillin–GIT1 binding and promoting the localization of a GIT1–PIX–PAK signaling module near the leading edge. Mutants that interfere with the formation of this ternary module abrogate the effects of paxillin-S273 phosphorylation. PAK-dependent paxillin-S273 phosphorylation functions in a positive-feedback loop, as active PAK, active Rac, and myosin II activity are all downstream effectors of this turnover pathway. Finally, our studies led us to identify in highly motile cells a class of small adhesions that reside near the leading edge, turnover in 20–30 s, and resemble those seen with paxillin-S273 phosphorylation. These adhesions appear to be regulated by the GIT1–PIX–PAK module near the leading edge.
Journal of Cell Science | 2009
Melanie M. Frigault; Judith Lacoste; Jody L. Swift; Claire M. Brown
Imaging of living cells and tissue is now common in many fields of the life and physical sciences, and is instrumental in revealing a great deal about cellular dynamics and function. It is crucial when performing such experiments that cell viability is at the forefront of any measurement to ensure that the physiological and biological processes that are under investigation are not altered in any way. Many cells and tissues are not normally exposed to light during their life cycle, so it is important for microscopy applications to minimize light exposure, which can cause phototoxicity. To ensure minimal light exposure, it is crucial that microscope systems are optimized to collect as much light as possible. This can be achieved using superior-quality optical components and state-of-the-art detectors. This Commentary discusses how to set up a suitable environment on the microscope stage to maintain living cells. There is also a focus on general and imaging-platform-specific ways to optimize the efficiency of light throughput and detection. With an efficient optical microscope and a good detector, the light exposure can be minimized during live-cell imaging, thus minimizing phototoxicity and maintaining cell viability. Brief suggestions for useful microscope accessories as well as available fluorescence tools are also presented. Finally, a flow chart is provided to assist readers in choosing the appropriate imaging platform for their experimental systems.
Journal of Cell Science | 2006
Claire M. Brown; Benedict Hebert; David L. Kolin; Jessica Zareno; Leanna Whitmore; Alan Rick Horwitz; Paul W. Wiseman
Cell migration is regulated in part by the connection between the substratum and the actin cytoskeleton. However, the very large number of proteins involved in this linkage and their complex network of interactions make it difficult to assess their role in cell migration. We apply a novel image analysis tool, spatio-temporal image correlation spectroscopy (STICS), to quantify the directed movements of adhesion-related proteins and actin in protrusions of migrating cells. The STICS technique reveals protein dynamics even when protein densities are very low or very high, and works in the presence of large, static molecular complexes. Detailed protein velocity maps for actin and the adhesion-related proteins α-actinin, α5-integrin, talin, paxillin, vinculin and focal adhesion kinase are presented. The data show that there are differences in the efficiency of the linkage between integrin and actin among different cell types and on the same cell type grown on different substrate densities. We identify potential mechanisms that regulate efficiency of the linkage, or clutch, and identify two likely points of disconnect, one at the integrin and the other at α-actinin or actin. The data suggests that the efficiency of the linkage increases as actin and adhesions become more organized showing the importance of factors that regulate the efficiency in adhesion signaling and dynamics.
Nature Protocols | 2011
Richard W. Cole; Tushare Jinadasa; Claire M. Brown
This protocol outlines a procedure for collecting and analyzing point spread functions (PSFs). It describes how to prepare fluorescent microsphere samples, set up a confocal microscope to properly collect 3D confocal image data of the microspheres and perform PSF measurements. The analysis of the PSF is used to determine the resolution of the microscope and to identify any problems with the quality of the microscopes images. The PSF geometry is used as an indicator to identify problems with the objective lens, confocal laser scanning components and other relay optics. Identification of possible causes of PSF abnormalities and solutions to improve microscope performance are provided. The microsphere sample preparation requires 2–3 h plus an overnight drying period. The microscope setup requires 2 h (1 h for laser warm up), whereas collecting and analyzing the PSF images require an additional 2–3 h.
Nature Protocols | 2013
Joshua A. Broussard; Benjamin Rappaz; Donna J. Webb; Claire M. Brown
This protocol describes procedures for performing fluorescence resonance energy transfer (FRET) microscopy analysis by three different methods: acceptor photobleaching, sensitized emission and spectral imaging. We also discuss anisotropy and fluorescence lifetime imaging microscopy–based FRET techniques. By using the specific example of the FRET probe Akind (Akt indicator), which is a version of Akt modified such that FRET occurs when the probe is activated by phosphorylation, indicating Akt activation. The protocol provides a detailed step-by-step description of sample preparation, image acquisition and analysis, including control samples, image corrections and the generation of quantitative FRET/CFP ratio images for both sensitized emission and spectral imaging. The sample preparation takes 2 d, equipment setup takes 2–3 h and image acquisition and analysis take 6–8 h.
Cell Reports | 2015
Hugues Petitjean; Sophie Anne Pawlowski; Steven Li Fraine; Behrang Sharif; Doulia Hamad; Tarheen Fatima; Jim Berg; Claire M. Brown; Lily-Yeh Jan; Alfredo Ribeiro-da-Silva; João M. Bráz; Allan I. Basbaum; Reza Sharif-Naeini
SUMMARY Neuropathic pain is a chronic debilitating disease that results from nerve damage, persists long after the injury has subsided, and is characterized by spontaneous pain and mechanical hypersensitivity. Although loss of inhibitory tone in the dorsal horn of the spinal cord is a major contributor to neuropathic pain, the molecular and cellular mechanisms underlying this disinhibition are unclear. Here, we combined pharmacogenetic activation and selective ablation approaches in mice to define the contribution of spinal cord parvalbumin (PV)-expressing inhibitory interneurons in naive and neuropathic pain conditions. Ablating PV neurons in naive mice produce neuropathic pain-like mechanical allodynia via disinhibition of PKCγ excitatory interneurons. Conversely, activating PV neurons in nerve-injured mice alleviates mechanical hypersensitivity. These findings indicate that PV interneurons are modality-specific filters that gate mechanical but not thermal inputs to the dorsal horn and that increasing PV inter-neuron activity can ameliorate the mechanical hypersensitivity that develops following nerve injury.
Journal of Cell Science | 2007
Claire M. Brown
The advent of fluorescent proteins and the continued development of novel fluorescent probes have put fluorescence microscopy at the center of life science research. Fluorescence microscopes range from relatively straight-forward wide-field microscopes to highly specialised spectral-imaging confocal
Faraday Discussions | 1999
Nils O. Petersen; Claire M. Brown; Anna Kaminski; Jonathan V. Rocheleau; Mamta Srivastava; Paul W. Wiseman
Communication between cells invariably involves interactions of a signalling molecule with a receptor at the surface of the cell. Typically, the receptor is imbedded in the membrane and it is hypothesized that the binding of the signalling molecule causes a change in the state of aggregation of the receptor which, in turn, initiates a biochemical signal within the cell. Subsequently, many of the occupied receptors bind to membrane-associated structures, called coated pits, which invaginate and pinch off to form coated vesicles, thereby removing the receptors from the cell surface. The state of aggregation of membrane receptors is obviously in constant flux. Any useful approach to measuring the state of aggregation must, therefore, allow for dynamic measurements in living cells. It is possible to use fluorescently labelled signalling molecules or antibodies directed at the receptor of interest to visualize the receptor on the cell surface with a fluorescence microscope. By employing a laser confocal microscope, high resolution images can be produced in which the fluorescence intensity is quantitatively imaged as a function of position across the surface of the cell. Calculations of autocorrelation functions of these images provide direct and accurate measures of the density of fluorescent particles on the surface. Combined with the average intensity in the image, which reflects the total average number of molecules, it is possible to estimate the degree of aggregation of the receptor molecules. We refer to this analysis as image correlation spectroscopy (ICS). We show how ICS can be used to measure the density of several receptors on a variety of cells and how it can be used to measure the density of coated pits and the number of molecules per coated pit. We also show how the technique can be used to monitor fusion of virus particles to cell membranes. Further, we illustrate that, by calculating cross-correlation functions between pairs of images, we can extend the analysis to measurements of the distributions as a function of time, on the second timescale, as well as to measurements of the movement of the receptor aggregates on the surface. Finally, we illustrate that, by this approach, we can measure the extent of interaction between two different receptors as a function of time. This represents the most quantitative measurement of the extent of co-localization of receptors available and is independent of the spatial resolution of the confocal microscope. The theory of ICS and image cross-correlation spectroscopy (ICCS), focussing on the interpretation of the data in terms of the biological phenomenon being probed, is discussed.
Science Signaling | 2008
Mohamed Kodiha; Claire M. Brown; Ursula Stochaj
High-throughput screening and MetaXpress software modules can be adapted to quantify the subcellular localization of fluorescently labeled molecules. Intracellular signaling and cell-to-cell communication depend on the coordination of numerous signaling events, and this large flow of information has to be properly organized in space and time. Common and critical to all of these processes and the ultimate cellular response is the correct spatial distribution of signaling components and their targets. This fundamental concept applies to a large number of signaling processes. It is frequently important to quantify the localization of signaling molecules within different cellular compartments to detect subtle changes or to define threshold levels of signaling molecules in a certain location that are necessary to trigger subsequent events. Of particular importance is the separation of nuclear and cytoplasmic events, and sensitive methods are required to measure their contribution to signal transduction. Procedures described here allow the quantification of fluorescence signals located in the nucleus, cytoplasm, or at the nuclear envelope. The methods rely on high-throughput imaging equipment, confocal microscopy, and software modules that measure the fluorescence intensity in the compartment of interest. We discuss the rationale for selecting the appropriate equipment for image acquisition and the proper software modules to quantify fluorescence in distinct cellular compartments. Initially, high-throughput technology for high-speed image acquisition was developed for multiwell plates. We adapted high-throughput technology for image acquisition for cells grown on cover slips. Images of higher spatial resolution along the z axis were acquired by confocal microscopy. For subsequent analyses, the choice of appropriate software modules is critical for rapid and reliable quantification of fluorescence intensities.
Molecular Biology of the Cell | 2012
Joshua A. Broussard; Wan Hsin Lin; Devi Majumdar; Bridget Anderson; Brady Eason; Claire M. Brown; Donna J. Webb
The adaptor protein APPL1 regulates cell migration and adhesion dynamics by inhibiting the activity of the serine/threonine kinase Akt at the cell edge and within adhesions. In addition, APPL1 significantly decreases the tyrosine phosphorylation of Akt by the nonreceptor tyrosine kinase Src, which is critical for Akt-mediated cell migration.