Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Clay D. Reber is active.

Publication


Featured researches published by Clay D. Reber.


PLOS ONE | 2014

Quantitative Imaging with a Mobile Phone Microscope

Arunan Skandarajah; Clay D. Reber; Neil Switz; Daniel A. Fletcher

Use of optical imaging for medical and scientific applications requires accurate quantification of features such as object size, color, and brightness. High pixel density cameras available on modern mobile phones have made photography simple and convenient for consumer applications; however, the camera hardware and software that enables this simplicity can present a barrier to accurate quantification of image data. This issue is exacerbated by automated settings, proprietary image processing algorithms, rapid phone evolution, and the diversity of manufacturers. If mobile phone cameras are to live up to their potential to increase access to healthcare in low-resource settings, limitations of mobile phone–based imaging must be fully understood and addressed with procedures that minimize their effects on image quantification. Here we focus on microscopic optical imaging using a custom mobile phone microscope that is compatible with phones from multiple manufacturers. We demonstrate that quantitative microscopy with micron-scale spatial resolution can be carried out with multiple phones and that image linearity, distortion, and color can be corrected as needed. Using all versions of the iPhone and a selection of Android phones released between 2007 and 2012, we show that phones with greater than 5 MP are capable of nearly diffraction-limited resolution over a broad range of magnifications, including those relevant for single cell imaging. We find that automatic focus, exposure, and color gain standard on mobile phones can degrade image resolution and reduce accuracy of color capture if uncorrected, and we devise procedures to avoid these barriers to quantitative imaging. By accommodating the differences between mobile phone cameras and the scientific cameras, mobile phone microscopes can be reliably used to increase access to quantitative imaging for a variety of medical and scientific applications.


Science Translational Medicine | 2015

Point-of-care quantification of blood-borne filarial parasites with a mobile phone microscope

Michael V. D'Ambrosio; Matthew H. Bakalar; Bennuru S; Clay D. Reber; Arunan Skandarajah; Nilsson Lm; Neil Switz; Joseph Kamgno; Sébastien Pion; Michel Boussinesq; Thomas B. Nutman; Daniel A. Fletcher

Loa loa microfilariae load in blood can be automatically quantified at the point of care using a mobile phone video microscope. Dial “L” for Loa: Answering the call for mass drug administration Filarial nematodes—tiny, parasitic worms that get into the bloodstream and use humans as hosts—are common in certain regions in Africa. One of these filarial nematodes, Loa loa, the causative agent of loiasis, is not compatible with current ivermectin-based mass drug administration (MDA) programs in the region, which are aimed to eliminate other worms that cause onchocerciasis and lymphatic filariasis. MDA causes severe and often fatal neurological side effects for patients co-infected with L. loa; thus, many MDA programs have been suspended. To resume these ivermectin-based campaigns, D’Ambrosio et al. devised a mobile phone–based strategy for quantifying Loa microfilariae in whole blood and, in turn, excluding those individuals from MDA. The authors’ Loa-counting device comprised a mobile phone camera (as the video microscope) and a custom algorithm for tracking the “wriggling” motion of the microfilaria by quantifying the displacement of red blood cells surrounding the Loa. The entire device was packaged for point-of-care use, including its own “app” for smartphones. When tested on samples from 33 potentially Loa-infected subjects in Cameroon, Africa, the device was 94% specific (compared with microscopy results from thick blood smears) and 100% sensitive for patients about the threshold for severe adverse events (30,000 microfilaria per milliliter of blood). With its ease of use and only a fingerprick of blood, this mobile analytical device could be integrated into MDA programs, answering the call for safe and effective programs in Loa-endemic regions. Parasitic helminths cause debilitating diseases that affect millions of people in primarily low-resource settings. Efforts to eliminate onchocerciasis and lymphatic filariasis in Central Africa through mass drug administration have been suspended because of ivermectin-associated serious adverse events, including death, in patients infected with the filarial parasite Loa loa. To safely administer ivermectin for onchocerciasis or lymphatic filariasis in regions co-endemic with L. loa, a strategy termed “test and (not) treat” has been proposed whereby those with high levels of L. loa microfilariae (>30,000/ml) that put them at risk for life-threatening serious adverse events are identified and excluded from mass drug administration. To enable this, we developed a mobile phone–based video microscope that automatically quantifies L. loa microfilariae in whole blood loaded directly into a small glass capillary from a fingerprick without the need for conventional sample preparation or staining. This point-of-care device automatically captures and analyzes videos of microfilarial motion in whole blood using motorized sample scanning and onboard motion detection, minimizing input from health care workers and providing a quantification of microfilariae per milliliter of whole blood in under 2 min. To validate performance and usability of the mobile phone microscope, we tested 33 potentially Loa-infected patients in Cameroon and confirmed that automated counts correlated with manual thick smear counts (94% specificity; 100% sensitivity). Use of this technology to exclude patients from ivermectin-based treatment at the point of care in Loa-endemic regions would allow resumption/expansion of mass drug administration programs for onchocerciasis and lymphatic filariasis in Central Africa.


Journal of Clinical Microbiology | 2013

Mobile Digital Fluorescence Microscopy for Diagnosis of Tuberculosis

Asa Tapley; Neil Switz; Clay D. Reber; J. L. Davis; Cecily Miller; J. B. Matovu; William Worodria; Laurence Huang; Daniel A. Fletcher; Adithya Cattamanchi

ABSTRACT Access to sputum smear microscopy in high-tuberculosis (TB)-burden regions is limited by a scarcity of microscopes and experienced technicians. We evaluated the accuracy of CellScope, a novel digital fluorescence microscope that may expand access to microscopy. The study utilized smear microscopy slides prepared from sputum specimens submitted by consecutive adults with ≥2 weeks of cough who were admitted to Mulago Hospital (Kampala, Uganda). Conventional light-emitting diode (LED) fluorescence microscopy (FM) and mycobacterial culture were performed by experienced technicians. Two U.S.-based postgraduate researchers without prior microscopy experience restained, imaged, and interpreted the slides using CellScope. We assessed whether sensitivity and specificity of CellScope-based LED FM was noninferior to conventional LED FM by using a preselected margin of inferiority of 15%. Of 525 patients included, 72% were HIV seropositive and 39% had culture-confirmed TB. The proportions of positive results were similar with CellScope and conventional LED FM (34% versus 32%, respectively; P = 0.32), and agreement was substantial. CellScope accuracy was within the noninferiority margin for both sensitivity (63% versus 70%; difference, −7%; 95% confidence interval [CI], −13% to −1%) and specificity (85% versus 92%; difference, −7%; 95% CI, −12% to −3%). A subanalysis of 43 slides evaluated by each CellScope reader found substantial interreader reliability (custom-weighted kappa, 0.65) and variable intrareader reliability (custom-weighted kappa, 0.11 versus 0.48). CellScope offers promise for expanding microscopy services. Future studies should evaluate the device when operated by health workers in low-resource settings, the feasibility of image transmission and analysis by experienced microscopists, and the accuracy of automated image analysis algorithms.


medical image computing and computer assisted intervention | 2012

Automated Tuberculosis Diagnosis Using Fluorescence Images from a Mobile Microscope

Jeannette Chang; Pablo Andrés Arbeláez; Neil Switz; Clay D. Reber; Asa Tapley; J. Lucian Davis; Adithya Cattamanchi; Daniel A. Fletcher; Jitendra Malik

In low-resource areas, the most common method of tuberculosis (TB) diagnosis is visual identification of rod-shaped TB bacilli in microscopic images of sputum smears. We present an algorithm for automated TB detection using images from digital microscopes such as CellScope, a novel, portable device capable of brightfield and fluorescence microscopy. Automated processing on such platforms could save lives by bringing healthcare to rural areas with limited access to laboratory-based diagnostics. Our algorithm applies morphological operations and template matching with a Gaussian kernel to identify candidate TB-objects. We characterize these objects using Hu moments, geometric and photometric features, and histograms of oriented gradients and then perform support vector machine classification. We test our algorithm on a large set of CellScope images (594 images corresponding to 290 patients) from sputum smears collected at clinics in Uganda. Our object-level classification performance is highly accurate, with average precision of 89.2% +/- 2.1%. For slide-level classification, our algorithm performs at the level of human readers, demonstrating the potential for making a significant impact on global healthcare.


PLOS ONE | 2014

Multicellular Architecture of Malignant Breast Epithelia Influences Mechanics

Gautham Venugopalan; David B. Camarillo; Kevin D. Webster; Clay D. Reber; James A. Sethian; Valerie M. Weaver; Daniel A. Fletcher; Hana El-Samad; Chris H. Rycroft

Cell–matrix and cell–cell mechanosensing are important in many cellular processes, particularly for epithelial cells. A crucial question, which remains unexplored, is how the mechanical microenvironment is altered as a result of changes to multicellular tissue structure during cancer progression. In this study, we investigated the influence of the multicellular tissue architecture on mechanical properties of the epithelial component of the mammary acinus. Using creep compression tests on multicellular breast epithelial structures, we found that pre-malignant acini with no lumen (MCF10AT) were significantly stiffer than normal hollow acini (MCF10A) by 60%. This difference depended on structural changes in the pre-malignant acini, as neither single cells nor normal multicellular acini tested before lumen formation exhibited these differences. To understand these differences, we simulated the deformation of the acini with different multicellular architectures and calculated their mechanical properties; our results suggest that lumen filling alone can explain the experimentally observed stiffness increase. We also simulated a single contracting cell in different multicellular architectures and found that lumen filling led to a 20% increase in the “perceived stiffness” of a single contracting cell independent of any changes to matrix mechanics. Our results suggest that lumen filling in carcinogenesis alters the mechanical microenvironment in multicellular epithelial structures, a phenotype that may cause downstream disruptions to mechanosensing.


eLife | 2018

Transient external force induces phenotypic reversion of malignant epithelial structures via nitric oxide signaling

Benjamin L Ricca; Gautham Venugopalan; Saori Furuta; Kandice Tanner; Walter A Orellana; Clay D. Reber; Douglas G Brownfield; Mina J. Bissell; Daniel A. Fletcher

Non-malignant breast epithelial cells cultured in three-dimensional laminin-rich extracellular matrix (lrECM) form well organized, growth-arrested acini, whereas malignant cells form continuously growing disorganized structures. While the mechanical properties of the microenvironment have been shown to contribute to formation of tissue-specific architecture, how transient external force influences this behavior remains largely unexplored. Here, we show that brief transient compression applied to single malignant breast cells in lrECM stimulated them to form acinar-like structures, a phenomenon we term ‘mechanical reversion.’ This is analogous to previously described phenotypic ‘reversion’ using biochemical inhibitors of oncogenic pathways. Compression stimulated nitric oxide production by malignant cells. Inhibition of nitric oxide production blocked mechanical reversion. Compression also restored coherent rotation in malignant cells, a behavior that is essential for acinus formation. We propose that external forces applied to single malignant cells restore cell-lrECM engagement and signaling lost in malignancy, allowing them to reestablish normal-like tissue architecture.


International Journal of Tuberculosis and Lung Disease | 2015

Evaluation of mobile digital light-emitting diode fluorescence microscopy in Hanoi, Viet Nam.

Lelia H. Chaisson; Clay D. Reber; Phan H; Neil Switz; Nilsson Lm; Myers F; Nhung Nv; Luu L; Pham T; Vu C; Nguyen H; Nguyen A; Dinh T; Payam Nahid; Daniel A. Fletcher; Adithya Cattamanchi

SETTING Hanoi Lung Hospital, Hanoi, Viet Nam. OBJECTIVE To compare the accuracy of CellScopeTB, a manually operated mobile digital fluorescence microscope, with conventional microscopy techniques. DESIGN Patients referred for sputum smear microscopy to the Hanoi Lung Hospital from May to September 2013 were included. Ziehl-Neelsen (ZN) smear microscopy, conventional light-emitting diode (LED) fluorescence microscopy (FM), CellScopeTB-based LED FM and Xpert(®) MTB/RIF were performed on sputum samples. The sensitivity and specificity of microscopy techniques were determined in reference to Xpert results, and differences were compared using McNemars paired test of proportions. RESULTS Of 326 patients enrolled, 93 (28.5%) were Xpert-positive for TB. The sensitivity of ZN microscopy, conventional LED FM, and CellScopeTB-based LED FM was respectively 37.6% (95%CI 27.8-48.3), 41.9% (95%CI 31.8-52.6), and 35.5% (95%CI 25.8-46.1). The sensitivity of CellScopeTB was similar to that of conventional LED FM (difference -6.5%, 95%CI -18.2 to 5.3, P = 0.33) and ZN microscopy (difference -2.2%, 95%CI -9.2 to 4.9, P = 0.73). The specificity was >99% for all three techniques. DISCUSSION CellScopeTB performed similarly to conventional microscopy techniques in the hands of experienced TB microscopists. However, the sensitivity of all sputum microscopy techniques was low. Options enabled by digital microscopy, such as automated imaging with real-time computerized analysis, should be explored to increase sensitivity.


PLOS ONE | 2017

Mobile microscopy as a screening tool for oral cancer in India: A pilot study

Arunan Skandarajah; Sumsum P. Sunny; Praveen Gurpur; Clay D. Reber; Michael V. D’Ambrosio; Nisheena Raghavan; Bonney Lee James; Ravindra D. Ramanjinappa; Amritha Suresh; Uma Kandasarma; Praveen Birur; Vinay Kumar; Honorius-Cezar Galmeanu; Alexandru Mihail Itu; Mihai Modiga-Arsu; Saskia Rausch; Maria Sramek; Manohar Kollegal; Gianluca Paladini; Moni Abraham Kuriakose; Lance Anthony Ladic; Felix Peter Koch; Daniel A. Fletcher

Oral cancer is the most common type of cancer among men in India and other countries in South Asia. Late diagnosis contributes significantly to this mortality, highlighting the need for effective and specific point-of-care diagnostic tools. The same regions with high prevalence of oral cancer have seen extensive growth in mobile phone infrastructure, which enables widespread access to telemedicine services. In this work, we describe the evaluation of an automated tablet-based mobile microscope as an adjunct for telemedicine-based oral cancer screening in India. Brush biopsy, a minimally invasive sampling technique was combined with a simplified staining protocol and a tablet-based mobile microscope to facilitate local collection of digital images and remote evaluation of the images by clinicians. The tablet-based mobile microscope (CellScope device) combines an iPad Mini with collection optics, LED illumination and Bluetooth-controlled motors to scan a slide specimen and capture high-resolution images of stained brush biopsy samples. Researchers at the Mazumdar Shaw Medical Foundation (MSMF) in Bangalore, India used the instrument to collect and send randomly selected images of each slide for telepathology review. Evaluation of the concordance between gold standard histology, conventional microscopy cytology, and remote pathologist review of the images was performed as part of a pilot study of mobile microscopy as a screening tool for oral cancer. Results indicated that the instrument successfully collected images of sufficient quality to enable remote diagnoses that show concordance with existing techniques. Further studies will evaluate the effectiveness of oral cancer screening with mobile microscopy by minimally trained technicians in low-resource settings.


Translational Vision Science & Technology | 2018

A Smartphone-Based Tool for Rapid, Portable, and Automated Wide-Field Retinal Imaging

Tyson N. Kim; Frank B. Myers; Clay D. Reber; Pj Loury; Panagiota Loumou; Doug Webster; Chris Echanique; Patrick Li; Jose R. Davila; Robi N. Maamari; Neil A. Switz; Jeremy D. Keenan; Maria A. Woodward; Yannis M. Paulus; Todd P. Margolis; Daniel A. Fletcher

Purpose High-quality, wide-field retinal imaging is a valuable method for screening preventable, vision-threatening diseases of the retina. Smartphone-based retinal cameras hold promise for increasing access to retinal imaging, but variable image quality and restricted field of view can limit their utility. We developed and clinically tested a smartphone-based system that addresses these challenges with automation-assisted imaging. Methods The system was designed to improve smartphone retinal imaging by combining automated fixation guidance, photomontage, and multicolored illumination with optimized optics, user-tested ergonomics, and touch-screen interface. System performance was evaluated from images of ophthalmic patients taken by nonophthalmic personnel. Two masked ophthalmologists evaluated images for abnormalities and disease severity. Results The system automatically generated 100° retinal photomontages from five overlapping images in under 1 minute at full resolution (52.3 pixels per retinal degree) fully on-phone, revealing numerous retinal abnormalities. Feasibility of the system for diabetic retinopathy (DR) screening using the retinal photomontages was performed in 71 diabetics by masked graders. DR grade matched perfectly with dilated clinical examination in 55.1% of eyes and within 1 severity level for 85.2% of eyes. For referral-warranted DR, average sensitivity was 93.3% and specificity 56.8%. Conclusions Automation-assisted imaging produced high-quality, wide-field retinal images that demonstrate the potential of smartphone-based retinal cameras to be used for retinal disease screening. Translational Relevance Enhancement of smartphone-based retinal imaging through automation and software intelligence holds great promise for increasing the accessibility of retinal screening.


Archive | 2016

AUTOMATED HARDWARE AND SOFTWARE FOR MOBILE MICROSCOPY

Daniel A. Fletcher; Michael V. D'Ambrosio; Arunan Skandarajah; Frank B. Myers; Clay D. Reber

Collaboration


Dive into the Clay D. Reber's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Neil Switz

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Asa Tapley

University of California

View shared research outputs
Top Co-Authors

Avatar

Frank B. Myers

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge