Claus Helix Nielsen
Technical University of Denmark
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Claus Helix Nielsen.
The Journal of General Physiology | 2004
Jens A. Lundbæk; P. Birn; Anker Jon Hansen; Rikke Søgaard; Claus Helix Nielsen; Jeffrey Girshman; Michael J. Bruno; Sonya E. Tape; Jan Egebjerg; Denise V. Greathouse; Gwendolyn L. Mattice; Roger E. Koeppe; Olaf S. Andersen
Membrane proteins are regulated by the lipid bilayer composition. Specific lipid–protein interactions rarely are involved, which suggests that the regulation is due to changes in some general bilayer property (or properties). The hydrophobic coupling between a membrane-spanning protein and the surrounding bilayer means that protein conformational changes may be associated with a reversible, local bilayer deformation. Lipid bilayers are elastic bodies, and the energetic cost of the bilayer deformation contributes to the total energetic cost of the protein conformational change. The energetics and kinetics of the protein conformational changes therefore will be regulated by the bilayer elasticity, which is determined by the lipid composition. This hydrophobic coupling mechanism has been studied extensively in gramicidin channels, where the channel–bilayer hydrophobic interactions link a “conformational” change (the monomer↔dimer transition) to an elastic bilayer deformation. Gramicidin channels thus are regulated by the lipid bilayer elastic properties (thickness, monolayer equilibrium curvature, and compression and bending moduli). To investigate whether this hydrophobic coupling mechanism could be a general mechanism regulating membrane protein function, we examined whether voltage-dependent skeletal-muscle sodium channels, expressed in HEK293 cells, are regulated by bilayer elasticity, as monitored using gramicidin A (gA) channels. Nonphysiological amphiphiles (β-octyl-glucoside, Genapol X-100, Triton X-100, and reduced Triton X-100) that make lipid bilayers less “stiff”, as measured using gA channels, shift the voltage dependence of sodium channel inactivation toward more hyperpolarized potentials. At low amphiphile concentration, the magnitude of the shift is linearly correlated to the change in gA channel lifetime. Cholesterol-depletion, which also reduces bilayer stiffness, causes a similar shift in sodium channel inactivation. These results provide strong support for the notion that bilayer–protein hydrophobic coupling allows the bilayer elastic properties to regulate membrane protein function.
Analytical and Bioanalytical Chemistry | 2009
Claus Helix Nielsen
Biological membranes constitute the set of membranes defining boundaries and organelles in living cells—the structural and functional building blocks of all known living organisms. The integrity of the cell depends on its ability to separate inside from outside and yet at the same time allow massive transport of matter in and out the cell. Nature has elegantly met this challenge by developing membranes in the form of lipid bilayers in which specialized and highly efficient transport proteins are incorporated. This raises the question: is it possible to mimic biological membranes and create membrane-based sensor and/or separation devices? In the development of biomimetic sensor/separation technology, both channels (ion and water channels) and carriers (transporters) are important. Generally, each class of transport proteins conducts specific molecular species in and out of the cell while preventing the passage of others, a property critical for the overall conservation of the cells internal pH and salt concentration. Both ion and water channels are highly efficient membrane pore proteins capable of transporting solutes at very high rates, up to 109 molecules per second. Carrier proteins generally have a lower turnover but are capable of transport against gradients. For both classes of proteins, their unique flux-properties make them interesting as candidates in biomimetic sensor/separation devices. An ideal sensor/separation device requires the supporting biomimetic matrix to be virtually impermeable to anything but the solute in question. In practice, however, a biomimetic support matrix will generally have finite permeabilities to water, electrolytes, and non-electrolytes. The feasibility of a biomimetic device thus depends on the relative transport contribution from both protein and biomimetic support matrix. Also the stability of the incorporated protein must be addressed and the protein-biomimetic matrix must be encapsulated in order to protect it and make it sufficiently stable in a final application. Here I will review and discuss these challenges and how they are met in some current developments of biomimetic sensor/separation devices.
Biochemistry | 2006
Rikke Søgaard; Thomas Werge; Camilla Bertelsen; Camilla Lundbye; Kenneth L. Madsen; Claus Helix Nielsen; Jens A. Lundbæk
Docosahexaenoic acid (DHA) and other polyunsaturated fatty acids (PUFAs) promote GABA(A) receptor [(3)H]-muscimol binding, and DHA increases the rate of GABA(A) receptor desensitization. Triton X-100, a structurally unrelated amphiphile, similarly promotes [(3)H]-muscimol binding. The mechanism(s) underlying these effects are poorly understood. DHA and Triton X-100, at concentrations that affect GABA(A) receptor function, increase the elasticity of lipid bilayers measured as decreased bilayer stiffness using gramicidin channels as molecular force transducers. We have previously shown that membrane protein function can be regulated by amphiphile-induced changes in bilayer elasticity and hypothesized that GABA(A) receptors could be similarly regulated. We therefore studied the effects of four structurally unrelated amphiphiles that decrease bilayer stiffness (Triton X-100, octyl-beta-glucoside, capsaicin, and DHA) on GABA(A) receptor function in mammalian cells. All the compounds promoted GABA(A) receptor [(3)H]-muscimol binding by increasing the binding capacity of high-affinity binding without affecting the associated equilibrium binding constant. A semiquantitative analysis found a similar quantitative relation between the effects on bilayer stiffness and [(3)H]-muscimol binding. Membrane cholesterol depletion, which also decreases bilayer stiffness, similarly promoted [(3)H]-muscimol binding. In whole-cell voltage-clamp experiments, Triton X-100, octyl-beta-glucoside, capsaicin, and DHA all reduced the peak amplitude of the GABA-induced currents and increased the rate of receptor desensitization. The effects of the amphiphiles did not correlate with the expected changes in monolayer spontaneous curvature. We conclude that GABA(A) receptor function is regulated by lipid bilayer elasticity. PUFAs may generally regulate membrane protein function by affecting the elasticity of the host lipid bilayer.
Langmuir | 2009
Alfredo González-Pérez; Karin B. Stibius; Thomas Vissing; Claus Helix Nielsen; Ole G. Mouritsen
It is demonstrated that biomimetic stable triblock copolymer membrane arrays can be prepared using a scaffold containing 64 apertures of 300 microm diameter each. The membranes were made from a stock solution of block copolymers with decane as a solvent using a new deposition method. By using decane, we avoid low molecular weight solvents such as chloroform and toluene, which are strong protein denaturants. The membranes show a low ionic conductance and a long lifetime at room temperature. Contrast phase microscopy shows the presence of a polymer region delimited by a Plateau-Gibbs border similar to what is observed in black lipid membranes. The ion-channel gramicidin A was successfully incorporated into the membrane in a functional form.
Journal of Micromechanics and Microengineering | 2009
Jesper Søndergaard Hansen; Mark Perry; Jörg Vogel; Thomas Vissing; Christian Rein Hansen; Oliver Geschke; Jenny Emnéus; Claus Helix Nielsen
In the present work, a technique for establishing multiple black lipid membranes (BLMs) in arrays of micro structured ethylene tetrafluoroethylene (ETFE) films, and supported by a micro porous material was developed. Rectangular 8 × 8 arrays with apertures having diameters of 301 ± 5 µm were fabricated in ETFE Teflon film by laser ablation using a carbon dioxide laser. Multiple lipid membranes could be formed across the micro structured 8 × 8 array ETFE partitions. Success rates for the establishment of cellulose-supported BLMs across the multiple aperture arrays were above 95%. However, the time course of the membrane thinning process was found to vary considerably between multiple aperture bilayer experiments. An airbrush partition pretreatment technique was developed to increase the reproducibility of the multiple lipid bilayers formation during the time course from the establishment of the lipid membranes to the formation of bilayers. The results showed that multiple lipid bilayers could be reproducible formed across the airbrush-pretreated 8 × 8 rectangular arrays. The ionophoric peptide valinomycin was incorporated into established membrane arrays, resulting in ionic currents that could be effectively blocked by tetraethylammonium. This shows that functional bimolecular lipid membranes were established, and furthermore outlines that the established lipid membrane arrays could host functional membrane-spanning molecules.
Journal of Micromechanics and Microengineering | 2009
Jörg Vogel; Mark Perry; Jesper Søndergaard Hansen; P.-Y. Bolinger; Claus Helix Nielsen; Oliver Geschke
Water filtration on the basis of aquaporin molecules incorporated in an artificial lipid bilayer requires a microporous support membrane. We describe a new microfabrication method based on CO2-laser ablation to generate support membranes with homogeneous apertures ranging from 300 µm down to 84 µm in diameter. They are arranged in arrays with the densest packaging having a perforation level of up to 60%. The apertures are surrounded by a smooth bulge that is formed by melted material ejected from the aperture during laser ablation. Polydimethylsiloxane (PDMS) replicas were used to visualize and analyse these bulges. The overall area covered so far has been 4 cm2 but upscaling to larger footprints, e.g. square metres, is currently being investigated.
Biochimica et Biophysica Acta | 2011
Lin Xin; Haibin Su; Claus Helix Nielsen; Chuyang Y. Tang; Jaume Torres; Yuguang Mu
Molecular dynamics simulations of aquaporin Z homotetramer which is a membrane protein facilitating rapid water movement through the plasma membrane of Escherichia coli were performed. Initial configurations were taken from the open and closed states of crystal structures separately. The resulting water osmotic permeability (pf) and diffusive permeability (pd) displayed distinct features. Consistent with previous studies, the side chain conformation of arginine189 was found to mediate the water permeability. A potential of mean force (PMF) as a function of the distance between NH1 of R189 and carbonyl oxygen of A117 was constructed based on the umbrella sampling technique. There are multiple local minima and transition states on the PMF. The assignment of the open or closed state was supported by the permeability pf, calculated within trajectories in umbrella sampling simulations. Our study disclosed a detailed mechanism of the gated water transport.
Optics Letters | 2011
Cameron L. C. Smith; Johan Ulrik Lind; Claus Helix Nielsen; Mads Brøkner Christiansen; Thomas Buss; Niels Bent Larsen; Anders Kristensen
We present the enhanced transduction of a photonic crystal dye laser for gas sensing via deposition of an additional swelling polymer film. Device operation involves swelling of the polymer film during exposure to specific gases, leading to a change in total effective refractive index. Experimental results show an enhancement of 16.09 dB in sensing ethanol vapor after deposition of a polystyrene film. We verify different responses of the polystyrene film when exposed to either ethanol vapor or increased humidity, indicating selectivity. The concept is generic and, in principle, straightforward in its application to other intracavity-based detection schemes to enable gas sensing.
Advances in Experimental Medicine and Biology | 2010
Claus Helix Nielsen
Biological membranes define the structural and functional boundaries in living cells and their organelles. The integrity of the cell depends on its ability to separate inside from outside and yet at the same time allow massive transport of matter in and out the cell. Nature has elegantly met this challenge by developing membranes in the form of lipid bilayers in which specialized transport proteins are incorporated. This raises the question: is it possible to mimic biological membranes and create a membrane based sensor and/or separation device? In the development of a biomimetic sensor/separation technology, a unique class of membrane transport proteins is especially interesting-the major intrinsic proteins (MIPs). Generally, MIPs conduct water molecules and selected solutes in and out of the cell while preventing the passage of other solutes, a property critical for the conservation of the cells internal pH and salt concentration. Also known as water channels or aquaporins they are highly efficient membrane pore proteins some of which are capable of transporting water at very high rates up to 10(9) molecules per second. Some MIPs transport other small, uncharged solutes, such as glycerol and other permeants such as carbon dioxide, nitric oxide, ammonia, hydrogen peroxide and the metalloids antimonite, arsenite, silicic and boric acid depending on the effective restriction mechanism of the protein. The flux properties of MIPs thus lead to the question ifMIPs can be used in separation devices or as sensor devices based on, e.g., the selective permeation of metalloids. In principle a MIP based membrane sensor/separation device requires the supporting biomimetic matrix to be virtually impermeable to anything but water or the solute in question. In practice, however, a biomimetic support matrix will generally have finite permeabilities to both electrolytes and non-electrolytes. The feasibility of a biomimetic MIP device thus depends on the relative transport contribution from both protein and biomimetic support matrix. Also the biomimetic matrix must be encapsulated in order to protect it and make it sufficiently stable in a final application. Here, I specifically discuss the feasibility of developing osmotic biomimetic MIP membranes, but the technical issues are of general concern in the design ofbiomimetic membranes capable of supporting selective transmembrane fluxes.
Bioinspiration & Biomimetics | 2009
Mark Perry; Thomas Vissing; Thomas Boesen; Jesper Søndergaard Hansen; Jenny Emnéus; Claus Helix Nielsen
Recent advances in biomimetic membrane systems have resulted in an increase in membrane lifetimes from hours to days and months. Long-lived membrane systems demand the development of both new automated monitoring equipment capable of measuring electrophysiological membrane characteristics and new data processing software to analyze and organize the large amounts of data generated. In this work, we developed an automated instrumental voltage clamp solution based on a custom-designed software controller application (the WaveManager), which enables automated on-line voltage clamp data acquisition applicable to long-time series experiments. We designed another software program for off-line data processing. The automation of the on-line voltage clamp data acquisition and off-line processing was furthermore integrated with a searchable database (DiscoverySheet) for efficient data management. The combined solution provides a cost efficient and fast way to acquire, process and administrate large amounts of voltage clamp data that may be too laborious and time consuming to handle manually.