Claudio Hadid
Argerich Hospital
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Claudio Hadid.
Pacing and Clinical Electrophysiology | 2008
Carlos Labadet; Darío Di Toro; Claudio Hadid
A 28-year-old man with a history of palpita-tionswasreferredforevaluation.Initialevaluationshowed a normal resting electrocardiogram withsinus rhythm and absence of structural heart dis-ease.AmbulatoryHoltermonitoringdemonstratedseveral episodes of self-terminated narrow QRScomplex tachycardia, as well as episodes of atri-oventricular (AV) block (Fig. 1).
Arquivos Brasileiros De Cardiologia | 2008
Claudio Hadid; Patricia Avellana; Darío Di Toro; Claudia Fernández Gomez; Miguel Visser; Noemí Prieto
BACKGROUND Recent MADIT II and SCD-HeFT trials have led to an expansion of indications for use of prophylactic Implantable Cardioverter Defibrillator (ICD) in patients with severe left-ventricular impairment. This therapy has not been fully adopted in our health care system, mainly due to its high cost. OBJECTIVE To assess total mortality of SCD-HeFT-like patients from our daily practice who are under stable, optimal medical treatment and who have not received an ICD; and to compare it to that of the placebo arm of the SCD-HeFT Trial. METHODS SCD-HeFT-like patients identified from office medical records were included in our study. Total mortality was assessed by telephone contact. Statistical analysis was performed by Students t-Test, Mann-Whitney Test or chi2 test, depending on the type of variable. Cumulative mortality rates were calculated according to the Kaplan-Meier method. RESULTS Our study comprised 102 patients (seventy-four of which were men) with a median age of 64 years, and an overall median ejection fraction of 25%. We found no differences between our patients and SCD-HeFT patients across these 3 variables. Over a 19.6-month follow-up period, 21 patients died (20.6%) vs. 28.8% of the SCD-HeFT patients. This difference was not statistically significant (p = 0.08). CONCLUSION SCD-HeFT-like patients from our practice had no difference in mortality rate than patients enrolled in the placebo arm of the SCD-HeFT trial. These results suggest that the SCD-HeFT population is representative of our patients.
Europace | 2012
Claudio Hadid; Sebastián Gallino; Darío Di Toro; Leonardo Celano; Carlos Alberola López; Eleonora Duce; Carlos Labadet
A 60-year-old man with Chagas disease, implanted with an implantable cardioverter defibrillator (ICD), experienced electrical storm. The ICD-stored electrograms revealed several ventricular tachycardia (VT) episodes with two different morphologies, confirmed thereafter by surface electrocardiogram. Both VTs originated from two different re-entry circuits and were successfully ablated. This case highlights the usefulness of ICD electrograms in identifying two VTs as having different sites of origin. Analysis of implantable cardioverter-defibrillator electrograms (ICD-EG) showed that monomorphic ventricular tachycardia (VT) with different QRS morphologies during different episodes (multiple morphologies, MM) predicted higher mortality. 1 A 60-year-old man implanted with an ICD (Medtronic Maximo-VR7232) for secondary prevention of death, with Chagas disease and left ventricular ejection fraction (LVEF), 0.45 was hospitalized for electrical storm. The ICD interrogation revealed 62 episodes of monomorphic VT. Analysing ICD-EG, a difference in morphology was seen only in the HVA/HVB electrogram (a QS complex in Figure 1A; a Qr complex in Figure 1B). During hospitalization he experienced several VT episodes and surface-electrocardiogram Figure 1 Schematic representation of the endocardial surface of the left ventricle. (A) and (B) Implantable cardioverter defibrillator- stored electrograms showing two different morphologies of the HVA/HVB electrogram. Note that this difference is not evident in the Vtip-Vring electrogram
Cardiology Journal | 2016
Sergio Dubner; Claudio Hadid; Damián Azocar; Carlos Labadet; Cecilia Valsecchi; Agustín E. Domínguez
BACKGROUND The noncontact mapping system facilitates the mapping of premature ventricular contractions (PVCs) and ventricular tachycardia (VT) using a 64-electrode expandable balloon catheter (ARRAY, St. Jude Medical). The aim of this study is to analyze the results and follow-up of the PVC ablation using this system. METHODS AND RESULTS Prospective and consecutive patients with frequent PVCs (6,000 or more) or monomorphic VT, suspected to be originated on the right ventricular outflow tract (RVOT), were included. The balloon catheter was positioned in the RVOT. Eighteen patients, 9 women, mean age 48 years (youngest/oldest 19-65) were included. Sixteen patients presented no structural heart disease. The origin of the arrhythmia was RVOT (n = 15), right ventricular inflow tract (n = 1), and left ventricular outflow tract (n = 2). Acute success was achieved in 15 patients; in 2 patients radiofrequency was not applied due to security reasons (origin site close to left coronary artery origin). The mean follow-up was 15 months (min. 4, max. 26); 13 patients presented abolition of the arrhythmia without drugs and 1 patient required antiarrhythmic drugs for arrhythmia control (previously ineffective). As an only complication, a femoral artery-venous fistula was observed. CONCLUSIONS The noncontact mapping system using a multielectrode balloon allows right ventricular arrhythmia treatment with a high rate of efficacy and safety.
Revista Espanola De Cardiologia | 2013
Claudio Hadid; Darío Di Toro; Sebastián Gallino; Carlos Labadet
We have read with attention the scientific letter published by Evertz et al. entitled ‘‘Dual Ventricular Response: Another Road to Supraventricular Tachycardia in Dual Atrioventricular Nodal Physiology’’. As the authors clearly explain, their case concerned a form of supraventricular ‘‘pseudotachycardia’’ in which they established a differential diagnosis involving 2 conditions: atrial tachycardia (quickly ruled out during the electrophysiological study) and bigeminy arising from the bundle of His. The latter diagnosis is not easily differentiated. The authors ruled out premature contractions of the bundle of His due to the consistent relationship of the His and ventricular action potentials to the preceding atrial action potential. However, in the description of the electrocardiographic recording shown in Figure 1 of their letter, the authors mention certain irregularity of up to 50 ms in the PR2 interval. As they state in the text, the diagnosis of dual nodal physiology was more evident once the dual ventricular response had disappeared following ablation of the slow pathway. Our group reported a case of frequent extrasystoles arising from the bundle of His in which, as in that described by Evertz et al., the patient had been referred to us with palpitations and supraventricular tachycardia. Our patient showed a wider variability in the H1-H2 interval, which contributed to the presence of a greater number of beats with aberrant conduction and facilitated the differential diagnosis. Moreover, in our case, the presence of blocked P waves and ‘‘pseudoblock’’ of atrioventricular conduction was incompatible with the existence of dual nodal physiology. By way of this letter, we wish to stress how difficult it is on occasion to differentiate between these two conditions during the diagnostic stage of the electrophysiological study performed prior to ablation. The diagnosis of premature beats arising from the bundle of His can be confirmed using a detailed map of the region
Journal of Cardiovascular Electrophysiology | 2013
Claudio Hadid; Darío Di Toro; Sebastián Gallino; Carlos Labadet
We read with great interest the study of Vischer et al. entitled “Role of defibrillation threshold testing in the contemporary defibrillator patient population.”1 This is an interesting paper on a timely and relevant topic that retrospectively reviews data on 436 patients undergoing implantable cardioverter defibrillator (ICD) insertion with defibrillation threshold testing (DFT) in all cases (309 de novo implantations and 127 generator replacements). The authors conclude that shock testing should be performed in all patients, based on the finding that 9 (2%) patients could not be defibrillated with their standard approach, which was a 10 J safety margin. However, external rescue shock was necessary in only 5 (1.1%) patients, assuming that in the remaining 4 patients ventricular fibrillation spontaneously terminated or was defibrillated by a maximal output ICD shock. This issue is not completely clear in the paper, and more information on those 4 patients may contribute to a better understanding of DFT outcomes. Moreover, owing the lack of a nontested control group and follow-up, the recommendation to routinely perform DFT in all ICD implantations appears to be overstated, according to the findings of the study. In terms of patients’ characteristics, amiodarone therapy, dilated cardiomyopathy, and low ejection fraction were associated with shock testing failure in univariate analysis. However, a multivariate analysis (not shown) will be helpful to more accurately identify those patients at risk of an unsuccessful DFT.
Europace | 2013
Darío Di Toro; Claudio Hadid; Carlos Labadet
We read with great interest the article: ‘Value of the aVR lead in differential diagnosis of atrioventricular nodal reentrant tachycardia’ by Haghjoo et al. 1 in a recent issue of the journal. We would like to comment that the specificity of an electrocardiographic sign guarantees that in the presence of this sign, the likelihood of the disease in question is high. On the contrary, the sensitivity of a particular sign guarantees that in the absence of this sign, …
Europace | 2017
Carlos Labadet; Claudio Hadid; Darío Di Toro; Leonardo Celano; Edgar Chavez Antenaza; Carlos Alberola López
A 45-year-old man with a long history of palpitations and absence of pre-excitation in baseline electrocardiogram underwent a Holter recording, revealing several episodes of regular non-sustained broad QRS complex tachycardia that terminated following the occurrence of a narrow QRS. (Panel A). The analysis of the last narrow QRS showed a signal compatible with a retrograde P wave. An electrophysiological study was performed. During the procedure, short episodes of orthodromic tachycardia (OT) with functional left bundle branch block (LBBB) were reproduced and consistently interrupted following the occurrence of a single narrow QRS complex with exactly the same cycle length as that of the tachycardia (Panel B). The intracardiac recordings showed a 40 ms shortening of the ventriculo-atrial interval in the narrow beat and an-
Revista Argentina de Cardiología | 2015
Claudio Hadid; Damián Azocar; Darío Di Toro; Sebastián Gallino; Sergio Dubner; Carlos Labadet
Introduccion : La ablacion por cateter (AC) es beneficiosa en pacientes con taquicardia ventricular (TV) recurrente. Nuestro objetivo es revisar los casos de tormenta electrica (TE) tratados con AC. Metodos : Analisis retrospectivo de pacientes con TE debida a TV monomorfa sostenida (TVMS) tratados mediante AC. Se definio exito del procedimiento: ausencia de TV inducible al final del mismo; exito parcial: induccion de TV no clinica; no exito: inducibilidad de la TV clinica. Resultados: Se realizaron 16 procedimientos en 14 pacientes: 10 exitosos, 3 exito parcial y 3 no exitosos. Todos los pacientes evolucionaron sin arritmia ventricular inmediatamente post-ablacion. Diez pacientes (71,4%) evolucionaron sin TV y 86,7% sin TE (seguimiento 8 [3-30] meses). Cinco pacientes (35,7%) murieron de causa no arritmica. Conclusiones: La AC se asocia a una supresion aguda de TV en todos los pacientes con TE debida a TVMS y a una evolucion sin recurrencia en la mayoria de ellos.
Argentine Journal of Cardiology | 2014
Damián Azocar; Sergio Dubner; Carlos Labadet; Claudio Hadid; María C. Valsecchi; Agustín E. Domínguez
Introduction and objective: The non-contact mapping system with expandable balloon catheter allows ventricular arrhythmiamapping with few ectopic beats. The aim of this study was to analyze ablation results with this system.Methods: Patients with ventricular arrhythmia were prospectively and consecutively studied with the non-contact mappingsystem.Results: The study included 10 patients, 8 women, with mean age of 45 years (range: 27 to 65). Arrhythmia origin was rightventricular outflow tract in 8 patients, right ventricular inflow tract in 1 and left ventricular outflow tract in 1. Acute successwas obtained in 9/10 patients (90%). Mean follow-up was 6 months (range 1 to 16); 8 patients continued with obliteratedarrhythmia without medication and 1 patient required pharmacologic treatment. The only complication was femoralarteriovenous fistula.Conclusions: The non-contact mapping system allows a highly efficient and safe approach of right ventricular arrhythmias.Future studies with more patients and comparing with other methods may confirm these results.